• Title/Summary/Keyword: Metal level

Search Result 1,631, Processing Time 0.032 seconds

Effects of Acute Metal Exposures on the Viability and mRNA Expression of Metallothionein in Hemibarbus mylodon Fry

  • Bang, In-Chul;Cho, Young-Sun;Lee, Il-Rho;Nam, Yoon-Kwon
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.4
    • /
    • pp.489-494
    • /
    • 2007
  • Transcriptional modulation of metallothionein (MT) during acute metal exposures (cadmium, copper or zinc) was examined in fry of Hemibarbus mylodon, a threatened fish species in Korean peninsula. Viability of H. mylodon fry was most affected by copper exposure (up to 79% of mortality at 1 ppm for 48 hours) and considerably by cadmium exposure (21 to 54% of mortality). On the other hand, Zn showed the least adverse effect on the viability (0 to 13% of mortality) of this species. Based on the semi-quantitative RT-PCR analysis, the stimulation of MT mRNA in response to metal exposures followed generally in a dose-dependent fashion where cadmium was the most potent inducer for the induction of MT transcripts in fry (up to more than 5-fold) while the lowest response was observed in zinc-exposed group (2-fold at maximum). From the exposure using environmentally realistic doses of cadmium (0 to 0.05 ppm for 24 hours), MT expression at mRNA level was also sensitively modulated toward upregulation up to more than 3-fold as relative to non-exposed control. Results from the present study would be a good basis for understanding the adaptive capacity and stress physiology of this endangered fish species during metal pollution.

Distribution of heavy metal contamination in soils and sediments in the vicinity of the Hwacheon Au-Ag-Pb-Zn mine

  • Lee Sung-Eun;Lee Jin-Soo;Chon Hyo-Taek
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.529-531
    • /
    • 2003
  • In order to investigate the level of heavy metal contamination and the seasonal variation of metal concentrations in soils and sediments influenced by past mining activities, tailings, soil and sediment samples were collected from the Hwacheon mine in Korea. The main pollution sources in this mine site are suggested as tailings and mine waste rocks. Elevated levels of Cd, Pb and Zn were found in soils and sediments. In a study of seasonal variation on the heavy metals in soils and sediments, heavy metals were higher enriched collected from before rainy season ($2^{nd}$ sampling) than after rainy season ($1^{st}$ sampling). Also, in order to estimate the microbial effects on Cd speciation in sediments, bacteria which can adsorb Cd was isolated and Cd adsorption characteristics of isolated bacteria in Cd solution was evaluated. The Cd bioremoval efficiency in Cd solution (5 ppm) by bacteria was more than $90\%$. Bioremoval efficiency in single metal solution was higher than that in mixed metal solution of Pb and Zn.

  • PDF

A Study on Contents of Heavy and Trace Metal of the Agricultural Products around Mines Located in Chollanam-Do - with Yeongam, Boseong, Gokseong, Yeocheon Gun in the Center - (전라남도 광산 주변에서 수확한 농산물 충의 중금속 및 미량금속 함량 조사 - 영암, 보성, 곡성, 여천군을 중심으로 -)

  • 박정숙;이미경
    • The Korean Journal of Food And Nutrition
    • /
    • v.15 no.1
    • /
    • pp.64-69
    • /
    • 2002
  • To know a degree of pollution in agricultural products cultivated around 4 unworked mines located in Chollanam-Do, we investigated a concentration of heavy metal and trace metal to provide the basic data for its residual limits. 28 samples of seven kinds of agricultural products(lettuce, onion, potato, radish, pepper, pumpkin, bean) collected from 4 unworked mines located in Chollanam-Do in 2001 were analyzed by Mercury Analyzer for mercury and Atomic Absorption spectrophotometer for Pb, As, Cd, Cu, Mn, and Zn. Hg contents were detected N.D. ∼trace level(0.01 ppm and less) and As content were detected N.D. ∼ 0.029 lpm but most of same)leE were not detected. Cd contents were detected N.D∼0.124 ppm. The results of Hg, As, Pb and Cd content showed that for all the 7 species of agricultural products studied, none have accumulated levels dangerous enough to Pose health problems. The average contents of Cu were 3.070 ∼ 7.825 ppm in bean, the Mn were 3.688 ∼23.935 ppm in lettuce ailed the Zn were 5.690 ∼21.171 ppm in bean, respectively.

Production of Ultra-fine Metal Powder with Gas Atomization Processes

  • Wang, M. R.
    • Journal of ILASS-Korea
    • /
    • v.11 no.2
    • /
    • pp.59-68
    • /
    • 2006
  • Experimental results of the metal powder production with internal mixing, internal impinging and the atomizer coupled with substrate design are presented in this paper. In a test with internal mixing atomizer, mean powder size was decreased from $37{\mu}m\;to\;23{\mu}m$ for Pb65Sn35 alloy as the gas-to-melt mass ratio was increased from 0.04 to 0.17. The particle size further reduces to $16.01{\mu}m$ as the orifice area is increased to $24mm^2$. The micrograph of the metal powder indicates that very fine and spherical metal powder has been produced by this process. In a test program using the internal impinging atomizers, the mean particle size of the metal powder was decreased from $22{\mu}m\;to\;12{\mu}m$ as the gas-to-melt-mass ratio increased from 0.05 to 0.22. The test results of an atomizer coupled with a substrate indicates that the deposition rate of the molten spray on the substrate is controlled by the diameter of the substrate, the height of the substrate ring and the distance of the substrate from the outlet of the atomizer. This in rum determines the powder production rate of the spraying processes. Experimental results indicate that the deposition rate of the spray forming material decreases as the distance between the substrate and the atomizer increases. For example, the deposition rate decreases from 48% to 19% as the substrate is placed at a distance from 20cm to 40cm. On the other hand, the metal powder production rate and its particle size increases as the subsrate is placed far away from the atomizer. The production of metal powder with mean particle size as low as $3.13{\mu}m$ has been achieved, a level which is not achievable by the conventional gas atomization processes.

  • PDF

Effect of Metal Components in Seminal Plasma on Seminal Parameter and Male Fertile Ability (정장액내의 금속성분이 정액지표 및 가임능에 미치는 영향)

  • Park, Nam-Cheol;Kim, Min-Soo;Yoon, Jong-Byung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.1
    • /
    • pp.67-81
    • /
    • 1997
  • To determine the concentration and the physiologic role of metal components in blood plasma and seminal plasma in relation to male infertility, the concentrations of twelve metal components in blood plasma and seminal plasma including Na, Mg, K, Ca, Cr, Mn, Fe, Cu, Zn, Se, Cd and Pb were measured by atomic absorbance spectrophotometery or ion selective electrode analysis. Semen and blood samples were obtained from a total of 110 men including 70 male infertility patients, 20 vasectomized persons and 20 fertility proven volunteers visited to the Male Infertility Clinic of Pusan National University Hospital. The concentrations of Ca, Zn, Mg, Cr and Cd in control group were higher in seminal plasma than in blood plasma, and additionally Pb were higher in infertility group. The concentrations of all metal components revealed no significant difference according to patients' age, resident, occupation, sperm density, motility and hormone level in blood plasma, but some metal components including Ca, Mg, Cu, Mn, Cd and Pb revealed a significant difference according to each these parameters except patient's age in seminal plasma. The concentrations of Mn, Cd and Pb in the vasectomy persons were higher than in the infertility group III including testicular and epididymal factors, but not in blood plasma. We conclude that the quantitative changes of metal components in the seminal plasma may have effects on not only spermatogenesis and sperm function, but also contribute to diagnostic parameter according to organ specificity of the metal in the male reproduction.

  • PDF

Heavy Metal Contents In Tissues of Carassius auratus In Andong and Imha Reservoir (안동.임하호에 서식하는 붕어(Carassius auratus) 조직 내 중금속 함량)

  • Kim, Jeong-Sook;Shin, Myung-Ja;Lee, Jong-Eun;Seo, Eul-Won
    • Journal of Life Science
    • /
    • v.19 no.11
    • /
    • pp.1562-1567
    • /
    • 2009
  • Heavy metal contamination levels in Andong reservoir and Imha reservoir were measured with heavy metal contents in both water and sediment, and analyzed with heavy metal accumulation level in inhabitant fish, Carassius auratus, using an inductively coupled plasma spectrometer and an atomic absorption spectrometer. High levels of heavy metal contents in water, sediment and the tissues of C. auratus were detected. Likewise, relatively high levels of As were detected in water and sediment from Andong reservoir. In addition, higher levels of Cr, Cu, Cd and As content were detected in muscle and bone tissues of fish from Andong reservoir than those from Imha reservoir. As a result, the heavy metal content of water, sediment and inhabitant fish, C. auratus, in Andong reservoir was higher than Imha reservoir. We proposed that heavy metal contamination in water and inhabitant fish is attributed to various metals derived from abandoned mines and farmlands that are upstream of Andong reservoir.

COMPARATIVE STUDY OF SHEAR BOND STRENGTH BETWEEN CP-TI/CO-CR ALLOY AND COMPOSITE RESINS

  • Yoon, Se-Hee;Pae, Ahran;Lee, Seok-Hyung;Lee, Ho-Rim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.6
    • /
    • pp.805-814
    • /
    • 2007
  • Statement of problem. Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework, various surface treatment methods have been introduced to improve the bond strength. Purpose. The object of this study was to compare the shear bond strength of different combinations of each of the two bonding systems and each of the two composite veneering resins to cp-Ti/Co-Cr alloy. Material and methods. Two resin bonding systems (metal conditioner containing MEPS monomer, tribochemical silicoating system) and two composite resins (Gradia, Sinfony) were tested on cp-Ti and Co-Cr alloy. Then, according to manufacturers' instructions, resin bonding systems and composite resins were applied. All test specimens were divided into four groups for each alloy; I) sandblast + Metal Primer II + Gradia (MG), II) sandblast + Metal Primer II + Sinfony (MS), III) Rocatec + Gradia (RG), IV) Rocatec + Sinfony (RS). The shear bond strength was determined using a universal testing machine and all data were statistically analyzed with Mann-Whitney test and Kruskal-Wallis test at the significance level of 0.05. Results. The mean (standard deviations) of shear bond strength according to the combinations of two bonding systems and two composite resins to cp-Ti arranged from 16.44 MPa to 17.07 MPa and the shear bond strength to Co-Cr alloy ranged from 16.26 MPa to 17.70 MPa. The result shows that the difference were not statistically significant. Conclusion. The shear bond strengths of composite resins to both cast cp-Ti and Co-Cr alloy were not significantly different between the metal conditioner and the tribochemical silicoating system. And no differences in bond strength were found between cp-Ti and Co-Cr alloy.

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교)

  • Kang, Min-Kyung;Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.