1 |
R.E. Betz, T. Summerst, T. Furney, "Using a cascaded h-bridge STATCOM for rebalancing unbalanced voltages," The 7th International Conference on Power Electronics, 2007.
|
2 |
R. E. Betz, T. Summers, and T. Furney. "Symmetry compensation using a H-bridge multilevel STATCOM with zero sequence injection," IEEE Industry Applications Conference, Oct. 2006.
|
3 |
R. Marquardt, A. Lesnicar, "New concept for high voltage – modular multilevel converter," Deutsch- Koreanisches Symposium, 2004.
|
4 |
H. Mohammadi Pirouz, M. Tavakoli Bina, "New transformerless STATCOM topology for compensating unbalanced medium-voltage loads," EPE'09, Sep. 2009.
|
5 |
H. I. Eini, S. Farhangi, J. L. Schanen, M. K. Fard, "A fault-tolerant control strategy for cascaded h-bridge multilevel rectifiers," Journal of Power Electronics, Vol. 10, No. 1, pp.34-42, Jan. 2010.
과학기술학회마을
DOI
ScienceOn
|
6 |
G. K. Kasal, B. Singh, "H-bridge VSC with a t-connected transformer for a 3-phase 4-wire voltage and frequency controller of an isolated asynchronous generator," Journal of Power Electronics, Vol. 9, No. 1, pp.43-50, Jan. 2009.
과학기술학회마을
|
7 |
H. Akagi, S. Inoue, T. Yoshii, " Control and performance of a transformerless cascade PWM STATCOM with star configuration," IEEE Transactions on Industry Applications, Vol. 43 , No. 4, pp. 1041-1049, Jul./Aug. 2007.
DOI
ScienceOn
|
8 |
Fang Z. Peng, John Wang, McKeever, Donald J. Adams, "A power line conditioner using cascade multilevel inverters for distribution systems," IEEE Transactions on Industrial Application, Vol. 34, No. 6, pp.1293-1298, Nov./Dec. 1998.
DOI
ScienceOn
|
9 |
Y. M. Park, H. S. Ryu, H. W. Lee, M. G. Jung, S. H. Lee, "Design of a cascaded H-Bridge multilevel inverter based on power electronics building blocks and control for high performance," Journal of Power Electronics, Vol. 10, No. 3, pp.262-269, Mar. 2010.
과학기술학회마을
DOI
ScienceOn
|
10 |
C. K. Lee, J.S K. Leung, S.Y R. Hui, H.S.H. Chung, "Circuit-level comparison of STATCOM technologies," IEEE Transactions on Power Electronics, Vol. 18, No. 4, pp. 1084-1092, Jul. 2003.
DOI
ScienceOn
|
11 |
Fang Z. Peng, Jin Wang, "A universal STATCOM with delta-connected cascade multilevel inverter," IEEE PESC'04, Jun. 2004.
|
12 |
S. Rohner, S. Bernet, M. Hiller, R. Sommer, "Modulation, losses and semiconductor requirements of modular multilevel converters," IEEE Transactions on Industrial Electronics, IEEE Early Access, 2009.
|
13 |
L. A. Moran, J. W. Dixon, and R. R. Wallace, "A three-phase active power filter operating with fixed switching frequency for reactive power and current harmonic compensation," IEEE Trans. Ind. Electron., Vol. 42, No. 4, pp. 402-408, Aug. 1995.
DOI
ScienceOn
|
14 |
Akagi, Watanabe, Aredes, "Instantaneous power theory and applications to power conditioning," The Institute of Electrical and Electronics Engineers Inc., 2007.
|
15 |
R. Gupta, A. Ghosh, and A. Joshi, "Switching characterization of cascaded multilevel-inverter-controlled systems," IEEE Transactions on Industrial Electronics, ol. 55, no. 3, pp. 1047-1058, Mar. 2008.
DOI
ScienceOn
|
16 |
M. Hiller, D. Krug, R. Sommer, S. Rohner, "A new highly modular medium voltage converter topology for industrial drive applications," 13th European Conference on Power Electronics and Applications, 2009.
|
17 |
M. Hagiwara, H. Akagi, "Control and experiment of pulsewidthmodulated modular multilevel converters," IEEE Transactions on Power Electronics, Vol. 24, No. 7, pp 1737-1746, Jul. 2009.
DOI
ScienceOn
|
18 |
M. Tavakoli Bina, A.K.S Bhat, "Averaging technique for the modeling of STATCOM and active filters," IEEE Transactions on Power Electronics, Vol. 23, No. 2, pp. 723-734, Mar. 2008.
DOI
ScienceOn
|
19 |
Pee-Chin Tan, R.E. Morrison, D.G. Holmes, "Voltage form factor control and reactive power compensation in a 25-kV electrified railway system using a shunt active filter based on voltage detection," IEEE Transactions on Industry Applications, Vol. 39, No. 2, pp. 575-581, Mar./Apr. 2003.
DOI
ScienceOn
|
20 |
R. Marquardt, "Stromrichters chaltungen mitverteilten energiespeichern," German Patent DE 10 103 031, Jan. 24, 2001.
|