• Title/Summary/Keyword: Metal ceramics restorations

Search Result 20, Processing Time 0.026 seconds

악성암종 수술 환자에서 임시수복물로서 Targis-Vectris의 응용 (Application of Targis-Vectris Provisional Restorations for an Oro-Maxillofacial Cancer Patient: A Case report)

  • 김진만;한중석;이선형;양재호;이재봉
    • 구강회복응용과학지
    • /
    • 제18권2호
    • /
    • pp.113-118
    • /
    • 2002
  • Long bridge가 필요한 구강암종환자에게 자기공명영상을 촬영하여야 하는 경우, fiber reinforced polymer ceramics로 잠정보철물을 제작해준 경우 충분한 파절 저항성과 심미성을 얻을 수 있었다. 하지만, 여기에 대한 장기간의 연구와 관찰이 필요하리라 사료된다.

In vitro evaluation of the bond strength between various ceramics and cobalt-chromium alloy fabricated by selective laser sintering

  • Bae, Eun-Jeong;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.312-316
    • /
    • 2015
  • PURPOSE. This study aimed to present the clinical applicability of restorations fabricated by a new method, by comparing the bond strength of between ceramic powder with different coefficient of thermal expansion and alloys fabricated by Selective laser sintering (SLS). MATERIALS AND METHODS. Fifty Co-Cr alloy specimens ($25.0{\times}3.0{\times}0.5mm$) were prepared by SLS and fired with the ceramic ($8.0{\times}3.0{\times}0.5mm$) (ISO 9693:1999). For comparison, ceramics with different coefficient of thermal expansion were used. The bond strength was measured by three-point bending testing and surfaces were observed with FE-SEM. Results were analyzed with a one-way ANOVA (${\alpha}$=.05). RESULTS. The mean values of Duceram Kiss ($61.18{\pm}6.86MPa$), Vita VM13 ($60.30{\pm}7.14MPa$), Ceramco 3 ($58.87{\pm}5.33MPa$), Noritake EX-3 ($55.86{\pm}7.53MPa$), and Vintage MP ($55.15{\pm}7.53MPa$) were found. No significant difference was observed between the bond strengths of the various metal-ceramics. The surfaces of the specimens possessed minute gaps between the additive manufactured layers. CONCLUSION. All the five powders have bond strengths higher than the required 25 MPa minimum (ISO 9693); therefore, various powders can be applied to metal structures fabricated by SLS.

Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.179-186
    • /
    • 2013
  • PURPOSE. One of the most important factors in evaluating the quality of fixed dental prostheses (FDPs) is their gap. The purpose of this study was to compare the marginal and internal gap of two different metal-ceramic crowns, casting and selective laser sintering (SLS), before and after porcelain firing. Furthermore, this study evaluated whether metal-ceramic crowns made using the SLS have the same clinical acceptability as crowns made by the traditional casting. MATERIALS AND METHODS. The 10 study models were produced using stone. The 20 specimens were produced using the casting and the SLS methods; 10 samples were made in each group. After the core gap measurements, 10 metal-ceramic crowns in each group were finished using the conventional technique of firing porcelain. The gap of the metal-ceramic crowns was measured. The marginal and internal gaps were measured by two-dimensional and three-dimensional replica techniques, respectively. The Wilcoxon signed-rank test, the Wilcoxon rank-sum test and nonparametric ANCOVA were used for statistical analysis (${\alpha}$=.05). RESULTS. In both groups, the gap increased after completion of the metal-ceramic crown compared to the core. In all measured areas, the gap of the metal cores and metal-ceramic crowns produced by the SLS was greater than that of the metal cores and metal-ceramic crowns produced using the casting. Statistically significant differences were found between cast and SLS (metal cores and metal-ceramic crown). CONCLUSION. Although the gap of the FDPs produced by the SLS was greater than that of the FDPs produced by the conventional casting in all measured areas, none exceeded the clinically acceptable range.

Pressable Ceramic을 이용한 심미보철

  • 김종진
    • 대한심미치과학회지
    • /
    • 제10권1호
    • /
    • pp.72-78
    • /
    • 2001
  • To maintain the strength obtained with metal ceramic restorations, excellent gradient of translucency, wear resistance in the same range as enamel and good marginal integrity, all ceramics have been developed with many advantages in recent years. Authentic (Ceramay, Germany) is a type of low fusing, leucite-reinforced pressable ceramic that allows both the laying technique and the staining technique or the combination of the two. Two-phase glass ceramic will allow achieving unmatched esthetics even with the simplest laying or staining technique. The ingots and laying porcelain come in Vita shades. Case selection has to be the most crucial thing to achieve optimal esthetics, and cooperation with technician has to be emphasized to satisfy patient's highest esthetic demands.

  • PDF

선택적 레이저 용융 그리고 전통적인 주조 기술에 의해 제조된 Co-Cr 합금에 대한 전장용 세라믹의 전단 결합 강도 비교 (Comparison of Shear Bond Strength of Veneer Ceramics to Co-Cr Alloys Produced by Selective Laser Melting and Casting Technique)

  • 홍민호
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.434-439
    • /
    • 2020
  • 최근, 치과 산업에서 레이저를 열원으로 합금을 제조하는 선택적 레이저 용융법(Selective laser melting, SLM)이 소개되고 있다. 하지만 SLM으로 제작된 금속-세라믹 수복물에 대한 연구가 부족한 실정이다. 따라서 본 연구의 목적은 SLM 그리고 CAST(casting)에 의해 제조된 Co-Cr 합금의 금속-세라믹(metal-ceramic) 결합 강도(bond strength)를 평가하는 것이다. SLM 그리고 CAST 방법을 사용하여 Co-Cr 시편을 제조하고 세라믹을 소결하여 시료를 제작하였다. 연구의 실험은 표본 준비 및 분석을 통해 2020년 1월부터 6월까지 수행되었다. 금속-세라믹 결합 강도는 만능 시험기에 의해 측정되었다. 부착 세라믹의 면적분(The area fraction of adherence ceramic, AFAC)은 SEM/EDS로 시편의 Si 함량을 측정하였다. 금속-세라믹 결합 강도 및 AFAC 결과는 t-test를 사용하여 분석하였다(α = .05). SLM 그리고 CAST Co-Cr 합금 사이의 결합 강도에 대해서는 유의한 차이가 발견되지 않았다(P>.05). SLM은 CAST 그룹보다 많은 세라믹 부착성(ceramic adherence)을 나타냈다(P<.001). 세라믹과 합금의 결합 강도는 제조 방법엥 영향을 받지 않았다. 그러나 SLM은 더 우수한 세라믹 부착성을 보였다. 이는 향후 임플란트 상부 보철물 제작에도 SLM으로 제작한 합금이 사용 가능한 것을 시사한다. CAST 방식의 단점을 극복하고 시간과 비용을 절약할 수 있을 것으로 기대된다.

In vitro study of compressive fracture strength of Empress 2 crowns cemented with various luting agents

  • Kim Min-Ho;Yang Jae-Ho;Lee Sun-Hyung;Chung Hun-Young;Chang Ik-Tae
    • 대한치과보철학회지
    • /
    • 제39권3호
    • /
    • pp.260-272
    • /
    • 2001
  • All-ceramic restorations have had a more limited life expectancy than metal ceramic restorations because of their low strength. Their relatively lower strength and resistance to fracture have restricted the use of all-ceramic crowns to anterior applications where occlusal loads are lower. But there has been increasing interest in all-ceramic restorations because patients are primarily concerned with improved esthetics. Many efforts have been made to in prove the mechanical properties of dental ceramics. This study was designed to elucidate the influence of the luting agent on the strength of the Empress 2 crown (staining technique) cemented on human teeth. Seventy extracted human permanent molar teeth were chosen. Teeth were prepared for Empress 2 crowns with milling machine on a surveyor. A dental bur was placed in the mandrel that was positioned so that the long axis of the bur was perpendicular to the surveyor base. Dimensions of the Empress 2 crown preparation were $6^{\circ}$ taper on each side, $1.5{\pm}0.1mm$ shoulder margin, and 4mm crown height. The luting cements used in this study were as follow: 1. Uncemented 2. Zinc phosphate cements (Confi-Dental) 3. Conventional glass ionomer cement : Fuji 1 (GC) 4. Resin-modified glass ionomer cements : Fuji plus (GC) 5. Adhesive cements : Panavia F (Kuralay), Variolink II (Vivadent), Choice (Bisco). Fracture test using Instron. The crowns were loaded in compressive force to evaluate the effect of these cements on the breaking strength of these all-ceramic crowns. A steel ball with a diameter of 4mm was placed on the occlusal surface and load was applied to the steel ball by a cylindrical bolt with a crosshead speed of 0.5mm per minute until fracture occurred. The fractured surface was examined using Scanning Electron Microscopic Image (SEM) to discover the correlation between fracture strength and bonding capacity. Within the limitation of this in vitro study design, the results were as follows : 1. fomentations significantly increased the fracture resistance of Empress ceramic crowns compared to control. Uncemented (206.9 N): ZPC (812.9 N): Fuji 1 (879.5 N): Fuji Plus (937.7 N): Choice (1105.4 N): Variolink II (1221.1 N): Panavia F (1445.2 N). 2. Resin luting agent, treated by a silane bond enhancing agents, yielded a significant increase in fracture resistance. In some of the Panavia F group, a fracture extended into dentin. 3. According to SEM images of fractured Empress crowns, the stronger the bond at both interfaces(crown and die), the more fracture strength was acquired.

  • PDF

다용도 프라이머가 레진 시멘트와 수복재의 전단 결합 강도에 미치는 영향 (Effect of universal primer on shear bond strength between resin cement and restorative materials)

  • 김나홍;심준성;문홍석;이근우
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.112-118
    • /
    • 2012
  • 연구 목적: 이 연구의 목적은 실란과 인산 모노머를 혼합한 프라이머인 Monobond plus (Ivoclar Vivadent, Schaan, Liechtenstein)를 사용했을 때 레진 시멘트와 수복물 간의 전단 결합 강도가 귀금속, 비귀금속, 글라스 세라믹과 지르코니아 네 가지 재료 모두에서 기존의 프라이머를 사용했을 때의 결합 강도와 비교하여 유의한지 평가하는 것이다. 연구 재료 및 방법: 디스크 모양(${\phi}\;9mm{\times}3mm$)의 귀금속(Argedent Euro) 시편 16개, 비귀금속(T-4) 시편 20개, 지르코니아(Cercon) 시편 20개, 글라스 세라믹(IPS e.max press) 시편 20개를 제작한 후 아크릴릭 레진(${\phi}\;15mm{\times}15mm$)에 포매하였다. 귀금속 시편에 airborne-particle abrasion을 시행하고 대조군으로 사용한 8개 시편에는 귀금속용 프라이머(Metal primer II)를, 나머지 8개 시편에는 Monobond plus를 도포하였다. 비귀금속 시편과 지르코니아 시편은 airborne-particle abrasion 후 각각 두 그룹으로 나누어 대조군 10개 시편에는 비귀금속 및 지르코니아용 프라이머(Alloy primer)를, 나머지 10개에는 Monobond plus를 도포하였다. 글라스 세라믹 시편은 4% 불산으로 부식한 후, 대조군 10개 시편에는 실란(Monobond-S)을, 나머지 10개에는 Monobond plus를 적용했다. 표면 처리된 시편 위에 디스크 형태(${\phi}\;5mm{\times}2mm$)로 레진 시멘트(Multilink N)를 위치시키고 중합하였다. 제작된 모든 시편을 열순환($5^{\circ}C$$55^{\circ}C$, 1분씩 2060회)시킨 후 전단 결합 강도를 측정하였다. 전단 결합 강도의 유의차를 살펴보기 위해 Shapiro-Wilk test를 이용하여 모집단의 분포에 대한 검정을 하고 그 결과에 따라 Two sample $t$-test 또는 Mann-Whitney U test를 실시하였다(${\alpha}$=.05). 파절된 시편을 확대경으로 관찰하여 그 양상을 분류하였다. 결과: 귀금속과 글라스 세라믹 군에서는 두 프라이머간의 전단 결합 강도에 유의한 차이가 존재하지 않았으나($P$>.05) 비귀금속 군과 지르코니아 군에서는 기존 프라이머(Alloy primer)를 사용했을 때 레진 시멘트와 수복물간의 전단 결합 강도가 Monobond plus를 사용한 군보다 통계적으로 유의하게 높았다(비귀금속 군$P$=.004, 지르코니아 군$P$=.001). 결론: 실란과 인산 모노머를 혼합한 다용도 프라이머는 귀금속과 글라스 세라믹 군에서는 기존의 프라이머를 대신하여 사용할 수 있을 것이다. 그러나 비귀금속과 지르코니아 세라믹에서는 10-MDP 프라이머에 비해 접착 강도가 낮아 기존 프라이머를 대신하여 적용하기 위해서는 좀 더 연구가 필요할 것이다.

CAD/CAM 세라믹 인레이로 수복한 치아의 응력분포에 관한 유한요소법적 연구 (FINITE ELEMENT STRESS ANALYSIS OF A TOOTH RESTORED WITH CAD/CAM CERAMIC INLAY)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제26권6호
    • /
    • pp.464-484
    • /
    • 2001
  • When restoring a tooth, the dentist tries to choose the ideal material for existing situation. One criterion that is considered is its suitability for restoring coronal strength. As more tooth structure is removed, the cusps are weakened and susceptible to fracture. Further, this increased deformation may cause the formation of intermittent gaps at the margin between the hard tissue and the restoration, facilitating marginal leakage. The improvements in ceramic materials now make it possible for alternatives to amalgams, composites, and cast metal to be of offered for posterior teeth. Of the materials used, ceramics most closely approximates the properties of enamel. The introduction of computer-aided design/computer-aided manufacture(CAD/CAM) systems to restorative dentistry represents a major technological breakthrough. It is possible to design and fabricate ceramic restorations at a single appointment. Additionally, CAD/CAM systems eliminate certain errors and inaccuracies that are inherent to the indirect method and provide an esthetic restoration. The aim of this investigation was to study the loading characteristics of CAD/CAM ceramic inlay and to compare the stress distribution and displacement associated with different designs of cavity(the isthmus width and cavity depth). A human maxillary left first premolar was prepared with standard mesio-occlusal cavity preparation, as recommended by the manufacturer Ceramic inlay was fabricated with CEREC 2 CAD/CIM equipment and cemented into the prepared cavity. Three dimensional model was made by the serial photographic method. The cavity width was varied $\frac{1}{3}$, $\frac{1}{2}$ and $\frac{2}{3}$ of intercuspal distance between buccal and lingual cusp tip. The cavity depth was varied 1.5mm and 2.3mm. So six models were constructed to simulate six conditions. A point load of 500N was applied vertically onto the first node of the lingual slope from the buccal cusp tip. The stress distribution and displacement were solved using ANSYS finite element program(Swanson Analysis System). (omitted)

  • PDF

수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교 (A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems)

  • 김성준;조광헌;이규복
    • 대한치과보철학회지
    • /
    • 제47권2호
    • /
    • pp.148-155
    • /
    • 2009
  • 연구목적: 최근에는 금속도재관의 심미적 문제로 심미성과 강도가 개선된 코아용 도재 및 지르코니아를 이용한 전부도재관 시스템에 관심이 증가되고 있다. 특히 금속과 유사한 강도를 가지면서 금속의 비심미성을 극복할 수 있는 지르코니아를 이용한 보철물의 제작이 국내외에서 많이 이뤄지고 있다. 하지만 CAD/CAM 시스템으로 제작되는 여러 종류의 지르코니아를 이용한 전부도재관의 적합도에 대한 임상 연구는 부족한 실정이다. 다양한 CAD/CAM 시스템 중 Procera, Cerec inLab, Lava에 의해 제작된 지르코니아를 이용한 전부도재관의 변연 적합도와 내면 적합도를 측정하여 이를 전통적인 방식으로 주조된 금속 도재관의 적합도와 비교 평가해 봄으로써 임상 적용에 참고 자료로 활용하고자 한다. 연구 재료 및 방법: 본 연구를 위해 하악 우측 제2소구치에 해당하는 레진치를 삭제하여 인상채득 후, 금속 주모형을 제작하였다. 금속 주모형의 40개의 인상을 채득 후 각 시스템마다 10개씩 총 40개의 crown을 제작하였다. 금속도재관은 전통적인 방식으로 제작하였고 Procera, Lava, Cerec inLab crown은 zirconia core를 이용하여 CAD/CAM 시스템으로 제작하였다. 수직 변연 오차와 내면 간격을 각 그룹마다 금속 주모형에 시멘트 접착 없이 측정하였다. 그 결과는 oneway ANOVA와 Tukey's HSD test로 통계 내었다. 결과: 수직 변연 오차는 금속도재관이 $50.6{\pm}13.9{\mu}m$, Procera crown이 $62.3{\pm}15.7{\mu}m$, Lava crown이 $45.3{\pm}7.9{\mu}m$, Cerec inLab crown은 $71.2{\pm}2.0{\mu}m$로 측정되었다. 내면 간격은 금속도재관이 $52.6{\pm}10.1{\mu}m$, Procera crown이$161.7{\pm}18.5{\mu}m$, Lava crown이 $63.0{\pm}10.2{\mu}m$, Cerec inLab crown이 $73.7{\pm}10.7{\mu}m$로 측정되었다. 변연 적합도 측면에서 볼 때 Procera crown, Lava crown, Cerec inLab 그리고 전통적인 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($120{\mu}m$) 내에 있었다. 내면 적합도 측면에서 볼 때 Procera crown을 제외한 Lava crown, Cerec inLab, 금속도재관은 임상적으로 받아들일 수 있는 적합도 범위($140{\mu}m$) 내에 있었다.

착색지르코니아 코어와 전장 도재 사이의 전단결합강도에 관한 연구 (A study on the shear bond strengths of veneering ceramics to the colored zirconia core)

  • 강선녀;조욱;전영찬;정창모;윤미정
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.312-319
    • /
    • 2009
  • 연구목적: 지르코니아-도재 수복물에 있어 상부도재와 코어 사이의 결합 실패가 종종 보고되어 왔으며 특히 착색지르코니아 코어는 기존의 백색 지르코니아보다 상부 도재와의 결합력이 약하다고 보고된 바 있다. 이 연구의 목적은 착색 지르코니아 코어 위의 상부도재를 적층식과 열가압식으로 제작하여 그 전단결합강도를 알아보고, 이를 전통적인 금속-도재간 결합강도와 비교하여 그 임상적 안정성을 평가하는 것이다. 연구 재료 및 방법: 금속도재군 (MC)을 대조군으로 하였다. 전통적인 금속도재군 (MC)과 지르코니아 코어를 사용한 두가지 군 (ZB, ZP)에 대하여 각 시스템별로 10개씩, 총 30개의 시편을 제작했다. CAD/CAM을 이용해 직경 12 mm, 높이 2.8 mm의 원판형 지르코니아 코어 (Katana zirconia)를 제작하고, 그 상부에 직경 2.8 mm, 높이 3 mm의 도재를 축성했다. ZB군은 CZR을 이용하여 적층법으로 상부도재를 제작했으며 ZP군은 NobelRondo Press ingot를 열가압하여 제작했다. Shear bond test machine (R&B Inc. Daejeon, Korea)을 이용하여 분당 0.50 mm의 속도로 파절이 일어날 때까지 전단력을 가하여 최대적용력 (N)을 측정하여 전단결합강도를 계산하고, 일원배치 분산분석을 사용하여 유의수준 5%에서 검정하였다. 파절양상을 알아보기 위하여 전자주사현미경을 통해 파절단면을 관찰했다. 결과: 평균 전단강도 (SD)는 MC 대조군 29.14 (2.26); ZB 29.48 (2.30); ZP 29.51 (2.32) 이었다. 실험군과 대조군 사이에 유의한 차이는 없었다. 모든 실험군에서 접착성 실패와 응집성 실패가 혼재된 양상을 보였으며, 응집성 실패가 우세했다. 결론: 1. 착색지르코니아 코어와 상부도재들 간의 전단결합강도는 금속 도재간 전단결합강도와 유의한 차이가 없었다. 2. 착색지르코니아 코어의 상부도재를 제작하는 방식에 있어 적층법과 열가압법 간의 전단결합강도에 유의한 차이는 없었다 (P > .05). 3. 파절양상은 응집성 파절이 우세한 가운데 접착성 파절과 응집성 파절이 혼재되어 나타났다.