• 제목/요약/키워드: Mechanical calibration

검색결과 498건 처리시간 0.029초

삼직교 열선유속계의 간편한 측정법 개발 (Development of Easy Measurement Method of Orthogonal Triple-Sensor Hot-Wire Anemometer)

  • 김진권;강신형
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.85-92
    • /
    • 2000
  • Easy measurement method of orthogonal triple-sensor hot-wire anemometer is developed. Advantages of the new method is that it does not require either the exact orthogonality of the installed wires which cannot be kept during the probe manufacture and repair, nor the knowledge of the wire installation angles and the yaw and pitch coefficient of the wires. The new method introduced yaw and pitch calibration coefficients which are designed to increase monotonically with yaw and pitch angles. So the resulting calibration network is simple to recognize compared with that of the previously suggested calibration method. Verification experiments showed good accuracy and independency of the directional calibration on velocity.

Multiple Pivot loading 방법을 이용한 액체 환경에서의 수평방향 힘 교정 (Lateral Force Calibration in Liquid Environment using Multiple Pivot Loading)

  • 김류운;정구현
    • Tribology and Lubricants
    • /
    • 제29권2호
    • /
    • pp.91-97
    • /
    • 2013
  • Quantifying the nanoscale force between the atomic force microscopy (AFM) probe of a force-sensing cantilever and the sample is one of the challenges faced by AFM researchers. The normal force calibration is straightforward; however, the lateral force is complicated due to the twisting motion of the cantilever. Force measurement in a liquid environment is often needed for biological applications; however, calibrating the force of the AFM probes for those applications is more difficult owing to the limitations of conventional calibration methods. In this work, an accurate nondestructive lateral force calibration method using multiple pivot loading was proposed for liquid environment. The torque sensitivity at the location of the integrated probe was extrapolated based on accurately measured torque sensitivities across the cantilever width along a few cantilever lengths. The uncertainty of the torque sensitivity at the location of the integrated tip was about 13%, which is significantly smaller than those for other calibration methods in a liquid environment.

동력식 조립공구의 측정불확도 산출방법 개발 (Calibration Methods for Measurement Uncertainty of Power Assembly Tools)

  • 오세헌;강기영;홍민성
    • 한국생산제조학회지
    • /
    • 제24권5호
    • /
    • pp.496-501
    • /
    • 2015
  • In this study, calibration procedure of power assembly tools is suggested and methods are developed for calculating measurement uncertainty. Fist of all, the calibration of joint simulator bench (JSB) was carried out for maintaining traceability and the uncertainty components of JSB were analyzed. The influences of tool speed, tolerance, temperature and length of the adapter were examined by the torque measurement values through experiments. From this research, credibility for calibration results could be enhanced. This experimental results, being used as an effective tool for calibration of power assembly tools, will provide and improve the accuracy of the use of the power assembly tools.

선박용 곡판형상의 실시간 측정을 위한 다중 슬릿빔 보정법 (3D Calibration Method on Large-Scale Hull Pieces Profile Measurement using Multi-Slit Beams)

  • 김병창;이세한
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.968-973
    • /
    • 2013
  • In the transportation industry, especially in the shipbuilding process, 3D surface measurement of large-scale hull pieces is needed for fabrication and assembly. We suggest an efficient method for checking the shape of curved plates under the forming operation with short time by measuring 3D profiles along the multi lines of the target surface. For accurate profile reconstruction, 2D camera calibration and 3D calibration using gauge blocks were performed. The evaluation test shows that the measurement accuracy is within the boundary of tolerance required in the shipbuilding process.

길이 측정 센서를 이용한 병렬기구의 기하학적 오차 보정 (Calibration of Geometric Errors of a Parallel Manipulator Using a Sensor of Length Measurement)

  • 최우천;임현규
    • 한국정밀공학회지
    • /
    • 제17권11호
    • /
    • pp.94-100
    • /
    • 2000
  • This paper proposes a method of geometric error calibration for a parallel using only sensor of length measurement without additional sensors. The concept is generalized which creates measurement residuals by exploring conflicting information provided with external length sensing. Although this calibration method requires many configurations, it has an advantage of using relatively simple length measurements. This method is shown to provide good calibration results, especially when there exist smaller measurement noises and more configurations are measured.

  • PDF

Reports on the Meetings of ISO/TC108 Mechanical Vibration and Shock and ISO/TC108/SC3 Use and Calibration of Shock Measuring Instruments Tokyo, Nov. 4-8, 2002

  • Kim, Kwang-Joon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.468-474
    • /
    • 2003
  • 1. Schedule for the meetings of ISO/TC108 Mechanical vibration and shock and ISO/TC108/SC3 Use and calibration of shock measuring instruments 2. Minutes for the seventh meeting of ISO/TC108/WG23 Mechanical vibration and shock - Resilient mounting systems - Information for the application of source and receiver isolation (omitted)

  • PDF

고무와 섬유로 구성된 복합체 내의 섬유 끝 부분의 원형 균열에 대한 J-적분 (J-integral of Penny-Shaped Crack on the End of Stiff Fiber Embedded in Rubbery Materials)

  • 양경진;강기주
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.617-624
    • /
    • 2002
  • An equation of J-integral for a penny-shaped crack at the end of the fiber embedded in rubber matrix is proposed. The values of J-integral for the specimens with various crack and specimen radius are obtained by FEA(Finite Element Analysis). The dimensional analysis is applied to derive an equation of J-integral as a nonlinear elastic energy release rate. The geometry and deformation calibration function in an equation of J can be expressed in a separated form. The geometry calibration function characterizing the effects of cord and specimen size is expressed in a polynomial form of fourth order. The deformation calibration function characterizes the effect of the overall level of strain. As approaching the infinitesimal strain, the value of the deformation calibration function approaches the results of LEFM(Linear Elastic Fracture Mechanics).

Measurement of local wall temperature and heat flux using the two-thermocouple method for a heat transfer tube

  • Ahn, Taehwan;Kang, Jinhoon;Jeong, Jae Jun;Yun, Byongjo
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1853-1859
    • /
    • 2019
  • The two-thermocouple method was investigated experimentally to evaluate its accuracy for the measurement of local wall temperature and heat flux on a heat transfer tube with an electric heater rod installed in an annulus channel. This work revealed that a thermocouple flush-mounted in a surface groove serves as a good reference method for the accurate measurement of the wall temperature, whereas two thermocouples installed at different depths in the tube wall yield large bias errors in the calculation of local heat flux and wall temperature. These errors result from conductive and convective changes due to the fin effect of the thermocouple sheath. To eliminate the bias errors, we proposed a calibration method based on both the local heat flux and Reynolds number of the cooling water. The calibration method was validated with the measurement of local heat flux and wall temperature against experimental data obtained for single-phase convection and two-phase condensation flows inside the tube. In the manuscript, Section 1 introduces the importance of local heat flux and wall temperature measurement, Section 2 explains the experimental setup, and Section 3 provides the measured data, causes of measurement errors, and the developed calibration method.

A New Calibration Method of Atomic Force Microscopy

  • Hyunkyu Kweon
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권2호
    • /
    • pp.11-16
    • /
    • 2001
  • This paper presents an in self-calibration method to corrent the Z-directional distortion of AFM(Atomic Force Microscopy).

  • PDF