• Title/Summary/Keyword: Methyl Ethyl Ketone

Search Result 137, Processing Time 0.028 seconds

Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control (공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석)

  • Jo, Wan-Kuen;Kim, Wang-Tae
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

Prediction of the Toxicity of Dimethylformamide, Methyl Ethyl Ketone, and Toluene Mixtures by QSAR Modeling

  • Kim, Ki-Woong;Won, Yong Lim;Hong, Mun Ki;Jo, Jihoon;Lee, Sung Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.12
    • /
    • pp.3637-3641
    • /
    • 2014
  • In this study, we analyzed the toxicity of mixtures of dimethylformamide (DMF) and methyl ethyl ketone (MEK) or DMF and toluene (TOL) and predicted their toxicity using quantitative structure-activity relationships (QSAR). A QSAR model for single substances and mixtures was analyzed using multiple linear regression (MLR) by taking into account the statistical parameters between the observed and predicted $EC_{50}$. After preprocessing, the best subsets of descriptors in the learning methods were determined using a 5-fold cross-validation method. Significant differences in physico-chemical properties such as boiling point (BP), specific gravity (SG), Reid vapor pressure (rVP), flash point (FP), low explosion limit (LEL), and octanol/water partition coefficient (Pow) were observed between the single substances and the mixtures. The $EC_{50}$ of the mixture of DMF and TOL was significantly lower than that of DMF. The mixture toxicity was directly related to the mixing ratio of TOL and MEK (MLR $EC_{50}$ equation = $1.76997-1.12249{\times}TOL+1.21045{\times}MEK$), as well as to SG, VP, and LEL (MLR equation $EC_{50}=15.44388-19.84549{\times}SG+0.05091{\times}VP+1.85846{\times}LEL$). These results show that QSAR-based models can be used to quantitatively predict the toxicity of mixtures used in manufacturing industries.

A Study on Difference in Coercivity between Substituted Barium Ferrite Powder and Its Tape (자기기록용 치환형 Ba-Ferrite 분말과 Tape의 보자력 차이에 관한 연구)

  • 홍양기;정홍식;김현준
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.251-257
    • /
    • 1996
  • A coercivity of barium ferrite (BaM) tape was found to be higher than the coercivity of BaM powder, This difference is in the range of 50 Oe to 600 Oe, which depends on substituted cations. physical properties of powder, and preparation conditions of the tape. The coercivity difference is attributed to both particle stacking and adsorption of organic solvent on particle surface. Regardless of substituted cations, the coercivity of longitudinally oriented BaFe tape was higher than that of BaM powder by a range of 100 Oe to 120 Oe, which is caused by particle stacking' During the active adsorption process on preparation of magnetic paint, where MEK (methyl ethyl ketone), TOL (toluene) and CHO (cyclohexanone) were used, chemisorption of solvents on the surface of substituted BaFe particle occurred to form polymeric compounds surrounding the particle. An increase in coercivity, caused by the solvent adsorption, was significant for Co-substutited BaM tape. Among these solvents CHO was the most effective one in increasing the coercivity of the Co-Ti substituted BaM tape.

  • PDF

A Convenient Method on the Methyl-Ethyl-Ketone Extraction of $^{99m}TcO^-{_4}$ ($^{99m}TcO^-{_4}$의 메틸-에틸-케톤-간편 추출법)

  • Lee, Jong-Du;Lee, Byung-Hyn
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.103-111
    • /
    • 1984
  • A convenient method of $^{99m}Tc$-methyl-ethyl-ketone (MEK) extraction technique was developed and a mobile $^{99m}Tc$-extraction generator was designed. The MEK extraction and the phase separation of $^{99m}TcO^-{_4}$ were carried out with a simple procedure in the same container. The shielding of $^{99}Mo$ radioactivity was made with one lead container. The system was simplified by shielding $^{99m}TcO_4{^-}({\gamma}_e=0.14\;MeV)$ separately. $^{99m}TcO^-{_4}\;in\;^{99m}Tc-MEK$ extract was recovered by adsorption and elution only, and therefore, the possibility of volatilization was reduced. The volume of $^{99m}TcO^{-}{_4}$-saline product was reduced to 1 ml by using a small alumina column and the column operation time was shortened. The separation time of $^{99m}Tc$ was reduced to 30 minutes, and the operation was carried out at the outside of the shielding. The system was designed to operate under the condition of bacteria-free.

  • PDF

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

Characteristics of Cu(II) Extraction by β-ketohexanal (β-ketohexanal에 의한 Cu(II)의 추출 특성)

  • Shin, Jeong-Ho;Lee, Sang-Hoon;Jeong, Kap-Seop;Park, Kyung-Kee;Jun, Sang-Woo
    • Applied Chemistry for Engineering
    • /
    • v.7 no.6
    • /
    • pp.1053-1060
    • /
    • 1996
  • $\beta$-ketohexanal as a chelating extractant was synthesized from the reaction of ethyl formate and methyl propyl ketone in the presence of sodium amide, and the equilibrium characteristics in the extraction of copper by $\beta$-ketohexanal-chloroform were investigated. The equilibrium constants such as the dissociation constant and the partition coefficients of $\beta$-ketohexanal, the stability constant and the partition coefficient of copper chelating complex, and the overall equilibrium constant in the extraction of copper were determined by spectrophotometric measurements, and the mechanism of extraction was proposed. The percent of extracted copper by $\beta$-ketohexanal-chloroform was near 100%, and the selective extraction of copper from Cu-Zn-Cd mixture was possible. Copper was found to be extracted as $CuR_2$ and the equilibrium reaction was expressed as $Cu^{2+}+2{\overline{HR}}{\rightleftarrows}{\overline{CuR{_2}}}+2H^+$.

  • PDF

Evaluation of Hybrid Thermal Oxidation(HTO) System for Removal of MEK(Methyl ethyl ketone) and Toluene (복합열산화(Hybrid Thermal Oxidation) 시스템을 이용한 MEK(Methyl ethyl ketone)와 Toluene 제거 평가)

  • Jang, Duhun;Bae, Wookeun;Kim, Moonil;Kim, Kyungtae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.31-37
    • /
    • 2010
  • In this study, optimization of MEK and Toluene removal was conducted by HTO(Hybrid Thermal Oxidation) system. HTO system has a multi-bed reaction plate and the plate consisted of wasted heat regeneration part and catalysis part. VOCs removal by HTO system was estimated by changing inlet flow rates with different valve changing times. Under $350^{\circ}C$ of combustion temperature, VOCs was fully converted and the equivalent conversion was 100%. The thermal oxidation efficiency, related to the amount of injected fuel into HTO system and the valve change time, was revealed at the level of 93.0~96.3%. In case of MEK removal by HTO system, the efficiency was ranged from 91.1 to 97.1%. Also, Toluene removal efficiency(93.2~97.4%) was good and stable with respect to the operating conditions. Considering above results, it was proved that HTO system could be a stable and compact system for VOCs, especially MEK and Toluene with high removal efficiency.

A Study on the Emission Characteristics of Odorous Substances in Korea (국내 화학물질 배출량 특성에 관한 연구: 악취물질 중심으로)

  • Im, JiYoung;Jeon, DaYoung;Kim, BoKyeong;Ryu, JiSung;Yoon, DaeSik;Lee, ChungSoo
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.5
    • /
    • pp.465-473
    • /
    • 2019
  • Objectives: A variety of industries handling hazardous chemicals emit odorous substances. Based on the emission characteristics of major odor substances from the results of hazardous chemical substance emissions, we will define basic data for improving the management methods of odorous substances. Methods: A survey of hazardous pollutant emissions for 2010-2016 was conducted through the Pollutant Release and Transfer Register homepage. Eight kinds of designated odor substances (ammonia, hydrogen sulfide, dimethyl disulfide, acetaldehyde, styrene, toluene, xylene, methyl ethyl ketone) provided the study subjects. The status of chemical accidents for the target substances was analyzed using the Chemistry Safety Clearing-house system. Results: From 2010 to 2016, it was found that more than 30% of businesses that emitted odorous substances accounted for more than 50% of the total emissions of the eight substances. Emissions of xylene, toluene, methyl ethyl ketone, and ammonia were found, in that order, and they made up more than 90% of the total emitted. By region, about 70% of odorous substances were emitted in the top-four regions: Gyeongsangnam-do Province, Ulsan, Gyeonggi-do Province, and Jeollanam-do Province. Conclusion: Recently, the amount of chemical emissions has been continuously increasing, including those that can cause odor. Odorous substances can be a serious risk to the lives of local residents. Systematic research is needed for the health protection of residents.

Emission Characteristics of VOCs Distributions in Semiconductor Workplace (반도체 작업환경의 VOCs 농도분포 특성)

  • Lee, Jeong Joo
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.503-509
    • /
    • 2018
  • In this study, a Proton-Transfer Reaction-Time-of-Flight Mass spectrometer (PTR-TOF-MS) was used for the continuous monitoring of Volatile Organic Compounds (VOCs) emitted from semiconductor workplace such as photolithography (PHOTO), flat panel display (FPD), organic light emitting diode (OLED), etching (WET) process. The averaged VOCs mixing ratio in the such workplace, PHOTO was 6.5 ppm, FPH was 6.4 ppm, WET was 2.0 ppm and OLED was 1.3 ppm, respectively. The abundance of VOCs in the workplace were methyl ethyl ketone (MEK) with 2.8 ppm (69%) and acetaldehyde with 0.5 ppm (13.2%). Depending on the semiconductor process characteristics, various VOCs have been observed in the workplace. The VOCs mixing ratio are lower than the workplace regulation standard (TWA), it is necessary to continuously monitor and effectively manage these VOCs.

Development of Passive Samplers for Volatile Organic Compounds (휘발성 유기화합물용 수동식 시료채취기 개발)

  • Miyeon, Jang;Gwangyong, Yi;Hyeonjin, Jeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.359-370
    • /
    • 2022
  • Objective: This study is intended to design a commercially available passive sampler and conduct performance test on its use as a media for evaluating a working environment. Methods: This study was conducted to select adsorbents, design models, and evaluate storage stability and sampling rates for the development of new types of passive samplers. Results: The impurity detection, adsorbent capacity and breakthrough volume of five types of activated carbon were tested for selection of an adsorbent. One product was selected in consideration of the efficiency of purchase. A number of passive samplers were designed in a radial style and a badge style using plastic as a material. The final two prototypes were made using molds or 3D printing. For the storage stability evaluation, samples were stored at different temperature for 1~21 days and then analyzed. Most of the chemicals had excellent storage stability when refrigerated. However, some chemicals such as dichloromethane and methyl ethyl ketone need to be analyzed as soon as possible after sampling. Conclusion: In this study, new types of passive samplers for 66 chemical compounds were developed. The evaluation of storage stability and sampling rates showed different results depending on the properties of the chemical substance. For some chemicals such as methyl ethyl ketone and dimethylformamide, activated carbon is inappropriate as an absorbent. In future studies, additional experiments are required on chemicals that are difficult to collect with activated carbon.