• Title/Summary/Keyword: Medical Ultrasound

Search Result 822, Processing Time 0.033 seconds

Survey on Usage of Korean Quantitative Ultrasound for Proposing Quantitative Ultrasound Quality Control Guideline (초음파골밀도측정기 정도관리 방안제시를 위한 한국 초음파골밀도 사용현황 조사)

  • Jeong, Yoon-Ji;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.329-337
    • /
    • 2018
  • This study was investigated quantitative ultrasound (QUS) usage in Korea for the QUS quality control guidelines. A total of 344 questionnaires collected from July 24th to August 25th 2017 were analyzed. Questionnaires were created through user interviews, expert group advice, literature review and field observation. As a result of the general characteristics of quantitative ultrasound holding amounted to 81.98% of clinic and 6.69% of hospitals. The main user was radio-logical technologists as 31.39%. The contact methods of the gel pad (balloon) were the most used at 56.68% and the scan region was 91.9% of calcaneus. The quantitative ultrasound quality control cycle was 67.37% when the abnormality was found in the equipment, and 63.66% when the accuracy control was implemented according to the manual. The phantoms of QUS were 34.30% of the manufacturer's own phantoms. User of QUS had never received education for quality control of quantitative ultrasound as 62.20%. This study was expected to be useful when creating detailed quality control guidelines in the future, as well as guidelines for the quality control of Korea's standard quantitative ultrasound.

Modified Piezoelectric Ceramics for Portable Ultrasonic Medical Probe Application (휴대용 의료 초음파 프로브 적용을 위한 압전체 제조 및 특성)

  • Kang, Dong Heon;Chae, Mi Na;Hong, Se Won
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.8
    • /
    • pp.483-488
    • /
    • 2016
  • Ultrasound imaging by using piezoelectric materials, such as lead zirconium titanate (PZT) has been one of the most preferred modes of imaging in the medical field due to its simple, low cost and non-ionizing radiation in comparison to other imaging techniques. Recently, the market demand for portable ultrasound is becoming larger with applications in developing countries, disaster area, military, and emergency purposes. However, most of ultrasound probes used is bulky and high power consumable, so unsuitable for such applications. In this study, the 3 layered ceramic specimen consisted of 128 pitches of $420{\mu}m$ in width and $450{\mu}m$ in thickness were prepared by using the Ti-rich PZT compositions co-fired at $1,050^{\circ}C$. Their electrical and ultrasound pulse-echo properties were investigated and compared to the single layer specimen. The 3 layered ultrasound probe showed 1.584 V of Vp-p, which is 3.2 times higher than single layered one, implying that it would allow effectively such a portable ultrasound probe system. The result were discussed in terms of higher capacitance, lower impedance and higher dielectric coefficient of the 3 layered ultrasound probe.

Study on Changes in Shape of Denatured Area in Skull-mimicking Materials Using Focused Ultrasound Sonication

  • Min, JeongHwa;Kim, JuYoung;Jung, HyunDu;Kim, JaeYoung;Noh, SiCheol;Choi, HeungHo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.1
    • /
    • pp.28-34
    • /
    • 2014
  • Recently, ultrasound therapy has become a new and effective treatment for many brain diseases. Therefore, skull-mimicking phantoms have been developed to simulate the skull and brain tissue of a human and allow further research into ultrasound therapy. In this study, the suitability of various skull-mimicking materials(HDPE, POM C, Acrylic) for studies of brain-tumor treatments was evaluated using focused ultrasound. The acoustic properties of three synthetic resins were measured. The skull-mimicking materials were then combined with an egg white phantom to observe the differences in the ultrasound beam distortion according to the type of material. High-intensity polyethylene was found to be suitable as a skull-mimicking phantom because it had acoustic properties and a denatured-area shape that was close to those of the skull,. In this study, a skull-mimicking phantom with a multi-layer structure was produced after evaluating several skull-mimicking materials. This made it possible to predict the denaturation in a skull in relation to focused ultrasound. The development of a therapeutic protocol for a range of brain diseases will be useful in the future.

Interactive image segmentation for ultrasound vascular imaging (초음파 혈관 영상의 상호적 영상 분할)

  • Lee, Onseok;Kim, Mingi;Ha, Seunghan
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.4
    • /
    • pp.15-21
    • /
    • 2012
  • Image segmentation for object to extract data from ultrasound acquired is an essential preprocessing step for the effective diagnosis. Various image segmentation methods have been studied. In this study, interactive image segmentation method by graph cut algorithm is proposed to develop a variety of applications of vascular ultrasound imaging and diagnostics. General imaging and vascular ultrasound imaging segmentation by entering constrain condition such as foreground and background. In the future it will be able to develop new ultrasound diagnostics.

Fusion of Global and Adaptive Methods for Contrast Enhancement of Ultrasound Images (초음파 영상의 콘트라스트 향상을 위한 전역적, 적응적 방법의 융합)

  • Yun, Jae-Ho;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.357-358
    • /
    • 2007
  • Contrast enhancement in the field of ultrasound imaging contributes to improve the accuracy of medical diagnosis by enhancing the visibility of ultrasound images. This paper proposes a contrast enhancement method that improves the contrast of ultrasound images both globally and locally by fusing global and adaptive contrast enhancement methods. Experimental results show that our approach yields more competitive results than the existing global and adaptive contrast enhancement methods in enhancing the visibility of ultrasound images.

  • PDF

Optimal examination for traumatic nerve/muscle injuries in earthquake survivors: a retrospective observational study

  • Berkay Yalcinkaya;Busranur Tuten Sag;Mahmud Fazil Aksakal;Pelin Analay;Hasan Ocak;Murat Kara;Bayram Kaymak;Levent Ozcakar
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.120-127
    • /
    • 2024
  • Background: Physiatrists are facing with survivors from disasters in both the acute and chronic phases of muscle and nerve injuries. Similar to many other clinical conditions, neuromusculoskeletal ultrasound can play a key role in the management of such cases (with various muscle/nerve injuries) as well. Accordingly, in this article, a recent single-center experience after the Turkey-Syria earthquake will be rendered. Methods: Ultrasound examinations were performed for various nerve/muscle lesions in 52 earthquake victims referred from different cities. Demographic features, type of injuries, and applied treatment procedures as well as detailed ultrasonographic findings are illustrated. Results: Of the 52 patients, 19 had incomplete peripheral nerve lesions of the brachial plexus (n=4), lumbosacral plexus (n=1), and upper and lower limbs (n=14). Conclusion: The ultrasonographic approach during disaster relief is paramount as regards subacute and chronic phases of rehabilitation. Considering technological advances (e.g., portable machines), the use of on-site ultrasound examination in the (very) early phases of disaster response also needs to be on the agenda of medical personnel.

Efficacy and Safety of Ultrasound-Guided Radiofrequency Ablation for Primary Hyperparathyroidism: A Prospective Study

  • Hui-hui Chai;Yu Zhao;Zeng Zeng;Rui-zhong Ye;Qiao-hong Hu;Hong-feng He;Jung Hwan Baek;Cheng-zhong Peng
    • Korean Journal of Radiology
    • /
    • v.23 no.5
    • /
    • pp.555-565
    • /
    • 2022
  • Objective: To assess the efficacy and safety of ultrasound (US)-guided radiofrequency ablation (RFA) in patients with primary hyperparathyroidism (PHPT). Materials and Methods: This prospective study enrolled 39 participants (14 male, 25 female; mean age, 59.5 ± 15.3 [range, 18-87] years) between September 1, 2018, and January 31, 2021. All participants had parathyroid lesions causing PHPT, proven biochemically and through imaging. The imaging features of the PHPT nodules, including the shape, margin, size, composition, and location, were evaluated before treatment. Serum intact parathyroid hormone, calcium, and phosphorus levels; parathyroid nodule volume; and PHPT-related symptoms were recorded before and after treatment. We calculated the technical success, biochemical cure, and clinical cure rates for these patients. Complications were evaluated during and after the ablation. Results: Complete ablation was achieved in 38 of the 39 nodules in the 39 enrolled participants. All the patients were treated in one session. The technical success rate was 97.4% (38/39). The mean follow-up duration was 13.2 ± 4.6 (range, 6.0-24.9) months. At 6 and 12 months post-RFA, the biochemical cure rates were 82.1% (32/39) and 84.4% (27/32), respectively, and the clinical cure rates were 100% (39/39) and 96.9% (31/32), respectively. Only 2.6% (1/39) of the patients had recurrent PHPT. At 1, 3, 6, and 12 months after technically successful RFA, 44.7% (17/38), 34.3% (12/35), 15.8% (6/38), and 12.5% (4/32) of participants, respectively, had elevated eucalcemic parathyroid hormone levels. Recurrent laryngeal nerve paralysis occurred in 5.1% (2/39) of the patients, who recovered spontaneously within 1-3 months. Conclusion: US-guided RFA was effective and safe for PHPT patients. RFA may be an alternative treatment tool for patients who cannot tolerate or refuse to undergo surgery.

Side lobe free medical ultrasonic imaging with application to assessing side lobe suppression filter

  • Jeong, Mok Kun;Kwon, Sung Jae
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.355-364
    • /
    • 2018
  • When focusing using an ultrasonic transducer array, a main lobe is formed in the focal region of an ultrasound field, but side lobes also arise around the focal region due to the leakage. Since the side lobes cannot be completely eliminated in the focusing process, they are responsible for subsequent ultrasound image quality degradation. To improve ultrasound image quality, a signal processing strategy to reduce side lobes is definitely in demand. To this end, quantitative determination of main and side lobes is necessary. We propose a theoretically and actually error-free method of exactly discriminating and separately computing the main lobe and side lobe parts in ultrasound image by computer simulation. We refer to images constructed using the main and side lobe signals as the main and side lobe images, respectively. Since the main and side lobe images exactly represent their main and side lobe components, respectively, they can be used to evaluate ultrasound image quality. Defining the average brightness of the main and side lobe images, the conventional to side lobe image ratio, and the main to side lobe image ratio as image quality metrics, we can evaluate image characteristics in speckle images. The proposed method is also applied in assessing the performance of side lobe suppression filtering. We show that the proposed method may greatly aid in the evaluation of medical ultrasonic images using computer simulations, albeit lacking the use of actual experimental data.

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Ultrasound-Guided Placement of Tunneled Hemodialysis Catheters (초음파 유도하 터널식 혈액투석용 도관 삽입술)

  • Lee Hee Bong;Jang Kuhn Jo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.157-174
    • /
    • 2001
  • Ⅰ. Purpose : To evaluate the usefulness of ultrasound-guided, radiologic placement of tunneled hemodialysis catheters via internal jugular vein(IJV). Ⅱ. Materials and Methods : In 32 patients(31 chronic renal failure, 1 acute renal failure), We performed

  • PDF