• 제목/요약/키워드: Medium Voltage

검색결과 425건 처리시간 0.022초

Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems

  • Pirouz, Hassan Mohammadi;Bina, Mohammad Tavakoli
    • Journal of Power Electronics
    • /
    • 제10권5호
    • /
    • pp.572-578
    • /
    • 2010
  • This paper discusses a transformerless shunt static compensator (STATCOM) based on a modular multilevel converter (MMC). It introduces a new time-discrete appropriate current control algorithm and a phase-shifted carrier modulation strategy for fast compensation of the reactive power and harmonics, and also for the balancing of the three-phase source side currents. Analytical formulas are derived to demonstrate the accurate mechanism of the stored energy balancing inside the MMC. Various simulated waveforms verify that the MMC based STATCOM is capable of reactive power compensation, harmonic cancellation, and simultaneous load balancing, while controlling and balancing all of the DC mean voltages even during the transient states.

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • 정경섭;서용석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF

3-레벨 인버터의 누설전류 제거를 위한 캐리어 기반 MVPWM의 과변조 특성 (Overmodulation Characteristics of Carrier Based MVPWM for Eliminating the Leakage Currents in Three-Level Inverter)

  • 이은철;최남섭;안강순
    • 전력전자학회논문지
    • /
    • 제20권6호
    • /
    • pp.509-516
    • /
    • 2015
  • The overmodulation characteristics of a carrier-based medium vector pulse width modulation (CBMVPWM) are examined in this study. CBMVPWM can completely eliminate leakage currents in a three-phase, three-level inverter using only the switching states with the same common mode voltage even in an overmodulation operation. The analytic equations for the magnitude of the output voltage and the switching frequency are derived for overmodulation operation, and the effect of dead time on the leakage current is demonstrated. This study presents the operating principle of CBMVPWM, basic overmodulation features, and simulations and experiments for operating verification.

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

배전용 S2급 차단기의 차단 성능평가 시험법에 관한 연구 (Study on interrupting test method for class S2 circuit breaker of distribution system)

  • 박병락;조만영;김진석;신희상;김재철
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.132-139
    • /
    • 2011
  • Technical requirements for medium voltage class circuit breaker were harmonized by IEC and IEEE, and IEC newly adopted the requirements for class S2 circuit-breaker for overhead-line with the ratings of high-frequency TRV(Transient Recovery Voltage), which IEEE already adopted. Under these circumstances, KERI(Korea Electrotechnology Research Institute) studied testing technologies and facilities, which enable to perform interrupting capacity tests for class S2 circuit-breaker. As results, KERI could carry out interrupting capacity tests for medium voltage class circuit breaker rated up to 3-phase 52[kV] 40[kA], which satisfies the IEC standard.

Minimization of Torque Ripple for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Unbalanced Grid Condition

  • Park, Yonggyun;Suh, Yongsug;Go, Yuran
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.273-274
    • /
    • 2012
  • This paper investigates control algorithms for a doubly fed induction generator(DFIG) with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Two different control algorithms to compensate for unbalanced conditions are proposed. Evaluation factors of control algorithm are fault ride-through(FRT) capability, efficiency, harmonic distortions and torque pulsation. Zero regulated negative sequence stator current control algorithm has the most effective performance concerning FRT capability and efficiency. Ripple-free control algorithm nullifies oscillation component of active power and reactive power. Ripple-free control algorithm shows the least harmonic distortions and torque pulsation. Combination of zero regulated negative sequence stator current and ripple-free control algorithm control algorithm depending on the operating requirements and depth of grid unbalance presents the most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system.

  • PDF

A Hierarchical Model Predictive Voltage Control for NPC/H-Bridge Converters with a Reduced Computational Burden

  • Gong, Zheng;Dai, Peng;Wu, Xiaojie;Deng, Fujin;Liu, Dong;Chen, Zhe
    • Journal of Power Electronics
    • /
    • 제17권1호
    • /
    • pp.136-148
    • /
    • 2017
  • In recent years, voltage source multilevel converters are very popular in medium/high-voltage industrial applications, among which the NPC/H-Bridge converter is a popular solution to the medium/high-voltage drive systems. The conventional finite control set model predictive control (FCS-MPC) strategy is not practical for multilevel converters due to their substantial calculation requirements, especially under high number of voltage levels. To solve this problem, a hierarchical model predictive voltage control (HMPVC) strategy with referring to the implementation of g-h coordinate space vector modulation (SVM) is proposed. By the hierarchical structure of different cost functions, load currents can be controlled well and common mode voltage can be maintained at low values. The proposed strategy could be easily expanded to the systems with high number of voltage levels while the amount of required calculation is significantly reduced and the advantages of the conventional FCS-MPC strategy are reserved. In addition, a HMPVC-based field oriented control scheme is applied to a drive system with the NPC/H-Bridge converter. Both steady-state and transient performances are evaluated by simulations and experiments with a down-scaled NPC/H-Bridge converter prototype under various conditions, which validate the proposed HMPVC strategy.

Modified Modular Multilevel Converter with Submodule Voltage Fluctuation Suppression

  • Huang, Xin;Zhang, Kai;Kan, Jingbo;Xiong, Jian
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.942-952
    • /
    • 2017
  • Modular multilevel converters (MMCs) have been receiving extensive research interest in high/medium-voltage applications due to its modularity, scalability, reliability, high-voltage capability, and excellent harmonic performance. Submodule capacitors are usually rather bulky because they have to withstand fundamental frequency voltage fluctuations. To reduce the capacitance of these capacitors, this study proposes a modified MMC with an active power decoupling circuit within each submodule. The modified submodule contains an auxiliary half bridge, with its capacitor split in two. Also, the midpoints of the half bridge and the split capacitors are connected by an inductor. With this modified submodule, the fundamental frequency voltage fluctuation can be suppressed to a great extent. The second-order voltage fluctuation, which is the second most significant component in submodule voltage fluctuations, is removed by the proper control of the second-order circulating current. Consequently, the submodule capacitance is significantly reduced. The viability and effectiveness of the proposed new MMC are confirmed by the simulation and experimental results. The proposed MMC is best suited for medium-voltage applications where power density is given a high priority.

Three-Switch Active-Clamp Forward Converter with Low Voltage Stress

  • Park, Ki-Bum;Kim, Chong-Eun;Moon, Gun-Woo;Youn, Myung-Joong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.505-507
    • /
    • 2008
  • A conventional active-clamp forward (ACF) converter is a favorable candidate in low-to-medium power applications. However, the switches suffer from high voltage stress, i.e., sum of the input voltage and the reset capacitor voltage. Therefore, it is not suitable for high input voltage applications such as a front-end converter of which the input voltage is about 400-$V_{dc}$. To solve this problem, three-switch ACF (TS-ACF) converter, which employs two main switches and one auxiliary switch with low voltage stress, is proposed. Utilizing low-voltage rated switches, the proposed converter is promising for high input voltage applications with high efficiency and low cost.

  • PDF

PMIC용 512비트 MTP 메모리 IP설계 (Design of a 512b Multi-Time Programmable Memory IPs for PMICs)

  • 장지혜;하판봉;김영희
    • 한국정보전자통신기술학회논문지
    • /
    • 제9권1호
    • /
    • pp.120-131
    • /
    • 2016
  • 본 논문에서는 back-gate bias 전압인 VNN (Negative Voltage)을 이용하여 5V의 MV (Medium Voltage) 소자만 이용하여 FN (Fowler-Nordheim) tunneling 방식으로 write하는 MTP cell을 사용하여 512비트 MTP IP를 설계하였다. 사용된 MTP cell은 CG(Control Gate) capacitor, TG(Tunnel Gate) transistor와 select transistor로 구성되어 있다. MTP cell size를 줄이기 위해 TG transistor와 select transistor를 위한 PW(P-Well)과 CG capacitor를 위한 PW 2개만 사용하였으며, DNW(Deep N-Well)은 512bit MTP cell array에 하나만 사용하였다. 512비트 MTP IP 설계에서는 BGR을 이용한 voltage regulator에 의해 regulation된 V1V (=1V)의 전압을 이용하여 VPP와 VNN level detector를 설계하므로 PVT variation에 둔감한 ${\pm}8V$의 pumping 전압을 공급할 수 있는 VPP와 VNN 발생회로를 제안하였다.