• Title/Summary/Keyword: Medical Device Management

Search Result 298, Processing Time 0.028 seconds

Transfromation of Percutaneous Extracorporeal Life Support to Paracorporeal Ventricular Assist Device: A Case Report

  • Kim, Chilsung;Cho, Yang Hyun;Sung, Kiick;Yang, Ji-Hyuk
    • Journal of Chest Surgery
    • /
    • v.47 no.4
    • /
    • pp.409-412
    • /
    • 2014
  • Percutaneous extracorporeal life support (P-ECLS) is a useful modality for the management of refractory cardiac or pulmonary failure. However, venoarterial P-ECLS may result in a complication of left ventricular distension. In this case report, we discuss a patient with drug-induced dilated cardiomyopathy managed with venoarterial P-ECLS and a left atrial vent catheter. The venoarterial P-ECLS was modified to a paracorporeal left ventricular assist device (LVAD) by removing the femoral venous cannula. After 28 days of hospitalization, the patient was successfully weaned from the paracorporeal LVAD and discharged home from the hospital.

The Use of Locally Applied Vibration to Minimize Pain during Fractional CO2 Laser Therapy in Living Liver-Donor Scar Management

  • Song, Sinyoung;Choi, Dong Hoon;Oh, Tae Suk
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.570-574
    • /
    • 2016
  • Background Fractional $CO_2$ laser is an effective treatment for scars, but most patients complain about sharp burning pain, even after the application of lidocaine ointment. This study analyzed the impact of a vibrating device to nonpharmacologically reduce the acute pain of laser treatment, in accordance with the gate control theory of pain management. Methods This is a prospective study performed from May 2013 through March 2014. Fifty-three patients (mean age, 26.7 years; range, 16-44 years) who had donated livers for liver transplantation were treated with a fractional $CO_2$ laser (10,600 nm; model $eCO_2$, Lutronic Corp) for their abdomen scars. Laser treatment was applied 4 months after surgery. A commercially available, locally applied vibrating device (model UM-30M, Unix Electronics Co. Ltd.) was used, in an on-and-off pattern, together with the $CO_2$ laser. A visual analogue scale (VAS; 0, no pain; 10, most severe pain) of pain sensation was assessed and statistically analyzed using a paired t-test. Results The average VAS score for pain with the vibrating device was 4.60 and the average VAS score without the vibrating device was 6.11. The average difference between scores was 1.51 (P=0.001). Conclusions A locally applied vibrating device was demonstrated to be effective in reducing pain when treating with a fractional $CO_2$ laser. Vibration treatment could be helpful when treating scars with fractional $CO_2$ laser in pain-sensitive patients, particularly children.

Analysis of Hazard Factors for Domestic General Purpose Ventilator using Usability Assessment (사용적합성 평가를 적용한 국산 범용인공호흡기의 위험요인 분석)

  • Gyeongmin Kwon;Seung hee Kim;You Rim Kim;Won Seuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.45 no.1
    • /
    • pp.10-19
    • /
    • 2024
  • The purpose of this study is to conduct a summative evaluation of the usability of a general-purpose ventilator to determine whether it can be used for its intended purpose in the intended environment by the intended user and to find possible errors in use. The importance of ventilators has increased due to the accelerated aging of the population and the impact of the pandemic. In addition, patients who require ventilators are often in critical condition, so even a small error in use can be fatal. Therefore, it is important to ensure that the ventilator has sufficient stability and can be used satisfactorily without inconvenience to the user. In this study, we conducted a usability test with 17 respiratory nurses with more than 3 years of experience using the ventilator. We analyzed the task success rate, satisfaction, and opinions of the intended users while going through a total of 17 scenarios. Satisfaction was captured through an ASQ questionnaire and subjective opinions were captured through a detailed opinion questionnaire. The results showed a high level of satisfaction with an average score of 6.3 for the use scenarios. Evaluators expressed satisfaction with the overall visibility and versatility of the features, but noted that improvements were needed for calibration tasks with low task success rates. As the calibration method is different from other equipment, it was suggested that specific explanations of the calibration method and the picture that appears when calibrating are needed, and that if relevant training is provided, the equipment can be used without problems. If the usability evaluation is not limited to securing efficiency and satisfaction from the intended users, but also continuously receives feedback from users to prepare for use in emergency environments such as pandemic situations, it will be very helpful to seize opportunities such as emergency authorization in future situations, and ultimately contribute to patient safety by reducing use errors.

Implementation of Service Model to Exchange of Biosignal Information based on HL7 Fast Health Interoperability Resources for the hypertensive management (고혈압 관리를 위한 헬스레벨 7 FHIR 기반 생체정보 교환 서비스 모델 구현)

  • Cho, Hune;Won, Ju Ok;Hong, Hae Sook;Kim, Hwa Sun
    • Journal of Internet Computing and Services
    • /
    • v.15 no.3
    • /
    • pp.21-30
    • /
    • 2014
  • Hypertension is one of the major causes of death in the world as it is related with cardiovascular or cerebrovascular disease, so it is needed to provide continuos management for blood pressure. This study selected Health Level 7 Fast Health Interoperability Resources (HL7 FHIR) as a bio-signal data exchange service model that can provide constant blood pressure management in the rapidly growing mobile health care environment. The HL7 FHIR framework developed communicates with the IEEE 11073-10407 Personal Health Device (PHD) protocol through the bluetooth Health Device Profile (HDP) between the manager (smart phone) and the agent (hemomanometer) and acquires information about blood pressure. According to the test results, it performed its tasks successfully including hypertension patients' blood pressure monitoring, management on measured records, generation of document, or transmission of measured information. Because in the actual, clinical environment, it is possible to transmit measured information through the TCP/IP protocol, it will be needed to conduct constant research on it and vitalize it in the field of mobile health care afterwards.

Results of Culture Test at the Time of Removal of Metal Implants Used for Ankle Fracture Management (족관절 골절 치료에 사용한 금속 내고정물 제거 수술 시 시행한 균 배양 검사의 결과)

  • Chung, Hyung-Jin;Bae, Su-Young;Yu, Jae-Ha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.68-71
    • /
    • 2014
  • Purpose: The purpose of this study is to report the results of culture test at the time of removal of metal devices used for management of ankle fractures and for analysis of contributing factors. Materials and Methods: We reviewed medical records of 132 patients with lower tibia and ankle fracture who had their metal devices removed during the period from January 2010 to February 2014. Patients with clinical signs of infection were excluded. Culture test was performed by taking the granulation tissue around the metal device at the time of removal. We divided the subjects into two groups, culture positive and negative. We then performed a retrospective review of each medical record of multiple factors that might contribute to the culture results, including laboratory results, medical history, material and size of metal device, indwelling period, and whether or not it was open injury. Results: Among 132 cases, six were culture positive. Enterococcus was detected in two cases and the others were Staphylococcus. No significant difference in medical history of patients and laboratory results, including C-reactive protein level, was observed between the culture positive and negative group. Culture positive rate was 5.4% in titanium and 3.9% in stainless steel. In terms of metal size, culture positive rate was 5.1% in small plates, 6.7% in large plates, and culture negative in intramedullary nails. The average indwelling period of metal device was 61.5 weeks in the culture positive group, and 68.6 weeks in the negative group. Nine cases were open fractures and all were in the culture negative group. Conclusion: Whether or not the culture result was positive, there were no meaningful contributing factors. Presence of bacterium on the metal device could not be screened by any laboratory results or other factors.

U-Healthcare Patch Type Wireless Body Temperature Monitoring System (유헬스케어 패치형 무선 체온 모니터링 시스템 구현)

  • Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.

Development of m-Health Application based on Medical Informatics Standards (의료정보 표준에 기반 한 m-Health 어플리케이션 개발)

  • Park, Hyun Sang;Kim, Hwa Sun;Jung, Hyun Jung;Cho, Hune
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.5
    • /
    • pp.640-653
    • /
    • 2014
  • Recently medical consumers pursue high leveled quality of life through active promotion, prevention, management activity of health as the importance of health during home life is emerged to meet the aging society and chronic diseases. In addition, people are directed to the m-Health for managing yourself their health by using smartphone and various personal health devices, if necessary transmits health data to the physician himself. In the previous studies, m-Health Application were developed and applied in the real clinical environment by adopting the medical information standards was rarely conducted. Therefore, in this study, the m-Health application platform was developed. Developed application was communicate with IEEE 11073 standard protocol using the Bluetooth Health Device Profile in personal health device via smart phone to process blood pressure information, and it converted to HL7 V2.6 ORU_R01 message for send to remote medical server. In addition, we tested the interoperability and safety of the developed application for 23 inpatient and 17 outpatient at D University Hospital. As a result, the blood pressure information has been transmitted without error.

Assessing Seasonality of Acute Febrile Respiratory Tract Infections and Medication Use (인플루엔자 등 급성 호흡기계 질환과 의약품 사용의 계절적 상관성 분석)

  • Park, Juhee;Choi, Won Suk;Lee, Hye-Yeong;Kim, Kyoung-Hoon;Kim, Dong-Sook
    • Health Policy and Management
    • /
    • v.28 no.4
    • /
    • pp.402-410
    • /
    • 2018
  • Background: Monitoring appropriate medication categories can provide early warning of certain disease outbreaks. This study aimed to present a methodology for selecting and monitoring medications relevant to the surveillance of acute respiratory tract infections, such as influenza. Methods: To estimate correlations between acute febrile respiratory tract infection and some medication categories, the cross-correlation coefficient (CCC) was used and established. Two databases were used: real-time prescription trend of antivirals, anti-inflammatory drugs, antibiotics using Drug Utilization Review Program between 2012 and 2015 and physicians' number of encounters with acute febrile respiratory tract infections such as influenza outbreaks using the national level health insurance claims data. The seasonality was also evaluated using the CCC. Results: After selecting six candidate diseases that require extensive monitoring, influenza with highly specific medical treatment according to the health insurance claims data and its medications were chosen as final candidates based on a data-driven approach. Antiviral medications and influenza were significantly correlated. Conclusion: An annual correlation was observed between influenza and antiviral medications, anti-inflammatory drugs. Suitable models should be established for syndromic surveillance of influenza.

DB set-up of the Year 2000 date problem for medical device (의료기기 Year2000 문제해결을 위한 데이터베이스 구축방안)

  • Kim, S.H.;Juh, R.H.;Lee, S.D.;Shin, T.S.;Kim, J.S.;Kim, S.H.;Huh, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.104-105
    • /
    • 1998
  • To minimize the Y2K (year 2000) date aware problem of medical devices, we are developing a database that keeps the data such as equipment type, specification, serial number, model number, acquisition date, vendor, manufacturer of the device as well as the names of departments that installed and that is currently responsible for the management of the medical device. The database also keeps the information as to whether the device awares the date, whether it is affected by the Y2K problem or not, how to solve the problem, reference home page address, and so on. The data was collected via internet search of the FDA web site and related of manufacturers homepages. To manage the Y2K problem effectively, the database should be updated regularly to include recent information.

  • PDF

The Development of Assistant Device for the Standing X-ray Views and Its Usability for the Patient Safety (환자의 안전을 위한 입식 X선 촬영 보조기구 개발 및 유용성 평가)

  • Gil, Jong Won;Kim, Yong Gwon
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, We designed and implemented a assistant device for the standing X-ray views which is the one of the clinical X-ray imaging position. To evaluate the usability of the proposed assistant device, We choose 11 clinical patient postures that are used frequently and applied the postures to 5 volunteers. 11 images was taken from a volunteer for the patient postures. And we conducted a survey on safety and clinical usefulness, the 5 volunteers responded to the safety and 5 experts responded to the clinical usefulness. The survey results show that the volunteers feel more safe and the obtained images are very clear and clinically useful. The result for the image quality is 4.69 of 5(best) and safety is 2.84 of 3(best). It will be very profitable to both patients and hospitals by using the proposed assistant device.