A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System (Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구)

  • Hong, Sun Suk;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.247-253
    • /
    • 2013
  • The purpose is a comparative evaluation in the DR System according to the dosimetry and image quality of the quantitative and objective via Direct digital radiography, Indirect digital radiography, Image intensifier (Charge Coupled Device type) digital radiography. The experimental method used rando phantom and measured the entrance surface dose. And through using the measured entrance surface dose and then using the PCXMC program were evaluated risk due to irradiation and the effective dose. SNR and NPS and CNR were measured and analyzed by using 21cm acryl phantom. Significance of measured value was evaluated by statistics method. Entrance surface dose, major organ dose, effective dose all of them were measured the lowest rated in direct DR when it is on the basis of direct DR dose, high-dose ratio were measured in I.I DR approximately 1.3 times, indirect DR approximately 2.4 times. Risk in accordance with radiation also was measured same as dose ratio. On the conclusion that SNR measurement result based on direct DR SNR measurements, low-SNR ratio were measured in I.I DR approximately 7.25 times, indirect DR approximately 1.48 times. On the conclusion that CNR measurement result based on direct DR CNR measurements, high-dose ratio were measured in I.I type DR approximately 1.16 tims and low-dose ratio were measured in indirect DR approximately 0.87 times. Therefore Direct DR system using a-selenium sensing element to detect x-ray photon is thought effectively at the examination such as infant to sensitive irradiation and the genital gland. Because quality image is built by low dose. Also when it is necessary that image test requiring many diagnosis information, indirect DR system is thought effectively.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Usefulness Evaluation of HRCT using Reconstruction in Chest CT (흉부CT 검사 시 HRCT 영상 재구성의 유용성)

  • Park, Sung-Min;Kim, Keung-Sik;Kang, Seong-Min;Yoo, Beong-Gyu;Lee, Ki-Bae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.17 no.1
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

Association between job types of economically active population and sleep appropriateness among South Koreans (국내 경제활동 인구의 직업유형별 적정수면과의 연관성)

  • Kim, Sun Jung;Kim, Dong Jun;Gim, Eun Na;Yu, Tae Gyu
    • Korea Journal of Hospital Management
    • /
    • v.25 no.3
    • /
    • pp.67-77
    • /
    • 2020
  • Background: As of 2016, average Koreans sleep 7 hours and 42 minutes, the lowest figure among Organization for Economic Cooperation and Development(OECD) countries, and the number of people with sleep disorders reached 561,000. Accordingly, the government has promoted the provision of 'Multiple Sleep Test' to strengthen the diagnosis service for patients with 'sleep disorder' in july 2018. As a result, healthcare costs for patients with sleep disorder is on the rise every year. In this study, we utilized 'Appropriate Sleep' criteria of United States's National Sleep Foundation(NSF) then investigated Korean's sleep pertinence using 「7th National Health and Nutrition Survey for 2016-2018」 by different occupational type, demographic characteristics, socio-economic characteristics, and health behaviors. Methods: We performed descriptive analysis to examine differences of sleep appropriateness by various sample characteristics. Multivariate logistic regression models were used to examine sleep appropriateness by occupational type and other variables. We also analyzed subgroup models to investigate. Results: As a result, a total of 1,948 (18.37%) study subjects experienced in-appropriate sleep. Results of the Multivariate logistic regression analysis revealed that blue color group had a higher odds ratio (OR) for experiencing in-appropriate sleep (OR=1.179). In addition, the odds ratio of experienced in-appropriate sleep among the elderly aged 70 and over was 2.698, and the odds ratio of the overstressed group was 1.299. Furthermore, sub-group analysis showed that blue color job of female(Or=1.334), high school or below(OR=1.404), divorce/death/separation(OR=2.039), 25%ile-50%lie income group(OR=1.411) more likely experienced in-appropriate sleep. Conclusion: Growing sleep disorder patients and related health care costs are expected. Government should apply detailed 'total periodic sleep disorder management policy' including pre-consultation, examination, diagnosis, treatment, post-consultation, self-management especially to vulnerable population that this study found.

A Case of Pulmonary and Retroperitoneal Lymphangioleiomyomatosis (폐와 후복강에 발생한 림프관평활근종증 1예)

  • Kwak, Nam-Ju;Park, Nam-Gu;Kim, He-Young;Choe, Gi-Won;Eom, Je-Ho;Kim, Dong-Un;Cho, Meong-Chan;Yun, Se-Jin;Kim, Sung-Taek;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.4
    • /
    • pp.600-604
    • /
    • 1995
  • Lymphangioleiomyomatosis, a rare disease in women of childbearing age, is the result of benign nodular hypertrophy of the smooth muscle of the lypmhatics and other tissues of the abdomen and thorax. We report a 36-years-old woman with pulmonary and retroperitoneal lymphangioleiomyomat.osis who responded with hormone treatment. She developed vaginal pruritis and a pelvic ultraound was done given her significant past medical history. Ultrasound examination demonstrated a large mass in the right side of her pelvis. Therefore she was admitted to St. Michael's Hospital in Toronto for laparoscopy. Result of cytology was to be consistent with the diagnosis of retroperitoneal lymphangioleiomyomatosis. High resolution CT sacn of the thorax demonstrated multiple small cystic lesions, without associated nodularity compatible with a diagnosis of pulmonary lymphangioleiomyomatosis. She has been taking Provera tablets 100mg po tid since Dec. 15, 1993. We have given her a prescription for Depo provera 500mg IM monthly since she came back to Korea. and made arrangements for regular follow up monthly. We performed chest X-ray, CT of chest(high resolution), abdomen and pelvis, pulmonary function tests and arterial blood gas analysis. Chest X-ray and CT findings showed no significant change since July. 20, 1993.

  • PDF

A Study to Acquire Sharp Images in the Haas(Skull PA Axial Projection) (Haas 촬영법에서 선예한 영상 획득을 위한 연구)

  • Ahn, Jun-Ho;Han, Jae-Bok;Song, Jong-Nam;Kim, In-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.319-325
    • /
    • 2022
  • The Study In order to obtain a sharpness Image from Skull PA axial projection (Haas) in a head axial X-ray Examination, this study changed the posture angle using Skull Phantom and evaluated the image subjectively to 5 radiologists who worked in the Department of Imaging at University Hospital. In the prone position, the head was lowered 4 cm from the back of the head, entered 25° toward the head, and the image evaluation score was high with 20 points, such as the back bone, dorsum sellae projected in the large hole, and posterior clinoid process. In addition, the score significance was verified, and the Cronbach Alpha value was evaluated to have good reliability of 0.789. As a result of calculating the signal-to-noise ratio (SNR) by setting the region of interest (ROI) of the image, it was the highest at 5.957 for 25° incident at the back of the head and 6.430 for 30° incident at the back of the head. As a result of the study, in order to obtain a sharp image of the back of the head bone, dorsum sellae, and posterior clinoid process when shooting in the axial direction after the head, it is filmed by tilting 25° toward the head from 4 cm below the back of the head. In order to obtain a sharp image of rock pyramid symmetry, petrous ridge, sagittal suture, and lambdoid suture, it is thought that it will be helpful for clinical use if you shoot it 8cm down from the back of the head and tilt it 30° toward the head.

Image Quality Analysis According to the of a Linear Transducer (선형 탐촉자에서 관심 시각 영역 변화에 따른 화질 분석)

  • Ji-Na, Park;Jae-Bok, Han;Jong-Gil, Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.975-984
    • /
    • 2022
  • Since a linear transducer has an area of interest equal to the length of the transducer, the area of interest can be expanded using the virtual convex function installed in the device.However, it was thought that the change in the direction of the ultrasonic sound velocity according to the change in the visual area of interest would affect the image quality, so this was objectively confirmed. For this study, image evaluation and SNR·CNR of the phantom for ultrasound quality control were measured. As a result, in the phantom image evaluation, both images were able to identify structures in functional resolution, grayscale, and dynamic range. However, it was confirmed that the standard image was excellent in the reproducibility of the size and shape of the structure. As a result of SNR·CNR evaluation, SNR·CNR of most trapezoidal images was low, except for structures at specific locations. In addition, through the statistical analysis graph, it was further confirmed that the SNR and CNR for each depth decreased as the size of the cystic structure decreased. Through this study, it was confirmed that the use of the function has the advantage of providing a wide visual area of interest, but it has an effect on the image quality. Therefore, when using the virtual convex function, it is judged that the examiner should use it in an appropriate situation and conduct various studies to acquire high-quality images and to improve the understanding and proficiency of the equipment.

A Study on the Analysis of Virus Barrier Materials in a Chest X-ray Laboratory to Respiratory and Droplet Infections Only Patients (호흡기 및 비말감염 환자 전용 흉부 X-선 검사실의 바이러스 차단제 분석에 관한 연구)

  • Kim, Hyeon-Ju;Lee, Jun-Ho;Choi, Kwan-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.169-175
    • /
    • 2022
  • In this study, envisioned a laboratory equipped with virus blocking equipment for chest X-ray examinations of respiratory or droplet-transmitted virus-infected patients, and the material with the least deterioration in X-ray output and image quality among the proven blocking materials that block viruses in the design process. and experimented to find the thickness. As a result, when 1 cm of acrylic was applied, the X-ray output was reduced by only about 3.27 % compared to the absence of the barrier material, the SNR was 40.7 and CNR was 30.9, which was the best. The SSIM index result was analyzed as 0.891, which was analyzed to be implemented as the most similar image compared to the original image. The barrier material applied in the research method was objective in that it used a product approved by the Ministry of Food and Drug Safety. the results of this study are expected to provide useful information when installing X-ray examination facilities for the diagnosis and treatment of respiratory-related virus-infected patients in the future.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

The Predictors of Effectiveness on Urokinase Instillation Therapy into Loculated Pleural Effusion. (소방이 형성된 흉막질환에서 유로키나제 주입치료의 예후인자)

  • Song, Kee-San;Bang, Jei-So;Kwak, Seung-Min;Cho, Chul-Ho;Park, Chan-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.3
    • /
    • pp.621-628
    • /
    • 1997
  • Background : As the pleural inflammation progresses, exudative pleural fluid becomes loculated rapidly with pleural thickening. Complete drainage is important to prevent pleural fibrosis, entrapment and depression of lung function. Intrapleural urokinase instillation therapy has been advocated as a method to facilitate drainage of gelatinous pleural fluid and to allow enzymatic debriment of pleural surface. This study was designed to investigate the predictors of effectiveness of intrapleural urokinase in the treatment of loculated pleural effusion. Method : Thirty-five patients received a single radiographically guided pig-tail catheter ranging in size from 10 to 12 French. Twenty-two patients had tuberculous pleural effusions, and 13 had non-tuberculous postpneumonic empyemas. A total of 240,000 units of urokinase was dissolved in 240 ml of normal saline and the aliquots of 80mL was instilled into the pleural cavity via pig-tail catheter per every 8hr. Effectiveness of intrapleural urokinase instillation therapy was assessed by biochemical markers, ultrasonography, and technical details. A greater than 50% improvement on follow-up chest radiographs was defined as success group. Result : Twenty-seven of 35 (77.1%) patients had successful outcome to urokinase instillation therapy. Duration of symptoms before admission was shorter in success group ($11.8{\pm}6.9day$) than in failure group ($26.62{\pm}16.5day$) (P<0.05). Amount of drained fluid during urokinase therapy was larger in success group ($917.1{\pm}392.7ml$) than in failure group ($613.8{\pm}259.7ml$) (P<0.05). Pleural fluid glucose was higher in success group ($89.7{\pm}35.9mg/dl$) than in failure group ($41.2{\pm}47.1mg/dl$) (P<0.05). Pleural fluid LDH was lower in success group ($878.4{\pm}654.3IU/L$) than in failure group ($2711.1{\pm}973.1IU/L$) (P<0.05). Honeycomb septated pattern on chest ultrasonography was observed in six of eight failure group, but none of success group (P<0.05). Conclusion : Longer duration of symptoms before admission, smaller amount of drained fluid during urokinase therapy, lower glucose value, higher LDH value in pleural fluid examination, and honeycomb septation pattern on chest ultrasonograph were predictors for failure group of intrapleural urokinase instillation therapy.

  • PDF