• 제목/요약/키워드: Metal baffle

검색결과 16건 처리시간 0.029초

평판 예혼합 세라믹 버너의 분포판 변화에 따른 연소화염특성과 안정성 분석 (Combustion Characteristic and Stability of Flat Premixed Ceramic Burner with Different Porous Baffle Plates)

  • 이재영;이필형;박창수;박봉일;황상순
    • 한국연소학회지
    • /
    • 제14권4호
    • /
    • pp.7-16
    • /
    • 2009
  • Porous metal plates (Metal fiber, muti-hole metal plate) using mainly in surface burner are known to have a corrosion and durability problem under high temperature condition. In this study, premixed flat flame with perforated ceramic tile of more durable cordierite material was examined with respect to combustion stability and emission. The flat premixed ceramic burner consists of perforated ceramic tile and various type of baffle plates to form stable surface flame. The results show that most stable flat flame is generated using baffle plate with open ratio of 0.193. In downward flat flame mode which is widely used in condensing boiler, CO is measured below 50ppm from equivalence ratio 0.755 to 0.765 and $NO_X$ is measured below 12ppm from equivalence ratio 0.75 to 0.79. It is also found that the range of blue flame in flame stability curve becomes wider with increasing heat capacity.

  • PDF

흡음재가 초음속 제트의 소음특성에 미치는 영향 (Effect of Sound-Absorbing Materials on the Characteristics of Supersonic Jet Noise)

  • 곽종호;권용훈;청목준지;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1499-1504
    • /
    • 2004
  • The effects of absorbing materials on the characteristics of supersonic jet noise were experimentally investigated using a convergent-divergent nozzle with a design Mach number of 2.0. Overall sound pressure levels (OASPL) and noise spectra were obtained at far-field locations. Schlieren optical system was used to visualize the flow-fields of supersonic jets. In order to investigate the effect of absorbing materials, baffle plates of different materials (metal, grass wool and polyurethane foam) were installed at the exit of the nozzle. Experiment was carried out over a wide range of nozzle pressure ratios from 2.0 and 18.0, which corresponds to over- and under-expanded conditions. The results obtained show that the screech tone amplitude and the overall sound pressure level reduce by using the baffle plates of absorbing materials, compared with the metal baffle plate. It is also found that the characteristics of supersonic jet noise are strongly dependent on the size of baffle plate.

  • PDF

저압 급수가열기 추기노즐 주변 동체의 감육 완화에 관한 연구 (A Study on the Relief of Shell Wall Thinning around the Extraction Nozzle of Low Pressure Feedwater Heater)

  • 서혁기;박상훈;김형준;김경훈;황경모
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2631-2636
    • /
    • 2008
  • The most components and piping of the secondary side of domestic nuclear power plants were manufactured carbon-steel and low-alloy steel. Flow accelerated corrosion leads to wall thinning (metal loss) of carbon steel components and piping exposed to the flowing water or wet steam of high temperature, pressure, and velocity. The feedwater heaters of many nuclear power plants have recently experienced sever wall thinning damage, which increases as operating time progress. Several nuclear power plants in Korea have also experienced wall thinning damage in the shell wall around the impingement baffle. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the experimental results based on down-scaled experimental facility. The experiments were performed based on several types of impingement baffle plates which are installed in low pressure feedwater heater.

  • PDF

Metal Fiber와 Throttle Body를 적용한 가정용 응축보일러용 예혼합 버너의 연소특성 (Combustion Characteristics of Premixed Burner for Domestic Condensing Gas Boiler Using Metal Fiber and Throttle Body)

  • 이필형;황상순
    • 대한기계학회논문집B
    • /
    • 제41권4호
    • /
    • pp.249-256
    • /
    • 2017
  • 예혼합연소의 경우 연소시스템의 크기가 작고, 낮은 CO 및 NOx 배출 등의 많은 장점을 가지고 있어 고효율 저공해 가정용 응축보일러에 많이 적용되고 있다. 본 연구에서는 Metal Fiber와 Throttle Body를 적용하여 예혼합 연소시스템을 구성하여 연소특성을 분석하였다. 실험결과 Metal Fiber, Throttle Body 및 Baffle Plate의 조합을 통하여 열용량 6,250-25,000 kcal/h 조건에서 매우 안정적인 청염을 형성하였다. 배기가스의 경우 질소산화물은 당량비 0.724에서 0.795 조건에서 11 ppm 이하로 배출되었고 일산화탄소의 경우 동일 당량비 조건에서 50 ppm 이하로 배출되었다. 가정용 응축보일러의 중요 지표인 열효율의 경우 당량비 0.750 조건에서 96.3% 이상으로 측정되어 고효율 저공해 예혼합 연소시스템의 가능성을 확인하였다.

니켈합금 Metal Foam을 적용한 예혼합 버너의 연소특성 (Combustion Characteristics of Premixed Combustor using Nickel Based Metal Foam)

  • 이필형;황상순;김종광
    • 한국연소학회지
    • /
    • 제22권2호
    • /
    • pp.42-49
    • /
    • 2017
  • A premixed combustion has many advantages including low NOx and CO emission, high thermal efficiency and a small volume of combustor. This study focused on combustion characteristics in a premixed combustion burner using the nickel based metal foam. The results show that the blue flame is found to be very stable at heating load 6,300-25,200 kcal/h by implementing the proper nickel based metal foam and baffle plate. The premixed flame mode is changed into green flame, red flame, blue flame and lift off flame with decreasing equivalence ratio. NOx emission was measured 80 ppm(0% oxygen base) from 0.710 to 0.810 of equivalence ratio and CO emission is 90 ppm(0% oxygen base) under the same equivalence ratio. It is also found that the stable blue flame region in flame stability curve becomes wider with increasing the heat load.

해양 배경 소음 하의 수신 특성 안정화를 위한 원통형 하이드로폰 배열의 개념 설계 (Conceptual Design of Cylindrical Hydrophone Arrays for Stabilization of Receiving Characteristics under Ocean Ambient Noise)

  • 노응휘;이훈기;엄원석;장우석
    • 한국음향학회지
    • /
    • 제34권3호
    • /
    • pp.200-209
    • /
    • 2015
  • 수중 음향 감시 체계는 하이드로폰 배열을 이용하여 적함을 실시간으로 탐지하고 그 위치를 추적하는데, 해저 고정형 센서 배열은 이러한 감시 체계에 있어 중추적 역할을 수행한다. 본 연구에서는 천해 환경을 고려한 해저 고정형 원통형 하이드로폰 배열의 개념 설계를 유한요소해석을 통하여 수행하였다. 해양 배경 소음 하에서의 수신 특성 안정화를 위하여 금속 차단막을 이용한 배경 소음 스펙트럼 준위의 백색화 기법을 제안하였고, 배열 형상 최적화를 통하여 고각 및 방위각 방향의 지향성을 확보하였다. 나아가 소나돔의 형상과 재질에 따른 구조 진동 및 음향 산란 특성을 고찰하였다. 배경 소음 준위의 백색화, 배열 형상 최적화 및 소나돔의 음향적 투명화를 통하여, 해당 주파수 범위에 걸쳐 4 dB 이내의 감도 편차를 갖는 강건한 수신 특성의 하이드로폰 배열을 도출할 수 있음을 보였다.

Progressive Inelastic Deformation Characteristics of Cylindrical Structure with Plate-to-Shell Junction Under Moving Temperature Front

  • Lee, Hyeong-Yeon;Kim, Jong-Bum
    • Journal of Mechanical Science and Technology
    • /
    • 제17권3호
    • /
    • pp.400-408
    • /
    • 2003
  • A study on the progressive inelastic deformation behavior of the 316 L stainless steel cylindrical structure with plate-to-shell junction under moving temperature front was carried out by structural test and analysis. The structural test intends to simulate the thermal ratcheting behavior occurring at the reactor baffle of the liquid metal reactor as free surface of hot sodium pool moves up and down under plant transients. The thermal ratchet load that heats the specimen up to 550$^{\circ}C$ was applied repeatedly and residual deformation was measured. The thermal ratcheting test was carried out with two types of cylindrical structures, one with plate to-shell junction and the other without the junction to investigate the effects of the geometric discontinuities on the global ratcheting deformation. The temperature distributions of the test specimens were measured and were used for the ratcheting analysis. The ratchet deformations were analyzed with the constitutive equation of the non-linear combined hardening model. The analysis results were in good agreement with those of the structural tests.

Elevated Temperature Design of KALIMER Reactor Internals Accounting for Creep and Stress-Rupture Effects

  • Koo, Gyeong-Hoi;Bong Yoo
    • Nuclear Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.566-594
    • /
    • 2000
  • In most LMFBR(Liquid Metal Fast Breed Reactor) design, the operating temperature is very high and the time-dependent creep and stress-rupture effects become so important in reactor structural design. Therefore, unlike with conventional PWR, the normal operating conditions can be basically dominant design loading because the hold time at elevated temperature condition is so long and enough to result in severe total creep ratcheting strains during total service lifetime. In this paper, elevated temperature design of the conceptually designed baffle annulus regions of KALIMER(Korea Advanced Liquid MEtal Reactor) reactor internal strictures is carried out for normal operating conditions which have the operating temperature 53$0^{\circ}C$ and the total service lifetime of 30 years. For the elevated temperature design of reactor internal structures, the ASME Code Case N-201-4 is used. Using this code, the time-dependent stress limits, the accumulated total inelastic strain during service lifetime, and the creep-fatigue damages are evaluated with the calculation results by the elastic analysis under conservative assumptions. The application procedures of elevated temperature design of the reactor internal structures using ASME Code Case N-201-4 with the elastic analysis method are described step by step in detail. This paper will be useful guide for actual application of elevated temperature design of various reactor types accounting for creep and stress-rupture effects.

  • PDF

다공판 연소가스 유량제어를 통한 석탄화력발전소 보일러 성능 개선 (Improvement of Boiler Performance on 550 MW Coal Fired Thermal Power Plant via Baffle Plates)

  • 김치호;문승재
    • 플랜트 저널
    • /
    • 제17권1호
    • /
    • pp.38-49
    • /
    • 2021
  • 발전소 효율증대로 인해 610℃까지 높아진 증기온도는 보일러 튜브의 내구성을 저하시키고 있으며 여기에 저열량탄 사용증가로 후부연소 및 지연연소 현상이 가중됨에 따라 최종재열기의 과열과 튜브 파열사고가 빈번해지고 있다. 최종 재열기 과열을 방지하고자 과열저감수 주입량이 늘어났으며 이는 보일러 효율저하로 이어지고 있다. 그동안 보일러 튜브온도를 전체가 아닌 튜브 개별적으로 제어하기 위한 노력이 계속되어 왔지만 성공사례가 알려진 바가 없다. 이번 연구에서는 과열된 일부 튜브그룹에 다공판을 설치하여 가스흐름에 저항을 줌으로써 연소가스량을 저감시켜 튜브의 온도를 낮추고 저감된 연소가스는 인접한 곳으로 이동하여 다른 튜브의 온도를 높이는 것이다. 연구결과 튜브간 온도편차가 1.5℃ 감소하였고 과열저감수 주입량이 6,929 kg/h 감소하였으며 튜브 최고온도를 623.4℃까지 경감하였다. 이는 관리기준온도인 630℃에 6.6℃ 여유가 있는 수치이다.

유출수 및 유실토량 측정장치에 관한 수리시험 (Hydraulic Experiments on the Measuring Equipments of Ronoff and Soil Loss)

  • 유한열
    • 한국농공학회지
    • /
    • 제10권1호
    • /
    • pp.1377-1387
    • /
    • 1968
  • In order to measure runoff and soil losses produced in a small test plot during rainfall, it is usually insufficient to use a tank only, necessitating the combined use of a main tank and a subsidiary tank. Accordingly. exact measurement largely depends on how to connect those two measuring tanks. The main purpose of this thesis is to improve the connecting parts of two measuring tanks so as to assure exact measurement of runoff and soil losses. In this experiment, two types of main tank, i. e. A-type and B-type, were used. A-type is a square tank having a flume at its end. At the flume, ten apertures are provided by using metal columns so as to be able to catch one tenth of total muddy flow discharging at the end of the flume, One tenth of total flow is led to the subsidiary tank through a slot sampler fixed to an aperture. B-type differes in that its flume does not have apertures and slot sampler is fixed directly to the end of the flume, other features being the same as those of A-type. Discharge volumes were measured by using weighing tanks and compared. The effect of baffle screen provided in the flume was also observed in connection with exact measurements. In order to keep main tank and its flume in a horizontal position, bolts and nuts mechanism was used. Vertical and horizontal screens were provided in the main to prevent coarse sands coming into the flume. The conclusion derived through this experiment is as follows: (1) The discharge through slot sampler at each aperture is almost the same for A-type. However, it is slightly more than one tenth of total discharge volume. (2) In case that baffle screen is provided in the flume of A-type tank, the discharge volume of slot sampler is less than that of the same type without screen. (3) For B-type tank, slot sampler discharge increases as slot sampler nears toward the center of flume. (4) When baffle screen is provided in the flume of B-type, slot sampler discharge is less than that of the same type without screen, and this phenomenon is more apparent as compared with A-type. (5) In case that the slot width of slot sampler for B-type is one inch, slot sampler discharge exceeds one tenth of total discharge volume. (6) When the slot width for B-type is 15/16 inch and slot sampler is fixed 3/8 inch apart from either flume wall, slot sampler discharge is approximately equal to one tenth of total discharge volume.

  • PDF