• Title/Summary/Keyword: Metal Level

Search Result 1,622, Processing Time 0.039 seconds

A Survey on the Changes in Industrial Noisy Environment and Rearing loss of Workers (산업장 소음환경과 근로자 청력손실에 변동에 관한 조사)

  • Lee, Yong-Hwan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.22 no.3 s.27
    • /
    • pp.337-354
    • /
    • 1989
  • In order to evaluate the noisy environment and hearing loss of workers served in noisy working environment, the author investigated 212 manufacturing industries located in Ulsan Industrial District that could be observed for 3 successive years from 1986 to 1988. The obtained results were as follows: 1. There was increased tendency in the number of workers served in noisy working environment and that of examined of hearing loss for three years. 2. In the noise level of working environment, the number of industries less than 89dB(A) was increased every year, while more than 90dB(A) was in decreasing tendency. 3. Mean hearing loss by frequency was the most prominent in 4,000Hz, the level of hearing loss was in increasing tendency yearly, and that of left eat was higher than right ear in almost all type of industry. 4. In 1986, the level of hearing loss by type of industry was highest in manufacture of electric and electronic, and followed by paper and plywood, and metal products in right ear: that was in the order of manufacture of electric and electronic, metal products and textile products in left ear. In 1987, that was in the order of manufacture of metal products, machinery and others in right ear, and metal products, machinery and food stuff in left ear in 1988, manufacture of others, food stuff and machinery in both ear. 5. In hearing loss by service duration, right ear of 5-9 years group was higher than that of less than 5 years in 1987, whereas in 1988, the longer in service duration, the higher in the level of hearing loss in both ear. 6. In 1986, 1987 and 1988, the prevalence rate of noise-induced hearing loss were showed increasing tendency as 0.4% ,0.8% and 1.5% , respectively, and manufacture of textile products was highest(1.0%) in 1986, machinery(1.2%) in 1987 and others(2.8%) in 1988. 7. The proportion of grade E in early loss index were 76.1% (1986), 78.2% (1987) and 80.5% (1988) in left ear, 75.9% (1986), 76.4% (1987) and 75.9% (1988) in right ear.

  • PDF

Containing Heavy Metal Contaminants Using Soil-Cement Column Barrier (심층혼합기둥체 차수벽을 이용한 중금속 오염물질의 이동 제어)

  • 정문경;천찬란;이주형;김강석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.821-826
    • /
    • 2003
  • Laboratory experiments were peformed to understand physical properties of soil-cement column under the influence of acidic flow including metal contaminants and its retaining capacity against metal migration. The contaminant used in this study was nitric acid with Cu and Cd. The Permeability of soil-cement column decreased when pH of the column began to drop below 12. Decreases in pH led to significant reduction of compressive strength of clayey soil-cement specimen, while relatively marginal reduction for sandy soil-cement specimen. The metal contaminants did not leachate from soil-cement column until pH of soil-cement dropped below 7∼8 for Cu and 9∼10 for Cd. Metal contaminants were precipitated and trapped inside the soil-cement column at pHs higher than those mentioned as verified with metal analysis and visual inspection. This indicated that soil-cement column not only performs well as a cut-off wall, but also helps alleviating the level of contamination of the surrounding environment.

  • PDF

Thermal Residual Stress Analysis of Fiber Reinforced Metal Laminate (섬유강화금속적층판(FRML)의 열응력 해석)

  • 김위대;양승희
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.61-64
    • /
    • 2002
  • Fiber reinforced metal laminate(FRML) consists of alternations layers of metal and fiber reinforced composite. The difference in the coefficients of thermal expansion between metal and composite layer produces remarkable amount of thermal residual stresses between layers. Generally, FRML shows a tensile stress in metal layers, a compressive stress in composite layers after curing. In this study, the thermal residual stresses of several types of FRML are investigated to get the best combination of metal and composite which can reduce the thermal residual stresses. The residual stress level is compared with the strength of each layers to explain the fracture mechanism of FRML.

  • PDF

- Esthetic Retreatment of Old Restorations with Cervical Discolorations - (구 보철물 치경부 변색의 심미 재수복)

  • Kim, Hak-Su;Kim, Uk-Jung;Jo, Mun-Sang;Lee, Jong-Yeop
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2002
  • As patients have concerned the esthetics of dental restorations, the porcelain fused to metal restorations have gain their popularity due to their strength and esthetic appearance for many years. However, metal collar in subgingival level of porcelain fused to metal restoration often causes black shadows. Inadequately positioned metal collar causes plaque depositions, gingival inflammations, black shadows, and discolorations of margin area. Those problems can be avoided by a clear finishing line, well-fabricated provisional restorations with precise margin and fine polishing, collarless porcelain fused to metal restoration, and all ceramic restoration. In this case report, collarless porcelain fused to metal restoration was used to treat cervical discoloration from old restorations.

  • PDF

Electrical Characteristics of Metal/n-InGaAs Schottky Contacts Formed at Low Temperature

  • 이홍주
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.5
    • /
    • pp.365-370
    • /
    • 2000
  • Schottky contacts on n-In$\_$0.53//Ga$\_$0.47//As have been made by metal deposition on substrates cooled to a temperature of 77K. The current-voltage and capacitance-voltage characteristics showed that the Schottky diodes formed at low temperature had a much improved barrier height compared to those formed at room temperature. The Schottky barrier height ø$\_$B/ was found to be increased from 0.2eV to 0.6eV with Ag metal. The saturation current density of the low temperature diode was about 4 orders smaller than for the room temperature diode. A current transport mechanism dominated by thermionic emission over the barrier for the low temperature diode was found from current-voltage-temperature measurement. Deep level transient spectroscopy studies exhibited a bulk electron trap at E$\_$c/-0.23eV. The low temperature process appears to reduce metal induced surface damage and may form an MIS (metal-insulator-semiconductor)-like structure at the interface.

  • PDF

Circuit-Level Reliability Simulation and Its Applications (회로 레벨의 신뢰성 시뮬레이션 및 그 응용)

  • 천병식;최창훈;김경호
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.1
    • /
    • pp.93-102
    • /
    • 1994
  • This paper, presents SECRET(SEC REliability Tool), which predicts reliability problems related to the hot-carrier and electromigration effects on the submicron MOSFETs and interconnections. To simulate DC and AC lifetime for hot-carrier damaged devices, we have developed an accurate substrate current model with the geometric sensitivity, which has been verified over the wide ranges of transistor geometries. A guideline can be provided to design hot-carrier resistant circuits by the analysis of HOREL(HOT-carrier RFsistant Logic) effect, and circuit degradation with respect to physical parameter degradation such as the threshold voltage and the mobility can also be expected. In SECRET, DC and AC MTTF values of metal lines are calculated based on lossy transmission line analysis, and parasitic resistances, inductances and capacitances of metal lines are accurately considered when they operate in the condition of high speed. Also, circuit-level reliability simulation can be applied to the determination of metal line width and-that of optimal capacitor size in substrate bias generation circuit. Experimental results obtained from the several real circuits show that SECERT is very useful to estimate and analyze reliability problems.

  • PDF

Studies on the Evaluation Method of Heavy Metal Contamination Degree in the Han River (한강 저질중의 중금속 오염도 평가 방법에 관한 연구)

  • 어수미;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.1
    • /
    • pp.47-57
    • /
    • 1992
  • This study was performed to evaluate contamination degree of heavy metals in sediments of Han River, compared with other nation's evaluation method. The results were as follows 1. The contamination Ratio calculation method by heavy metal concentration in differnt fraction size has a limitation to apply to all of the areas of Han river because of its characteristics of sediment. As a result, this method applied to only 4 areas of Pal Dang, Wang Sook Chon, Uk Chon, and Bul Kwang Chon, and Contmination Ratio of heavy metals in those areas were relatively low of below 3. So it's considered that those areas have less contaminated from anthropogenic contaminants. 2. The Contamination Ratio calculation method by heavy metal concentration in different areasthat of upper area to be background level-has a limitation also to apply to Han river. But it is considered that this method was relatively suitable to apply, so it should be prepared evaluation standand method for them. Contamination ratio from background level as Pal Dang area were most high in An Yang Chon. So it must be prepared purification and control measure at An Yang Chon.

  • PDF

Nano-level Device 제조를 위한 신 메탈 전극 세정에 관한 연구

  • 변재호;송용화;천희곤
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.64-67
    • /
    • 2003
  • 본 연구는 nano-level 디바이스 제조를 위한 새로운 금속 전극인 W 과 Ti metal 표면 세정에 관한 연구이다. 기존 $SC-1(NH_4OH/H_2O_2/H_2O)$ 세정 용액에서 산화제 ($H_2O_2$)를 사용하지 않는 dilute $NH_4$OH 세정은 전극 사이 절연막 표면의 particle 제거가 가능하면서 노출된 metal 막의 세정 damage를 최소화 시키는 것을 확인했다. SC-1 용액 내에 산화제 미 첨가 효과는, metal 막의 식각 현상을 억제시키고, 절연막 표면의 particle 제거 효과에 영향을 미치지 않는 것으로 판단된다. 이러한 방법은 short time 공정이 필요한 관계로, spin type wet 장비 채택으로 세정 효과의 극대화를 얻을 수 있을 것으로 판단된다.

  • PDF

The Correlation of Heavy Metal Contents in Herbal Medicines and Their Soils at North Gyeongbuk Area (경북북부지역 한약재와 재배토양중의 중금속과의 상관관계)

  • Park Moon-Ki;Lee Hyeun-Jeung;Kim Kwang-Joong;Moon Young-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.185-192
    • /
    • 2005
  • The concentration of heavy metal were studied for the estimation of quality in herbal medicines which is Bupleuri Radix, Paeoniae Radix, Dioscoreae Rhizoma and Astragali Radix in products of north Gyeongbuk area Also, we collected soils from several area in Gyeongbuk, and determined heavy metal concentration of soils by ICP. We compared with herbal medicines in products of Gyeongbuk and their soils. The average levels of heavy metal of herbal medicines in Gyeongbuk area are as follows: Mercury is 0.037mg/kg, Chromium is 0.093 mg/kg, Nickel is 0.108mg/kg, Copper is 0.475mg/kg, Zinc is 3.14mg/kg, Manganese is 1.52mg/kg, Iron is 7,83mg/kg, and Cadmium, Lead and Arsenic is not detected. It was very lower in concentrations than those of average Korea area. For the heavy metals contents of Gyeongbuk area, in Gong Jung Ri, represented the higher level, it may be due to a near the road. The Cd contents in soil was not a wide difference. For the As and Pb contents in soil, Song Sa Ri (Bupleuri Radix) represented the higher level(0.68mg/kg, 1523mg/kg). Correlation coefficients of heavy metal contents in cultured herbal medicines and their soils did not give reproducible results. But the degree of correlation between a few heavy metal contents of Dioscoreae Rhizoma and their soil showed the good transfer from the soil.

Abrasion Wear Behavior of Recycled Tungsten Carbide Reinforced Metal Matrix Composite (재생 초경합금 분말을 활용한 금속기지 복합재료의 Abrasion 마모거동)

  • Kang, Nam-Hyun;Chae, Hyun-Byung;Kim, Jun-Ki;Choi, Jong-Ha;Kim, Jeong-Han
    • Korean Journal of Materials Research
    • /
    • v.13 no.12
    • /
    • pp.850-854
    • /
    • 2003
  • The abrasion wear behavior on the hardfacing weld was investigated by performing abrasion wear, hardness, and microstructural tests. The gas metal arc(GMA) weld was produced by using the cored wire which was filled with the hard metal, i.e., the recycled tungsten carbide (WC) reinforced metal matrix composite. For 30% addition of the hard metal, the abrasion wear resistance was significantly improved comparing with that for 20% addition of the hard metal. Above 30% addition of the hard metal, however, there was no significant improvement of the wear resistance. The improvement of the wear resistance was due to the increased amount of eutectic carbides(W$_{6}$C) which was formed during GMA welding. For the weld in which the hard metal was added to 30-40%, an optimum level of abrasion wear resistance was performed.