• Title/Summary/Keyword: Measuring methods

Search Result 4,472, Processing Time 0.03 seconds

Efficiency of ceramic bracket debonding with the Er:YAG laser (세라믹 브라켓의 제거 시 Er:YAG 레이저의 효능)

  • Suh, Chung-Hwan;Chang, Na-Young;Chae, Jong-Moon;Cho, Jin-Hyoung;Kim, Sang-Cheol;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.213-224
    • /
    • 2009
  • Objective: The aim of this study was to find out whether Er:YAG laser can aid in debonding ceramic brackets, and to see what kind of method will be the most appropriate for debonding. Methods: One hundred and ninety teeth, monocrystalline brackets ($MISO^{TM}$, HT, Ansan-Si, Korea), polycrystalline brackets ($Transcend^{TM}$ series 6000, 3M Untek, Monrovia, CA, USA) and the KEY Laser3 (KavoDental, Biberach, Germany) were used. Experimental groups were classified according to the type of ceramic brackets, and the amount of laser energy (0, 140, 300, 450, 600 mJ). After applying laser on the bracket at two points at 1 pulse each, the shear bond strength was measured. The effect of heat caused by laser was measured at the enamel beneath the bracket and pulp chamber. After measuring the shear bond strength, adhesive residue was evaluated and enamel surface was investigated using SEM. Results: All ceramic bracket groups showed a significant decrease in shear bond strength as the laser energy increased. The greatest average temperature change was $3.78^{\circ}C$ on the enamel beneath the bracket and $0.9^{\circ}C$ on the pulp chamber. Through SEM, crater shape holes caused by the laser was seen on the enamel and adhesive surfaces. Conclusions: If laser is applied on ceramic brackets for debonding, 300 - 450 mJ of laser energy will be safe and efficient for monocrystalline brackets ($MISO^{TM}$), and about 450 mJ for polycrystalline brackets ($Transcend^{TM}$ series 6000).

Assessment type and gender differences in science achievement (평가 방법에 따른 과학 성취도에서의 성 차이)

  • Shin, Dong-Hee;Kim, Dong-Young
    • Journal of The Korean Association For Science Education
    • /
    • v.23 no.3
    • /
    • pp.265-275
    • /
    • 2003
  • The purpose of this study is to investigate the differences of science achievement between female- and male students in different assessment types, expecting the reconsideration of their scientific ability. to accomplish this purpose, the school science achievement score of 1,487 female- and male students in 2000 were analyzed from the perspectives of assessment methods and gender differences, achievement level and gender differences, and gender characteristics in correlation between each assessment type and total science score. The science achievement score in this study includes mi-term and final paper-and-pencil test in two semesters and performance assessment. The results are as follows. First, in the total science achievement score, whereas female students achieved significantly better than male counterparts in the 7th grade, there was no significant difference between two genders in the 8th and 9th grades. Second, as for the close-ended items, all students, regardless of their gender and grade, showed no significant difference. As for the open-ended items, whereas female students achieved significantly better than male counterparts in the 7th grade, there was no significant difference between gender in the 8th and 9th grades. As for the performance assessment, all female students, regardless of their achievement level, achieved significant better than male counterparts, which is very noteworthy. Third, in the uppermost achievement level, there was no significant difference not only in close- and open ended items but also in performance assessment. Fourth, male students' correlation between performance assessment and total science score was relatively higher than female students'. The result of this study, that female students did significantly better than male students in performance assessment, is interesting in that performance assessment is widely accepted as more reliable and valid method in measuring students' various ability than traditional paper-and-pencil test.

Effect of titanium powder on the bond strength of metal heat treatment (티타늄 파우더가 금속의 열처리 시 결합강도에 미치는 영향)

  • Kim, Sa-Hak;Kim, Wook-Tae
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.71-79
    • /
    • 2017
  • Purpose: Ni-Cr alloy does not contain Beryllium, causing the metal compound to form oxides in the furnace but by using Titanium as a chemical catalyst the forming of the oxides can be controlled, and by controlling the impurities formed on the metal surface, the possibility of the Ni-Cr alloy bond strength being increased can be analysed. Materials and Methods: Titanium was used as a chemical catalyst in the porcelain for the oxidation of beryllium-free metal (Ni-Cr) alloy. The T1 group, which does not use Titanium power as a chemical catalyst is a reference model for comparison. The T2 group and T3 group used 10 g and 20 g of Titanium power, respectively. They are fabricated to observe the shear bond strength and surface properties. There was no significance when One-way ANOVA analysis/Tukey Honestly Significant Difference Test was conducted for statistical analysis among groups (P > 0.05). Results: Results of measuring the three-point flexural bond strength of the Ni-Cr alloy and thickness of the oxide film. Experiment T3 using 20 g Titanium chemical catalyst: $39.22{\pm}3.41MPa$ and $6.66{\mu}m$, having the highest bond strength and thinness of oxide film. Experiment T2 using 10 g Titanium chemical catalyst: $34.65{\pm}1.39MPa$ and $13.22{\mu}m$. Experiment T1 using no Titanium chemical catalyst: $32.37{\pm}1.91MPa$ and $22.22{\mu}m$. Conclusion: The T2 and T3 experiments using Titanium chemical catalyst showed higher bond strength for the Ni-Cr alloy and lower thickness of oxide film than experiment T1, and the titanium catalyst being able to increase bond strength was observed.

A Polarization-based Frequency Scanning Interferometer and the Measurement Processing Acceleration based on Parallel Programing (편광 기반 주파수 스캐닝 간섭 시스템 및 병렬 프로그래밍 기반 측정 고속화)

  • Lee, Seung Hyun;Kim, Min Young
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.8
    • /
    • pp.253-263
    • /
    • 2013
  • Frequency Scanning Interferometry(FSI) system, one of the most promising optical surface measurement techniques, generally results in superior optical performance comparing with other 3-dimensional measuring methods as its hardware structure is fixed in operation and only the light frequency is scanned in a specific spectral band without vertical scanning of the target surface or the objective lens. FSI system collects a set of images of interference fringe by changing the frequency of light source. After that, it transforms intensity data of acquired image into frequency information, and calculates the height profile of target objects with the help of frequency analysis based on Fast Fourier Transform(FFT). However, it still suffers from optical noise on target surfaces and relatively long processing time due to the number of images acquired in frequency scanning phase. 1) a Polarization-based Frequency Scanning Interferometry(PFSI) is proposed for optical noise robustness. It consists of tunable laser for light source, ${\lambda}/4$ plate in front of reference mirror, ${\lambda}/4$ plate in front of target object, polarizing beam splitter, polarizer in front of image sensor, polarizer in front of the fiber coupled light source, ${\lambda}/2$ plate between PBS and polarizer of the light source. Using the proposed system, we can solve the problem of fringe image with low contrast by using polarization technique. Also, we can control light distribution of object beam and reference beam. 2) the signal processing acceleration method is proposed for PFSI, based on parallel processing architecture, which consists of parallel processing hardware and software such as Graphic Processing Unit(GPU) and Compute Unified Device Architecture(CUDA). As a result, the processing time reaches into tact time level of real-time processing. Finally, the proposed system is evaluated in terms of accuracy and processing speed through a series of experiment and the obtained results show the effectiveness of the proposed system and method.

The Effects of Object Size and Reaching Distance on Upper Extremity Movement (물체 크기와 뻗기 거리가 상지 움직임에 미치는 영향)

  • Bae, Su-Young;Kim, Tae-Hoon
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.10 no.1
    • /
    • pp.51-61
    • /
    • 2020
  • Objectives : The purpose of this study is to investigate the effect of object size and reaching distance on kinematic factors of the upper limb while performing arm reaching for normal subjects. Methods : The subjects of this study were 30 university students who were in D university in Busan, and the measuring tool was CMS-70P(Zebris Medizintechnik Gmbh, Germany), a three-dimensional motion analyzer. The task had six conditions. The average velocity of motion, average acceleration, maximum velocity, and the velocity definite number of movements were measured according to changes in object size(2cm, 10cm) and reaching distance(15%, 37.5%, 60%) when they performed arm reaching. The general characteristics of the subject were technical statistics. One-way ANOVA measurement was used to compare variables when the arm reaching task was performed from two object sizes to three reaching distance, and the post-test was conducted with Tukey test. In addition, an independent t-test was used to analyze the kinematic differences according to the two object sizes at three reaching distances. A two-way ANOVA measurement (3×2 Two-way ANOVA measurement) was performed to identify the interaction of the reaching distance(15%, 37.5%, 60%) and the object size(2cm, 10cm). The statistical significance level α was set to .05. Results : When the size of the object increased, the velocity and maximum velocity also increased, but the definite number of velocity decreased. When the reaching distance increased, the velocity and maximum velocity increased, whereas the definite number of velocity decreased. Conclusion : The clinical significance of this study could be utilized as the baseline data for grading object size and reaching distances when the reaching training is implemented for patients whose central nervous system was damaged.

Decrease of the Activation and Carbamylation of Rubisco by High CO2 in Kidney Bean (KidneyBean에서의 고 CO2 농도에 의한 Rubisco의 Activation과 Carbamylation의 감소)

  • 노광수;김재기
    • KSBB Journal
    • /
    • v.11 no.3
    • /
    • pp.295-302
    • /
    • 1996
  • The measurements of rubisco parameters are important in photosynthetic studies. In this experiment, we used photometric assay method to detect these major parameters, such as activity, carbamylation and amount of rubisco. The main advantages of this method are very simple and as sensitive as conventional methods which usually produce radioactive waste. In this study, with kidney bean (Phaseolus vulgatis L.) leaves grown at normal $CO_2$ (350ppm) and high $CO_2$ (650 ppm), we investigated the effect of $CO_2$ concentration on activation and carbamylation of rubisco by measuring the rubisco activity, carbamylation rate and amount of rubisco using a dual beam (334nm and 405nm) spectrophotometer, and analyzed the polypeptide profiles of rubisco by SDS-PAGE. When $CO_2$ concentration was raised from 350ppm to 650ppm, all parameters of rubisco were decreased : $41.2{\mu}M/m^2/s and 52.2{\mu}M/m^2/s$ to $27.4{\mu}M/m^2/s and 46.1{\mu}M/m^2/s$ for initial and total rubisco activity, respectively ; from 79% to 58.9% for carbamylation rate ; from $1.94 {\mu}M/m^2$ to 1.58{\mu}M/m^2$ for amount of rubisco. These results suggests that the decrease in rubisco activity at high $CO_2$ was caused by carbamylation. The analysis of the preparation by SDS-PAGE showed two major polypeptides at 50 and 14.5 kD which were identified as the large and the small subunits of rubisco. There were no differences in the intensity compared high $CO_2$ to normal $CO_2$ in both 50 kD and 14.5 kD bands. We also found that these inhibitory effects of $CO_2$ were reversible. When high $CO_2$ was switched to normal $CO_2$, the parameters of rubisco changed were almost the same as normal rubisco parameters. These data provide an evidence that activity of rubisco was recovered by $CO_2$ concentration of 350 ppm.

  • PDF

The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan (동적신장검사에서 신장깊이에 따른 사구체여과율 비교)

  • Hwang, Ju-Won;Lim, Young-Hyen;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Mu-Seok;Jung, Ji-Uk;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.73-77
    • /
    • 2014
  • Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in $^{99m}Tc$-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen $83.3{\pm}9.79mL/min$. $98.6{\pm}14.07mL/min$ GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.

  • PDF

Usefulness of Hepatocellular Carcinoma by Hepatic Arterial Perfusion Scintigraphy with $^{99m}Tc$-MAA ($^{99m}Tc$-MAA를 이용한 간세포암의 간동맥 관류 스캔의 유용성)

  • Jeong, Ji-Uk;Lee, Hyo-Yeong;Yun, Jong-Jun;Lee, Hwa-Jin;Lee, Moo-Seok;Song, Hyeon-Seok;Park, Se-Yun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.155-158
    • /
    • 2010
  • Purpose: $^{99m}Tc$-macroaggregated albumin (MAA) hepatic arterial perfusion scintigraphy was known for useful method to evaluate patients receiving intraarterial chemotherapy for liver cancer. This study evaluate about usefulness of normal liver on hepatocellular carcinoma (HCC) from HCC patients. This study is to see the usefullness of Hepatic Arterial Perfusion Scintigraphy (HAPS) by measuring mass size, shape, lung shunting and tumor to normal ratio (T/N ratio) in relative blood stream of HCC patients compared with HCC on normal liver. Materials and Methods: From June 2009 to September 2009, HAPS studies were performed on 7 patients (men 6, women 1, mean 64) who were diagnosed HCC. HAPS was performed after proper hepatic artery $^{99m}Tc$-MAA of 5 mCi (185 MBq) injection by catheter. We performed anterior, posterior, both lateral view, SPECT of chest and abdomen. Then we set up ROI and calculated lung shunting, T/N ratio for each count, count/pixel (mean value). Results: Tumor and liver size analyzed by ROI of anterior, posterior view are 2.0-10.8 cm (mean 3.75 cm), 8.8-18.5 cm (mean 14.6 cm). T/N ratio analyzed by total tumor and total normal mean value are 2.41-5.76 (mean 3.8). lung shunting analyzed by total liver count is 3.14-13.92% (mean 6.77%). Conclusion: HAPS with $^{99m}Tc$-MAA can evaluate mass size, location, quantitative analysis through T/N ratio. also HAPS can evaluate detection of arteriovenous shunt through lung uptake before radioisotope therapy. Therefore HAPS with $^{99m}Tc$-MAA can be useful method in aspect of evaluation and treatment of HCC.

  • PDF

The Analysis of Blood Glucose Level Difference According to the Exact Use of Blood Glucose Measurement Test Strips in $^{18}F$-FDG Wholebody PET ($^{18}F$-FDG를 이용한 전신 PET 검사에서 혈당 측정 검사지의 정확한 사용에 따른 혈당 수치의 차이 분석)

  • Park, Soon-Ki;Lee, Nam-Ki;NamGung, Chang-Kyung;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.100-103
    • /
    • 2010
  • Purpose: $^{18}F$-FDG wholebody PET is to evaluate the tumor using glucose metabolism. The blood glucose level is important factor that affects on a result of examination. High glucose levels may interfere with tumor targeting due to competitive inhibition of FDG uptake by D-glucose. The blood glucose level measurement test strips used in the blood glucose measurement are classified into the capillary blood measurement test strips and general purpose measurement test strips that can measure the venous blood and capillary blood altogether depends on cases. The purpose of the study was to compare the blood glucose measurements between simultaneously obtained capillary and venous blood samples using the capillary blood measurement test strips, general purpose measurement test strips. Materials and Methods: A total of 46 subjects (32 males, 14 females) with a mean age of $57.3{\pm}12.3$ years were enrolled. The blood glucose estimation was performed with a Optium Xceed Glucometer (Abbott). Simultaneous capillary and venous blood samples were obtained from each subject. The blood glucose levels were measured using the capillary blood measurement test strips and general purpose measurement test strips. The capillary and venous measurements were compared using a pared t-test. Results: The mean capillary and venous glucose values using the general purpose measurement test strips were $95.2{\pm}12.4$ mg/dL and $104.1{\pm}14.4$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (9.0 mg/dL; 95% confidence interval (CI) -11.2 to -6.7). The mean capillary and venous glucose values using the capillary blood measurement test strips were $91.5{\pm}13.6$ mg/dL and $108.6{\pm}16.2$ mg/dL, giving a statistically significant difference (p<0.001) between the mean values for the capillary and venous glucose samples (16.6 mg/dL; 95% CI -20.2 to -13.0). Conclusion: When measuring the blood glucose level before $^{18}F$-FDG PET examination, since the incorrect blood glucose level can be measured, it should note to measure the blood glucose level of the venous blood by the capillary blood measurement test strips. Therefore the measurement variation can be reduced to fulfill the standardized measurement procedure with the suitable measurement test strips, the preparation of the PET examination will be able to be clearly confirmed. In addition, the standardized procedure of the following measurement on the area which is same at all times the blood area in the blood glucose measurement among a capillary or a vein will be needed.

  • PDF

A Study on the Optimization Methods of Security Risk Analysis and Management (경비위험 분석 및 관리의 최적화 방안에 관한 연구)

  • Lee, Doo-Suck
    • Korean Security Journal
    • /
    • no.10
    • /
    • pp.189-213
    • /
    • 2005
  • Risk management should be controlled systematically by effectively evaluating and suggesting countermeasures against the various risks which are followed by the change of the society and environment. These days, enterprise risk management became a new trend in the field. The first step in risk analysis is to recognize the risk factors, that is to verify the vulnerabilities of loss in the security facilities. The second step is to consider the probability of loss in assessing the risk factors. And the third step is to evaluate the criticality of loss. The security manager will determine the assessment grades and then the risk levels of each risk factor, on the basis of the result of risk analysis which includes the assessment of vulnerability, the provability of loss and the criticality. It is of great importance to put the result of risk analysis in mathematical statement for a scientific approach to risk management. Using the risk levels gained from the risk analysis, the security manager can develop a comprehensive and supplementary security plan. In planning the risk management measures to prepare against and minimize the loss, insurance is one of the best loss-prevention programs. However, insurance in and of itself is no longer able to meet the security challenges faced by major corporations. The security manager have to consider the cost-effectiveness, to suggest the productive risk management alternatives by using the security files which contains every information about the security matters. Also he/she have to reinforce the company regulations on security and safety, and to execute education repeatedly on security and risk management. Risk management makes the most efficient before-the-loss arrangement for and after-the-loss continuation of a business. So it is very much important to suggest a best cost-effective and realistic alternatives for optimizing risk management above all, and this function should by maintained and developed continuously and repeatedly.

  • PDF