• Title/Summary/Keyword: Medical image communication

Search Result 270, Processing Time 0.031 seconds

Depending on PACS Operating System Differences Analysis of Usefulness of Lossless Compression Method in Medical Image Upload: SNR, CNR, Histogram Comparative Analysis (PACS운영 시스템 차이에 따른 의료 영상 업로드 시 무손실 압축 방식의 유용성 분석: SNR, CNR, Histogram 비교 분석을 중심으로)

  • Choi, Ji-An;Hwang, Jun-Ho;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.3
    • /
    • pp.299-308
    • /
    • 2018
  • This study focused on the fact that medical images that are issued at different hospitals may affect image quality on PACS when different software is used. A university hospital image was copied to the DICOM file and registered on the PACS of the university hospital B. The capacity and image quality of the software used in the university hospital were evaluated by SNR, CNR and histogram. As the compression ratio increased, SNR and CNR tended to decrease. Note that Lossless Compression decreased the data size by half compared to No Compression, but SNR and CNR did not change. As a result of the histogram analysis, the information loss due to the underflow phenomenon was conspicuous. When moving to another hospital, No compression or lossless compression method should be used. In conclusion, it is useful to use the lossless compression method, considering waiting time and economic efficiency in uploading.

Segmentation and 3-Dimensional Reconstruction of Liver using MeVisLab (MeVisLab을 이용한 간 영역 분할 및 3차원 재구성)

  • Shin, Min-Jun;Kim, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1765-1772
    • /
    • 2012
  • Success rate of transplantation of body organs improved due to development of medical equipment and diagnostic technology. In particular, a liver transplant due to liver dysfunction has increased. With the development of image processing and analysis to obtain the volume for liver transplantation have increased the accuracy and efficiency. In this thesis, we try to reconstruct the regions of the liver within three dimensional images using the mevislab tool, which is effective in quick comparison and analysis of various algorithms, and in expedient development of prototypes. Liver is divided by applying threshold values and region growing method to the original image, and by removing noise and unnecessary entities through morphology and region filling, and setting of areas of interest. It is deemed that high temporal efficiency, and presentation of diverse range of comparison and analysis module application methods through usage of MeVisLab would make contribution towards expanding of baseline of medical image processing researches.

Korean Version of Body Image Dysmorphic Disorder Examination Self Report(BDDE-SR) with College Students (한국판 신체 이형장애 자가 평가척도의 표준화 연구 : 대학생들을 대상으로)

  • Lee, Hye-Jin;Choi, Eun-Young;Do, Jin-A;Lim, Myung-Ho;Paik, Ki-Chung;Lee, Kyung-Kyu;Kim, Hyun-Woo
    • Anxiety and mood
    • /
    • v.5 no.2
    • /
    • pp.112-119
    • /
    • 2009
  • Objective : Recently, there is an increasing trend of attachment to physical appearance of individuals in many persons with spread of social concern through mass communication. Domestically, several studies has been performed, but they were limited to obesity mainly for juveniles or female college students. Therefore, purpose of this study were to standardize Body image dysmorphic disorder examination self report with male and female college students in Cheonnan area. Methods : This study were total 825 college students in Cheonan area. Subject group are consist of 393 males (47.6%) and 427 females (51.8%), and the mean age was $22.28{\pm}3.24$ years old. Results : The BDDE-SR had adequate internal consistency (Cronbach's alpha=.93) and test-retest (r=.82) and interator reliability. Four factors were extracted by factor analysis with the Varimax rotation. They were 'the camouflage and comparison factor', 'the self-consciousness and negative self-evaluation factor', 'the avoidance factor', and 'the distressing and embarassment factor'. The total score of BDDE-SR was $50.8{\pm}27.1$, female's score ($59.2{\pm}25.5$) was statistically higher than male's score ($41.85{\pm}25.84$). Conclusion : It is considered that BDDE-SR is reliable instrument for body image dissatisfaction, provided correct information in predicting clinical status of Body dysmorphic disorder that is most largely influenced by individual psychologic factor and family system.

  • PDF

Efficient Sharing System of Medical Information for Interoperability between PACS System (PACS 시스템간 상호운용성을 위한 효율적인 의료 정보공유시스템)

  • Cho, Ik-Sung;Kwon, Hyeong-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.3
    • /
    • pp.498-504
    • /
    • 2009
  • In the PACS system, the radiology image(X-ray) and its report are saved as separated parts. The exchange of the radiology image between clinics that installed this system are easily achieved by the DICOM standardization. But it is difficult to exchange the radiology report between clinics because a solution of PACS system is different according to manufacturers. The radiology report should be unified the vocabulary and the type of code for effective sharing and exchanging, and also the radiology image and its report should be integrated for the accurate analysis. In this paper, we propose the sharing system of medical information based on HL7-CDA, it defines the templates and converts the structured documents. For this purpose, we design the XML schema of the radiology report and turn the DICOM files into defined schema. The HL7-CDA documents based on XML is easily displayed on web browser and can help the diagnosis by inserting the radiology image.

Spine Computed Tomography to Magnetic Resonance Image Synthesis Using Generative Adversarial Networks : A Preliminary Study

  • Lee, Jung Hwan;Han, In Ho;Kim, Dong Hwan;Yu, Seunghan;Lee, In Sook;Song, You Seon;Joo, Seongsu;Jin, Cheng-Bin;Kim, Hakil
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.3
    • /
    • pp.386-396
    • /
    • 2020
  • Objective : To generate synthetic spine magnetic resonance (MR) images from spine computed tomography (CT) using generative adversarial networks (GANs), as well as to determine the similarities between synthesized and real MR images. Methods : GANs were trained to transform spine CT image slices into spine magnetic resonance T2 weighted (MRT2) axial image slices by combining adversarial loss and voxel-wise loss. Experiments were performed using 280 pairs of lumbar spine CT scans and MRT2 images. The MRT2 images were then synthesized from 15 other spine CT scans. To evaluate whether the synthetic MR images were realistic, two radiologists, two spine surgeons, and two residents blindly classified the real and synthetic MRT2 images. Two experienced radiologists then evaluated the similarities between subdivisions of the real and synthetic MRT2 images. Quantitative analysis of the synthetic MRT2 images was performed using the mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). Results : The mean overall similarity of the synthetic MRT2 images evaluated by radiologists was 80.2%. In the blind classification of the real MRT2 images, the failure rate ranged from 0% to 40%. The MAE value of each image ranged from 13.75 to 34.24 pixels (mean, 21.19 pixels), and the PSNR of each image ranged from 61.96 to 68.16 dB (mean, 64.92 dB). Conclusion : This was the first study to apply GANs to synthesize spine MR images from CT images. Despite the small dataset of 280 pairs, the synthetic MR images were relatively well implemented. Synthesis of medical images using GANs is a new paradigm of artificial intelligence application in medical imaging. We expect that synthesis of MR images from spine CT images using GANs will improve the diagnostic usefulness of CT. To better inform the clinical applications of this technique, further studies are needed involving a large dataset, a variety of pathologies, and other MR sequence of the lumbar spine.

Robust Watermarking in Medical Images Using by Polar Transformation (의료영상에서 Polar 변환을 적용한 강인한 워터마킹 기법)

  • 남기철;박무훈
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.379-385
    • /
    • 2004
  • Medical images are being managed more by PACS in general medical institutions. It is important to protect patients from being invaded their privacy related to the images. It is also necessary to confirm the ownership, the right of property of the medical images and notice whether the data are modified. In this paper, we propose a robust watermarking against RST attacks in medical images on the PACS. The proposed scheme modifies and improves Log-Polar Mapping and Fourier Mellin Transform in order to realize and recover serious image degradation and watermark data loss caused by the conversion between cartesian coordinate and log-polar coordinate. We used the radius and theta Look Up Table to solve the realization of the Fourier Mellin Transform, and inserted a watermark into 2D-DFT magnitudes using Spread Spectrum. Experimental results shows that this method are robust to rotation attack.

The Cerebro-region Extraction Using Cellular Automata (셀룰러 오토마타를 이용한 뇌 영역 추출에 관한 연구)

  • 이승용;허창우;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.7
    • /
    • pp.1551-1555
    • /
    • 2003
  • This paper describes the extraction method for cerebro-region using cellular automata from the cerebrum MR images. The cerebro-region extracted from applying the cellular automata rules obtained from histogram distribution analysis after removing the background image from the cerebro-region by determining the critical value. The experiment results showed that PSNR is 42㏈ on the image quality and the correlation factor is estimated 98%. And the result can be used as the medical auto-diagnostics system of cerebrum.

A Study on the Development of a PC Based Mini-PACS (PC 기반 Mini-PACS 개발에 관한 연구)

  • Kim, H.;Kim, D.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.61-64
    • /
    • 1996
  • Currently many researches are going on a Picture Archiving and Communication System (PACS) which can handle a large number of image data very efficiently. However, the price of those systems are very expensive to a small and medium hospital. In this paper, we developed a PC based Mini-PACS at a low price with a high performance. The main components of the designed system are: Image processing and display for a diagnosis, Client/Server database management system, Multi-monitor display system, Connection through the World Wide Web with Common Gateway Interface.

  • PDF

Digital Halftoning using DCT (DCT를 사용한 디지털 하프토닝)

  • Kwon, Young-Man;Kim, Kyuho;Kwon, Hyeong-Joon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.79-85
    • /
    • 2013
  • In this paper, we discussed the traditional methods of generating digital halftoning image and DCT transform. Then we propose a new and simple halftoning algorithm that is based on DCT transformation. We do the feasibility test to verify the proposed algorithm. So we assessed several images generated by adjusting weights of DCT coefficients. As a result, we got the better result for weights of the ramp function type than for weights of the step function type through experiment. As a simple application, we can apply our algorithm to the MPEG video for generating the halftoning video.

Design of DICOM Standard Interface Module for Medical Image Standardization (의료영상 표준화를 위한 DICOM 표준 인터페이스 모듈 설계)

  • Kim, Sung-Hyun;Jeon, Jae-Hwan;Kim, Gwan-Hyung;Kang, Sung-In;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.221-224
    • /
    • 2010
  • PACS(Picture Archiving Communication System)를 바탕으로 하는 DICOM(Digital Imaging and Communications in Medicine)은 주요 의료영상장비들 사이에 데이터와 영상을 효율적으로 교환하고 전송할 수 있도록 마련한 표준안으로 현재 대부분의 최신형 의료영상장비(CT, MR, DSA, CR(Computed Radiology), 초음파검사, 핵의학검사, 내시경검사, 조직병리검사, 등)들은 의료 영상 분야의 국제 표준인 DICOM 표준방식에 의해 영상을 제공하고 있다. 최근 이러한 의료영상장비들은 독립적으로 사용하기보다는 의료수술 모니터링 장비 등의 비 의학영상장비와 서로 연계하여 사용하는 경우가 많아졌다. 그러나 이러한 의료수술 모니터링 장비들은 DICOM 표준 데이터를 고려하지 못하므로 PACS를 통한 데이터 연계에 어려움이 있다. 따라서 본 논문에서는 표준 DICOM 포맷과 의료수술 모니터링 장비의 데이터 구조를 분석하여 non-DICOM 의료수술 모니터링 장비의 PACS 연동을 위한 방안을 제안하였다.

  • PDF