• 제목/요약/키워드: Metal Cap

검색결과 74건 처리시간 0.021초

Ultrahigh supercapacitance in cobalt oxide nanorod film grown by oblique angle deposition technique

  • Kannan, V.;Choi, Jong-Hyeok;Park, Hyun-Chang;Kim, Hyun-Seok
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1399-1402
    • /
    • 2018
  • Nanorod films of cobalt oxide ($Co_3O_4$) have been grown by a unique oblique angle deposition (OAD) technique in an e-beam evaporator for supercapacitor electrode applications. This technique offers a non-chemical route to achieve large aspect ratio nanorods. The fabricated electrodes at OAD $80^{\circ}$ exhibited a specific capacitance of 2875 F/g. The electrochemically active surface area was $1397cm^{-2}$, estimated from the non-Faradaic capacitive current region. Peak energy and power densities obtained for $Co_3O_4$ nanorods were 57.7 Wh/Kg and 9.5 kW/kg, respectively. The $Co_3O_4$ nanorod electrode showed a good endurance of 2000 charge-discharge cycles with 62% retention. The OAD approach for fabricating supercapacitor nanostructured electrodes can be exploited for the fabrication of a broad range of metal oxide materials.

하악 유전치부 치조골 골절시 resin-wire open cap splint를 이용한 고정 (IMMOBILIZATION OF LOWER MANDIBULAR ALVEOLAR BONE FRACTURE USING RESIN-WIRE OPEN CAP SPLINT)

  • 권정현;최병재;최형준;김성오;손흥규;이제호
    • 대한소아치과학회지
    • /
    • 제35권1호
    • /
    • pp.175-180
    • /
    • 2008
  • 치아 및 치조골은 복합적인 구조이므로 치아의 함입이나 측방 탈구와 같은 치조와의 변위가 있는 다수 치아를 포함한 외상에서 치조골 골절이 동반될 수 있다. 치조골이 골절되면 치주인대 및 치수로의 혈행이 단절되어 치아의 합병증을 유발할 수 있고, 특히 유치열기 외상은 후속 영구치배에 손상을 줄 가능성이 있으므로 장기간의 관찰이 필요하다. 치아 및 치조골 골절의 치료 시에는 환자의 연령과 외상의 위치 및 범위, 유치의 변위 정도 및 방향을 고려해야하며, 골절편을 재위치 시키고 고정하기 위하여 아치바(arch bar), 레진-강선 고정, 교정용 밴드, 아크릴 또는 금속 캡 스플린트(acrylic or metal cap splint), 화이버 스플린트(fiber-splint) 등의 다양한 방법이 고안되었다. 본 증례는 외상으로 인하여 치조골이 골절되어 내원한 1세 11개월 된 환아로서 모형상에서 레진-강선 오픈 캡 스플린트(resin-wire open cap splint)를 제작하여 고정한 후 양호한 치료 결과를 얻었다. 이 방법은 부가적인 기공 과정이 필요하지만, 유치열기에서 사용할 수 있고, 시술시간이 짧아 비협조적인 환아에게 진정요법 없이 적용할 수 있으며, 일반적인 아크릴 캡 스플린트에 비해 부피가 작아 불편감이 적고, 교합을 방해하지 않으며, 접착시 시멘트가 빠져나갈 공간이 있어서 스플린트의 정확한 안착이 가능하다. 또한 비교적 통증이 적으며 침습적이지 않아 출혈이 없으므로 의과적문제가 있는 경우에도 사용할 수 있다.

  • PDF

분말사출성형을 이용한 다수 캐비티 치과용 요오드 용기 금형제작에 관한 연구 (A Study on mold manufacture of multi-cavity dental iodine container using powder injection molding)

  • 최재훈
    • 한국산학기술학회논문지
    • /
    • 제15권1호
    • /
    • pp.21-26
    • /
    • 2014
  • 치과에서 사용되는 구강 치료용 요오드 용기는 개폐 시 용기의 캡에 부착되어 있는 칼날에 의해 치료용 실은 절단이 된다. 금속의 칼날은 요오드 용액과 반응하여 단기간에 부식이 되는 문제로 인해 환자의 위생에도 영향을 준다. 이러한 문제를 해결하기 위해 최근 세라믹 칼날로 대체되어진 제품들도 개발되어 생산되는데, 이때 세라믹 칼날은 수작업과 기계가공을 통해 만들어 진다. 본 연구에서는 세라믹 칼날을 분말사출성형공정으로 대량 생산할 수 있도록 20Cavity의 균일 충전을 위한 유동 시스템을 제안하였다. Moldflow를 이용하여 20cavity 유동성에 대한 시뮬레이션을 진행하였고, 금형제작과 수정을 통해 금형을 완성하였다. 사출성형 후 탈지와 소결공정을 통해 완성하고, 금형에 세라믹 칼날을 인서트 사출하여 캡 제품을 완성하였다. 본 연구를 통해 유효한 절단 성능을 갖는 세라믹칼날 대량생산 가능성을 검증하였다.

식품병마개 PVC gasket과 식품에 함유된 semicarbazide의 분석 (Determination of Semicarbazide in PVC Gaskets of Food Bottle Cap and Foods)

  • 박상욱;이광호;곽인신;전대훈;이시경
    • 한국식품과학회지
    • /
    • 제37권3호
    • /
    • pp.334-338
    • /
    • 2005
  • 본 연구는 식품병마개 PVC 가스켓과 식품에 함유된 SEM을 효과적으로 분석하기 위해 연구했다. SEM은 발포제로 사용되는 ADC의 열분해산물로 알려졌다. 그러나 SEM은 분자량이 낮으며 ultraviolet light나 fluorescence에 활성을 갖지 않는다. 따라서 2-NBA-SEM으로 유도체화하여 HPLC triple column system으로 분석했을 때 상관관계는 0.9997이상이며 검출한계는 0.48ng/g으로 나타났다. 식품병마개 PVC 가스켓에서 SEM의 검출율은 77.08%로 나타났으며, 유통중인 병마개 PVC 가스켓에서 SEM은 812.20-5771.30ng/g 수준이였다. 그리고 회수율은 PVC 가스켓과 식품에서 각각 92.12-98.71%와 83.45-97.33%로 측정되었다.

In-situ SiN 패시베이션 층에 따른 AlGaN/GaN HEMTs의 전기적 및 저주파 잡음 특성 (Electrics and Noise Performances of AlGaN/GaN HEMTs with/without In-situ SiN Cap Layer)

  • 최여진;백승문;이유나;안성진
    • 접착 및 계면
    • /
    • 제24권2호
    • /
    • pp.60-63
    • /
    • 2023
  • AlGaN/GaN 이종접합 구조는 이차원 전자 가스층(2-DEG)으로 인해 높은 전자이동도를 갖고 있으며, 넓은 밴드갭을 갖기 때문에 고온에서 높은 항복전압을 갖는 특성을 가지고 있어, 고전력, 고주파 전자 소자로 주목받고 있다. 이러한 이점을 갖고 있음에도 불구하고, 전류 붕괴 등의 다양한 소자 신뢰성에 영향을 주는 인자들이 있기 때문에 이를 해결하고자, 본 논문에서는 금속-유기-화학기상증착법을 이용하여 AlGaN/GaN 이종 접합구조와 SiN 패시베이션 층을 연속 증착시켰다. 이를 통해 HEMTs소자에 SiN패시베이션이 미치는 재료 특성 및 전기적 특성을 분석했으며, 결과를 바탕으로 저주파 잡음 특성을 측정해 소자의 전도 메커니즘 모델과 채널 내의 결함의 원인에 대해서 분석하였다.

The application of DGTs for assessing the effectiveness of in situ management of Hg and heavy metal contaminated sediment

  • Bailon, Mark Xavier;Park, Minoh;Choi, Young-Gyun;Reible, Danny;Hong, Yongseok
    • Membrane and Water Treatment
    • /
    • 제11권1호
    • /
    • pp.11-23
    • /
    • 2020
  • The effectiveness of in situ sediment capping as a technique for heavy metal risk mitigation in Hyeongsan River estuary, South Korea was studied. Sites in the estuary were found previously to show moderate to high levels of contamination of mercury, methylmercury and other heavy metals. A 400 m × 50 m section of the river was selected for a thin layer capping demonstration, where the total area was divided into 4 sections capped with different combinations of capping materials (zeolite, AC/zeolite, AC/sand, zeolite/sand). Pore water concentrations in the different sites were studied using diffusive gradient in thin film (DGT) probes. All capping amendments showed reduction in the pore water concentration of the different heavy metals with top 5 cm showing %reduction greater than 90% for some heavy metals. The relative maxima for the different metals were found to be translated to lower depths with addition of the caps. For two-layered cap with AC, order of placement should be considered since AC can easily be displaced due to its relatively low density. Investigation of methylmercury (MeHg) in the site showed that MeHg and %MeHg in pore water corresponds well with maxima for sulfide, Fe and Mn suggesting mercury methylation as probably coupled with sulfate, Fe and Mn reduction in sediments. Our results showed that thin-layer capping of active sorbents AC and zeolite, in combination with passive sand caps, are potential remediation strategy for sediments contaminated with heavy metals.

Mechanistic investigations on emission characteristics from g-C3N4, gC3N4@Pt and g-C3N4@Ag nanostructures using X-ray absorption spectroscopy

  • Sharma, Aditya;Varshney, Mayora;Chae, Keun Hwa;Won, Sung Ok
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1458-1464
    • /
    • 2018
  • An improved method for the preparation of g-$C_3N_4$ is described. Currently, heating (> $400^{\circ}C$) of urea is the common method used for preparing the g-$C_3N_4$. We have found that sonication of melamine in $HNO_3$ solution, followed by washing with anhydrous ethanol, not only reduce the crystallite size of g-$C_3N_4$ but also facilitate intriguing electronic structure and photoluminescence (PL) properties. Moreover, loading of metal (Pt and Ag) nanoparticles, by applying the borohydride reduction method, has resulted in multicolor-emission from g-$C_3N_4$. With the help of PL spectra and local electronic structure study, at C K-edge, N K-edge, Pt L-edge and Ag K-edge by X-ray absorption spectroscopy (XAS), a precise mechanism of tunable luminescence is established. The PL mechanism ascribes the amendments in the transitions, via defect and/or metal states assimilation, between the ${\pi}^*$ states of tris-triazine ring of g-$C_3N_4$ and lone pair states of nitride. It is evidenced that interaction between the C/N 2p and metal 4d/5d orbitals of Ag/Pt has manifested a net detraction in the ${\delta}^*{\rightarrow}LP$ transitions and enhancement in the ${\pi}^*{\rightarrow}LP$ and ${\pi}^*{\rightarrow}{\pi}$ transitions, leading to broad PL spectra from g-$C_3N_4$ organic semiconductor compound.

Prosthetic resurfacing of engaging posterior capitellar defects in recurrent posterolateral rotatory instability of the elbow

  • Dani Rotman;Jorge Rojas Lievano;Shawn W. O'Driscoll
    • Clinics in Shoulder and Elbow
    • /
    • 제26권3호
    • /
    • pp.287-295
    • /
    • 2023
  • Background: Posterolateral rotatory instability (PLRI) is a common mechanism of recurrent elbow instability. While the essential lesion is a deficiency in the lateral ulnar collateral ligament (LUCL), there are often associated concomitant bony lesions, such as an Osborne-Cotterill lesions (posterior capitellar fractures) and marginal radial head fractures, that compromise stability. Currently, there is no standard treatment for posterior capitellar deficiency associated with recurrent PLRI. Methods: We conducted a retrospective review of five patients with recurrent PLRI of the elbow associated with a posterior capitellar impaction fracture engaging with the radial head during normal range of motion. The patients were treated surgically with LUCL reconstruction or repair and off-label reconstruction of the capitellar joint surface using a small metal prosthesis designed for metatarsal head resurfacing (HemiCAP toe classic). Results: Five patients (three adolescent males, two adult females) were treated between 2007 and 2018. At a median follow-up of 5 years, all patients had complete relief of their symptomatic instability. No patients had pain at rest, but two patients had mild pain (visual analog scale 1-3) during physical activity. Three patients rated their elbow as normal, one as almost normal, and one as greatly improved. On short-term radiographic follow-up there were no signs of implant loosening. None of the patients needed reoperation. Conclusions: Recurrent PLRI of the elbow associated with an engaging posterior capitellar lesion can be treated successfully by LUCL reconstruction and repair and filling of the capitellar defect with a metal prosthesis. This treatment option has excellent clinical results in the short-medium term. Level of evidence: IV.

A study on the Assyrian Costume

  • Kim, Moon-Ja
    • 패션비즈니스
    • /
    • 제14권3호
    • /
    • pp.1-19
    • /
    • 2010
  • The Assyrians usually wore two types - the tunic and the shawl. These two types were worn alone, or in combination and changes were introduced by varying the proportions of the tunic or shawl. The tunic appeared to be of the sleeves are short and reaching to the ankles or shortened to knee length according to the rank. Assyrian shawl pattern can be divided into five distinct styless. Many of the styles were suitable for costumes to wear in religious plays and pageants. Fringed shawls were the trademark of forma1 Assyrian costume. The usual badge of rank was a long fringed shawl. Intermediate rank wore shawl with short fringes and lower grade wore no shawl at all. The military costume was comparative uniformity : conical helmets was regarded as Scythic in character, short, fringed tunics, wide belts or helmet, round caps and long tunics covered in metal scales, belted at the waist. Assyrian woman costume was the long tunic with fringed hem and a long fringed shawl or was a plaid tunic and wide belt over it. They wore gold crown and horned Cap and tiara, ugal (head-dress) and the most ordinary earrings were the drop and the cross shape and necklace was made of the coloured stones and bracelets ended with heads of animal was regarded as Scythy style or adorned with a rosette at the centre.

복합재항공기 연료시스템의 낙뢰보호설계 및 인증 연구 (Research on Aircraft Lightning Protection Design and Certification of Fuel System in Composite Material)

  • 이영제;조원일;전정환;고진환
    • 한국항공운항학회지
    • /
    • 제25권4호
    • /
    • pp.130-140
    • /
    • 2017
  • Lightning protective design of an aircraft fuel system is closely related to the safety of the flight. Recently, composite material in building an aircraft becomes more important because it can reduce the weight of the aircraft. The composite materials decrease the protection against the effect of lightning. Lightning protective design of metal material aircraft has been researched for a long time and the design technique has been announced widely. However, research on the lightning protective design using composite material aircraft is very limited. In this study, lightning protective design for fuel tank structural component, access cover, fuel filler cap and drain valve in carbon fiber composite material aircraft have been presented. To show the compliance with FAA airworthiness standard regarding the presented protection designs, three steps, including lightning strike analysis, lightning environment analysis and certification test, were conducted in accordance with FAA AC 20-53.