• Title/Summary/Keyword: Mechanical Test

Search Result 11,543, Processing Time 0.041 seconds

Thin Layer Drying and Quality Characteristics of Ainsliaea acerifolia Sch. Bip. Using Far Infrared Radiation (원적외선을 이용한 단풍취의 박층 건조 및 품질 특성)

  • Ning, Xiao Feng;Li, He;Kang, Tae Hwan;Lee, Jun Soo;Lee, Jeong Hyun;Ha, Chung Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.6
    • /
    • pp.884-892
    • /
    • 2014
  • The purpose of this study was to investigate the drying characteristics and drying models of Ainsliaea acerifolia Sch. Bip. using far-infrared thin layer drying. Far-infrared thin layer drying test on Ainsliaea acerifolia Sch. Bip. was conducted at two air velocities of 0.6 and 0.8 m/sec, as well as three drying temperatures of 40, 45, and $50^{\circ}C$ respectively. The drying models were estimated using coefficient of determination and root mean square error. Drying characteristics were analyzed based on factors such as drying rate, leaf color changes, antioxidant activity, and contents of polyphenolics and flavonoids. The results revealed that increases in drying temperature and air velocity caused a reduction in drying time. The Thompson model was considered suitable for thin layer drying using far-infrared radiation for Ainsliaea accerifolia Sch. Bip. Greenness and yellowness values decreased and lightness values increased after far-infrared thin layer drying, and the color difference (${\Delta}E$) values at $40^{\circ}C$ were higher than those at $45^{\circ}C$ and $50^{\circ}C$. The antioxidant properties of Ainsliaea acerifolia Sch. Bip. decreased under all far-infrared thin layer drying conditions, and the highest polyphenolic content (37.9 mg/g), flavonoid content (22.7 mg/g), DPPH radical scavenging activity (32.5), and ABTS radical scavenging activity (31.1) were observed at a drying temperature of $40^{\circ}C$ with an air velocity of 0.8 m/sec.

Fabrication and Characterization of Transparent Conductive Film based on Bacterial Cellulose (Bacterial cellulose를 기반으로 하는 투명전도성막의 제조 및 특성평가)

  • Yim, Eun-Chae;Kim, Seong-Jun;Kee, Chang-Doo
    • Korean Chemical Engineering Research
    • /
    • v.51 no.6
    • /
    • pp.766-773
    • /
    • 2013
  • A transparent film was fabricated based on bacterial cellulose (BC), BC has excellent physical strength and stability at high temperature and it is an environmental friendly flexible material. In order to improve the conductivity, silver nanowire (AgNW) and/or graphene were introduced to the BC membrane. The aspect ratio of the AgNW synthesized in this study was 214, with a length of $15{\mu}m$ and width of 70 nm. The higher aspect ratio improved the conductivity by reducing the contact resistance. The thermal and electrical properties of 7 types of films prepared were investigated. Each film was fabricated with rectangular shape ($2mm{\times}2mm{\times}50{\mu}m$). The films were scored with a net shape by a knife, and filled with AgNW and graphene to bestow conductivity. The film filled with AgNW showed favorable electrical characteristics with a thickness of $350{\mu}m$, electron concentration of $1.53{\times}10^{19}$, electron mobility of $6.63{\times}10^5$, and resistivity of 0.28. The film filled with graphene had a thickness of $360{\mu}m$, electron concentration of $7.74{\times}10^{17}$, electron mobility of 0.17, and resistivity of 4.78. The transmittances at 550 nm were 98.1% and 80.9%, respectively. All the films were able to light LEDs bulbs although their brightness differed. A thermal stability test of the BC and PET films at $150{\pm}5^{\circ}C$ showed that the BC film was more stable, whereas the PET film was quickly banded. From these results, it was confirmed that there it is possible to fabricate new transparent conductivity films based on BC.

Introduction and feasibility study of the HD-270 MLC (HD-270 MLC의 소개 및 유용성평가)

  • Kim Dae Young;Kim Won Taek;Lee Hwa Jung;Lee Kang Hyeok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-9
    • /
    • 2003
  • I. Purpose The multileaf collimator(MLC) has many advantages, but use of the MLC increased effective penumbra and isodose undulation in dose distribution compared with that of an alloy block. In this work, we introduced the HD-270 MLC, which can improve the above disadvantages of MLC, and reported its feasibility study. II. Method and Materials The HD-270 MLC is a technique which combines the use of the existing Siemens multileaf collimator(3D MLC) with patient translation perpendicular to the leaf plane. The technique produces a smoothed isodose distribution with the reduced isodose undulation and effective penumbra. To assess the efficacy of the HD-270 technique and determine the appropriate resolution, a polygonal shaped MLC field was made to produce field edge angles from 0 degree to 75 degree with a step of 15 degree. Each HD-270 group was generated according to the allowed resolution, i. e., 5, 3, and 2mm. The experiment was carried out on Primus, a Siemens linear accelerator configured with HD-270 MLC. The total 60 MU of 6 MV photon beam was delivered to X-Omat film(Kodak, USA) at a SAD of 100 cm and 1.5 cm depth in solid water phantom. Exposed films were scanned by Lumiscan75(LUMISYS) and analyzed using RIT113 software(Radiological Imaging Technology Inc., USA). To test the mechanical accuracy of table movement, the transverse, longitudinal, and vertical positions were controlled by a consol with ${\pm}5\;mm,\;{\pm}4\;mm,\;{\pm}3\;mm,\;and\;{\pm}2\;mm$ steps, and then measured using a dial gauge with an accuracy of 0.001 inch. During the experiments, the table loaded with about 50Kg human phantom to simulate the real treatment situation. III. Results The effective penumbra and isodose undulation became larger with increase the resolution and field edge angle. The accuracy of the table movement on each direction is good within the ${\pm}1\;mm$. IV. Conclusion Clinical use of the MLC can be increased by using of the HD-270 MLC which complements to the disadvantages of the MLC.

  • PDF

Effects of Chitosan on Quality and Shelf-life of Paeksulgis Added Chitosan (키토산 첨가에 따른 백설기의 품질특성 및 저장성)

  • 정현숙;박찬성;노홍균
    • Food Science and Preservation
    • /
    • v.8 no.4
    • /
    • pp.427-433
    • /
    • 2001
  • The purpose of this study was to investigate the effect of chitosan on the shelf-life and quality of Paeksulkis(Korea rice cake). Paeksulgis containing 0-0.5% chitosan were stored at 5$^{\circ}C$ for 4 week and 2$0^{\circ}C$ for 1 week to test the effect of extenting shelf-life of Paeksulgis by chitosan. The pH of Paeksulkis was 5.65 without chitosan and pH of those were about 7.0(6.94-7.01) with 0.05-0.5% level of chitosan. Moisture content of Paekrukis wish or without chitosan was 38-40%. In Hunter’s color values of Paeksulkis of control, the lightness (L) was 84.28, redness(a) was -1.56 and yellowness(b) was 7.68. The lightness (L), redness(a) and yellowness(b) of Paeksulkis were increased by the increasing concentration of chitosan. In mechanical characteristics, cohesiveness concentration of Paeksulkis were the highest in control while obtained the highest score in color, after swallowing and overall quality (p<0.05). The score of flavor and consistency of Paeksulkis with different levels of chitosan wre not significant while the score of moisture in Paeksulkis with 0.05-0.5% level of chitosan was significantly higher than control (p<0.05). The score of flavor and consistency of Paeksulkis with different levels of chitosan were not significant while the score of moisture in Paeksulkis with 0.05-0.5% level of chitosan was significantly higher than control (p<0.05). Total bacterial counts (TBC) of Paeksulgis immediately before storage were 4.2$\times$10$^2$CFU/g in control and those containing 0.3-0.5% of chitosan were 0.5-1.0 log cycle lower than control. TBC of Paelsulgis containing chitosan was lower than increased for 2 weeks, reached at 1.8$\times$10$^{5}$ CFU/g and decreased for 2 weeks, reached at 1.8$\times$10$^4$CFU/g during storage at 5$^{\circ}C$. TBC of Paeksulkis with more than 0.3% of chitosan were 1.9 log cycles lower than that of control during storage at 5$^{\circ}C$. TBC of Paeksulkis with more than 0.3% of chitosan were 1.9 log cycles lower than that of control during storage at 5$^{\circ}C$ for 4 weeks. TBC of Paeksulgis increased to 10$^{8}$ CFU/g in control and 10$^{6}$-10$^{7}$ CFU/g in more than 0.3% chitosan during storage at 20$^{\circ}C$ for 1 week. The shelf-life of Paeksulkis was increased with increasing concentration of chitosan both temperature at 5$^{\circ}C$ and 20$^{\circ}C$.

  • PDF

Measurement of Soil Hardness for Puddling Soil for Mechanical Rice Transplantation (기계이앙(機械移秧) 준비답(準備畓)의 토양경도(土壤硬度) 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Hong Yun;Kim, Soung Rai;Kim, Ki Dae
    • Korean Journal of Agricultural Science
    • /
    • v.13 no.2
    • /
    • pp.243-254
    • /
    • 1986
  • This study was conducted to select the appropriate types of drop cone for measuring soil hardness and to determine the cone index for the actual field on which rice will be transplanted. One type of drop cone was selected from the results of indoor tests and the selected drop cone was tested at the 56fields of the five different districts in Korea. The results of this study were summarized as follows; 1. Cone type D shows a significant penetrating depth variation comparing the other types of cone on the indoor tests. 2. Six types of cone were tested on the similar state of the actual puddling field. The penetrating depth variation was not significant among the cones but cone type F seemed to be suitable to evaluate the state of puddling because cone type F showed the least repeat variations during the tests. 3. The actual field test from 56 fields showed that the penetrating depth was approximately 11.0-14.4cm on the puddling day and it was 9.2-13.7cm on the transplanting day of which one to three days after puddling. 4. The above results show that the selected drop cone could be used to formulate the state of puddling.

  • PDF

Preparation and Quality Characterization of Apple Jam with Rosa rugosa Thunb. Fruit (해당화 열매 첨가 사과잼 제조 및 품질 특성)

  • Kim, Mi-Hyun;Kim, Myung-Hee;Yun, Sun-Ju;Lee, Byung-Yong;Lee, Chang-Won;Kim, Bo-Ae;Jang, Ki-Hyo;Lee, Jae-Cheol;Surh, Jeong-Hee
    • Korean journal of food and cookery science
    • /
    • v.26 no.4
    • /
    • pp.367-380
    • /
    • 2010
  • Various contents of Rosa rugosa Thunb. fruit(0, 10, 20%), which is grown along the seashore of Gangwon province, were applied to apple jams having different sugar concentrations(20, 40, 60%). The resulting jams were analyzed using a sensory scoring test as well as a response surface methodology to identify the optimum conditions for the preparation of high-preference apple jams. The sensory properties based on sense of sight, smell and taste appeared to be linked to the sugar contents. It could be attributed to the presence of flavor compounds and pigments generated from the caramelization of sugar molecules during heat processing. On the other hand, rheological properties such as viscosity and spreadability were associated with Rosa rugosa fruit content, which was also verified by textural analysis of the jams. As the contents of Rosa rugosa increased, the hardness, gumminess, and chewiness of the jams decreased, which eventually might have contributed to the less thick and thus more spreadable sensory characteristics. Sensory evaluation revealed that apple jams were preferred when prepared with $\leq$10% of Rosa rugosa fruit and $\geq$55% of sugar contents. In particular, apple jams containing 10% Rosa rugosa and 60% sugar showed better mechanical qualities as well as higher sensory preference among 10 jams formulated using central composite design.

Development of Liquid Cadmium Cathode Structure for the Inhibition of Uranium Dendrite Growth (수지상 우라늄 성장억제를 위한 액체카드뮴 음극구조 개발)

  • Paek, Seung-Woo;Yoon, Dal-Seong;Kim, Si-Hyung;Shim, Jun-Bo;Ahn, Do-Hee
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.1
    • /
    • pp.9-17
    • /
    • 2010
  • The LCC (Liquid Cadmium Cathode) structure to be developed for inhibiting the formation and growth of the uranium dendrite has been known as a key part in the electrowinning process for the simultaneous recovering of uranium and TRU (TRans Uranium) elements from spent fuels. A zinc-gallium (Zn-Ga) experimental system which is able to be functional in aqueous condition and normal temperature has been set up to observe the formation and growth phenomena of the metal dendrites on liquid cathode. The growth of the zinc dendrites on the gallium cathode and the performance of the existing stirrer type and pounder type cathode structure were observed. Although the mechanical strength of the dendrites appeared to be weak in the electrolyte and easily crashed by the various cathode structures, it was difficult to effectively submerge the dendrite into the bottom of the liquid cathode. Based on the results of the aqueous phase experiments, a lab-scale electrowinning experimental apparatus which are applicable to the development of LCC srtucture for the electrowinning process was established and the performance tests of the different types of LCC structure were conducted to prohibit the uranium dendrite growth on LCC surface. The experimental results of the stirrer type LCC structures have shown that they could not effectively remove the uranium dendrites growing at the inner side of the LCC crucible and the performances of the paddle and harrow type LCC structure were similar. Therefore a mesh type LCC structure was developed to push down the uranium dendrites to the bottom of the LCC crucible growing on the LCC surface and at the inner side of the crucible. From the experimental results for the performance test of the mesh type LCC structure, the uranium was recovered over 5 wt% in cadmium without the growth of uranium dendrites. After completion of the experiments, solid precipitates of the bottom of the LCC crucible were identified as an intermetallic compound (UCd11) by the chemical analysis.

A Study on Stage of Concern, Level of Use, Innovation Configuration, and Intervention demand of Teachers in Culinary Practice Education (조리실습 교육에 대한 교사의 관심도, 실행 수준, 실행 형태 및 지원 요구도 조사)

  • Park Eun-Sook;Kim Young-Nam
    • Journal of Korean Home Economics Education Association
    • /
    • v.18 no.3 s.41
    • /
    • pp.41-60
    • /
    • 2006
  • The system of teaching culinary practice needs drastic modification to catch up with dietary life and education curriculum changes. To reflect such changes, it is necessary to instill a strong will and interest as well as educational environment improvement in teachers. In this sense, this study researched the teachers' stages of concerns, levels of use, innovation configuration, and intervention demands, based on the CBAM(Concerns Based Adoption Method) developed by Hord et. al. For the survey, 500 questionnaires sent by mail and 187 were analyzed by SPSS/win 10.0 program. The results are summarized as follows. 1) The teachers stages of concerns on culinary practice is assessed to be in the lowest level of perceptual stage, which indicates a state of indifference. 2) In terms of the levels of use, routine use was the highest, followed by refinement use, integrated use, research use, and reinvent use in descending order. Mechanical use posted the lowest level. Even though the stages of concern showed the beginning stage, the Level of use was relatively high. 3) About the innovation configuration, approximately 30% of the teachers were not accomodate the culinary practice referred to the 7th National Education Curriculum. 4) According to the intervention demands on culinary practice education, it was found that teachers generally wanted more interventions in every component. Among the intervention components, the highest demand was on the support for facility. Demand on the financing is the second highest. Teachers in the level of routine use demanded more information and materials supply and individual encouragement, but teachers in the level of preparation needed study opportunity for training on operation skills more.

  • PDF

The Study on the Relationship Between the Duration of Chest Vibration prior to Endotracheal Suctioning and the Changes in Oxygen Saturation in Low-Birth-Weight Infants (저체중아에 있어 기관내 흡인전 흉부진동법의 기관과 산소포화 변화간의 관계 연구)

  • Ahn, Young-Mee
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.3
    • /
    • pp.597-607
    • /
    • 1995
  • 1960년대 이후 인공호흡기(mechanical ventilator)의 보급과 최근 의료과학의 발달, 간호의 질적 향상의 결과로 저체중출생아를 포함한 고위험 신생아의 생존율이 높아져왔다. 호흡장애증후군(RDS)은 일차적으로 폐포의 완전한 확장을 위해 필요한 계면활성물질(surfactant)의 부족, 미발달된 심폐기능에 의한 병리적 현상으로 저체중아의 가장 큰 원인이 되어왔다. RDS로 인해 인공호흡기에 의존해 있는 저체중아의 경우 적절한 산소공급과 이를 위한 호흡의 유지는 치료의 가장 큰 핵심이 되며, 이를 위한 기관내 흑은 비인두 흡인 (nasopharyngeal suction)은 신생아 중환자실(NICU)의 가장 중요한 간호행위가 되어왔다. 인공호흡기를 위한 기관삽관은 그 자체가 기도의 성모운동을 방해하고 기침반사를 억제시켜 폐 분비물의 효과적 배출을 억제하며, 특히 저체중아의 경우 조산과 관련하여 미발달된 흥곽운등과 심폐기능은 폐분비물의 이동을 저해하는 요소이다. 따라서 기도내의 분비물의 이동을 효과적으로 하여 흡인 시에 최대한의 효과를 돕기 위해 흥곽 물리요법(chest physiotheraphy : CPT)의 한 형태인 흉곽진동법 (Chest Vibration : CV)가 행해져 왔다. 그러나 저체중아를 위한CV의 임상적 적용은 그 대상의 생리적 특성, CV의 적용부위(site)와 기간(duration)에 대한 과학적 근거 없이 만성감염이나 폐질환을 가진 성인이나 cystic fibrosis환자를 위한 CV protocol을 무분별하게 채택하여 저체중아에게 행하여져 왔다 이에 본 연구자는 저체중아에 대한 CV의 안전성을 평가하고, 이에 기초하여 저체중아에게 바람직한CV의 형태를 알아보고자 본 연구를 시작하였다. 연구설계는 CV의 안전성을 평가하기 위한 실험연구이다. CV의 안전성은 RDS치료의 가장 일차적 목표인 oxygenation변화에 의해 평가될 수 있으므로, 본 실험 연구에서는 Pulse oximeter에 의해 계속적으로 측정된 산소포화 변화(oxygen saturation change)를 측정하였다. 실험대상은 미국동부에 위치한 대학병원의 NICU에 입원하여 RDS와 관련된 호흡장애로 인공호흡기에 의존해 있는 10명의 저체중아였다. 인공호흡기에 의존된 모든 저체중아는 Pulse oximeter와 심폐기능 측정기(cardiopulmonary monitor)에 의해 산소공급과 호흡상태가 계속 측정되고 있었다. 실험대상의 평균 출생시 몸무게는 평균 1,3050gm(SD=580.6)이었고, 임신월령 은 평균 28.6주(SD=3.1)였다. RDS가 그들의 일차적 진단명이었고, 그중 4명은 pneumonia, atelectasis의 합병증을 가지고 있었다. 10명중 6명은 intermittent mandatory ventilation(IMV)의 형태로, 4명은 continuous positive airway pressure(CPAP)의 형태로 인공호흡기에 의존되어 있었고 CV시의 FiO2는 평균 42.3(SD=21.2)였다. CV는 중환아용 소형진동기 (minivibrator)를 이용해 가각 10명 의 간호사에 의해 행하여 졌고, 최소 22초에서 최대 100초 동안 실시되었다. 50%의 간호사는 30초에서 40초간 CV를 실시하였으며, CV의 적용부위도, 전후 흉곽부위, 혹은 병변이 있는 좌 우측, 흑은 양쪽 흉벽 등으로 다양했고, 적용방법도 원형으로 돌려가며(circular motion), 혹은 아래에서 위로, 혹은 아무런 기준없이 간호사의 기호에 따라 다양하게 적용되었다. 산소포화의 변화는 CV가 행해지기 전.후로 5초동안 관찰되었다. 연구의 결과, 산소포화 변화는 비 모수통계(non parametric statistics)의 일종인 Matched Paired Wilcoxon test로 분석 한 결과 CV후에 3%의 감소를 보였다(P<.05). 저체중아에 있어 산소포화의 3%감소는 임상적으로 중요한 의미가 없다고 사료되어지며, 실제 흡인전의 과도호흡에 의해 CV를 행하기 이전의 산소공급수준으로 돌아 왔다. CV실시 기간과 산소포화와의 상관관계는 비 모수통계인 Spearman rho correlation coefficient를 이용하여 분석하였는데, 이 두 변수는 서로 관계가 없는 것으로 나타났다(P>.05) 또한 CV와 흡인 후에 각각의 간호사들에게 CV를 필요로 한 저체중아의 기준, 적용부위, 기간, 방법등에 대한 기준을 물었으나 대상의 특성에 따른 간호사정에 의존하기보다는 간호사 각자의 선호하는 방법이나 습관에 라 행하는 것으로 나타났다. 결론적으로 CV와 산소포화 변화와의 관계, NICU에서 관찰된 CV의 임상적 적용을 기초로 저체중아에게 안전한 CV protocol은 신생아용 소형 진동기를 이용하여, 양쪽 흉곽의 늑골하측 변연 부위(low lateral costal margin)에서 시작하여 흉골 중앙부위 방향으로 30초 동안 진동기를 적용하는 것이 좋은 것으로 나타났다. 이에 CV의 효과를 평가하기 위한 보다 과학적인 접근방법으로, CV와 흡인의 결과인 가래(sputum)에 대한 연구를 제언하는 바이다.

  • PDF

Influence of tungsten carbide/carbon coating of implant-abutment screw on screw loosening (임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이나사풀림에 미치는 영향)

  • Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.137-147
    • /
    • 2008
  • Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.