• Title/Summary/Keyword: Mechanical Stimulation

Search Result 194, Processing Time 0.03 seconds

Effect of nitroglycerin on isolated rabbit cardiac muscle and coronary strip (적출심근 및 관상동맥에 대한 Nitroglycerin 의 작용)

  • Hong, Jang-Su;Seo, Gyeong-Pil;Kim, Gi-Hwan
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.272-280
    • /
    • 1983
  • With respect to controversial opinions concerning the nitroglycerin effects on cardiac muscle the direct nitroglycerin actions were thoroughly studied in isolated papillary muscles, atrial preparations and coronary strips of rabbits. Isometric active tension of papillary muscles developed at $35^{\circ}C$ upon electric stimulation at a rate of 60/min, was not affected by nitroglycerin up to a concentration of 10mg/L Higher concentrations of nitroglycerin, however, reduced action tension progressively. This depression of mechanical activity is accompanied by a decrease in oxygen consumption as measured by means of a flow respirometer. Resting oxygen uptake, on the other hand, remained unchanged. Similarly active tension of spontaneously beating atrial preparations also declined at a nitroglycerin concentration of more than 10 mg/L, whereas the sinus frequency did not change up to 40 mg/L. In contrast, rabbit coronary strips are much more sensitive to nitroglycerin and relax in a range of 10-100 ug/L of nitroglycerin concentration. The results indicate that the pharmacologic effects of nitroglycerin in coronary disease are due to vascular actions, because the plasma levels of nitroglycerin attainable in human therapy are not sufficiently high to directly influence the myocardium.

  • PDF

Stretch Reflex Induced Resting Tremor(SRIRT) (신전반사에 의해 유발된 휴지기성 진전 1예)

  • Kim, Ji-Sung;Seo, Man-Wook;Shin, Byoung-Soo;Kim, Young-Hyun
    • Annals of Clinical Neurophysiology
    • /
    • v.3 no.2
    • /
    • pp.168-171
    • /
    • 2001
  • It has been said that variable anatomical structures and neural circuits are related to the generation of tremor. There are cerebral cortex, thalamus, basal ganglia, inferior olivary nucleus, midbrain tegmentum, stretch reflex, and musculoskeletal structures. The stretch reflex is related with the physiologic tremor and various peripherally originated tremors. We experienced a case with the post-stroke resting tremor which was induced and aggravated by mechanical stretching stimulation. In the present case, stretch reflex has a major role in the generation and exacerbation of tremor. It is presumed that the development of tremor is attributed to the increased rhythmicity of ventral intermedius nucleus of thalamus. The enhancement of thalamic rhythmicity may be due to the increasement of long latency reflex by post-stroke rigidity. This case suggests that stretch reflex may have a major role in the pathophysiologic mechanisms of a certain centrally originated tremor.

  • PDF

Characterization of 3D Printed Re-entrant Strips Using Shape Memory Thermoplastic Polyurethane with Various Infill Density (채우기 밀도별 형상 기억 TPU 3D 프린팅 Re-entrant 스트립의 특성 분석)

  • Imjoo Jung;Sunhee Lee
    • Fashion & Textile Research Journal
    • /
    • v.24 no.6
    • /
    • pp.812-824
    • /
    • 2022
  • This study proposes to develop a 3D printed re-entrant(RE) strip by shape memory thermoplastic polyurethane that can be deformed and recovered by thermal stimulation. The most suitable 3D printing infill density condition and temperature condition during shape recovery for mechanical behavior were confirmed. As the poisson's ratio indicated, the higher the recovery temperature, the closer the poisson's ratio to zero and the better the auxetic properties. After recovery testing for five minutes, it appeared that the shape recovery ratio was the highest at 70℃. The temperature range when the shape recovery ratio appeared to be more than 90% was a recovery temperature of more than 50℃ and 60℃ when deformed under a constant load of 100 gf and 300 gf, respectively. This indicated that further deformation occurred after maximum recovery when recovered at a temperature of 80℃, which is above the glass transition temperature range. As for REstrip by infill density, a shape recovery properties of 100% was superior than 50%. Additionally, as the re-entrant structure exhibited a shape recovery ratio of more than 90%, and exhibited auxetic properties. It was confirmed that the infill density condition of 100% and the temperature condition of 70℃ are suitable for REstrips for applying the actuator.

Consideration of Detection Range Test Results of Missile Approach Warning Equipment using UAV (UAV를 활용한 미사일접근경보 장비의 탐지거리 시험결과 고찰)

  • Byeongheon Lee;Jaeeon Kwon;Youngil Kim;Sungil Lee;Cheong Lee;Jangwook Hur
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.213-221
    • /
    • 2024
  • Aircraft's operational effectiveness is reduced due to threats from enemy anti-aircraft weapons, which is a weak point. In particular, guided missiles, which pose a threat to aircraft, are rapidly developing due to technological advancements in seekers, and are classified as one of the important technologies in weapon systems. Missile approach warning equipment installed to ensure aircraft survivability detects guided missiles and provides relevant information to respond. Tests were conducted domestically to verify the detection level of missile approach warning equipment, and test results were presented under various test conditions.

The Effects of Mechanical Stimulation using Graston on Changing Trigger Point Pressure Pain Threshold and Muscle Tone of the Same Spinal Segment in Neck Disk Patient (목 디스크 환자에게 그라스톤을 이용한 기계적 자극 시 동일 척수 분절의 통증 유발점 압통 역치 및 근 긴장도에 미치는 영향)

  • Kim, Do-Hyung;Lee, Byoung-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.10
    • /
    • pp.198-205
    • /
    • 2019
  • The purpose of this study was to identify whether cutaneous sensory (CS) changes induced by mechanical intervention(MI) increases the trigger point threshold and muscle tone of the same spinal segment to neck disc patients. Thirty persons with Neck disc patients were recruited in this experiment. The subjects consisted of 10 men and 20 women. The mechanical stimulus group induced CS changes for 5 minutes using the Graston instrument and the control group received no action. The CS changes were estimated by using the Von Frey Filament, PPT changes were measured by using the pressure threshold meter and msucle tone changes were measured by using Myotone pro. CS threshold increased significantly when MI was applied (p<0.05). On the same spinal segment, increases in the right infraspinatus PPT and muscle tone was observed (p<0.05) and decreases in the right trapezius PPT was observed(p<0.05). However, the PPT and muscle tone changes in other muscles were not significantly different. Furthermore, the control group CS, PPT and muscle tone were not significantly different. As a result, CS changes induced by MI make to change PPT and muscle tone on the same spinal segment. Therefore, application of MI to the same spinal segment may be of clinical significance as a new rehabilitation method for increasing pain threshold, muscle tone and pain control in neck disc patients.

Enhanced Transdermal Delivery of Procaine Hydrochloride by lontophoresis -Comparison of Synergic Effect of High Voltage Current and Ultrasound- (이온도입에 의한 염산프로카인의 경피전달 증대 -고전압전류 및 초음파 병행의 상승효과 비교-)

  • Lee, Jong-Sook;Kim, Kyoung-Won;Lee, Jae-Hyoung;Choi, Yeong-Wook;Lee, Jae-Hwi
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.185-192
    • /
    • 2006
  • The purpose of this study was to determine the effects of iontophoresis on transdermal delivery of procaine hydrochloride in healthy volunteers, as well as to the synergic effect of high voltage current or ultrasound on the efficacy of transdermal delivery of iontophoresis. Forty healthy volunteers were randomly assigned to four groups topical application group (TA), iontophoresis group (IT), pre-treatment of high voltage current stimulation with iontophoresis (HVS + IT), and pre-treatment of ultrasound application with iontophoresis (US + IT). All subjects received procaine iontophoresis on the forearm using direct current with 4 mA f3r 15 minutes. All subject was measured the duration of local anesthesia, pressure pain threshold, pain perception threshold using rectangular wave at 0.2 ms, 1 ms, 50 ms of rectangular current stimulation after procaine iontophoresis. For comparisons of the sensory characteristics and efficacy of iontophoresis between the groups, an one-way ANOVA and Kruskal-Wallis were used. The significant difference the duration of local anesthesia were found between the groups (p<0.001). The local anesthetic duration of IT, HVS+IT were significantly longer than TA. Meanwhile, the local anesthetic duration of US+IT was significantly longer than HVS+IT, IT and TA group (p<0.05). Also, the pressure pain threshold, pain perception threshold at 0.2 ms, 1 ms, 50 ms were significant difference between the groups (p<0.001). All sensory characteristics including pressure pain threshold, pain perception threshold of IT, HVS+IT was significantly increased than TA, whereas, US+1T was significantly increased HVS+1T, IT and TA (p<0.05). This study showed that the procaine iontophoresis have increase the duration of local anesthesia concomitantly pressure pain threshold and pain perception threshold of sensory nerve fibers such as $A-{\beta}$, $A-{\delta}$ and C fiber. This findings suggest that the iontophoresis enhanced the transdermal delivery of drug ions in vivo. The combination of ultrasound application and iontophoresis synergized the transdermal delivery of drug ions. It is suggests that an electric field, mechanical and heating property of ultrasound may contribute to synergic effect due to temporary changes of structure in the stratum corneum.

MR Technology to 4T

  • Vaughan, Thomas
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.103-105
    • /
    • 2003
  • After fifteen years of development, Magnetic Resonance (MR) technology for human imaging and spectroscopy is reaching a refined state with FDA approved 3T clinical products from Siemens, GE, and Philips. Broker has cleared CE approval with a 4T system. Varian supports a 4T system platform as well. Shielded magnets are standard at 3T from GE, Oxford, Magnex, and IGC. A shielded 4T whole body magnet is available from Oxford. Stronger switched gradients and dynamic shim coils, desired at any field, areespecially useful at higher static magnetic fields B0. In addition to the higher currents required for higher resolution slice or volume selection afforded by higher SNR, whole body gradient coils will be driven at increasing slew rates to meet the needs of new cardiac applications and other requirements. For example 3T and 4T systems are now being equipped with 2kV, 500A gradient coils and amplifiers capable of generating 4G/cm in 200msec, over a 67+/-cm bore diameter. High field EPI applications require oscillation rates at 1 kHz and higher. To achieve a benchmark 0.2 ppm shim over a 30cm sphere in a high field magnet, at least four stages of shimming need to be considered. 1) A good high field magnet will be built to a homogeneity spec. falling in the range of 100 to 150 ppm over this 30cm spherical "sweet spot" 2) Most modern high field magnets will also have superconducting shim coils capable of finding 1.5 ppm by their adjustment during system installation. 3) Passive ferro-magnetic shimming combined with 4) active, high order room temperature shim coils (as many as five orders are now being recommended) will accomplish 0.2 ppm over the 30cm sphere, and 0.1 ppm over a human brain in even the highest field magnets for human studies. Safety concerns for strong, fast gradients at any B0 field include acoustic noise and peripheral nerve stimulation. One or more of the mechanical decoupling methods may lead to quieter gradients. Patient positioning relative to asymmetric or short gradient coils may limit peripheral nerve stimulation at higher slew rates. Gradient designs combining a short coil for local speed and strength with a longer coil for coverage are being developed for 3T systems. Local gradients give another approach to maximizing performance over a limited region while keeping within the physiologically imposed dB0/dt performance limits.

  • PDF

Evaluation of Electric Pulp Test (EPT) as a Tool for Measurement of Dentinal Hypersensitivity (상아질 지각과민 측정 도구로서의 전기치수검사에 대한 평가)

  • Kim, Young-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.371-378
    • /
    • 2002
  • In this study, 40 hypersensitive teeth of 19 patients were investigated. The procedures performed were as follows: Before desensitization, EPT at occlusal third of buccal surface was done for the evaluation of pulp vitality and the EPT value was recorded for the reference value. And mechanical and thermal test was executed for the test of hypersensitivity. If the tooth responded to the above tests, we did EPT at the exposed surface, using toothpaste as a electrolite medium and recorded the EPT value at patient's response. After the tests had been done, desensitization procedures with Gluma(R) Desensitizer were performed according to the manufacturer's instructions. After desensitization, the same tests except EPT at occlusal third were repeated. All the 40 teeth responded positive before desensitization and negative after desensitization procedures. The EPT value at occlusal third ranged from 31 to 65 (48.9${\pm}$7.2). Before desensitization 34 teeth responded at EPT value of 2 and the remaining 6 teeth was in the range of 17 to 25. After desensitization all 40 teeth responded from 12 to 27 (19.6${\pm}$3.5). The 6 teeth responded at greater number than 2 before desensitization was in the range of 18 to 23. Within the limitations of this study we can conclude that: When a tooth with dentinal hypersensitivity responds to mechanical and thermal stimulation, the tooth shows very low resistance to electricity at the exposed surface while when a tooth is desensitized and doesn't show respond to mechanical and thermal stimuli, the tooth shows increased level of resistance to electric stimulation at the exposed surface. EPT can be used for the diagnosis of dentinal hypersensitivity. Furthermore EPT will be useful to evaluate the outcome of desensitization procedures. However, EPT is not a valid tool for measuring dentinal hypersensitivity.

Effects of Radix Aconiti Herbal Acupuncture Injected at Hwando($GB_{30}$) on Neuropathic Pain in Rats (환도(環跳)($GB_{30}$) 초오약침(草烏藥鍼)이 L5 척수신경 결찰에 의한 흰쥐의 동통모델에 미치는 영향)

  • Bang, Sung-Pil;Ryu, Mi-Seon;Kim, Jae-Hong;Wei, Tung-Sheun;Yun, Dae-Hwan;Yun, Yeo-Choong;Yeo, Kyeong-Chan;Jung, Ho-Seok
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.67-76
    • /
    • 2009
  • Objectives : The purpose of this study is to examine if Radix Aconiti herbal acupuncture may be effective to the neuropathic pain(mechanical allodynia, cold allodynia) in a rat model of neuropathic pain. Methods : To produce the model of neuropathic pain, under isoflurane 2.5% anesthesia, L5 spinal nerve was ligated by 6-0 silk thread. After neurophathic surgery, the author examined if the animals exhibited the behavioral sign of allodynia. The allodynia was assessed by stimulating the medial malleolus with von frey filament and acetone. Three days after the neuropathic surgery, Radix Aconiti herbal acupuncture was injected at Hwando($GB_{30}$) one time per two days for 2 weeks. After that, the author examined the withdrawal response of neuropathic rats' legs by von frey filament and acetone stimulation. And also the author examined c-Fos in the midbrain central gray of neuropathic rats and the change of WBC, RBC, HGB, HCT count in the blood of neuropathic rats. Results : The Radix Aconiti herbal acupuncture injected Hwando($GB_{30}$) decreased the withdrawal response of mechanical allodynia that assessed with von frey filament in RA1-$GB_{30}$, RA2-$GB_{30}$ group as compared with control group. The Radix Aconiti herbal acupuncture injected Hwando($GB_{30}$) decreased the withdrawal response of chemical allodynia(cold allodynia) that assessed with acetone in RA1-$GB_{30}$, RA2-$GB_{30}$ group as compared with control group. The Radix Aconiti herbal acupuncture injected Hwando($GB_{30}$) showed the significant between control group and RA2-$GB_{30}$ group in the c-Fos expression. The Radix Aconiti herbal acupuncture injected Hwando($GB_{30}$) did not show the significant between control group and RA1-$GB_{30}$ group, RA2-$GB_{30}$ group and RA3-$GB_{30}$ group in the WBC, RBC, HGB, HCT count. Conclusions : We have noticed that Radix Aconiti herbal acupuncture at Hwando($GB_{30}$) decreased mechanical allodynia and cold allodynia in the model of neuropathic pain compared with the control group. C-fos expression in the central gray of that group was also decreased compared with the control group. This study can be used as a basic resource on a study and a treatment of pain.

  • PDF

Effects of Bee Venom Acupuncture Injected at Hwando(GB30) on Neuropathic Pain in Rats (환도혈(GB30) 봉독 약침 자극이 백서의 신경병리성 동통 억제에 미치는 영향)

  • Youn, Dae-Hwan;Na, Chang-Su;Yoon, Yeo-Choong;Lee, Dong-Hyun
    • Journal of Acupuncture Research
    • /
    • v.22 no.5
    • /
    • pp.67-77
    • /
    • 2005
  • Objectives : The purpose of this study is to examine if Bee Venom Acupuncture may be effective to the neuropathic pain(mechanical allodynia, cold allodynia) in a rat model of neuropathic pain. Methods : To produce the model of neuropathic pain, under isoflurane 2.5% anesthesia, tibial nerve and sural nerve was resected. After the neuropathic surgery, the author examined if the animals exhibited the behavioral signs of alloynia. The allodynia was assessed by stimulating the medial malleolus with von Frey filament and acetone. Three weeks after the neuropathic surgery, Bee Venom Acupuncture was injected at Hwando(GB30) one time a day for one week. After that, the author examined the withdrawl response of neuropathic rats' legs by yon Frey filament and acetone stimulation. And also the author examined c-Fos in the midbrain central gray of neuropathic rats and the change of WBC count in the blood of neuropathic rats. Results : The Bee Venom Acupuncture injected Hwando(GB30) decreased the withdrawl response of mechanical allodynia in BV-2, BV-3 group as compared with control group. The Bee Venom Acupuncture injected Hwando(GB30) decreased the withdrawl response of chemical allodynia(cold allodynia) in BV-2, BV-3 group as compared with control group. The Bee Venom Acupuncture injected Hwando(GB30) showed the significant difference between control group and BV-2 group, control group and BV-3 group in the c-Fos expression and U count. Conclusion : We have noticed that Bee Venom Acupuncture at Hwando(GB30) decreased mechanical allodynia and cold allodynia in the model of neuropathic pain compared with the control group. C-Fos expression in the central gray of that group was also decreased compared with the control group. Psin control using Bee Venom Acupuncture was accumulated as time goes by. This study can be used as a basic resource on a study and a treatment of pain.

  • PDF