• Title/Summary/Keyword: Mechanical performance test

Search Result 2,596, Processing Time 0.036 seconds

Mechanical and Durability Characteristics of Latex Modified Repair Mortar for Agricultural Underwater Concrete Structure (수중에 노출된 농업용 콘크리트 구조물 보수용 라텍스개질 모르타르의 역학적 특성 및 내구성능 평가)

  • Won, Jong-Pil;Lee, Jae-Young;Park, Chan-Gi;Sung, Sang-Kyung;Kim, Wan-Young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.4
    • /
    • pp.35-41
    • /
    • 2007
  • The most agricultural concrete structures for the irrigation and drainage are exposed to the underwater condition at the irrigation period and they take the influence on very severe cold in the winter. Therefore, it is impossible to use repair materials used to the general concrete structures. The research need the development of the repair material for a performance enhance of the agricultural underwater concrete structures. This research evaluated the mechanical and durability performance of the latex modified repair mortar for underwater concrete structures which peformed the repair in the underwater according to the characteristic of the agricultural concrete structure. The latex modified repair mortar is a material that minimize the effect of the ecosystem, environment and the segregation. In this research, the construction condition of the latex modified repair mortar for agricultural concrete structures was considered and the test specimens made in the underwater condition. Test results was then compared with target performance and commercial repair mortar. Experimental test results indicated that the mechanical and durability performance of latex modified repair mortar for agricultural underwater concrete structure satisfied all target performance. Also, the latex modified repair mortar resulted in better repair performance than the commercial repair mortar.

Ride Performance Evaluation of a Heavy Truck Semi-active Cabin Air Suspension System (대형 트럭 반능동형 캐빈 공기 현가시스템의 승차감 성능 평가 연구)

  • Lee, Ji-Sun;Choi, Gyoo-Jae;Lee, Kwang-Heon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.5
    • /
    • pp.77-83
    • /
    • 2008
  • Semi-active cabin air suspension system improves driver's comfort by controlling the damping characteristics in accordance with driving situation. For the driver's comfort evaluation, test procedure has the two methodologies which are filed test and lab test. A field test method has a drawback. It requires a lot of time and money on repetitive test, due to the sensitivity of field test. On the other hand, the test with six axes simulation table at laboratory can obtain the repeatability of test, better than the field test method. In this paper, the procedures of ride performance test and control logic tuning with the table are presented. Drive files of the table can be represented with the almost same input condition as field test data. According to the result from the comparative test using six axes simulation table between passive and semi-active system by making ECU logic tuning, the RMS acceleration of semi-active cabin air suspension system was reduced by 29.6% compared with passive system.

Mechanical and Electrical Performance of 180kV HVDC Submarine Cable System (180kV HVDC 해저케이블 기계적/전기적 특성 평가)

  • Kim, N.Y.;Lee, T.H.;Lee, S.J.;Ji, B.K.;Kim, J.N.;Jeon, S.I.;Yun, H.S.;Joung, S.K.;Kang, C.H.;An, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.616-618
    • /
    • 2007
  • This paper describes the mechanical and electrical test on HVDC submarine cable, Flexible Repair Joint and termination for 180kV. This HVDC submarine cable was manufactured using LS cable's unique skill and would be applied the HVDC submarine cable system in korea. The performance test consist of mechanical test and electrical test. The tensile bending test and tensile test was done as the mechanical test and Electrical test is DC voltage and Impulse test. The tensile bending test carried out 6 times(double of specified times) for maximum reliability. The DC test voltage is $\pm$400kV/1hr. We estimate the lower limit of DC breakdown voltage is 600kV. The impulse test voltage is $\pm$800kV/10shots. The type of developed cables is the MI type. Its insulation consist of paper tapes impregnated with a high viscosity oil. The development of new HVDC cable is available for HVDC underground or submarine power transmission. The developed HVDC cable, FRJ and termination have passed the mechanical and electrical test successfully and showed excellent performance.

  • PDF

Preliminary Study for the Reliability Assurance on Results and Procedure of the Out-pile Mechanical Characterization Test for a Fuel Assembly; Lateral Vibration Test(I) (핵연료 집합체 노외성능시험의 절차와 결과에 대한 신뢰성확보를 위한 예비고찰; 횡방향 진동특성시험(I))

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Kim, Hyung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1854-1858
    • /
    • 2007
  • The reliability assurance with respect to the test procedure and results of the out-pile mechanical performance test for the nuclear fuel assembly is an essential task to assure the test quality and to get a permission for fuel loading into the commercial reactor core. For the case of vibration test, which is carried out to obtain basic dynamic characteristics of the fuel assembly, proper management and appropriate calibration of instruments and devices used in the test, various efforts to minimize the possible error during the test and signal acquisition process are needed. Additionally, the deep understanding both of the theoretical assumption and simplification cation for the signal processing/modal analysis and of the functions of the devices used in the test were highly required. Finally, to verify the test result to represent the accurate natural characteristics of the structure, the proper correlation analysis between the theoretical and experimental method has to be carried out. In this study, the overall procedure and result of lateral vibration test for the fuel assembly's mechanical characterization were briefly introduced. A series of measures to assure and improve the reliability of the vibration test were discussed.

  • PDF

Hydrodynamic Performance Test of a Turbopump Assembly (터보펌프 조립체의 수력 성능 시험)

  • Hong, Soon-Sam;Kim, Dae-Jin;Kim, Jin-Sun;Kim, Jin-Han
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • Hydrodynamic performance test of a turbopump for a liquid rocket engine is carried out. The turbopump is composed of an oxidizer pump, a fuel pump and a turbine, and the two pumps are driven by the turbine. In the test, water is used for the pumps as working media and air is used for the turbine. Performance parameters of pumps and a turbine are drawn, and a power balance between the pumps and the turbine are calculated. The calculation shows a good power balance, which implies that the pump component tests, the turbine component test and the assembly test are reliably performed. At the starting period of the test, pressure rise-flow rate curve of a pump gradually approaches the ideal curve which could be obtained by very slow starting.

A Study on the Development of Controller which is used Electric Operating Cell(EOC) for Vacuum Circuit Breaker and the Controller Performance Certification Test (진공차단기용 전자식 보조접점 컨트롤러 개발 및 성능인증시험에 관한 연구)

  • Lee, Ki-Seon;Park, Jung-Cheul;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.130-137
    • /
    • 2015
  • This study is about the controller development of the Electric Operating Cell(EOC) which will replace the Mechanical Operated Cell(MOC) of the vacuum circuit breaker which has been used in the power plant and the performance test for the developed controller. The controller developed through this study was manufactured considering the harsh installation environment and electrical condition of the power plant, and the controller performance certification test for confirming the product reliability was taken to know whether or not to withstand fully in various electrical and mechanical problems. Items for performance certification test were AC power frequency voltage withstand test, combined surge immunity test, 1 [MHz] oscillatory SWC test, fast transient SWC test, radiated electromagnetic interference test, vibration test. As a result, all tests has passed an examination without malfunction.

Qualification Test of a Main Coolant Pump for SMART Pilot (SMART 연구로 주냉각재펌프의 검증시험)

  • Park, Sang-Jin;Yoon, Eui-Soo;Oh, Hyoung-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.9 s.252
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

An Experimental Study on the Mechanical Mounting between GFRP Door Impact Beam and Steel Brackets (GFRP 도어 임팩트 빔과 Steel 브래킷의 기계적 결합에 관한 실험적 연구)

  • Ha, Jung-Chan;Shin, Young-cheol;Baek, In-Seok;Lee, Seok-Soon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.5
    • /
    • pp.103-110
    • /
    • 2021
  • The mounting performance of the GFRP(Glass fiber Reinforced Plastic) beam and the mechanical mounting of the steel bracket was studied to be mounted as a GFRP impact beam on the side door of the passenger car. Moreover, an open-hole tensile test was performed to evaluate breakage tendency based on GFRP stacking conditions. Furthermore, the tightening strength of rivets and bolts was compared using the single lap-shear tension test for the GFRP stacking pattern. Additionally, the GFRP beam and bracket mounting features were designed; moreover, the prototype and bracket were assembled. Additionally, the bracket mounting bending test and the door assembly static bending test were performed to verify the stability of the bracket mounting. In the bracket fastening bending test, no breakage occurred in the connection part between the GFRP beam and the bracket, and it showed 67% (24.4 kN) improved performance compared to steel. In the static bending test of the door assembly, the initial average reaction force increased by 25% compared to the steel, and the performance of all FMVSS-214 regulations was satisfied. The replacement of GFRP impact beams resulted in a 30% weight reduction

Study of the Functional Test and Quality Assurance Procedure of High Performance Aircraft Control Surfaces Integrate Servo Actuator (고성능 통합 비행 조정면 구동 장치의 성능 시험 및 품질보증 절차 수립에 관한 연구)

  • Jo, Jang-Hyen
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.3 no.3
    • /
    • pp.251-256
    • /
    • 2000
  • This report analyzes the Source Qualification Test which is composed of main functional and environmental tests for the localizing avionics(electronic subsystem for aircrafts and spacecraft) and high performance mechanical subsystem. Especially the detail test approaches of integrated servo actuators which is the main part to supply the power to the main and other flying control panel. Nowadays this subsystem works with mechanical and electrical engineering technique. In detail, electrical signal is used as input and transferring tool and mechanical part is the output as a power and manufacture the physical dimensions and functions. Finally in this review, the new test procedure to prove the function by the new manufacturer is established.

  • PDF

The Performance Analysis Method with New Pressure Loss and Leakage Flow Models of Regenerative Blower

  • Lee, Chan;Kil, Hyun Gwon;Kim, Kwang Yeong
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.221-229
    • /
    • 2015
  • For efficient design process of regenerative blower, the present study provides new generalized pressure and leakage flow loss models, which can be used in the performance analysis method of regenerative blower. The present performance analysis on designed blower is made by incorporating momentum exchange theory between impellers and side channel with mean line analysis method, and its pressure loss and leakage flow models are generalized from the related fluid mechanics correlations which can be expressed in terms of blower design variables. The present performance analysis method is applied to four existing models for verifying its prediction accuracy, and the prediction and the test results agreed well within a few percentage of relative error. Furthermore, the present performance analysis method is also applied in developing a new blower used for fuel cell application, and the newly designed blower is manufactured and tested through chamber-type test facility. The performance prediction by the present method agreed well with the test result and also with the CFD simulation results. From the comparison results, the present performance analysis method is shown to be suitable for the actual design practice of regenerative blower.