The effective quality assurance for image guided device using the AMC G-Box (AMC G-Box를 이용한 영상유도장치의 효율적인 정도관리)

  • Kim, Chong Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.199-206
    • /
    • 2014
  • Purpose : According to the rapid increase recently in image-guided radiation therapy, It is necessary to control of the image guidance system completely. In particular for the main subject to the accuracy of image guided radiation therapy device to be done essentially the quality assurance. We made efficient phantom in AMC for the management of the accurate and efficient. Materials and Methods : By setting up of five very important as a quality assurance inventory of the Image guidance system, we made (AMC G-Box) phantom for quality assurance efficient and accurate. Quality assurance list were the Iso-center align, the real measurement, the center align of four direction, the accuracy of table movement and the reproducibility of Hounsfield Unit. The rectangular phantom; acrylic with a thickness of 1 cm to $10cm{\time}10cm{\time}10cm$ was inserted the three materials with different densities respectively for measure the CBCT HU. The phantom was to perform a check of consistency centered by creating a marker that indicates the position of the center fixed. By performing the quality assurance using the phantom of existing, comparing the resulting value to the different resulting value using the AMC G-Box, experiment was analyzed time and problems. Therapy equipment was used Varian device. It was measured twice at 1-week intervals. Results : When implemented quality assurance of an image guidance system using AMC G-Box and a phantom existing has been completed, the quality assurance result is similar in $0.2mm{\pm}0.1$. In the case of the conventional method, it was 45 minutes at 30 minutes. When using AMC G-Box, it takes 20 minutes 15 minutes, and declined to 50% of the time. Conclusion : The consistency and accurate of image guidance system tend to decline using device. Therefore, We need to perform thoroughly on the quality assurance related. It needs to be checked daily to consistency check especially. When using the AMC G-Box, It is possible to enhance the accuracy of the patient care and equipment efficiently performing accurate quality assurance.

The Survey of Dentists: Updated Knowledge about Basic Life support and Experiences of Dental Emergency in Korea

  • Cho, Kyoung-Ah;Kim, Hyuk;Lee, Brian Seonghwa;Kwon, Woon-Yong;Kim, Mi-Seon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.1
    • /
    • pp.17-27
    • /
    • 2014
  • Background: Various medical emergency situations can occur during dental practices. Cardiac arrest is known to comprise approximately 1% of emergency situation. Thus, it is necessary for dentists to be able to perform cardiopulmonary resuscitation (CPR) to increase the chance of saving patient's life in emergency situation. In this paper, we conducted a survey study to evaluate to what extent dentists actually understood CPR practice and if they had experience in handling emergency situations in practice. Method: The survey was done for members of the Korean Dental Society of Anesthesiology (KDSA), who had great interest in CPR and for whom survey-by-mail was convenient. We had selected 472 members of the KDSA with a dental license and whose office address and contact information were appropriate, and sent them a survey questionnaire by mail asking about the degree of their CPR understanding and if they had experience of handling emergency questions before. Statistical analyses -frequency analysis, chi-square test, ANOVA, and so on- were performed by use of IBM SPSS Statistics 19 for each question. Result: Among 472 people, 181 responded (38.4% response rate). Among the respondents were 134 male and 47 female dentists. Their average age was $40.4{\pm}8.4$. In terms of practice type, there were 123 private practitioners (68.0%), 20 professors (11.0%), 16 dentists-in-service (8.8%), 13 residents (specialist training) (7.2%) and 9 military doctors (5%). There were 125 dentists (69.1%) who were specialists or receiving training to be specialist, most of whom were oral surgeon (57, 31.5%) and pediatric dentists (56, 30.9%). There were 153 people (85.0%) who received CPR training before, and 65 of them (35.9%) were receiving regular training. When asked about the ratio of chest pressure vs mouth-to-mouth respiration when conducting CPR, 107 people (59.1%) answered 30:2. However, only 27.1% of them answered correctly for a question regarding CPR stages, C(Circulation)- A(Airway)- B(Breathing)- D(Defibrillation), which was defined in revised 2010 CPR practice guideline. Dentists who had experience of handling emergency situations in their practice were 119 (65.6%). The kinds of emergency situations they experienced were syncope (68, 37.6%), allergic reactions to local anesthetic (44, 24.3%), hyperventilation (43, 23.8%), seizure (25, 13.8%), hypoglycemia (15, 8.3%), breathing difficulty (14, 7.8%), cardiac arrest (11, 6.1%), airway obstruction (6, 3.3%), intake of foreign material and angina pectoris (4, 2.2%), in order of frequency. Most respondents answered that they handled the situation appropriately under the given emergency situation. In terms of emergency equipment they had blood pressure device (70.2%), pulse oximetry (69.6%), Bag-Valve-Mask (56.9%), emergency medicine (41.4%), intubation kit (29.8%), automated external defibrillator (23.2%), suction kit (19.3%) and 12 people (6.6%) did not have any equipment. In terms of confidence in handling emergency situation, with 1-10 point scale, their response was $4.86{\pm}2.41$ points. The average point of those who received regular training was $5.92{\pm}2.20$, while those who did not was $4.29{\pm}2.29$ points (P<0.001) Conclusion: The result showed they had good knowledge of CPR but the information they had was not up-to-date. Also, they were frequently exposed to the risk of emergency situation during their dental practice but the level of confidence in handling the emergency situation was intermediate. Therefore, regular training of CPR to prepare them for handling emergency situation is deemed necessary.

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

Adequacy of Source to Image Receptor Distance with Chest Postero-Anterior Projection in Digital Radiology System (디지털방사선 환경에서 흉부 후-전 방향 검사 시 초점과 영상수용체간 거리의 적절성)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;You, In-Gyu;Jung, Hong-Ryang;Lee, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.135-142
    • /
    • 2016
  • The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7~3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6~2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6~8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6~8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

Norm-referenced criteria for strength of the elbow joint for the korean high school baseball players using the isokinetic equipment: (Focusing on seoul and gyeonggi-do) (등속성 장비를 이용하여 한국고교야구선수 주관절 근력 평가기준치 설정: (서울 및 경기도 중심으로))

  • Kim, Su-Hyun;Lee, Jin-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.442-447
    • /
    • 2017
  • The purpose of this study was to establish norm-referenced criteria for the isokinetic strength of the elbow joint in Korean high school baseball players. Two hundred and one high school baseball players participated in this study, none of whom had any medical problem with their upper limbs. The elbow flexion/extension test was conducted four times at a speed of $60^{\circ}/sec$. The HUMAC NORM (CSMI, USA) system was used to obtain the values of the peak torque and peak torque per body weight. The results were presented as norm-referenced criterion valuesusing the 5-point scale of Cajori which consists of five stages (6.06%, 24.17%, 38.30%, 24.17%, and 6.06%). In the results of this study, the peak torques of the elbow (flexor and extensor?) at an angular velocity of $60^{\circ}/sec$ were $37.88{\pm}8.14Nm$ and $44.59{\pm}11.79Nm$, and the peak torque per body weight of the elbow (flexor and extensor?) were $50.06{\pm}8.66Nm$ and $58.28{\pm}12.84Nm$, respectively. The reference values of the peak torque and peak torque per body weight of the elbow flexor and extensor were setat an angular velocity of $60^{\circ}/sec$. On the basis of the results analyzed in this study, the following conclusions were drawn. There is a lack of proper studies on the elbow joint strength, even though the most common injury in baseball players occurs in the elbow joint. Therefore, we need to establish a standard muscle strength in order to prevent elbow joint injuries and improve their performance. The criteria for the peak torque and peak torque per body weight established here in will provide useful information for high school baseball players, baseball coaches, athletic trainers and sports injury rehabilitation specialists in injury recovery and return to rehabilitation, which can beutilized as objective clinical assessment data.

Measurement of Environmental Radiation Using Medical Scintillation Detector in Well Counter System (의료용 우물형 섬광계수기를 이용한 환경 방사선 측정)

  • Lyu, Kwang Yeul;Park, Yeon-joon;Kim, Min-jeong;Ham, Eun-hye;Yoon, Ji-yeol;Kim, Hyun-jin;Min, Jung Hwan;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.337-345
    • /
    • 2015
  • After the Fukushima nuclear accident in 2011, concerns about radiation by people are increasing rapidly. If people could know how much they will be exposed by radiation, it may help them avoiding it and understand what exactly radiation is. By doing this, we were helping to reduce the anxiety of radiation contamination. In this study, we have researched figures of radioactivity with 'Captus-3000 thyroid uptake measurement systems' in well counter detector system. The materials were measured with Briquette, Shiitake, Pollock, Button type battery, Alkaline battery, Topsoil, Asphalt, Gasoline, Milk powder, Pine, Basalt stone, Pencil lead, Wasabi, Coarse salt, Tuna(can) Cigar, Beer, and then we categorized those samples into Land resources, Water resources, Foodstuff and Etc (Beer classified as a water resources has been categorized into Foodstuff). Also, we selected the standard radiation source linear 137Cs to measure the sensitivity of well counter detector. After that, we took cpm(counter per minute) for the well counter detector of thyroid uptake system's sensitivity. Then we compared the results of each material's cpm and converted those results to Bq/kg unit. There were a little limitation with the measurement equipment because it has less sensitivity than other professional equipment like 'High purity germanium radiation detector'. Moreover, We didn't have many choices to decide the materials. As a result, there are macroscopic differences among the rates of material's spectrum. Therefore, it had meaningful results that showed how much each material had emitted radiation. To compare the material's cpm with BKG, we've compounded their spectrums. By doing that, we were able to detect some differences among the spectrums at specific peak section. Lastly, Button type battery, Alkaline Battery, Briquette, Asphalt and Topsoil showed high value. There were classified emitting high radiation Group A and emitted lower radiation Group B. The Group A, alkaline battery showed higher rate of radiation by 7.67 %, and Button type battery was yield 4.65 % higher rate than BKG. Additionally, Asphalt (8.03 %), Topsoil (3.76 %), Briquette (7.46 %) were yield for higher values. Several samples of the daily supplies were yield little higher, but it seems safe to use in daily lives. In the case of the 'Foodstuff', all of the samples were safe and they were under the radiation limits of the Ministry of Food and Drug Safety for Food; thus, we highly recommend this study to you as a reference of common daily routine.

The Average Glandular Dose in Mammography and Quality Control of the Equipment Status (유방촬영검사에서 평균유선선량과 장치의 품질관리 실태)

  • Jung, Hong-Ryang;Hwang, Su-Lyun;Ha, Bon-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.3
    • /
    • pp.111-120
    • /
    • 2011
  • A purpose of study is to develop optimization and radiation dose exposure reference level by measuring actual radiation dose in condition of quality control of mammography equipment for 39 clinics. The result were as follows. First, we measured T-test separating radiology from general clinic. According to the test, mAs was measured at average 78.58 mAs; radiology at 80.16 mAs and general clinic at 77.22 mAs. And, kerma rate was measured at average 7.71 mGy/mR; radiology at 8.94 mGy/mR and general clinic at 6.66 mGy/mR. HVL was measured at average 0.42 mmAl; radiology at 0.40 mmAl and general clinic at 0.43 mmAl. Average glandular dose was measured at average 1.14 mGy; radiology at 1.09 mGy and general clinic at 1.19 mGy. Second, we measured value of mAs, HVL, processing method and so on dividing two groups. And, we compared and analyzed average value measured using T-test. As a result, there was significance level in SID(P<0.05). There was significance level in mAs(P<0.05). Because processor was measured at 1.00 mGy and CR at 1.17 mGy according to the processing method of radiology. Third, according to the correlation analysis, radiology had significance level between average glandular dose and mAs and general clinic had significance level between average glandular dose and SID(P<0.05). Forth, as a result of regression analysis, mAs affected 22.7%t of average glandular dose and SID affected 21.7% of average glandular dose, which had significance level(P<0.05). And, mAs affected 29.0% of average glandular dose in radiology and SID affected 29.1% of average glandular dose in general clinic, which was most influential.

A Study of on the Method to Select Manufacturing Activities Sensitive to Regional Characteristics by Analyzing the Locational Hierarchy (입지계층분석을 활용한 산업단지 유치 업종 결정에 관한 연구)

  • So, Jin-Kwang;Lee, Hyeon-Joo;Kim, Sun-Woo
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.559-568
    • /
    • 2011
  • This study aims at listing up those manufacturing activities sensitive to regional characteristics by analyzing locational hierarchy designed on the urban rank-size rule. This locational hierarchy by manufacturing activities is expected to provide a ground for the proper supply of an industrial complex. The analysis of the locational hierarchy by manufacturing activities can work as a method of observing the characteristics of the distribution of location for each economic activity by analyzing the trend in the change of manufacturing location. Consequently, it can be used to determine the appropriate manufacturing activities for the industrial complex of a particular region. Here, the locational hierarchy is analyzed depending on the base of the basic local government such as Gun(district level) and Si(city level), and manufacturing activities are categorized by Korea Standard Industry Code. Those activities demonstrating growth pattern are Manufacture of Electronic Equipment(KSIC 26), Manufacture of Medical Precision Optical Instruments Watch(KSIC 27), Manufacture of Motor Vehicles (KSIC 30, 31), etc. With proper infrastructures, these activities can be located everywhere. Those sectors on the decline pattern in the locational hierarchy can be summarized as Manufacture of Tobacco Products(KSIC 12), Manufacture of wearing apparel Fur Articles(KSIC 14), etc. Those sectors scattered widely in the locational hierarchy are Manufacture of Food Products(KSIC 10), Manufacture of Coke Petroleum Products(KSIC 19), Manufacture of Chemical Products(KSIC 20), Manufacture of Electronic Equipment(KSIC 26). These particular manufacturing activities can be operated in those regions in a sufficient supply of unskilled workers regardless of proper infrastructures. Those activities that have a tendency to reconcentrate on larger cities are Manufacture of Textiles(KSIC 13), Manufacture of Wearing Apparel Clothing Fur Articles(KSIC 14), Manufacture of Other Transport Equiptmen(KSIC 31). In most cases, these sectors tend to favor their existing agglomerated areas and concentrate around large cities. Therefore, it is inefficient to promote these sectors in small or medium-sized cities or underdeveloped regions. The establishment of developmental strategies of an industrial complex can gain greater competitiveness by observing such characteristics of the locational hierarchy.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.