• Title/Summary/Keyword: Medical Polymers

Search Result 103, Processing Time 0.02 seconds

Short-Chain-Length Polyhydroxyalkanoates: Synthesis in Metabolically Engineered Escherichia coli and Medical Applications

  • PARK, SI-JAE;CHOI, JONG-IL;LEE, SANG-YUP
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.1
    • /
    • pp.206-215
    • /
    • 2005
  • Polyhydroxyalkanoates (PHAs) are homo or hetero polyesters of (R)-hydroxyalkanoates accumulated in various microorganisms under growth-limiting condition in the presence of excess carbon source. They have been suggested as biodegradable substitutes for chemically synthesized polymers. Recombinant Escherichia coli is one of the promising host strains for the economical production of PHAs, and has been extensively investigated for the process development. The heterologous PHA biosynthetic pathways have been established through the metabolic engineering and inherent metabolic pathways of E. coli have been redirected to supply PHA precursors. Fermentation strategies for cultivating these recombinant E. coli strains have also been developed for the efficient production of PHAs. Nowadays, short-chain-length (SCL) PHAs are being re-invited due to its improved mechanical properties and possible applications in the biomedical area. In this article, recent advances in the development of metabolically engineered E. coli strains for the enhanced production of SCL-PHAs are reviewed. Also, medical applications of SCL-PHAs are discussed.

The Effect of Leaflet Elasticity on the Hydrodynamic Performance of Trileaflet Prosthetic Valves (삼엽인공판막 leaflet 탄성도가 수력학적 성능에 미치는 영향)

  • Seo, J.C.;Rhee, K.H.;Lee, S.H.;Ahn, H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.109-112
    • /
    • 1997
  • The Hydrodynamic performance of the trileaflet polymer prosthetic valves depends on the design of the leaflet and the physical properties of the leaflet membrane. In order to study the effect of leaflet membrane elasticity on the hemodynamic performance of trileaflet prosthetic valve, leaflet membranes are manufactured using two different polymers - Biospan and Tecoflex SG-93A. The hemodynamic performance parameters are measured under steady and physiological pulsatile flow, and compared with monoleaflet polymer valve(floating valve) and bileaflet mechanical valve(St. Jude Medical valve). Well designed trileaflet valve shows the lowest mean pressure drop among the tested valves. The trileaflet valves with Biospan membrane show lower pressure drop and back low comparing to those with Tecoflex membrane. More elastic membrane may provide wide opening area during systole and close membrane ree edge contact during diastole. Durability of trileaflet valves are also tested in vitro. Trileaflet valves with non-uniform membrane thickness ail within 17 days because of stress concentration. Trileaflet polymer valves with uniform membrane thickness perform well over 55 days without failure.

  • PDF

Disposable Solid-State pH Sensor Using Nanoporous Platinum and Copolyelectrolytic Junction

  • Noh, Jong-Min;Park, Se-Jin;Kim, Hee-Chan;Chung, Taek-Dong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.11
    • /
    • pp.3128-3132
    • /
    • 2010
  • A disposable solid-state pH sensor was realized by utilizing two nanoporous Pt (npPt) electrodes and a copolyelectrolytic junction. One nanoporous Pt electrode was to measure the pH as an indicating electrode (pH-IE) and the other assembled with copolyelectrolytic junction was to maintain constant open circuit potential ($E_{oc}$) as a solid-state reference electrode (SSRE). The copolyelectrolytic junction was composed of cationic and anionic polymers immobilized by photo-polymerization of N,N'-methylenebisacrylamide, making buffered electrolytic environment on the SSRE. It was expected to make. The nanoporous Pt surrounded by a constant pH excellently worked as a solid state reference electrode so as to stabilize the system within 30 s and retain the electrochemical environment regardless of unknown sample solutions. Combination between the SSRE and the pH-IE commonly based on nanoporous Pt yielded a complete solid-state pH sensor that requires no internal filling solution. The solid state pH sensing chip is simple and easy to fabricate so that it could be practically used for disposable purposes. Moreover, the solid-state pH sensor successfully functions in calibration-free mode in a variety of buffers and surfactant samples.

Cytotoxicity(MTT) evaluation of dental instruments made of polymers (치과용 폴리머 기구의 세포독성(MTT) 평가)

  • Choi, Eun-Mi
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.8
    • /
    • pp.187-195
    • /
    • 2021
  • In order to assess the cell toxicity of 10 instruments made of polymers, the MTT assay which utilizes the L-929 cell was selected. Specimens were eluted at a temperature of 37℃ for 24 hours at a rate of 4g per 20mL, RPMI 1640, and then was positively and negatively contrasted with a control test solution, in accordance with the Notification No. 2020-12 Protocols of Medical Apparatus Biological Safety from the Ministry of Drug and Food Safety. As a result of 24 hours of incubation in 37℃, 5% CO2 Incubator and assessment using an ELISA reader, the results of Intraoral camera indiciated a cellular viability of more than 70% at a 50% eluate. But, the Plastic impression tray, 3D printing tweezer, Impression disposable syringe, Dental floss holder, Hand implant scaler, Surgical retractor, Oral scanner tip, Dental mirror, and the Water pick tip all reported a cellular viability of more than 70% at a 100% eluate, which indicates that do not exhibit cytotoxicity, thus allowing it to be used in contact with the mucous membrane of the oral cavity.

Effect of water storage on flexural strength of silorane and methacrylate-based composite resins

  • Panahandeh, Narges;Torabzadeh, Hassan;Naderi, Hani;Sheikh-Al-Eslamian, Seyedeh Mahsa
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.309-315
    • /
    • 2017
  • Objectives: This study assessed the effect of water storage on the flexural strength (FS) of low shrinkage composites. Materials and Methods: A total of 165 bar-shaped specimens ($2{\times}2{\times}25mm$) were fabricated of 2 low shrinkage composites (Filtek P90 [3M ESPE], GC Kalore [GC International]) and a conventional methacrylate-based composite (Filtek Z250 [3M ESPE]). The specimens were subjected to 3-point bending test at 6 time intervals, namely: immediately after curing, at 24 hours, 1 week, 1 month, 6 months, and 1 year following storage in wet and dry conditions. The FS of the specimens were measured by applying compressive load at a crosshead speed of 1.0 mm/min. Data was analyzed using 3-way analysis of variance (ANOVA) and Tukey's test. Results: Three-way ANOVA revealed significant interactions between time, type of composite, and storage condition (p = 0.001). Tukey's multiple comparison test revealed significant reductions in FS of all composites after 6 months and 1 year of storage in distilled water compared to dry condition. Conclusions: Filtek P90 showed the highest and GC Kalore showed the lowest FS after 1 year storage in distilled water. The immediate high strength of Filtek Z250 significantly decreased at 1 year and its final value was lower than that of Filtek P90.

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.

Enzymatic Synthesis of Sorbitan Methacrylate: Effect of Acyl donor and Molar ratio

  • Lee, Hye-Jin;Jeong, Gwi-Taek;Lee, Kyoung-Min;Ryu, Hwa-Won;Kim, Do-Man;Park, Don-Hee;Kim, Hae-Sung
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.296-299
    • /
    • 2005
  • Sugar polymers have been considered as biomaterial. Biomaterials are widely utilized for a medical applications in direct contact with living tissue Clearly, biomaterials must be carefully and microscopically fabricated for optimal acceptance within the living organism in both functional and structural senses. In this study, the enzymatic synthesis of sorbitan methacrylate from 1,4-sorbitan via the manipulation of an immobilized biocatalyst (Novozym 435) and acryl donors (methacrylic acid and vinyl methacrylate) was evaluated.

  • PDF

The Practical Application of Aqueous Two-Phase Processes for the Recovery of Biological Products

  • Rito-Palomares, Marco
    • Journal of Microbiology and Biotechnology
    • /
    • v.12 no.4
    • /
    • pp.535-543
    • /
    • 2002
  • Although the generic implementation of aqueous two-phase systems (ATPS) processes for the recovery of biological products has been exploited for several years, this has not resulted in a wide adoption of the technique. The main reasons involve the poor understanding of the mechanism governing phase formation and the behavior of solute partitioning in ATPS processes, the cost of phase forming polymers, and the necessary extended time to optimize the technique. In this review paper, some of the practical disadvantages attributed to ATPS are addressed. The practical approach exploited to design ATPS processes, the application to achieve process integration, the extended use for the recovery of high-value products, and the recent development of new low-cost ATPS, are discussed. It is proposed that the trend of the practical application of ATPS processes for the recovery of biological products will involve the purification of new high-value bioparticulate products with medical applications. Such a trend will give new impetus to the technique, and will draw attention from industries needing to develop new, and improve existing, commercial processes.

Synthesis of Block Copdymers Consistin(3 of Poly($\tau$-benzy1 L-glutamate) and Polyoxpropylene and Their Drug Release Behsviours (Poly($\tau$-benzy1 L-glutamate)와 polyoxpropylene으로 된 블록 공중합체의 합성 및 약물방출특성)

  • 강인규;김우식
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.1
    • /
    • pp.55-64
    • /
    • 1992
  • AB -type block copolymers of poly($\tau$-benzyl L-glutamate) (PBLG, a segment) and polyoxypropylene (POP, Bsegment) were synthesized and they were reacted with polyoxypropylene his(6-aminohexyl) (POE) to enhance the hydrophilicity of the poly- mers. The degree of swelling of the POE -crosslinked block copolymers (CPB -2) was higher than that of the block dopolymers (PB). The amount of 5-fluorouracil re- leased from CPB-2 block copolymers was greater than that from the PB block copol- ymers when they were incubated in the same period. These results indicate that the amount of 5-fluorouracil released from the matrices is proportional to the hydrophilicity of the polymers. Observing polymer surfaces by scanning electron mi- croscope, pores (diameter ; $0.5-1.5{\mu}$m) were appeared on the surface of CPB-2

  • PDF

Effect of Water State in Electroactive Chitosan/Poly (Diallyldimethylammonium Chloride) Hydrogels on Bending Behavior at Various pH Conditions (키토산/폴리디아릴디메틸암모늄클로라이드 전기감응성 고분바 하이드로겔의 굽힘 거동에서 물 상태에 따른 영향 분석)

  • Yoon, Seong-Gil;Kim, Seon-Jeong;Kim, In-Young;Kim, Sun-I.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.344-347
    • /
    • 2007
  • A interpenetrating polymer network (IPN) hydrogel, composed of chitosan (CS) and poly(diallydimethylammonium chloride) (PDADMAC) was prepared, which exhibited electrical sensitive behavior. The swelling behavior of the CS/PDADMAC SIPN hydrogel was studied by immersion of the gel into various pH buffer solutions, and their stimuli response in electric fields also investigated. In order to clarify the relationship between the equilibrium swelling ratio and bending behavior of the SIPN hydrogels, the state of water in the SIPN hydrogel was also investigated using differential scanning calorimetry (DSC).