• Title/Summary/Keyword: Metal Sealing

Search Result 75, Processing Time 0.024 seconds

Fabrication of Small SOFC Stack Based on Anode-Supported Unit Cells and Its Power Generating Characteristics (음극지지형 단전지를 사용한 소형 SOFC 스택의 제조 및 출력특성)

  • Jung, Hwa-Young;Kim, Woo-Sik;Choi, Sun-Hee;Kim, Joosun;Lee, Hae-Weon;Ko, Haengjin;Lee, Ki-Chun;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.777-782
    • /
    • 2004
  • In this research, $5\times5cm^2$ unit cells were fabricated via liquid condensation process and uniaxial pressing followed by the screen printing of electrolyte and cathode layer. The SOFC stack was assembled with unit cells, gasket-type sealant and metal interconnect. The stack was designed to have a single column with internal-manifold and cross-flow type gas-channels. The SOFC stack produced 15 W, which is $50\%$ of the maximum power being expected from the maximum power density of the unit cell. Controlling factors for the proper operation of the SOFC stack and other designing factors of stack manifold and gas channels were discussed.

BUBBLE BEHAVIOR OF PIT AND FISSURE SEALANT (치면열구전색제의 도포 시 전색제에 따른 기포 발생 양태)

  • Kim, Hyun-Jin;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.99-105
    • /
    • 2007
  • In clinical practice, air bubbles trapped in the pit and fissure may increase early loss of sealing materials for fracture, wear and microleakage. The purpose of this investigation was to examine the bubble behavior of pit and fissure sealant. The 140 replicas made of epoxy resin were used to this experiment. Following conditioning, light-polymerized sealants were applied and then exposed to the light source. After stereoscopic examination of standarized specimen by grinding, bubble behavior was analysed. The results obtained were as follows; 1. Ultraseal $XT^{(R)}$ plus grops irrespective of using time were higher than groups of $Helioseal^{(R)}$ with clinpro tip and metal tip in the frequency of bubble(p<0.05), 2. Ultraseal $XT^{(R)}$ plus old group was more than $Clinpro^{(R)}$, Teethmate $F-l^{(R)}$ and $Helioseal^{(R)}$ with brush tip in the number of bubble under 200 magnified cross section(p<0.05). 3. The widest mean area of bubble was shown in the Teethmate $F-1^{(R)}$. 4. No statistically significant difference of the frequency and the site of bubble between $Clinpro^{(R)}$ and $Helioseal^{(R)}$ groups(p>0.05).

  • PDF

Exophytic bone formation using porous titanium membrane combined with pins in rabbit calvarium. (핀 고정 천공형 티타늄막을 이용한 수직적 체조제증대술에 관한 연구)

  • Kim, Young;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.273-288
    • /
    • 2006
  • The purpose of this study was to evaluate exophytically vertical bone formation in rabbit calvaria by the concept of guided bone regeneration with a custom-made porous titanium membrane combined with bone graft materials. For this purpose, a total of 12 rabbits were used, and decorticated calvaria were created with round carbide bur to promote bleeding and blood clot formation in the wound area. Porous titanium membranes (0.5 mm in pore diameter, 10 mm in one side, 2 mm in inner height) were placed on the decorticated calvaria, fixed with metal pins and covered with full-thickness flap. Experimental group I was treated as titanium membrane only. Experimental group II, III, IV was treated as titanium membrane with BBM, titanium membrane with DFDB and titanium membrane with FDB. The animals were sacrificed at 8 and 12 weeks after surgery, and new bone formation was assessed by histomorphometric as well as statistical analysis. 1. Porous titanium membrane was biocompatable and capable of maintaining the regeneration space. 2. At 8 and 12 weeks, all groups demonstrated exophytic bone formation and there was a statistical significant difference among different groups only at 12 weeks. 3. The DFDB group revealed the most new bone formation compared to other groups (p<0.05). 4. At 12 weeks, DFDB and FDB groups showed the most significant resorption of graft materials (p<0.05). 5. The BBM was not resorbed at all until 12 weeks. 6. The fixation metal pin revealed excellent effect in peripheral sealing. On the basis of these findings, we conclude that a porous titanium membrane may be used as an augmentation membrane for guided bone regeneration, and DFDB as an effective bone forming graft material. The fixation of the membrane with pin will be helpful in GBR technique. However, further study is required to examine their efficacy in the intraoral experiments.

Experimental Evaluation of Weathering Performance for Duplex Coating Systems Combining Thermal Spraying Metals and Painting (금속용사와 도장의 복합피복방식법에 대한 실험적 내후성능평가)

  • Kim, In Tae;Jun, Je Hyong;Cha, Ki Hyuk;Jeong, Young Soo;Ahn, Jin Hee
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.5
    • /
    • pp.373-382
    • /
    • 2016
  • Painting or thermally sprayed metal coating is often used in corrosion protection of steel structures. In recently, duplex coating system which combines thermally sprayed metals with paint is selected as a new generic type of coatings on steel structures under the highly corrosive environments. In this study, the structural steel specimens were surface treated, thermally sprayed with zinc, zinc-15%aluminum alloy, aluminum and aluminum-5%magnesium alloy, and finally sealing or painted with acrylic urethane. And as a reference specimens, steel specimens were painted with acrylic urethane after surface treatment. Circular defects with 1.0, 3.0 and 5.0 mm in diameters and line defect with 2.0 mm width, which reach the steel substrate were created on all specimens. The specimens were exposed into an environmental testing chamber controlled by the ISO 20340, which is a laboratory cyclic accelerated exposure test condition of spraying/UV/low temperature, for up to 175 days. Based on the corrosion tests, corrosion deterioration from the initial defects were evaluated and weathering performance of the specimens are compared.

Study on the Urethane Restoration Filling Material and Adhesive for Stone Cultural Heritage (석조문화재 복원용 우레탄 메움제 및 접착제에 관한 연구)

  • Han, Won-Sik;Lee, Ho-Youn;Park, Gi-Jung;Hong, Tae-Kee;Wi, Koang-Chul
    • Journal of Conservation Science
    • /
    • v.27 no.1
    • /
    • pp.115-121
    • /
    • 2011
  • A Urethane resin restoration material was made to be used in the restoration of stone cultural assets. The Urethane resin restoration material showed strong adhesive strength and tensile strength similar to epoxy recovery material, which had been mainly used for the recovery of stone cultural assets. The sealing property, anti-shrinking property and paint-ability of Urethane resin restoration material are also similar to existing epoxy system restoration materials. Especially, this Urethane resin restration material is expected to give permanence and continuous stability in the restoration of cultural assets made in stone by resolving the two big issues of existing epoxy recovery material, which are 'yellowing' and 'ir-reversibility'. This Urethane resin restration material had been directly applied as a filling material and adhesive and it was dissolved again. The Urethane resin, which had been used for the recovery, was able to be perfectly removed, which means that this Urethane resin recovery material has perfect reversibility. This Urethane resin restoration material also has enhanced convenience since user can adjust the working-life dependent on work environment. It is believed that this Urethane resin restoration material can also be used as a filling material or adhesive for other cultural assets made of ceramic or metal heritage, in addition to stone, since it has strong adhesive strength and tensile strength.