• Title/Summary/Keyword: Medical equipment

Search Result 1,277, Processing Time 0.032 seconds

The Research of Design Development for Strengthening Competitiveness of Domestic Medical Instrument Industry -Focused on C-Arm Surgical X-Ray Design- (국내 의료기기산업 경쟁력 강화를 위한 디자인개발에 관한 연구 -이동형 영상진단기기 디자인을 중심으로-)

  • Han, Il-Woo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.51-60
    • /
    • 2004
  • The medical instrument industry which is one of the high value added industry has been neglected on the various system and political support because it has been recognized as an unknown field to the public although it is the very easy-approaching field for the export market that minimize a technological gap between advanced country and Korea. Especially, the product design that is very important element for the efficient medical treatment and the psychological stabilization of patient is a typical field of lack of investment and support by the unconcern and lack of understanding of design. Therefore this research suggests the current problem of design with the general inquiry of internal and external market situation and domestic medical instrument industry and also it has the conclusion of an alternative proposal for the solution with the design development processing of a moving type-image diagnostic equipment. We will emboss the importance of design competitiveness, suggest the model and basic data to the medical instrument company that starts later, and be a role of inspiration for the lasting investible desire with this research.

  • PDF

Research for Implementation of biomedical signal measurement platform using the Cortex-A9 (Cortex-A9을 이용한 생체신호 측정 공통플랫폼 구현에 대한 연구)

  • Kim, Do-kyun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.493-495
    • /
    • 2014
  • With the expansion of the medical field worldwide, interest in medical devices is also increasing. However, since the field of the special nature of the medical device, is utilized in accordance with the respective devices is determined, the amount depending on the fields, to purchase a medical device is increased. Function digital parts (such as ECG, SpO2) are similar to each other, but there is a disadvantage by applying the method of designing separate each product, the reproduction of the program is difficult, Each product, each product the various OS is used, so that either can not be reused even if a program for the same function, it takes time to develop additional. In this paper, I would like to propose a study of the implementation of the platform of the biological signal of medical equipment to try solve the problems of the medical equipment of these.

  • PDF

A Study on the Facility and Equipment of Laboratory Medicine in General Hospital - Focused on more than 550 bed sized hospitals (종합병원 진단검사의학과 검사실의 시설 설비 현황 조사 - 550 병상 이상 종합병원을 중심으로)

  • Kim, Youngaee;Song, Sanghoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.1
    • /
    • pp.73-84
    • /
    • 2020
  • Purpose: Though Korean healthcare services have been upgraded, infection and fire had been broken out in general hospitals. And higher concerns about quality assessment made it to clinical laboratory design guideline studies. So, this study investigates the facilities, equipment and personnel of laboratory medicine focusing on more than five hundred fifty bed hospital, and contributes to make guidelines for safety and efficiency in lab. Methods: Questionnaires to supervisor technologist and field surveys to medical laboratories in korean hospitals have been conducted for the data collection. 16 answers have been analysed statistically by MS Excel program. Results: Most of the sample tests such as hematology, clinical chemistry, immunology, transfusion, urinalysis, microbiology and molecular diagnosis are performed by more than 80% in large sized general hospital laboratory. In the test methods, automatic analyzers are used up to 80%, total laboratory automation up to 43% in clinical chemistry and immunology, and manual tests in all sorts of the test. There are placed in single lab or two and three labs above the ground, which are all in semi-open lab. There is some correlation with the number of specimens and the number of lab people depending on the number of hospital beds. Laboratory environment shows that work distance is good, but evacuation path width, visibility, separation of staff area from automatic analyzer, and equipment installations are needed to have more spaces and gears. Most of the infection controls are equipped with mechanical ventilation, air-conditioning, washbasin and wastewater separation, BSC installation and negative pressure lab room. Implications: Although the laboratory space area is calculated considering the number of hospital beds, type of tests and number of staff, hospital's expertise and the samples numbers per year should be taken into account in the planning of the hospital.

Analysis of Radiation Exposure Dose according to Location Change during Radiation Irradiation

  • Chang-Ho Cho;Jeong-Lae Kim
    • International Journal of Advanced Culture Technology
    • /
    • v.12 no.2
    • /
    • pp.368-374
    • /
    • 2024
  • During an X-ray examination, the beam of radiation is dispersed in many directions. We believe that managing radiation dose is about providing transparency to users and patients in the accurate investigation and analysis of radiation dose. The purpose of measuring the radiation dose as a function of location is to ensure that medical personnel using the equipment or participating in the operating room are minimally harmed by the different radiation doses depending on their location. Four mobile diagnostic X-ray units were used to analyze the radiation dose depending on the spatial location. The image intensifier and the flat panel detector type that receives the image analyzed the dose by angle to measure the distribution of the exposure dose by location. The radiation equipment used was composed of four units, and measuring devices were installed according to the location. The X-ray (C-arm) was measured by varying the position from 0 to 360 degrees, and the highest dose was measured at the center position based on the abdominal position, and the highest dose was measured at the 90° position for the head position when using the image intensifier equipment. The operator or medical staff can see that the radiation dose varies depending on the position of the diagnostic radiation generator. In the image intensifier and flat panel detector type that accepts images, the dose by angle was analyzed for the distribution of exposed dose by position, and the measurement method should be changed according to the provision of dose information that is different from the dose output from the equipment according to the position.

A Survey of Utilizing Status and Demand for Medical Devices in Traditional Korean Medicine (한방의료기기 사용 현황 및 개발 수요에 대한 조사 연구)

  • Nam, Dong-Hyun
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.69-79
    • /
    • 2013
  • Objectives: The aim of this survey was to investigate utilization, intended use, problems with and demand for medical devices by surveying members of the traditional Korean medical society. Methods: We distributed questionnaires to 13,957 traditional Korean medical doctors via e-mail, and received replies from 1,225. The questionnaire consisted of 4 multiple-choice questions for survey respondent information, 8 multiple-choice questions about the status of medical devices utilizing, and a short answer question about the demand for medical devices. Results: Use of medical devices in traditional Korean medical clinics is common. Diagnostic medical devices are mainly used to assess the patient's condition and to establish a close rapport with clients. In case of therapeutic medical devices, they are usually used for secondary treatment. Issues with traditional Korean medical devices currently in use were ineligibility for national health insurance, low reliability, uncertain validity, and high price. In development of traditional Korean medical equipment, the need for diagnostic medical devices was greater than for therapeutic, and the need for the recording and analysis of medical image data and visualization of medical information was great. Conclusions: There is growing demand for facilitating the development and commercialization of traditional Korean medical devices. To satisfy this demand, research on evaluation indicators that reflect functional and structural clinical information and how to clinically assess the indicators should proceed.

Opinion Survey of Health Center Officers on Rural Health Service Improvement Project (농어촌의료(農漁村醫療)서비스 개선사업(改善事業)에 대한 보건소(保健所) 공무원(公務員)의 인식도(認識度))

  • Kim, Young-Gil;Park, Jae-Yong;Kam, Sin;Han, Chang-Hyun;Cha, Byung-Jun
    • Journal of agricultural medicine and community health
    • /
    • v.23 no.2
    • /
    • pp.175-192
    • /
    • 1998
  • This study was performed investigate the opinion of civil servants in Health center about Rural Health Service Improvement Project The survey by mail was carried out for 447 servants of 25 health centers in Kyungsangbuk-do and the data were collected through self-administered questionnaires to servants about need, participation, concern, and comprehension for the project and satisfied with current facility and equipment of health center. The results were as follows. Generally considered, 48.2% of the improved health center servants was satisfied with health center building and 14.0% or 24.1% of the improving or unimproved center was. About the location of health center, 37.7% of the improved health center servants was satisfied, 25.9% of the unimproved center was. Of the improved health center servants, 43% was satisfied with the medical equipment but in unimproved place, the dissatisfaction was appeared higher than any other place. 49.7% of respondents was participated in making out the Rural Health Service Improvement Project. 50.6% was interested in this project. In the improved area. 65.5% of health center servants replied that the mayor's or county executive's concern about this project was high and 46.5% in councilors but in the unimproved area. their concern was low. About the contents of the project. 24,6% of the servants in the improved center, only 15.2% in unimproved center replied that they had known well. After making out the plan, 13.6% of respondents was unsatisfied with this plan and 17.1% replied that the estimating method of selecting the project area was not good. After the improvement of institution and equipment, 86.1% of health center servants answered that the medical service provided by health center would increase but 59.2% replied that the residents' utilization rate of private medical facility would decrease. The servants of the improved health center replied that the recognition about the developing will of health service(91.2%), the efficiency(91.2%), the quality of health and medical service(93.0%), the amount of health project(91.2%) were improved. In health center which had already improved the institution and equipment, 88.5% of servants replied that the residents' utilization for health center was increased. So, this project should be continuously carried out for health center and health center must develope new project to fit region condition.

  • PDF

Evaluation of Reliability about Short TAT (Turn-Around Time) of Domestic Automation Equipment (Gamma Pro) (국산 자동화 장비(Gamma Pro)의 결과보고시간 단축에 대한 유용성 평가)

  • Oh, Yun-Jeong;Kim, Ji-Young;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.197-202
    • /
    • 2010
  • Purpose: Recently, many hospitals have been tried to increase the satisfaction of the outpatients through blood-gathering, exam, result notice and process in a day. Each laboratory has been used the automatic equipment for the rapid requests of the result notice and the increase of the reliability and efficiency. Current automatic equipments that have been limited short TAT(Turn-Around Time)because of the restricted batch lists and 1 tip-5 detectors. The Gamma Pro which is made in Korea to improve the shortcomings of existing automation equipment, complemented with capacity to perform a wide range of domestic automation equipment. In this study, we evaluated the usefulness and reliability of short TAT by comparing Gamma Pro with current automatic equipment. Materials and Methods: We studied the correlation between Gamma Pro and RIA-mat 280 using the respective 100 specimens of low or high density to the patients who were requested the thyroid hormone test (Total T3, TSH and Free T4) in Samsung Medical Center Sep. 2009. To evaluate the split-level Gamma Pro, First, we measured accuracy and carry over on the tips. Second, the condition of optimal incubation was measured by the RPM (Revolution Per Minute) and revolution axis diameter on the incubator. For the analysis for the speed of the specimen-processing, TAT was investigated with the results in a certain time. Result: The correlation coefficients (R2) between the Gamma Pro and RIA-mat 280 showed a good correlation as T3 (0.98), TSH (0.99), FT4 (0.92). The coefficient of variation (C.V) and accuracy was 0.38 % and 98.3 % at tip 1 and 0.39 % and 98.6 % at tip 2. Carry over showed 0.80 % and 1.04% at tip 1 and tip 2, respectively. These results indicate that tips had no effect on carry over contamination. At the incubator condition, we found that the optimal condition was 1.0mm of diameter at 600RPM in 1.0mm and 1.5mm of at 500RPM or 1.0mm and 1.5 mm of diameter at 600 RPM. the Gamma Pro showed that the number of exam times were increased as maximum 20 times/day comparing to 6 times/day by current automatic equipment. These results also led to the short TAT from 4.20 hour to 2.19 hours in whole processing. Conclusion: The correlation of between the Gamma Pro and RIA-mat 280 was good and has not carry over contamination in tips. The domestic automation equipment (Gamma Pro) decreases the TAT in whole test comparing to RIA-280. These results demonstrate that Gamma Pro has a good efficiency, reliability and practical usefulness, which may contribute to the excellent skill to process the large scale specimens.

  • PDF

Design of a Seismic Isolation Table for both indoor and outdoor Electrical Communication Equipment (전기통신설비를 위한 옥내외 겸용 면진테이블 설계)

  • Lee, Chun-Se;Ahn, Hyeong-Joon;Lee, Taek-Won;Son, In-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.472-472
    • /
    • 2009
  • The safety of cultural properties, medical treatment and electrical communication equipments in a building was hardly considered against the earthquake induced vibration, while the integrity of the building structure has been taken into account through the resistant earthquake design. This paper presents design of a seismic isolation table for both indoor and outdoor electrical communication equipment. First of all, artificial earthquake waves compatible with floor and ground response spectra for electrical communication equipments are generated using previously recorded seismic waves. Two kinds of one-degree-of-freedom seismic isolation table systems: spring-linear damper and spring-friction damper systems are considered and their responses to artificial earthquake waves are simulated. Design parameter study for two seismic isolation tables are performed through simulations and a seismic isolation table for both indoor and outdoor electrical communication equipment is designed considering the simulation results.

  • PDF

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer))

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.901_902
    • /
    • 2009
  • This paper describes the development of a three-phase Line-Interactive DVR(Dynamic Voltage Restorer), which is applied to Hybrid detection method and super-capacitor. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental will be work with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

Actual status of infection control by the dental hygienist in Korea (일개지역 치과위생사의 감염관리 실태에 관한 연구)

  • Yun, Kyoung-Ok
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.3
    • /
    • pp.369-376
    • /
    • 2013
  • Objectives : The objectives of this study is to investigate the handwashing and use of personal protection equipment in dental hygienists and provide the basic data for dental infection control guideline. Methods : A questionnaire survey was performed in the dental hygienists who participated in the continuing education by the Daejeon City Commission in October 2012. The collected data were analyzed using PASW 18.0. Results : Handwashing was well practiced in group working for 3 to 5 years of employment. Those who took the infection cnotrol training used liquid soap, paper towel, dental mask, protective goggles, face shield, and gloves. Conclusions : Infection control is the most important practice in dental hygienists. So it is necessary to emphasize the inportnace of personal protection equipment including medical gloves, dental mask, and goggles.