• Title/Summary/Keyword: Medical technologists

Search Result 238, Processing Time 0.02 seconds

Radiation Exposure Dose on Persons Engaged in Radiation-related Industries in Korea (한국에서 방사선 관련 종사자들의 개인피폭선량 실태에 관한 연구)

  • Lim, Bong-Sik
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.185-195
    • /
    • 2006
  • Purpose: This study investigated the status of radiation exposure doses since the establishment of the "Regulations on Safety Management of Diagnostic Radiation Generation Device" in January 6, 1995. Method: The level of radiation exposure in people engaged or having been engaged in radiation-related industries of inspection organizations, educational organizations, military units, hospitals, public health centers, businesses, research organizations or clinics over a 5 year period from Jan. 1, 2000 to Dec. 31, 2004 was measured. The 149,205 measurement data of 57,136 workers registered in a measurement organization were analysed in this study. Frequency analysis, a Chi-square test, Chi-square trend test, and ANOVA was used for data analysis. Results: Among 57,136, men were 40,870(71.5%). 50.3% of them were radiologic technologists, otherwise medical doctors(22.7%), nurse(2.9%) and others(24.1%). The average of depth radiation and surface radiation during the 5-year period were found to decrease each year. Both the depth radiation and surface radiation exposure were significantly higher in males, in older age groups, in radiological technologists of occupation. The departments of nuclear medicine had the highest exposure of both depth and surface radiation of the divisions of labor. There were 1.98 and 2.57 per 1,000 person-year were exposed more than 20 mSv(limit recommended by International Commission on Radiological Protection) in depth and surface radiation consequently. Conclusion: The total exposure per worker was siginifcantly decreased by year. But Careful awareness is needed for the workers who exposed over 20 mSv per year. In order to minimize exposure to radiation, each person engaged in a radiation-related industry must adhere to the individual safety management guidelines more thoroughly. In addition, systematic education and continuous guidance aimed at increasing the awareness of safety must be provided.

  • PDF

Discrepancy and Correlation in the renal length between Kidney CT and 99mTc-DMSA Renal scan (신장 CT 검사와 99mTc-DMSA Renal Scan 검사에서 측정한 신장 길이의 차이 및 상관분석)

  • Jung, Woo-Young;Shim, Dong-Oh;Lee, Dong-Hun;Choi, Jae-Min
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.1
    • /
    • pp.15-20
    • /
    • 2021
  • Purpose This article studies the relationship between the length of a kidney measured by two scanning methods: Kidney Computed Tomography (CT) and 99mTc-Dimercaptosuccinic acid (DMSA) renal scan. Kidney CT provides a better anatomic assessment, while 99mTc-DMSA renal scan is superior in the kidney function test. Materials and Methods From January to December of 2019, two hundred patients who had Kidney CT and Tc99m-DMSA renal scan were chosen for this study. SPSS17.0 was selected for statistical analysis. Results Due to the effect of the breathing and resolution of 99mTc-DMSA renal scan, it showed the kidney's relatively longer length than the length of Kidney CT. For the same kidney, the length comparison among different brands' Gamma cameras was negligible. The length difference within the same age group did not show a noticeable discrepancy. However, there was a length difference between the radio technologists. Kidney CT and 99mTc-DMSA renal scan indicated a strong positive correlation between the length of the left and right kidney. Conclusion It is necessary to establish a standardized measurement method for measuring kidney length using 99mTc-DMSA renal scan. The kidney's functional changes and length changes are indications of Kidney diseases. Especially, pediatric patients tend to use 99mTc-DMSA renal scan for assessing the kidney's shape and the function to avoid potential radiation exposure during the Kidney CT. Therefore, it is significant to provide not only the kidney's functional information but also an anatomic analysis, including the kidney's size, length, and location through the 99mTc-DMSA renal scan.

A Study on Welfare Satisfaction of the University Hospital Radiological Technologist (대학병원방사선사의 복지만족에 관한 연구)

  • Jeong, Bong-Jae;Choi, Il-Hong;Park, Ji-Koon;Kang, Sang-Sik;Park, Hyung-Hu;Noh, Si-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.133-138
    • /
    • 2016
  • This research is a study on the welfare satisfaction of radiological technologists in university hospital, and was conducted in order to analysis of welfare factors and improvements. The survey was conducted on radiological technologist of a university hospital in Gyeongnam from July 14th 2014 to August 14th 2014, and we analyzed 121 of the questionnaire, which was retrieved by distributing. As a result, we looked at the welfare level of satisfaction by welfare hospital factors, each of the satisfaction scores were living welfare supports($2.83{\pm}0.43$), financial supports($4.25{\pm}0.65$), housing supports($2.28{\pm}0.46$), educational supports($2.58{\pm}0.50$), health medical supports($3.02{\pm}0.56$), culture and leisure supports($2.79{\pm}0.45$), other welfare supports($2.70{\pm}0.48$) points. The level of satisfaction with the hospital welfare support factors of average score level it was analyzed. It is important that is providing effective hospital welfare through survey for hospital welfare needs and benchmarking of welfare system of general corporate.

Factors Affecting Occupation Awareness for Dental Hygienist in High School Students (고등학생의 치과위생사에 대한 직업 인지 관련 요인)

  • Cho, Young-Sik;Hwang, Hye-Rim;Joo, Seung-Mi;Choi, Jung-Yoon;Hwang, Mi-Ra
    • Journal of dental hygiene science
    • /
    • v.11 no.4
    • /
    • pp.293-297
    • /
    • 2011
  • The purpose of this study was to evaluate recognition of occupation title for dental hygienist in high school students. Total 210 students of one high school completed a self-reported questionnaire on sociodemographic characteristics, dental service utilization and occupation title awareness for health care personnels. Female and science tract students showed higher level of awareness for dental hygienist but showed no differences according to dental service utilization pattern. The study showed association between occupation recognition for dental hygienist and other health technicians. But there were no association between occupation awareness for dental hygienist and dentist, nurse. Gender, occupation recognition for medical laboratory technologists and physical therapist affect occupation recognition for dental hygienist.

Development and Implementation of a Critical Pathway for Prevention of Adverse Reactions to Contrast Media for Computed Tomography (CT 조영제의 부작용 예방을 위한 표준진료지침서의 개발과 적용)

  • Jang, Keun-Jo;Kim, Myeong-Goo;Yoo, Beong-Gyu;Kweon, Dae-Cheol
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.39-46
    • /
    • 2007
  • The purpose of this study is to develop a critical pathway (CP) for the prevention of adverse reactions to contrast media for computed tomography. The CP was developed and implemented by a multidisciplinary group in Seoul National University Hospital. The CP was applied to CT patients. Patients who underwent CT scanning were included in the CP group from March in 2004. The satisfaction of the patients with CP was compared with non-CP groups. We also investigated the degree of satisfaction among the radiological technologists and nurses. The degree of patient satisfaction with the care process increased patient information(24%), prevention of adverse reactions to contrast media(19%), pre-cognitive effect of adverse reactions to contrast media(39%) and information degree of adverse reactions to contrast media(19%). This CP program can be used as one of the patient care tools for reducing the adverse reactions to contrast media and increasing the efficiency of care process in CT examination settings.

  • PDF

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

The Pathology of Infection in the Department of Radiology (영상의학과 검사실의 감염 실태)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.211-218
    • /
    • 2012
  • This study was performed to understand the bacteriologic contamination level of radiological equipments which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipments and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipments and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

The Comprehension of health care service bill of radiological technologist and dental hygienist and the study of necessity of including the service supply resources (방사선사 및 치위생사의 건강관리서비스법안 이해와 서비스 제공요원 포함의 필요성에 관한 연구)

  • Son, Soon-Yong;Jeong, Mi-Ae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1696-1702
    • /
    • 2011
  • This study is to present basic materials to further selection of details of health care service bill and supply resources by analysing the consciousness of radiological technologist and dental hygienist about health care service bill proposed for prevention and early diagnosis of a disease through the improvement of living habit. Subjects were 359 of dental hygienists and radiological technologists investigated from 2010 July to September for three months. As the result, recognition level on health care service bill or its details was less than 30.0% but the opinion that health care service bill is necessary was 78.0%. In its additional item, radiological technologist hope to be maintained currently, and 82.3% of the dental hygienist hope to be added, their prefered additional item was dental disease. A dominant opinion was that dental hygienist and radiological technologist as a service supply personnel were included, and their intention to participate was 8.1 in average. In conclusion, the health care service bill is indispensable, but more systematic study is required based on collecting various opinions about major contents and service provider. Particularly it is inevitable to include the health human resources such as experienced dental hygienist and radiological technologist who had completed the regular course of health education and are having continuous clinical discipline.

Comparison of WBCs and RBCs Concordance between the Cobas u 701 Analyzer and Three Manual Microscopy Methods in Urine Sediment (소변 침전물에서 Cobas u 701 Analyzer와 세 가지 수동 현미경검사법의 백혈구와 적혈구의 일치도 비교)

  • Hyeok-Jae LEE;Min-Hyeok LEE
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.2
    • /
    • pp.82-92
    • /
    • 2023
  • Urine sediments are performed by a microscopic examination of centrifuged urine by medical technologists. This study examined different urine sediment preparation procedures. The 107 fresh urine specimens that tested positive from white blood cells (WBCs) and red blood cells (RBCs) in the urine dipstick test and the cobas u 701 analyzer, respectively, were selected for manual microscopy. This study evaluated an automated urine sediment analyzer and three manual microscopy methods for WBCs and RBCs. The methods were performed according to the test guidelines. The coefficients of determination between the cobas u 701 analyzer and the Korean Association of Quality Assurance for Clinical Laboratory (KAQACL) for WBCs and RBCs were r2=0.977 and r2=0.970, respectively. The concordance rates between the cobas u 701 analyzer and KAQACL for WBCs and RBCs were 74.8% and 77.6%, respectively. A good correlation and concordance with the automatic analyzer were shown when the specimens were prepared and examined using the KAQACL method. Consequently, the differences in the urine sediment preparation procedures affected the sediment concentrations, influencing the cell number per high power field (HPF).

Pediatric Radiation Examination by Development of Bismuth Shield Research on Radiation Exposure (비스무스 차폐체 개발을 통한 소아 방사선검사의 피폭에 관한 연구)

  • Hoon Kim;Yong-Keun Kim;Joon-Nyeon Kim;Seung-Hyun Wi;Eun-Kyung Park;Myung-Jun Chae;Bu-Gil Baek;Eun-Hye Kim;Cheong-Hwan Lim
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.205-211
    • /
    • 2024
  • Currently, with the development of technologies, X-ray examinations for medical examinations at hospital is increasing. This study was conducted to help reduce radiation exposure by measuring the exposure dose received by pediatric patients and the spatial dose of the X-ray room. Dosimeters were installed in the eyeball, thyroid gland, breast, gonads and 4 directions at a distance of 30 cm, 40 cm, 50 cm from the phantom. The dose was measured ten times each, before, and after the application of the bismuth shield under the examination conditions of the head, chest, and abdomen of pediatric patients. Under the condition of head examination, when a shielding was applied, the dose reduction rate was 68.58% for the eyeball, 72.88% for the thyroid, 84.2% for the breast, and 72.36% for the gonad. The chest examination showed reductions of 19.56% eyeball, 56.98% thyroid, 1.21% breast, and 0.68% gonad. The abdominal examination showed reduction rates of 2.6% eyeball, 10.67% thyroid, 19.85% breast, and 82.02% gonad. Spatial dose decreased by 62.25% at 30 cm, 61.16% at 40 cm, and 68.68% at 50 cm. When the bismuth shield was applied, there was a decrease in dose across all examinations, as well as a reduction in spatial dose. Continued research on the use of bismuth shields will help radiological technologists achieve their goal of dose reduction.