• 제목/요약/키워드: Mechanical calibration

검색결과 498건 처리시간 0.028초

영역분할과 2차원 커브피팅 함수들을 이용하는 직선형 5공 압력프로브의 성능 평가 (The Performance Assessment of a Straight-Type Five-Hole Pressure Probe Using a Zone Partition and Two-Dimensional Curve-Fitting Functions)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.22-31
    • /
    • 2014
  • This paper introduced the new calibration algorithm of a straight-type five-hole pressure probe necessary for calculating three-dimensional flow velocity components. The new velocity data reduction method using both a commercial two-dimensional curve-fitting program and the zone partition method of a calibration map was firstly introduced in this study. This new calibration method can be applied up to the wide flow angle of ${\pm}80^{\circ}$ despite of using a five-hole pressure probe because this data reduction method showed a comparatively good performance in calculating yaw and pitch angles from the calibration map.

렌즈왜곡효과를 보상하는 새로운 Hand-eye 보정기법 (A New Hand-eye Calibration Technique to Compensate for the Lens Distortion Effect)

  • 정회범
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.596-601
    • /
    • 2000
  • In a robot/vision system, the vision sensor, typically a CCD array sensor, is mounted on the robot hand. The problem of determining the relationship between the camera frame and the robot hand frame is refered to as the hand-eye calibration. In the literature, various methods have been suggested to calibrate camera and for sensor registration. Recently, one-step approach which combines camera calibration and sensor registration is suggested by Horaud & Dornaika. In this approach, camera extrinsic parameters are not need to be determined at all configurations of robot. In this paper, by modifying the camera model and including the lens distortion effect in the perspective transformation matrix, a new one-step approach is proposed in the hand-eye calibration.

  • PDF

실리콘 웨이퍼 휨형상 측정 정밀도 향상을 위한 시스템변수 보정법 (System calibration method for Silicon wafer warpage measurement)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제13권6호
    • /
    • pp.139-144
    • /
    • 2014
  • As a result of a mismatch of the residual stress between both sides of the silicon wafer, which warps and distorts during the patterning process. The accuracy of the warpage measurement is related to the calibration. A CCD camera was used for the calibration. Performing optimization of the error function constructed with phase values measured at each pixel on the CCD camera, the coordinates of each light source can be precisely determined. Measurement results after calibration was performed to determine the warpage of the silicon wafer demonstrate that the maximum discrepancy is $5.6{\mu}m$ with a standard deviation of $1.5{\mu}m$ in comparison with the test results obtained by using a Form TalySurf instrument.

Acquiring 3-dimensional data of a human face using a laser slit-ray projection method

  • Ishimatsu, T.;Taguchi, N.;Kawasue, K.;Kumon, K.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국제학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.816-821
    • /
    • 1988
  • This paper describes a system which enables a fast 3-dimensional measurement of a human face using a sli-ray projection method. One distinctive feature of our system is that a real-time video signal processor is employed in order to reduce the amount of image data to be processed and enable a fast measurement. Another feature of our system is that a skillful calibration software is developed. Due to this calibration software, opetators can be free from cumbersome settings of the measuring system.

  • PDF

다점식 피토관의 효율적인 교정에 대한 연구 (Investigation on the Effective Calibration of Annubar)

  • 최용문;최해만;최지철;홍경기;한상우;김웅선;전세종
    • 대한기계학회논문집B
    • /
    • 제30권4호
    • /
    • pp.373-380
    • /
    • 2006
  • Annubar is one of popular tools to measure the exhausted gas flow rate from the stacks. For the accurate monitoring of the amount of discharged pollutants, calibration of annubar is very important. Calibration of annubar has been carried out in a wind tunnel. When the length of annubar is longer than the test section size of wind tunnel, it is very difficult to find out typical value of annubar coefficients. So, a measurement technique to calibrate annubar longer than the size of the test section of wind tunnel must be developed. In the present study, an experiment is performed to measure the annubar coefficients in such a limited size of the wind tunnel. The experimental annubar coefficient by using a partial blocking technique is very close to the annubar coefficient of normal condition.

기준 외팔보를 이용한 액체 환경에서 Colloidal Probe의 수평방향 힘 교정 (Lateral Force Calibration of Colloidal Probe in Liquid Environment Using Reference Cantilever)

  • 제영완;정구현
    • Tribology and Lubricants
    • /
    • 제29권3호
    • /
    • pp.160-166
    • /
    • 2013
  • There is an indispensable need for force calibration for quantitative nanoscale force measurement using atomic force microscopy. Calibrating the normal force is relatively straightforward, whereas doing so for the lateral force is often complicated because of the difficulty in determining the optical lever sensitivity. In particular, the lateral force calibration of a colloidal probe in a liquid environment often has a larger uncertainty as a result of the effects of the epoxy, the location of the colloidal particle on the cantilever, and a decrease in the quality factor. In this work, the lateral force of a colloidal probe using a reference cantilever with a known spring constant was calibrated in a liquid environment. By obtaining the spring constant and the lateral sensitivity at the equator of a spherical colloidal particle, the damage to the bottom surface of the colloidal particle could be eliminated. Further, it was shown that the effect of the contact stiffness on the determination of the lateral spring constant of the cantilever could be minimized. It was concluded that this method can be effectively used for the lateral force calibration of a colloidal probe in a liquid environment.

액체용 중량식 유량계 교정장치의 일방향 Diverter 특성연구 (Characteristics of Uni-directional Diverter for Gravimetric Calibration Facility)

  • 남기한;박종호;김홍집
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.59-64
    • /
    • 2017
  • Diverter is an essential element in gravimetric calibration method of flowmeter. Error of diverter are influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. That's why, time detection position of diverter is tuned through repetitive test for minimizing error of diverter. Further the diverter must be compared with the other institutions test since the influence on the accuracy of the flow meter used in the test. In this paper, errors (flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location) of diverter are decreased by produced uni-direction diverter and error of gravimetric calibration system is decreased. Uni-direction diverter is calibrated by gravimetric calibration system with precision flowmeter, the flowmeter is calibrated by pipe prover and other institutions and uni-direction diverter is evaluated. Uni-direction diverter is not influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. As a result, Uni-direction diverter can calibrate in wider scope since increasing ratio of maximum and minimum flow rate of uni-direction diverter.

영상처리 기법을 이용한 부액계 자동 교정 시스템 구현 (Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing)

  • 이용재;장경호;오지윤;정상덕
    • 센서학회지
    • /
    • 제12권6호
    • /
    • pp.258-264
    • /
    • 2003
  • 본 연구에서는 영상처리를 통한 부액계의 교정방법을 연구한다. 이 방법은 부액계를 교정하기 위해 선정된 부액계의 측정눈금과 기준액체의 수평면을 교정자의 조작 없이 자동으로 일치시킨다. 이 시스템은 CCD카메라, frame grabber, 스텝모터, 영상처리를 포함한 시스템프로그램으로 구성된다. 영상처리프로그램은 부액계의 측정눈금부위와 기준액체의 수평면사이에서 발생하는 메니스커스를 검색하여 눈금을 일치시키는 부분과 스텝모터를 제어하는 부분으로 구성한다. 본 연구에서 개발한 시스템의 성능을 검증하기 위하여 교정자의 눈으로 직접 메니스커스와 측정눈금을 관측한 수동교정방법의 교정결과와 비교한다 각각의 교정값의 차이가 $0.004\;kg/m^3$ 이하로서 교정값의 측정 불확도 $0.06\;kg/m^3$을 고려하면 두 방법의 교정결과가 거의 같은 연구결과를 얻었다.

전자기 수치 해석을 이용한 Combo 표준 보정 시험편의 MRPC Probe 와전류 신호 모사 및 평가 (Simulation and Evaluation of ECT Signals From MRPC Probe in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis)

  • 유주영;송성진;정희준;공영배
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.90-98
    • /
    • 2006
  • 원전 증기 발생기 세관의 MRPC probe 신호를 검사하고 평가하기 위해서는 일반적으로 Combo 표준 보정 시험편 신호가 신호 보정을 위해 사용된다 이렇듯 Combo 표준 보정 시험편 신호는 신호 평가에 중요한 영향을 미치지만, probe 상태나 관 주위의 여러 요소에 의해 쉽게 영향을 받기 때문에 결함 평가 요소인 신호의 크기 값과 위상각을 왜곡시킬 수 있다. 따라서 본 연구는 이런 문제점을 극복하기 위해 Combo 표준 보정 시험편의 실제 신호를 모사 신호로 대체하는 가능성을 알아보기 위해 실험을 해 보았다 이를 위해 MRPC probe와 Combo 표준 보정 시험편의 특성을 조사하였으며 계산 수행을 위해 체적 적분 방법으로 계산되는 상용 전자기 해석 프로그램인 VIC-3D를 사용하였고 모사 신호를 생성한 후 실험 신호와 비교를 통해 신호의 정확성을 확인하였다. 마지막으로, 모사 신호를 이용한 결함 평가를 위하여 실제 결함과 가공 결함에 대해 위상각과 크기 값의 항목으로 평가하여 실제 결함 평가자에 의한 결과와 비교하였다.

단일장치로 발사환경구속 및 결함안전기능이 가능한 전개수납형 교정 메커니즘의 기능검증 (Performance Verification of Deploy/Stow-type Calibration Mechanism with Dual-function of Launch Locking and Fail-Safe)

  • 이명재;김태규;조문신;오현웅
    • 한국항공우주학회지
    • /
    • 제44권10호
    • /
    • pp.895-903
    • /
    • 2016
  • 우주용 영상센서의 비균일 출력특성 교정을 통한 영상품질향상을 목적으로 탑재교정장치가 요구된다. 탑재교정장치는 균일한 온도정보 제공을 위한 흑체를 비롯하여, 흑체로의 지향성 확보를 위하여 전개/수납 기능이 포함되는 교정 메커니즘으로 구성된다. 이 중, 교정 메커니즘은 궤도상에서 구동장치의 결함 발생 시 주광경로 확보를 위한 결함안전 기능이 요구된다. 추가적으로, 구동부에 대한 발사환경에서의 구조건전성 확보가 필수적이다. 본 논문에서는 단일장치로 발사환경 구속 및 결함안전 기능 구현이 가능한 전개수납형 교정 메커니즘을 제안하였다. 상기 제안한 메커니즘의 기능모델을 통한 동작 기능시험을 수행하여 설계의 유효성을 입증하였다.