• 제목/요약/키워드: Medical charge

검색결과 519건 처리시간 0.031초

치과기공사의 업무스트레스에 대한 연구 (A Study on Job Stress of Dental Technician)

  • 이덕수;곽동주;남상용
    • 대한치과기공학회지
    • /
    • 제24권1호
    • /
    • pp.51-63
    • /
    • 2002
  • The purpose of this study was to be of use for getting rid of job stress from dental technicians, by examining how much they were stressed out at work place as one of the professional medical personnels. The subjects in this study were 255 selected dental technicians who were working in the region of Taegu. The one-on-one interview was conducted from March 1 to 30, 2001, with structured questionnaire. The questionnaire sued in this study included 19 question items about the general characteristics and 29 items regarding job stress. The job stress was categorized into seven subareas based on earlier studies and considering the job situations of dental technicians: heavy workload, job conflicts, improper treatment, role and job knowledge, human relations, physical environment and personal matters. The job stress extent was measured on five-point Likert scale that is widely used in social science: one point for no stress, two for little stress, three for so-so, four for a little stress, and five for severe stress. Therefore, a higher point means a severer job stress. The reliability of the questionnaire turned out very good with Cronbach a = 0.9272. The findings of this study were as follows: 1. The general characteristics of the dental technicians investigated could be described as below: (1) By gender, 80.4% of the dental technicians were male, and 50.2%, the largest percentage, were in their 20s, followed by those in their 30s, those in their 40s, and those in their 50s in the order named. (2) The most common work place was dental technician shop(92.5%), followed by dental technology room in dental hospital or clinic and in general hospital in the order named. The primary duties were coating materials work(30.6%), followed by sculpture, grinding, partial and full denture and orthodontics in the order named. 2. The most larges (1) The most largest motivation to be a dental technician was its being a professional(33.7%), followed by the advice from others, their own aptitude, and good economic treatment in the order named. 3. Their job stress could be explained as below: (1) Their collective job stress average was 3.96$^{\circ}{\ae}$0.50 on the basis of 5 point, which showed that they were exposed to a fairly severe job stress. (2) By area, they were most stressed out from heavy workload (4.12), and they also were severely stressed from role and job knowledge(4.02) and personal matters(4.00). (3) By situation, they were most stressed when the disagreement of prosthesis that results from a specific error is unconditionally attributed to them(4.43). And they were also stressed a lot when their workload increases due to the rework(4.38), when a dentist asks something difficult for them to resolve(4.20), when heavy workload makes their working hours irregular and it's impossible to lead a personal life or have leisure time(4.16), and when they are o work for an excessively short time(4.16). This fact indicated that most of the dental technicians were exposed to a lot of stress in conjunction with job performance. 4. The main duties they took charge of didn't make any significant difference to their job stress, but yielded a significant difference to the extent of job stress in individual areas and the order of the most stressful one. Those who were engaged in grinding were most stressed from their own matters, whereas heavy workload was most stressful for those who were engaged in the other types of works. 5. As a result of seeing if their personal characteristics yielded any differences to job stress, the personal characteristics that made their job stress vary significantly were working hours, motivation of being a dental technician, job satisfaction and willingness to continue doing dental technology works. There was a tendency that longer working hours led to severer job stress, and those who chose to be a dental technician according to their own aptitude were less stressed than the others who became a dental technician because of economic reason or advices from others. And the people who were satisfied with their job were exposed to less job stress than the others who weren't, and those who had an intention to keep that job as much as possible were less stressed, compared to the others who hadn't.

  • PDF

물리치료 임상실습 교과내용 개선을 위한 조사연구 (The Survey for Improvement in Clinical Practice Curriculum of Physiotherapy)

  • 장수경
    • 대한물리치료과학회지
    • /
    • 제5권3호
    • /
    • pp.659-674
    • /
    • 1998
  • This Study was to investigate elaborated research themes and direction through specifying the problems of clinical practice education and looking for the direction of improvement. It was in the basis of the viewpoint of the educators that professors and therapists who were the subjects of this study. Perform this study, the 15 colleges' professors and the 55 hospitals' therapists was made up questionnaire, and the data was analysing by Chi-square test and percentage. The results were as follow : ${\cdot}$ In a personal history among the general qualities, professors have little clinical practice history(l-5 years, 53.3%), and therapists have little lecture career(1-5 years, 43.6%, have no 49.0%), ${\cdot}$ The 78.6% subjects were unsatisfied of clinical practice systems. ${\cdot}$ The correlation between clinical history, school career and lecture career and the satisfaction level of clinical practice systems has no(P<.005), ${\cdot}$ The subjects were agreed to that clinical practice curriculum should be changed(67.1%), reinforced(82.9%), and specified(90.0%). ${\cdot}$ The clinical practice credits are 11 points averagely. ${\cdot}$ In the clinical practice curriculum, it made no difference in the practicum of diseases, modality, and the therapeutic techniques between professors and therapists. ${\cdot}$ The 100% professors said that the practicum of the patients' assessment is necessary, and the 63.6% therapists were training for that. ${\cdot}$ The 66.7% professors said that the practicum of the clinical psychology is necessary, and only the 20.0% therapists were training for that. ${\cdot}$ The 93.3% professors said that the practicum of the patients' management is necessary, and the 50.9% therapists were training for that. ${\cdot}$ The 66.7% professors said that the practicum of the medical ethics is necessary, and the 34.5% therapists were training for that. ${\cdot}$ The 46.7% professors said that the practicum of the hospital administration is necessary, but the 54.5% therapists have not training. ${\cdot}$ The 33.3% professors said that the practicum of the pharmacology is necessary, but the 81.8% therapists have not training. ${\cdot}$ The 86.7% professors said that the practicum of the patient's education is necessary, and the 43.6% therapists have training. ${\cdot}$ The 66.7% professors said that the practicum of the prosthesis and brace is necessary, but the 14.5% therapists have not training. ${\cdot}$ The 60.0% professors said that the practicum of the exercise prescription is necessary, but the 25.5% therapists have not training. ${\cdot}$ The 53.5% professors said that the practicum of the emergency treatment is necessary, but the 52.7% therapists have not training. ${\cdot}$ Drawing up the plan about the curriculum of clinical practice, the professors (46.7%) were agreed to national master plan framing by an expert advisor, but the therapists (58.2%) said that the plan that make the most of hospitals' characteristics should be specified. ${\cdot}$ It was found that a clinical special therapists(54.5%) was good as a person in charge of clinical practice education, in that each therapist's own good time (34.5%) was. ${\cdot}$ It made use of the form framing by college(40.0%) as the clinical practice textbook, the form framing by hospital (42.9%) and each therapist(22.9%) as the plan, and the form framing by college (74.3%) as the measurement. ${\cdot}$ The most difficult point in clinical practice education was the lacks of the theory-praciticum linkage(78.2%). ${\cdot}$ It was found that the period of clinical practice was in the second semester-third grade (40.0%) and the desirable period was in the first semester-third grade(50.0%). ${\cdot}$ Professors (53.3%) were agreed that the desirable clinical practice duration was from four months to six months(60.0%), and the therapists (60.0%) were agreed that from one month to three months. ${\cdot}$ This study presented the lacks of rearing the experts, the lacks of cultural education, and the lacks of the theory-clinical practice linkage. There were need to develop the systematic programs, clinical practice textbooks, the measurements and the special hospital for clinical practice. And it was need to reduce the gab between of the hospitals for clinical practice, to cut down the costs. and to improve the labour conditions of leaders. In view of this findings, it takes notice of that both professor and therapist were dissatisfied at the present clinical practice systems. These results point out the problems of clinical practice systems, and do not make expect to us the successive and positive clinical practice. The general, specific and intensive plan about the problems and the direction of improvement that establishing the level of hospital for clinical practice and physiotherapy can be elaborated.

  • PDF

Patterns of Care Study를 위한 2006년 한국 방사선종양학과 전문의들의 전립선암 방사선치료원칙 조사연구 (A Patterns of Care Study of the Various Radiation Therapies for Prostate Cancer among Korean Radiation Oncologists in 2006)

  • 김진희;김재성;하성환;신성수;박원;조재호;서창옥;오영택;신세원;김재철;장지영;남택근;최영민;김일한
    • Radiation Oncology Journal
    • /
    • 제26권2호
    • /
    • pp.96-103
    • /
    • 2008
  • 목적: 한국인의 비뇨기암 중 1990년 말부터 발병률이 빠르게 증가되고 있는 전립선암의 치료에 있어 전국 각 병원의 방사선종양학과에서 시행되고 있는 방사선치료의 현황을 조사, 분석하고 이를 바탕으로 전립선암의 Patterns of care study(PCS) 개발의 기본 자료로 이용하고자 한다. 대상 및 방법: 전국 13개 대학병원의 방사선종양학과 전문의들의 설문조사를 통하여 각 의사들의 전립선암에 대한 치료 현황과 치료원칙을 수집, 분석하였다. 결과: 진단은 초음파유도 조직생검을 적게는 6개에서 12개 부위, 평균 9개 부위에서 얻고 있으며 진단당시의 영상학적 검사는 대부분에서 자기공명영상과 전신골스캔을 사용하고 있다. 방사선치료를 시행할 때 내부고정물과 외부고정물은 각각 61.5%, 76.9%에서 사용하며 방사선치료의 임상표적부위는 병원마다 다양하게 시행하고 있었다. 전골반 방사선치료는 76.9%에서 $45{\sim}50.4$ Gy를, 정낭의 방사선치료는 92.3%에서 시행하고 있으나 총방사선량은 $54{\sim}73.8$ Gy로 다양하였다. 근치적인 방사선치료의 방사선량은 저위험군에서 고위험군으로 갈수록 증가하였으나 병원간의 차이가 $60{\sim}78.5$ Gy로 넓었다. 세기조절 방사선치료를 시행하는 병원은 53.8%로 반 수 이상에서 시행하고 있으며 총방사선량은 70 Gy이상 이었다. 동시추가분할선량법(SIB; simultaneous integrated boost)을 시행하는 병원은 3곳으로 표적부피와 방사선량이 다양하였다. 전립선 전적출술 후 생화학적 재발의 경우 84.6%의 병원에서 방사선치료를 시행하고 있으며 방사선치료 조사야는 전골반와부터 전립선부위까지 다양하며 총방사선량도 다양하였다. 결론: 전국 13개 병원의 전립선암의 방사선 치료현황을 볼 때 계속 증가하는 전립선암에 대한 전국병원의 방사선치료의 patterns of care study가 필요하며 이를 토대로 전립선암 방사선치료의 guideline을 제시할 필요가 있겠다.

봉독의 주요성분인 Melittin과 MCDP이 비만세포주에서 유전자 발현에 미치는 영향에 대한 microarray 분석 (cDNA microarray gene expression profiling of melittin and mast cell degranulation peptide in human mast cell strain)

  • 소재진;우현수;김창환
    • Journal of Acupuncture Research
    • /
    • 제22권3호
    • /
    • pp.37-51
    • /
    • 2005
  • 비만세포는 염증 및 알레르기 반응과 관련하여 우리 몸에서 주요한 작용을 하는 세포이다. 봉독은 현재까지 진통기전에 관련된 모델로 연구가 진행되어 왔으나, 최근에는 항염증이나 항알러지반응 둥에서 면역세포와 관련 한 연구가 진행 중에 있다. 본 연구는 봉독의 주요성분인 melittin과 MCD Peptide가 비만세포주에서의 유전자 발현에 미치는 영향을 연구함으로써 향후 유전자 언구에 관련한 기초를 제시하고자 하였다. 본 연구에서는 사람의 비만세포주를 이용하여, 세포독성 실험을 거쳐서 얻은 유효농도에서 각각 melittin과 MCD Peptide를 처치하고, 이때 변화하는 유전자의 발현양상을 microarray분석기법을 통하여 정보를 얻었다. 실험적 통계에 의하여 global M이 1 또는 -1 이상인 것을 유의한 것으로 보았을 때, melittin에서는 모두 7개 의 유전자가 항진되고, 8개의 유전자가 어제되었다. MCDP에서는 7개의 유전자가 항진되고 17개의 유전자가 억제되었다. 이들 유전자들이 주로 관련하는 체내의 작용은 세포내에서 단백결합, lymphocyte 기능의 활성화, macrophage 항원관련 및 세포핵의 수용체, GABA A receptor 관련물질, cAMP 반응요소와 연관된 단백질, 보체계 8번 및 B-cell 관련물질, 다낭성 신질환에 관련된 단백물질, 염증관련물질, 혈액응고에 영향을 주는 단백물질등과 연관이 되었다. 이러한 분석결과를 통하여 동복에서의 주요약리작용을 담당하는 melittin과 MCD peptide의 작용기전을 밝히는데 보다 유용한 자료를 얻을 수 있었으며, 향후에 봉독의 주요성분 및 전체봉 독액이 항알레르기반응이나 항염증작용에 미치는 영향에 대한 심도있는 연구가 필요할 것으로 사료된다.

  • PDF

식용식물자원으로부터 활성물질의 탐색-IX. 흰씀바귀(Ixeris dentata forma albiflora)뿌리에서 Sesquiterpene Lactone 화합물의 분리 및 구조 동정; ACAT, DGAT 및 FPTase 효소 활성의 저해 (Screening of Biologically Active Compound from Edible Plant Sources-IX. Isolation and Identification of Sesquiterpene Lactons Isolated from the Root of Ixeris dentata forma albiflora; Inhibition Effects on ACAT, DGAT and FPTase Activity)

  • 방면호;장태오;송명종;김동현;권병목;김영국;이현선;정인식;김대근;김성훈;박미현;백남인
    • Applied Biological Chemistry
    • /
    • 제47권2호
    • /
    • pp.251-257
    • /
    • 2004
  • 식용식물자원으로부터 활성소재를 찾기 위하여 흰씀바귀 뿌리를 80% MeOH로 추출하고, 얻어진 추출물을 EtOAc, n-BuOH및 $H_2O$로 용매 분획하였다. EtOAc와 n-BuOH 분획에 대하여 column chromatography를 반복하여 4종의 화합물을 분리하였다. 각각에 대하여 2D-NMR을 포함한 스펙트럼 데이터의 해석과 문헌 자료를 조사하여 zaluzanin C (1), $9{\alpha}-hydroxyguaian-4(l5),10(14),11(13)-triene-6,12-olide$ (2), $3{\beta}-O-{\beta}-D-glucopyranosyl-8{\beta}-hydroxyguaian-4(15),\;10(14 )-diene-6,12-olide$ (3), $3-O-{\beta}- D-glucopyranosyl-8{\beta}hydroxyguaian-10(14)-ene-6,12-olide$ (4)로 구조를 결정하였다. 이들 화합물에 대하여 ACAT(Acyl-CoA: cholesterol acyltransferase), DGAT (diacylglycerol acyltransferase) 및 FPTase(farnesyl-protein transferase)의 활성에 미치는 억제효과를 측정하였다. Compound 1과 Compound 2는 DGAT에 대한 활성억제효과에 있어서 $IC_{50}$ 값이 각각 0.13 mM, 0.10 mM로 나타났고, FPTase에 대하여는 각각 0.15 mM, 0.18 mM로 나타났으며, ACAT에 대하여는 약한 억제 활성을 나타냈다. 따라서 흰씀바귀는 항암 및 항고혈압의 소재 개발에 있어서 유용한 자원으로 활용될 수 있을 것이다.

원예치료정원의 성능개선을 위한 평가지표 개발 (A Development of Evaluation Indicators for Performance Improvement of Horticultural Therapy Garden)

  • 안제준;박율진
    • 한국전통조경학회지
    • /
    • 제36권4호
    • /
    • pp.113-123
    • /
    • 2018
  • 본 연구는 치료적 목적의 달성을 위해 훈련받은 치료사(Horticultural Therapist)가 실시하는 원예활동에 대상자가 참여하는 치료(Therapy)의 공간으로서 '원예치료정원의 성능개선을 위한 평가지표 개발'에 관한 연구로서 원예치료는 대상자의 치료를 위한 '의학모형'이며 원예치료정원은 대상자와 원예치료사의 활동을 기능적이고 효율적으로 지원하는 특성화된 공간임을 기본 전제로 설정하였다. 연구의 수행을 위해 의도적 표집에 의해 모집된 전문가 패널을 대상으로 3차례의 델파이(Delphi)기법과 AHP기법을 수행하였으며, 이를 통해 원예치료정원의 성능개선을 위한 평가지표를 도출하였고, 각 평가지표들을 유형화, 계층화하여 평가항목의 우선순위를 파악하였다. 본 연구를 통한 결과는 다음과 같다. 첫째, 원예치료 관련 업무를 수행하는 공무원과 원예치료사를 대상으로 본 연구의 타당성을 확보하기 위한 전문가 설문을 실시하였으며, 분석결과 관련 공무원 75.2%, 원예치료사 87.8%로 두 직군 모두 원예치료정원에 대한 인식이 높았으며 원예치료를 실시함에 있어서 치료정원의 활용이 필요하다는 의견에 동의하는 것으로 나타났다. 둘째, 원예치료정원 성능평가를 위한 가중치가 적용된 평가지표 개발을 위해 총 3회에 걸쳐 델파이 조사를 실시하였다. 이후 두차례에 걸친 델파이 조사를 통해 타당도 및 신뢰도 분석 결과, 총 34개의 원예치료정원 성능개선을 위한 평가요소가 도출되었다. 셋째, 가중치가 적용된 원예치료정원의 성능개선을 위한 평가지표 개발을 위해 계층분석기법을 적용, 각 지표별 상대적 중요도 및 가중치를 분석한 결과 상위요인에서는 '자연과 인간의 상호작용'이 가장 중요한 요인으로 나타났으며, 다음으로는 '프로그램의 계획과 활용', '사회적 상호작용', '지속가능한 환경', '보편적 디자인'의 순으로 나타났다. 넷째, 전문가를 대상으로 원예치료정원 성능평가를 위한 가중치가 적용된 평가지표 개발을 위하여 종합가중치를 활용하였다. 평가지표의 가중치 적용은 평가점수에 AHP를 이용한 종합가중치를 곱하여 산출하는 것이 일반적이며 이러한 과정을 통해 평가지표들 간의 상대적인 우선순위를 토대로 가중치와 변환점수를 분석하여, '원예치료정원의 성능개선을 위한 평가지표 및 평가점수표'를 최종 작성하였다. 가중치가 적용된 평가표를 활용하여 기존에 조성된 원예치료정원의 효율성 증대를 위한 개선점을 도출할 경우, 전문가의 의견에 따른 항목별 중요도가 반영되어 있으므로 사항별 중요도를 판단하여 우선순위를 선정하여 개선할 수 있으며, 원예치료정원의 신규 조성 시에도 계획단계에서 원예치료 활동의 효율성 증대를 위한 방안으로 주요 지표를 미리 파악함으로서 가이드라인이 설정이나 기타 효율성 증대를 위한 방안을 제안하는데 도움이 될 것으로 판단된다.

"미군의 인삼 복용?" : 20세기 말 인삼의 미국 식이보충제 시장 편입과 미군 매뉴얼 ("The U.S. military uses ginseng?": The official entrance of ginseng to the U.S. dietary supplement market and the U. S. military's dietary supplement manual in the late 20th century)

  • 석영달
    • 인삼문화
    • /
    • 제1권
    • /
    • pp.93-109
    • /
    • 2019
  • 이 논문은 미국에서 생산되는 미국삼이 19세기 서구 약전에서 퇴출된 이후, 20세기에 수출 상품으로서 위기를 겪고, 결국은 '식이보충제'로서 미국 사회와 군대 내에 정착하게 되는 과정을 다루고 있다. 이 과정 속에서 먼저 1994년의 <식이보충제 건강 및 교육법>이라는 법령의 제정은 인삼을 비롯한 식물성 식이보충제들이 미국의 시장에 본격적으로 진출할 수 있는 교두보를 마련해줬고, 그 결과 인삼은 과거 약전에서의 퇴출 이후 '식이보충제'로서 <미국 약전 및 국민 처방집>에 다시 등재될 수 있었다. 하지만 이것은 인삼과 기타 식물성 식이보충제들의 완전한 연착륙을 의미하는 것은 아니었다. 식물성 식이보충제들의 무차별적인 확산을 경계한 미국의 의학계에서는 끊임없이 '위험 담론'을 제기하면서 과학적으로 검증되지 않은 식이보충제 활용에 대한 우려를 표했다. 이것은 <식이보충제 건강 및 교육법>의 느슨한 검증 제도로 인한 근본적인 문제뿐만 아니라, 미국의 대중들이 전문 의료인들을 찾기보다는 직접 식물성 식이보충제에 대한 정보를 얻어 그것을 통해 본인의 건강을 돌보고자 하는 새로운 분위기와도 관계되어 있었다. 이런 상황 속에서 '옹호 담론'을 펼치는 식이보충제 제조업자 및 식물 약재 관계자들의 주장은 다소 여유로워 보였다. 소비자들이 '옹호 담론'의 손을 들어주고 있는 상황 속에서 옹호론자들은 식물성 식이보충제들이 오랜 세월 아무런 문제없이 세계적으로 활용되어왔으며, '천연의' 원료로 만들어졌다는 점만 강조하면 되었기 때문이다. 인삼을 비롯한 식물성 식이보충제들이 사회 내의 담론 충돌 속에서도 식품 통제에 엄격한 미군의 식이보충제 매뉴얼에까지 진출할 수 있었던 것은 미국 내의 이러한 분위기에 편승한 것으로 보인다. 본문에서 살펴본 미군의 초창기 식이보충제 매뉴얼에서 인삼은 여러 식물성 식이보충제 가운데 가장 자세하게 다뤄지고 있었다. 물론 그 속에는 사회 내에 존재하는 '안전성에 대한 우려'도 다소 섞여있었지만, 효능에 대한 충실한 과학적인 설명이나 인삼의 미국 사회 내 성행과 영향력에 대한 언급도 분명히 함께 이뤄지고 있다. 이런 점을 고려할 때 '식이보충제로서의 인삼'에 대한 미국 사회의, 그리고 미국 군 내부의 관심은 상당히 높다고 볼 수 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF