• Title/Summary/Keyword: Metal Filter

Search Result 347, Processing Time 0.031 seconds

Design of a Wide-Frequency-Range, Low-Power Transceiver with Automatic Impedance-Matching Calibration for TV-White-Space Application

  • Lee, DongSoo;Lee, Juri;Park, Hyung-Gu;Choi, JinWook;Park, SangHyeon;Kim, InSeong;Pu, YoungGun;Kim, JaeYoung;Hwang, Keum Cheol;Yang, Youngoo;Seo, Munkyo;Lee, Kang-Yoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.126-142
    • /
    • 2016
  • This paper presents a wide-frequency-range, low-power transceiver with an automatic impedance-matching calibration for TV-white-space (TVWS) application. The wide-range automatic impedance matching calibration (AIMC) is proposed for the Drive Amplifier (DA) and LNA. The optimal $S_{22}$ and $S_{11}$ matching capacitances are selected in the DA and LNA, respectively. Also, the Single Pole Double Throw (SPDT) switch is integrated to share the antenna and matching network between the transmitter and receiver, thereby minimizing the systemic cost. An N-path filter is proposed to reject the large interferers in the TVWS frequency band. The current-driven mixer with a 25% duty LO generator is designed to achieve the high-gain and low-noise figures; also, the frequency synthesizer is designed to generate the wide-range LO signals, and it is used to implement the FSK modulation with a programmable loop bandwidth for multi-rate communication. The TVWS transceiver is implemented in $0.13{\mu}m$, 1-poly, 6-metal CMOS technology. The die area of the transceiver is $4mm{\times}3mm$. The power consumption levels of the transmitter and receiver are 64.35 mW and 39.8 mW, respectively, when the output-power level of the transmitter is +10 dBm at a supply voltage of 3.3 V. The phase noise of the PLL output at Band 2 is -128.3 dBc/Hz with a 1 MHz offset.

Analysis of Heavy Metal Element and Microorganism by Manufacture of Particulate Matter Sampler for Science Project of Secondary School (중등학교에서 사용 가능한 미세먼지 포집 장치 제작을 통한 대기 중 중금속 및 미생물 분석)

  • Kwon, Woo-Jin;Kim, Young-Jae;Byeon, Jung-Ho
    • Journal of the Korean earth science society
    • /
    • v.36 no.1
    • /
    • pp.125-135
    • /
    • 2015
  • The purpose of this study were to sample particulate matter and analyze its elements and microorganisms for secondary school science project. The particulate matter was sampled on the rooftop a four-store building at a university in Chungju province. A simplified capturing system was developed with the parts, motor-pump, innet, $1.0{\mu}m$ teflon filter, filter-holder, etc. Using the system, this study had sampled particulate matter during Dec., 2013-Jun., 2014. Then, this study analyzed the elements and microorganisms of the sampled particulate matter. Results have been shown that the particulate matter derived China urban area is mainly consisted of the artificial pollutant, such as Cu, Zn, Cd, Ni, Pb. In addition, this study has been shown that microorganisms, such as bacteria and fungi, are included in the particulate matter. Therefore, this study suggests a new systemic investigation and monitoring about the particulate matter, specially originated from China. Also, this study provides a sample for secondary school science experiment.

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis (근전의수용 소형 표면 근전위 센서의 개발)

  • Choi, Gi-Won;Sung, So-Young;Moon, Inhyuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.67-76
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for the myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket for the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is. composed of a skin interface and a single processing circuit that are mounted on a single package. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

Evanescent-mode Waveguide Band-pass Filter Applied by Novel Metal Post Capacitor (새로운 금속막대 커패시터를 적용한 감쇄모드 도파관 대역통과 여파기)

  • Kim, Byung-Mun;Yun, Li-Ho;Lee, Sang-Min;Hong, Jae-Pyo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.775-782
    • /
    • 2022
  • In this paper, a novel small-diameter cylindrical post capacitor inserted into an evanescent-mode rectangular waveguide (EMRWG) is proposed for easier tuning. In order to feed the EMRWG, the proposed structure uses a single ridge rectangular waveguide with the same width and height as the waveguide at the input and output ends. The inserted post capacitor are made up a circular groove formed in the center of the lower part of the broad wall of the EMRWG, and a concentric cylindrical post inserted into the upper part. First, the equivalent circuit model for the proposed structure is presented. When the EMRWG and the single ridge waveguide are combined, the joint susceptance and the turns ratio of the ideal transformer are calculated by two simulations using HFSS (3d fullwave simulator, Ansoft Co.) respectively. The susceptance and resonance characteristics of the inserted post were analyzed by using the obtained parameters and the characteristics of the EMRWG. A 2-post filter with a center frequency of 4.5 GHz and a bandwidth of 170 MHz was designed using a WR-90 waveguide, and the simulation results by using the HFSS and CST, equivalent circuit model were in good agreement.

A Study on the Concentration Distribution of Airborne Heavy Metals in Major Industrial Complexes in Korea (국내 주요 산업단지 대기 중 중금속농도 분포에 관한 연구)

  • Kang, Byung-Wook;Kim, Min-Ji;Baek, Kyung-Min;Seo, Young-Kyo;Lee, Hak Sung;Kim, Jong-Ho;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.2
    • /
    • pp.269-280
    • /
    • 2018
  • This paper reports the results of field evaluation to determine the levels of heavy metals in major industrial complexes in Korea over a seven year period (2007~2013). The measurement of heavy metal was conducted using quartz fiber filter sampling and ICP-AES analysis. In order to validate the analytical performance of these methods, studies were also carried out to investigate data quality control(QC) parameters, such as the method detection limit (MDL), repeatability, and recovery efficiencies. The average concentrations of total suspended particulates (TSP) for the nine industrial complexes in Korea were $104{\sim}169{\mu}g/m^3$, which was higher than other industrial complexes and urban areas. The Sihwa and Banwol industrial complexes were shown to be the biggest contributing sources to high TSP emission ($159{\mu}g/m^3$ and $169{\mu}g/m^3$, respectively). The concentrations of heavy metals in TSP were higher in the order of Fe>Cu>Zn, Pb, Mn>Cr, Ni, As and Cd. It was observed that Fe was the highest in the Gwangyang and Pohang steel industrial complexes. The concentrations of Zn and Pb were high in Onsan, Sihwa and Banwol industrial complexes, and this was attributed to the emission from the nonferrous industry. Additionally, Cr and Ni concentrations were high in the Sihwa and Banwol industrial complexes due to plating industry. On the other hand, Ulsan and Onsan industrial complexes showed high Cr and Ni concentrations as a response to the emission of metal industry related to automobile. The correlation analysis revealed the high correlation between Cr and Ni in plating industry from Sihwa and Banwol industrial complexes. Adding to this, components related to coal combustion and road dust showed high correlation in Pohang and Gwangyang industrial complexes. Then Onsan and Ulsan industrial complexes showed high correlation among components related to the nonferrous metals.

A $64\times64$ IRFPA CMOS Readout IC for Uncooled Thermal Imaging (비냉각 열상장비용 $64\times64$ IRFPA CMOS Readout IC)

  • 우회구;신경욱;송성해;박재우;윤동한;이상돈;윤태준;강대석;한석룡
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.5
    • /
    • pp.27-37
    • /
    • 1999
  • A CMOS ReadOut Integrated Circuit (ROlC) for InfraRed Focal Plane Array (IRFPA) detector is presented, which is a key component in uncooled thermal imaging systems. The ROIC reads out signals from $64\times64$ Barium Strontium Titanate (BST) infrared detector array, then outputs pixel signals sequentially after amplifying and noise filtering. Various design requirements and constraints have been considered including impedance matching, low noise, low power dissipation and small detector pitch. For impedance matching between detector and pre~amplifier, a new circuit based on MOS diode structure is devised, which can be easily implemented using standard CMOS process. Also, tunable low pass filter with single~pole is used to suppress high frequency noise. In additions, a clamping circuit is adopted to enhance the signal~to-noise ratio of the readout output signals. The $64\times64$ IRFPA ROIC is designed using $0.65-\mu\textrm{m}$ 2P3M (double poly, tripple metal) N~Well CMOS process. The core part of the chip contains 62,000 devices including transistors, capacitors and resistors on an area of about $6.3-mm\times6.7-mm$.

  • PDF

Multi-Channel Analog Front-End for Auditory Nerve Signal Detection (청각신경신호 검출 장치용 다중채널 아나로그 프론트엔드)

  • Cheon, Ji-Min;Lim, Seung-Hyun;Lee, Dong-Myung;Chang, Eun-Soo;Han, Gun-Hee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.1
    • /
    • pp.60-68
    • /
    • 2010
  • In case of sensorineural hearing loss, auditory perception can be activated by electrical stimulation of the nervous system via electrode implanted into the cochlea or auditory nerve. Since the tonotopic map of the human auditory nerve has not been definitively identified, the recording of auditory nerve signal with microelectrode is desirable for determining the tonotopic map. This paper proposes the multi-channel analog front-end for auditory nerve signal detection. A channel of the proposed analog front-end consists of an AC coupling circuit, a low-power 4th-order Gm-C LPF, and a single-slope ADC. The AC coupling circuit transfers only AC signal while it blocks DC signal level. Considering the bandwidth of the auditory signal, the Gm-C LPF is designed with OTAs adopting floating-gate technique. For the channel-parallel ADC structure, the single-slope ADC is used because it occupies the small silicon area. Experimental results shows that the AC coupling circuit and LPF have the bandwidth of 100 Hz - 6.95 kHz and the ADC has the effective resolution of 7.7 bits. The power consumption per a channel is $12\;{\mu}W$, the power supply is 3.0 V, and the core area is $2.6\;mm\;{\times}\;3.7\;mm$. The proposed analog front-end was fabricated in a 1-poly 4-metal $0.35-{\mu}m$ CMOS process.

Drainage and Treatment Characteristics of Runoff by Media (여재에 따른 도로면 유출수의 배수 및 처리특성)

  • Kim, Seog-gu;Yun, Sang-Ieen;Kim, Young-im;Lee, Yong-jae;Kim, Ree-ho;Kim, Jong-oh
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.500-505
    • /
    • 2004
  • While more attention has been paid in recent years to urban point source pollution control, no considerable measures have been taken to control urban non-point source pollution. Contaminants from non-point sources deposited on urban impermeable surfaces such as road and highway are easily released to the public waters by rainfall, leading to the deterioration in water quality in urban area. The present study investigated a system using filter media to reduce the level of contamination in urban road runoff. Three different media, designated as J-P (polypropylene, blowing type), B-P (polypropylene, fiber type), and P-F (Polyvinyl alcohol, cube and sheet type) were evaluated on the basis of pollutant removal efficiency as well as hydraulic property. Experiments were peformed using a 1/4-scale treatment unit at various pollutant roading and rainfall intensity with real rainwater runoff collected from road surfaces. The results at different rainfall intensities shows that the medium J-P is superior to the other media for water permeability. J-P was not blocked at 10 mm/hr rainfall and its permeability was stable. On the other hand, B-P and P-F resulted in substantial overflow ratio even at I mm/hr rainfall intensity. Comparing treatment efficiencies for suspended solids, all media showed similar removal ranged from 91 % to 95%. However, J-P seems to be better than the other media considering its higher water permeability. J-P and P-F, both hydrophobic, yielded over 76% of heavy metal removal. But, the hydrophilic media B-P showed much smaller removal ranging from 26% to 47%. This indicates that J-P and P-F are beneficial to remove heavy metal due to their hydrophobic property. The treatment efficiencies over PAHs (poly aromatic hydrocarbons) showed the similar removal efficiency ranging from 66% to 97% for all three media.

Active-RC Channel Selection Filter with 40MHz Bandwidth and Improved Linearity (개선된 선형성을 가지는 R-2R 기반 5-MS/s 10-비트 디지털-아날로그 변환기)

  • Jeong, Dong-Gil;Park, Sang-Min;Hwang, Yu-Jeong;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.1
    • /
    • pp.149-155
    • /
    • 2015
  • This paper proposes 5-MS/s 10-bit digital-to-analog converter(DAC) with the improved linearity. The proposed DAC consists of a 10-bit R-2R-based DAC, an output buffer using a differential voltage amplifier with rail-to-rail input range, and a band-gap reference circuit for the bias voltage. The linearity of the 10-bit R-2R DAC is improved as the resistor of 2R is implemented by including the turn-on resistance of an inverter for a switch. The output voltage range of the DAC is determined to be $2/3{\times}VDD$ from an rail-to-rail output voltage range of the R-2R DAC using a differential voltage amplifier in the output buffer. The proposed DAC is implemented using a 1-poly 8-metal 130nm CMOS process with 1.2-V supply. The measured dynamic performance of the implemented DAC are the ENOB of 9.4 bit, SNDR of 58 dB, and SFDR of 63 dBc. The measured DNL and INL are less than +/-0.35 LSB. The area and power consumption of DAC are $642.9{\times}366.6{\mu}m^2$ and 2.95 mW, respectively.

A Study on the Separation and Recovery of Useful Metallic Elements(Zn, Pb) from the 2nd Dust in Refining of Crude-Zinc Oxide (조산화아연의 정제과정에서 발생된 2차분진으로부터 유용금속원소(Zn, Pb)의 분리회수에 관한 연구)

  • Yoon, Jae-hong;Yoon, Chi-hyun
    • Resources Recycling
    • /
    • v.30 no.1
    • /
    • pp.66-76
    • /
    • 2021
  • Electric arc furnace dust (EAFD) contains compounds, such as oxides and chlorides, including large quantities of Zn, Pb and Fe. An efficient and stable method for the extraction of metal elements from EAFD is the Rotary Kiln Process. This method is used to recover Zn in the form of crude ZnO (approximately 60%) via the addition of a reducing agent (coke, anthracite) and limestone (for basicity control) to EAFD. This process is commonly used in industry as well as in research and development. Currently, this method is used in many Korean commercial plants, producing approximately 150,000 tons of Crude ZnO per year. The majority of Zn is found in crude ZnO (approximately 76%). In addition components such as Pb, Cd, Sn, In, Fe, Cl, and F are present as oxides, chlorides, and alkaline compounds. This elements have an adverse effect on the zinc smelting process. Therefore, a refining process that eliminates these impurities is essential. In this study, we developed a process technology that efficiently separates Zn and Pb from byproducts (mainly chlorides). A bag filter was used to collect Zn and Pb generated during the dry purification process of crude ZnO. Pure components were recovered as metals or metal carbonate.