• Title/Summary/Keyword: Mechanical amplifier

Search Result 145, Processing Time 0.027 seconds

Characteristics of a PZT-Driven Micro Depth Adjustment Device for Cutting Coated Film (박막 절단용 PZT 구동 미세깊이 조절 장치의 특성)

  • Ryu, Sang-Oh;Kim, Hwa-Young;Ahn, Jung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.630-635
    • /
    • 2014
  • This study aims to develop a PZT-driven depth adjustment device with a flexure hinge and to investigate its static/dynamic characteristics. This device will be applied to rapidly and accurately trace a flat surface with slight waviness of up to several hundreds of micrometers in magnitude. One typical example is to cut a film coated on a steel plate. A depth control system composed of PMAC, PZT/PZT amplifier, flexure hinge/knife, and laser displacement sensor is implemented on a desktop three-axis machine and an actual cutting test is conducted on a steel workpiece with a sinusoidal-wavy surface. It is verified that the dynamic characteristics of the device limit the maximum cutting speed and depth precision.

The Influence of Assembling Errors on the Performance of the Rotor Supported by Active Magnetic Bearings (조립오차가 능동 자기베어링으로 지지된 축의 성능에 미치는 영향)

  • Kim, Dae-Gon;Kim, Kyung-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.12
    • /
    • pp.3909-3916
    • /
    • 1996
  • Magnetic bearing is the machine element that supports the shaft without mechanical contact using the magnetic force induced by permanent magnet of electromagnet. Active magnetic bearing system is composed of sensor, controller, power amplifier, and electromagnet. If all the elements were dieal, shaft position could be controlled to sensor resolution, Because each elements inreal system have mechanical and electricla losses and nonlinearity, it is impossible to attain the desired performance using general control algorithm. So far it has been studied on improvement of the control algorithm of the electric characteristics of each elements. Another factors to affect shaft behavior are the manufacturing errors due to machine work, and assembling errors due to accumulate manufacturing errors of the radial magnetic bearing. This paper describes that the shaft behavior due to accumulate manufacturing errors and asymmetric bolting. This paper describes that the shaft behavior due to assembling errors of the radial bearings donot affect the rotaitonal accuracy of the shaft. But when the amplitude of the assembling errors increasees over the certain value, the bearing can not support the shaft properly.

A Low cost Sensorless Control Circuit for Permanent Magnet Synchronous Motor (영구자석 동기 전동기의 염가형 센서리스 제어회로)

  • 양순배
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.434-438
    • /
    • 2000
  • In this paper the low cost sensorless control circuit for a PM synchronous motor without the mechanical rotor position sensors is presented. The sensorless control algorithm and position detection circuit for the sinusoidal current wave drive is more complex than that of the rectangular current wave drive. The proposed position sensing circuit is composed of an operational amplifier and several passive elements. The design procedures for getting the optimal parameters for the position sensing circuit are presented. The performance of the proposed algorithm is verified through the simulations and experiments.

  • PDF

Application of Piezoelectric-based Actuators to Helicopter Vibration Reduction (4)

  • Kim, Jun-Sik
    • Journal of KSNVE
    • /
    • v.20 no.6
    • /
    • pp.24-28
    • /
    • 2010
  • Many methodologies have been explored to reduce helicopter vibration. Trailing edge flaps for such a purpose have been studied for the past twenty years. A brief overview of the introduction of active vibration controls using trailing edge flaps and smart actuators is presented in series. This is the fourth article, in which a piezoelectric resonant actuation system with a buckling-beam motion amplifier for active trailing edge flaps is presented.

Buckling analysis of nanocomposite cut out plate using domain decomposition method and orthogonal polynomials

  • Jamali, M.;Shojaee, T.;Kolahchi, R.;Mohammadi, B.
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.691-712
    • /
    • 2016
  • In this editorial, buckling analytical investigation of the nanocomposite plate with square cut out reinforced by carbon nanotubes (CNTs) surrounded by Pasternak foundation is considered. The plate is presumed has square cut out in center and resting on Pasternak foundation. CNTs are used as amplifier in plate for diverse distribution, such as uniform distribution (UD) and three patterns of functionally graded (FG) distribution types of CNTs (FG-X, FG-A and FG-O). Moreover, the effective mechanical properties of nanocomposite plate are calculated from the rule of mixture. Domain decomposition method and orthogonal polynomials are applied in order to define the shape function of nanocomposite plate with square cut out. Finally, Rayleigh-Ritz energy method is used to obtain critical buckling load of system. A detailed parametric study is conducted to explicit the effects of the dimensions of plate, length of square cut out, different distribution of CNTs, elastic medium and volume fraction of CNTs. It is found from results that increase the dimensions of plate and length of square cut out have negative impact on buckling behavior of system but considering CNTs in plate has positive influence.

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.

Design of Multilevel Variable Output Voltage AC-DC Converter for Power Amplifier of Underwater Acoustic Sensor (수중 음향센서용 전력증폭기를 위한 멀티레벨 가변전압출력 AC-DC 전원회로 설계)

  • Lee, Chang-Yeol;Kim, In-Dong;Nho, Eui-Cheol;Moon, Won-Kyu;Kim, Won-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.72-83
    • /
    • 2013
  • The paper proposes a new multilevel variable output voltage AC/DC Converter for power supply of power amplifiers used in underwater acoustic sensors. The proposed multilevel variable output voltage AC/DC Converter is composed of two parts. One as the input section is the high efficiency phase-shifted PWM full bridge DC-DC converter to get multiport power sources. The other as the output section is composed of two flying-capacitor 3-level DC-DC converters and a diode bridge circuit to get fast-response and multilevel variable output voltage for an envelope amplifier. Also the paper suggests the detailed circuit topology and design guideline of multilevel variable output voltage AC/DC converter. It also proposes the power balanced control method between 3-level converters and the voltage balanced algorithm for flying capacitors. Its characteristics should be verified by the detailed simulation results. It is anticipated that the proposed converter will be used very well for power amplifiers used in underwater acoustic sensors.

Micro-positioning of a Smart Structure using an Enhanced Stick-slip Model (향상된 스틱-슬립 마찰 모델을 이용한 스마트 구조물의 마이크로 위치제어)

  • Lee, Chul-Hee;Jang, Min-Gyu;Choi, Seung-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.230-236
    • /
    • 2008
  • In this paper, a model-based stick-slip compensation for the micro-positioning is proposed using an enhanced stick-slip model based on statistical rough surface contact model. The smart structure is comprised with PZT (lead (Pb) zirconia (Zr) Titanate (Ti)) based stack actuator incorporating with the PID (Proportional-Integral-Derivative) control algorithm, mechanical displacement amplifier and positioning devices. For the stick-slip compensation, the elastic-plastic static friction model is used considering the elastic-plastic asperity contact in the rough surfaces statistically. Mathematical model of system for the positioning apparatus was derived from the dynamic behaviors of structural parts. PID feedback control algorithms with the developed stick-slip model as well as feedforward friction compensator are formulated for achieving the accurate positioning performance. Experimental results are provided to show the performances of friction control using the developed positioning apparatus.

  • PDF

Continuous Blood Pressure Monitoring using Pulse Wave Transit Time

  • Jeong, Gu-Young;Yu, Kee-Ho;Kim, Nam-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.834-837
    • /
    • 2005
  • In this paper, we describe the method of non-invasive blood pressure measurement using pulse wave transit time(PWTT). PWTT is a new parameter involved with a vascular that can indicate the change of BP. PWTT is measured by continuous monitoring of ECG and pulse wave. No additional sensors or modules are required. In many cases, the change of PWTT correlates with the change of BP. We measure pulse wave using the photo plethysmograph(PPG) sensor in an earlobe and we measure ECG using the ECG monitoring device our made in the chest. The measurement device for detecting pulse wave consists of infrared LED for transmitted light illumination, pin photodiode as light detector, amplifier and filter. We composed 0.5Hz high pass, 60Hz notch and 10Hz low pass filter. ECG measurement device consists of multiplexer, amplifier, filter, micro-controller and RF module. After amplification and filtering, ECG signal and pulse wave is fed through micro-controller. We performed the initial work towards the development of ambulatory BP monitoring system using PWTT. An earlobe is suitable place to measure PPG signal without the restraint in daily work. From the results, we can know that the dependence of PWTT on BP is almost linear and it is possible to monitoring an individual BP continuously after the individual calibration.

  • PDF

Forced Vibration Analysis of 4 DOF system for Design of Slip-Stick Actuator (슬립-스틱 구동기 설계를 위한 4자유도 시스템 강제진동 해석)

  • Song, Myeong-Gyu;Hur, Young-Jun;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su;Lim, Soo-Cheol;Park, Jae-Hyuk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.214-215
    • /
    • 2009
  • The friction is inevitable and unpredictable phenomena, so most mechanical systems are designed to low friction effect by using bearings and lubricants. However, the slip-stick actuator applies the friction force to its movement. The slip-stick mechanism is applied the piezoelectric actuator to overcome short displacement. Fast response of piezoelectric actuator is also good characteristic for the slip-stick mechanism. However, the piezoelectric actuator with slip-stick mechanism isn't common, because its cost and driving voltage are too high. In this paper, a voice-coil actuator with slip-stick mechanism is introduced. The cost and the driving voltage of a voice-coil actuator are much less than the piezoelectric actuator. And a dynamic vibration amplifier is proposed to adjust the dynamic performance of the actuator. By the results of numerical analysis, the feasibility of a dynamic vibration amplifier is verified.

  • PDF