• 제목/요약/키워드: Method of Variation of Parameters

Search Result 993, Processing Time 0.033 seconds

Robust parameter set selection of unsteady flow model using Pareto optimums and minimax regret approach (파레토 최적화와 최소최대 후회도 방법을 이용한 부정류 계산모형의 안정적인 매개변수 추정)

  • Li, Li;Chung, Eun-Sung;Jun, Kyung Soo
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.3
    • /
    • pp.191-200
    • /
    • 2017
  • A robust parameter set (ROPS) selection framework for an unsteady flow model was developed by combining Pareto optimums obtained by outcomes of model calibration using multi-site observations with the minimax regret approach (MRA). The multi-site calibration problem which is a multi-objective problem was solved by using an aggregation approach which aggregates the weighted criteria related to different sites into one measure, and then performs a large number of individual optimization runs with different weight combinations to obtain Pareto solutions. Roughness parameter structure which can describe the variation of Manning's n with discharges and sub-reaches was proposed and the related coefficients were optimized as model parameters. By applying the MRA which is a decision criterion, the Pareto solutions were ranked based on the obtained regrets related to each Pareto solution, and the top-rated one due to the lowest aggregated regrets of both calibration and validation was determined as the only ROPS. It was found that the determination of variable roughness and the corresponding standardized RMSEs at the two gauging stations varies considerably depending on the combinations of weights on the two sites. This method can provide the robust parameter set for the multi-site calibration problems in hydrologic and hydraulic models.

Bioequivalence of Two Clarithromycin Tablets (클래리스로마애신 정제의 생물학적 동등성 평가)

  • 김종국;이사원;최하곤;고종호;이미경;김인숙
    • Biomolecules & Therapeutics
    • /
    • v.6 no.2
    • /
    • pp.219-224
    • /
    • 1998
  • The bioequivalence of two clarithromvcin products was evaluated with 16 normal male volunteers (age 23-28 yr, body weight 57.5-75.517g) following single oral dose. Test product was ReYon Clarithromycin tablets (ReYon Pharm. Corp., Korea) and reference product was Klarici $d_{R}$ tablets (Abbott Korea). Both products contain 250 mg of clarithromucin. One tablet of the test or the reference product was administered to the volunteers, respectively, by randomized two period cross-over study (2$\times$2 Latin square method). The determination of clarithromycin was accomplished using a modified agar well diffusion bioassay. As a result of the assay validation, the quantification of clarithromycin in human serum by this technique was possible down to 0.03$\mu$g/ml using 100$\mu$l of serum. The coefficient of variation (C.V.) was less than 10%. Average drug concentrations at each sampling time and pharmacokinetic parameters calculated were not significantly different between two products P>0.05); the area under the curve to last sampling time (24 hr) (AU $Co_{24hr}$ (8.10$\pm$ 1.26 vs 8.22$\pm$ 1.627g . hr/ml), AUC from time zero to infinite (AU $Co_{\infty}$) (8.61 $\pm$ 1.28 vs 8.84$\pm$ 1.71 $\mu$g . hr/ml), maximum plasma concentration ( $C_{msx}$) (0.87$\pm$0.22 vs 0.88$\pm$0.19 $\mu$g/ml) and time to maximum plasma concentration ( $T_{max}$) (2.69 $\pm$0.48 vs 2.56$\pm$ 0.51 hr). The differences of mean AU $Co_{24h}$, $C_{msx}$ and $T_{msx}$ between the two products (1.44, 1.39, and 4.65%, respectively) were less than 20%. The power (1-$\beta$) and treatment difference ($\Delta$) for AU $Co_{24hr}$, and $C_{max}$ were more than 0.8 and less than 0.2, respectivly. Although the power for $T_{max}$ was under 0.8, $T_{max}$. of the two products was not significantly different each other (p>0.05). These results suggest that the bioavailability of ReYon Clarithromycin tablets is not significantly different from that of Klarici $d_{R}$ tablets. Therefore, two products are bioequivalent based on the current results. results.sults.sults.s.s.s.s.s.s.s.

  • PDF

Nonlinear Finite Element Analysis of the Reinforced Concrete Panel using High-Strength Reinforcing Bar (고강도 철근을 사용한 철근콘크리트 패널의 비선형 유한요소해석)

  • Cheon, Ju-Hyun;Seong, Dae-Jung;Cho, Hong-Jae;Cho, Jae-Yeol;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.481-488
    • /
    • 2015
  • The purpose of this study is to provide analytical method to reasonably predict the overall behavior up to destruction of reinforced concrete panel specimens using high-strength reinforcing bar. A total of 12 specimens of reinforced concrete panels with a wall thickness one-third the size of the actual nuclear containment structures under various loading conditions and design parameters were selected and the analysis was performed using a non-linear finite element analysis program (RCAHEST) was developed by the authors. The mean and coefficient of variation for shear strength at cracking point and maximum shear strength from the experiment and analysis results was predicted 1.03 and 12%, 0.97 and 9%, respectively. For the shear strain at the maximum shear strength from the experiment and analysis results was predicted 0.96 and 30%, respectively. Based on the results, the analysis program that was applied newly modified constitutive equation in this study is judged as having a relatively high reliability for the analysis results.

Distributions of Hyperfine Parameters in Amorphous $Fe_{83}B_9Nb_7Cu_1$ Alloys (비정질 $Fe_{83}B_9Nb_7Cu_1$의 M$\)

  • 윤성현;김성백;김철성
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.6
    • /
    • pp.271-277
    • /
    • 1999
  • Amorphous $Fe_{83}B_9Nb_7Cu_1$ alloy has been studied by M$\"{o}$ssbauer spectroscopy. Revised Vincze method was used and distributions of hyperfine field, isomer shift, and quadrupole line broadening of the sample at various temperatures have been evaluated and Curie temperature and $H_{hf}\;(0)$ were calculated to be 393 K and 231 kOe, respectively. Temperature variation of reduced average hyperfine field shows a flattered curvein comparison with the Brillouin curve for S=1. This behavior can be explained on the basis of Handrich molecular field model, in which the parameter Δ, which is a measure of fluctuation in exchange interactions, is assumed to have the temperature dependence ${Delta}=0.75-0.64{\tau}+0.47{\tau}^2$ where $\tau$ is $T/T_C$. At low temperature, the average hyperfine field can be fitted to $H_{hf}\;(T)=H_{hf}\;(0)\;[1-0.44\;(T/T_C)^{3/2}-0.28(T/T_C)^{5/2}-… ]$, which indicates the presence long wave length spin wave excitations. At temperature near TC, reduced average hyperfine field varies as $1.00\;[1-T/T_C]^{0.39}$. It is also found that half-width of the hyperfine field distribution was 102 kOe (3.29 mm/s) at 13 K and decreased monotonically as temperature increased. Above the Curie temperature, an average quadrupole splitting value of 0.43 mm/s was found. Average line broadening due to quadrupole splitting distribution was 0.31 mm/s at 13 K and decreases monotonically to 0.23 mm/s at 320 K, whereas that due to the isomer shift distribution is 0.1 mm/s at 13 K and 0.072 mm/s at 320 K, which is much smaller than that of both hyperfine field and quadrupole splitting. The temperature dependence of the isomer shift can be fitted within the harmonic approximation to a Deybe model with a Debye temperature ${Theta}_D=424{\pm}5K$.TEX>.

  • PDF

Variation of strength of soil matrix with artificially manipulating particle distribution of granular soil (인위적 입도조정에 따른 지반의 강도특성 변화)

  • Moon, Jun-Ho;Xin, Zhen-Hua;Kim, Gab-Boo;Moon, Sun-Mi;Kim, Young-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.56-62
    • /
    • 2018
  • In this study, an artificially formed Gap graded soil, designed to increase its shear strength, was analyzed to determine the strength parameters through direct shear tests. Uniform and fine grain size samples were compared to the Gap graded soil to investigate the increase in the shear strength. Plate loading tests were conducted using 13mm and 19mm aggregates to confirm the reproducibility of the strength enhanced samples for site application. This test confirmed that the particle size ratio and the internal friction angle are correlated to the shear strength, and the shear resistance angle significantly increased in the specific particle size ratio range. The calculation of the ultimate bearing capacity by the plate load test demonstrated that the grain size adjustment method greatly influences the strength increase rate. Therefore, the findings were verified and it was confirmed that a high shear strength is achievable despite the existence of a poor particle size distribution.

Optical Properties and Structural Analysis of SiO2 Thick Films Deposited by Plasma Enhanced Chemical Vapor Deposition (PECVD법에 의해 증착된 SiO2 후막의 광학적 성질 및 구조적 분석)

  • Cho, Sung-Min;Kim, Yong-Tak;Seo, Yong-Gon;Yoon, Hyung-Do;Im, Young-Min;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.479-483
    • /
    • 2002
  • Silicon dioxide thick film using silica optical waveguide cladding was fabricated by Plasma Enhanced Chemical Vapor Deposition(PECVD) method, at a low temperature ($320^{\circ}$C) and from $(SiH_4+N_2O)$ gas mixtures. The effects of deposition parameters on properties of $SiO_2$ thick films were investigated by variation of $N_2O/SiH_4$ flow ratio and RF power. After the deposition process, the samples were annealed in a furnace at $1150^{\circ}$C, in N2 atmosphere, for 2h. As the $N_2O/SiH_4$ flow ratio increased, deposition rate decreased from 9.4 to 2.9 ${\mu}m/h$. As the RF power increased, deposition rate increased from 4.7 to 6.9 ${\mu}m/h$. The thickness and the refractive index measurements were measured by prism coupler. X-ray Photoelectron Spectroscopy(XPS) and Fourier Transform-infrared Spectroscopy(FT-IR) were used to determine the chemical states. The cross-section of films was observed by Scanning Electron Microscopy(SEM).

Study on the simulation of a spark ignition engine using BOOST (상용 소프트웨어를 이용한 스파크 점화 기관의 시뮬레이션에 관한 연구)

  • Jeong, Chang-Sik;Woo, Seok-Keun;Ryu, Soon-Pil;Yoon, Keon-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.733-742
    • /
    • 2016
  • In recent years, gas engines fueled with LNG or synthetic gas have been attracting considerable attention for marine use owing to their potential to facilitate better fuel economy and to reduce emissions. It has been confirmed that gas engines using the Otto cycle, which involves premixed combustion, can satisfy Tier III regulations without the EGR or SCR system. The objective of this study is to acquire simulation technologies for predicting gas engine performances in industrial fields. Using the commercial software BOOST, the simulation is conducted on a gasoline engine rather than a marine engine due to the gasoline engine's easier accessibility. This study consists of two stages. In the first stage published previously, the optimal modeling techniques for representing the behavior of the gas in the intake and exhaust systems were determined. In the current study, we formulated a method to evaluate the combustion and heat transfer processes in the cylinder and to ultimately determine the major performance parameters, given that the analytical model derived from the previous stage has been applied. Through this study, we were able to determine a combustion and heat transfer model and a valve discharge coefficient that are less reliant on empirical data: we were also able to formulate a methodology through which relevant constants are decided. We confirmed that the values of transient cylinder pressure variation, indicated mean effective pressure, and air supply can be successfully predicted using our modeling techniques.

Mössbauer Study on the Variation in Magnetic Properties of CuO Induced by 57Fe Addition (57Fe 이온이 CuO에 미치는 효과에 관한 Mössbauer 분광 연구)

  • Park, Jae-Yun;Kim, Kwang-Joo
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.3
    • /
    • pp.113-119
    • /
    • 2009
  • $^{57}Fe_xCu_{1-x}O$(x = 0.0, 0.02) powders were prepared by sol-gel method and their crystallographic and magnetic hyperfine properties have been studied using X-ray diffraction and $M{\ddot{o}}ssbauer$ spectroscopy (MS). The crystal structure of the samples is found to be monoclinic without any secondary phases and their lattice parameters increase with increasing annealing temperature ($T_A$), which is attributed to an increase in oxygen-vacancy content. MS measurements at room temperature indicate that $Fe^{3+}$ ions substitute $Cu^{2+}$ sites and ferromagnetic phase grow with increasing $T_A$. Magnetic hyperfine and quadrupole interactions of $^{57}Fe_{0.02}Cu_{0.98}O$ ($T_A=500^{\circ}C$) in the antiferromagnetic state at 17 K have been studied, yielding the following results: $H_{hf}=426.94\;kOe$, ${\Delta}E_Q=-3.67\;mm/s$, I.S.=0.32 mm/s, ${\theta}=65^{\circ}$, ${\phi}=0^{\circ}$, and ${\eta}=0.6$.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Evaluation of Sperm Penetration Ability according to Various Morphological Characteristics of Spermatozoa (정자의 여러가지 형태학적 특징에 따른 정자 침투능의 평가)

  • Kim, J.H.;Jung, K.W.;Lew, Y.O.;Kwon, D.J.;Lim, Y.T.;Kim, J.H.;Nha, D.J.;Lee, J.W.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.21 no.1
    • /
    • pp.31-41
    • /
    • 1994
  • Morphological estimation of human spermatozoa is complicated by the fact that there is great natural variation in shape. This natural variation in shapes makes it difficult to say which forms are associated with infertility and which are normal variations. Possibly post coital test or in vitro cervical mucus penetration tests will help to clarify this question by showing which sperm are capable of penetration. The purpose of this investigation was performed to assess distribution of various morphological abnormalities according to the ability of sperm to penetrate cervical mucus. The sperm-mucus penetration using hen's egg white as substituting mucus for human cervical mucus was done in 45 fertile men with normal semen analysis and 122 infertile men with abnormal seminal parameters more than one. The female partners of 122 infertile couples showed normal results in the female fundamental test for fertility. Conventional semen analysis was evaluated according to the WHO standard normal(l980). The detailed classification of the abnormal sperm was made according to David et al(l975). The vitality of the sperm samples determined by eosin yellow-nigrosin stainig according to the method of Eliasson(l977). Results were as follw; 1. The patients had significantly lower total sperm count, motility (%), normal morphology (%), viability and total functional sperm fractions(TFSF) than fertile donors. 2. The mean value of sperm penetration distance of the patients(28.69${\pm}$11.02mm) showed significantly lower than fertile donors(37.33${\pm}$5.49mm). And 43/45 fertile donors(95.5%) as well as 57/122 patients(46.7%) had over 30mm in sperm penetration distance respectively. While 2/45 fertile donors(4.5 %) and 65/122 patient(53.3%) had under 30mm in sperm penetration distance respectively. 3. The morphological abnormalities in fertile donors were significantly lower 23.04${\pm}$5.83% (head = 12.89${\pm}$4.98, neck=6.11${\pm}$3.83%, and tail=3.43${\pm}$2.65%), compared to 36.03${\pm}$14. 40% in patients(head = 15.98 8.60%, neck 11.20${\pm}$6.56% and tail=8.70${\pm}$6.55%). Also, 3 types of sperm abnormalities including head, neck and tail were significantly lower in patient than fertile donors, respectively. Both the patients and fertile donors showed higher distribution of sperm with abnormal head than abnormal neck and tail. 4. The mean morphological abnormalities(SP>30mm) of the patients(30.68 11.64%; head = 15.95${\pm}$9.35%, neck=8.14${\pm}$4.21 %, tail=6.56${\pm}$5.64%) were significantly lower compared to patients(40.72${\pm}$15.01 %; head=16.02${\pm}$7.69%, neck 13.89${\pm}$7.82%, tail=1O.58${\pm}$6.75%) under 30mm in sperm penetration distance. Also, both groups over 30mm and under 30mm in sperm penetration showed distance higher distribution of sperm with abnormal head than abnormal neck and tail. The morphological abnormalities of head did not show significant difference but abnormal neck and tail were significant difference between the over 30mm and under 30mm group in sperm penetration distance.

  • PDF