• 제목/요약/키워드: Measuring Tip

Search Result 212, Processing Time 0.027 seconds

The Effect of the ETC(Electronic Throttle Control) Characteristics on the Vehicle Driveability at Tip-in/out (스로틀 전자제어 방식에서 제어 특성이 차량의 가/감속 시 운전성에 미치는 영향)

  • Park, Kyoung-Seok;Lee, Jong-Hwa;Park, Jin-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.113-119
    • /
    • 2005
  • The passenger car drivers want in general to feel good driveability, but they sometimes feel uncomfortable by shock and jerk phenomenon when they push or release acceleration pedal with clutch engaged. In this paper, the shock and jerk characteristics are studied on the vehicles of the throttle-by-wire system. With this system, the throttle is not directly controlled by drivers but via a microprocessor. So the control logic of the throttle is very important on tip-in and tip-out driveability. Experiments were carried out on two vehicles which show different control characteristics. The torque control logics were analyzed by measuring cylinder pressures. The results show that special torque control logic is needed at tip-in/out state for good driveability.

Comparison of oxygen saturation between no polish nails and self-artificial nails using portable pulse oximeter (휴대용 맥박산소포화도 측정기를 이용한 맨손톱과 셀프 인조손톱의 산소포화도 비교)

  • Su-Min Kim;Kyoung-Youl Lee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2024
  • Purpose: This study aimed to compare the oxygen saturation measured at fingertips with unpolished and self-artificial nails (sticker, tip) using a portable pulse oximeter. Methods: The sample comprised 27 women who had used nail care services. Using a pulse oximeter, oxygen saturation was measured at fingertips with unpolished nails in a stable state. Self-fabricated sticker and tip nails were attached to the right and left hands, respectively, using five nail colors (black, blue, green, purple, and brown). Oxygen saturation was measured at fingertips with self-fabricated nails first in the usual manner and then measured again by rotating the oximeter by 90°. Values of oxygen saturation were compared and analyzed using the Friedman test and Wilcoxon signed-rank test with Bonferroni correction using IBM SPSS 26.0. Results: Oxygen saturation values were significantly different among colors for both sticker nails (p=.036) and tip nails (p=.000), with black self-artificial nails tending to demonstrate lower oxygen saturation. Moreover, oxygen saturation values obtained by measuring the usual way on unpolished nails was significantly different than those obtained by rotating the oximeter by 90° on thumb with sticker (p=.001) and tip nails (p=.001). Conclusion: The findings of this study suggest that oxygen saturation should be measured on other fingers except for thumb instead of removing the self-artificial nails in emergency situations. For patients with black self-artificial nails, is the findings recommend measuring oxygen saturation at other body parts such as toes, earlobes, forehead, etc.

Study on Dynamic Characteristics and Performance of Tip Jet Rotor Using Small-scaled Rotor (축소로터를 이용한 Tip Jet 로터의 성능 및 동특성 연구)

  • Kwon, Jae Ryong;Baek, Sang Min;Rhee, Wook;Lee, Jae Ha
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.2
    • /
    • pp.30-36
    • /
    • 2018
  • In this study, a small-scaled test system for a tip jet rotor was developed to contribute to the research on unmanned compound rotorcraft. The performance and dynamic characteristics of the tip jet rotor were investigated using the test system. The diameter of the tip jet rotor was set to 2m in consideration of the size of the test site and the pneumatic supply capacity of the. The rotating speed of the rotor was controlled by the pressure of the compressed air. The thrust and forces during the rotor rotation were measured using a load measuring device. A hydraulic actuator was installed for the dynamic test and full-bridge strain gages were attached to the root of each blade to measure the flap, lag, and torsion-wise responses generated when the rotor is excited by the actuator. The performance and dynamic characteristic tests were conducted at various rotor speeds and blade pitches. In order to check the validity of the test results, the results were also compared with the CAMRAD II analysis.

A Study on the Semi-conductor Package Process Epoxy Moulding Compound Gun (반도체 Package 공정용 EMC Gun에 관한 연구)

  • Cho, Myung-Hyun;Kim, Gyu-Sung
    • 전자공학회논문지 IE
    • /
    • v.43 no.4
    • /
    • pp.83-92
    • /
    • 2006
  • EMC(epoxy moulding compound) when operate with residual quantity processing after fixed quantity moulding inverse close way of designing by mechanical action inhalation so that may occur, solved of needle tip residual quantity and cause of thread extend phenomenon. In this paper, design to connect directly gun, washer tank and measuring beforehand amount that washing is easy and want minuteness fixed quantity that essential equipment in semi-conductor packaging process because develop EMC so that can molding with high speed consider.

The friction characteristics at vane tip of vane pump for power steering system (Power Steering용 베인 펌프의 베인 선단부에서의 마찰특성)

  • 박운성;정석훈;오석형;정재연
    • Tribology and Lubricants
    • /
    • v.11 no.3
    • /
    • pp.48-53
    • /
    • 1995
  • In this paper, the friction characteristics of contact region between vane tip and camring is studied using a modeled experimental device. The contact region is under the influence of variable loads with the amplitude of hundreds of Newton and frequency of tens of Hz. The condition of lubrication between vane and disk is modeled after the actual condition between vane and camring. The coefficient of friction is obtained by measuring the frictional forces in the contact region between camring and vane. The friction characteristics of the actual oil hydraulic vane pump is estimated on the basis of coefficient of friction. The analysis of frictional characteristics shows us that the lubrication condition of vane tip is that of transition regime between hydrodynamic lubrication and mixed lubrication.

Effect of wear of Contact Tips to Welding Consumable for Gas Metal Arc Welding (가스메탈아크용접에서 콘택트팁의 마모에 미치는 용접재료의 영향)

  • Kim, In-Gyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.860-864
    • /
    • 2012
  • The contact tip is higher the wear of resistance and the longer life are demanded to GMA welding process. In this study, four different contact tips with three different compositions by two wires were evaluated their wear resistance by measuring in every one hour the area of enlarged hole at the exit side during actual wleding. Experimental results clearly showed that the Cr-containing tips strengthened by precipitation hardening have much better resistance to wear than those made by work hardening. In addition, flux cored wire is excellent abrasion resistance test results showed. Based on these results, the domestic industry, the life of the contact tip to know will be used as basic data.

A Study of Data Storage Device Utilizing AFM technology (AFM을 이용한 데이터 저장 소자 연구)

  • Choi Jung-Hwan;Park Kun-Hyung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.5
    • /
    • pp.411-416
    • /
    • 2006
  • A new reading technology for the ultra-high density data storage device utilizing AFM technology was proposed and its experimental results were discussed in this paper. For the experiments, an about $2{\mu}m$ thick conductive polymer layer was spin-coated on the heavily doped n-type Si wafer and an about $0.1{\mu}m$ thick PMMA layer was also been spin-coated on it. After then, the $5{\times}5$ memory way was fabricated by making indents on the surface of the wafer with the heated AFM tip, and the data reading was performed by scanning the surface with the tip biased at 10 V and the measuring the current flowing out at the end of the tip. The experimental results clearly showed that the new data reading technology worked superbly. The current measured was about 0.92 pA at the cell with the indent, and it was not only below 0.31 pA at the cell without the indent, but also at the cell where the indent was erased.

A STUDY ON STRESS DISTRIBUTION IN IMZ IMPLANT WITH A PLASTIC OR A TITANIUM IME USING FINITE ELEMENT ANALYSIS (유한요소법을 이용한 IMZ임플란트의 플라스틱 및 티타늄 IME의 응력분포에 관한 연구)

  • Ha Chi-Yang;Choi Boo-Byung;Woo Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.625-642
    • /
    • 1993
  • Whether stress-absorbing elements are functional in an implant system has been an issue of interest in oral implantology. The unique feature of the IMZ implant system is the planned imitation of the stress-distributing function of the structural unit of the tooth, periodontium, and alveolar bone through the use of an intramobile element(IME). The purpose of this study was to compare the difference in the displacement and the stress distibutions of IMZ implant with a polyoxymethylene(POM) or a titanium IME under static load. Two dimensional finite element analysis(FEA) was applied for this study and two finite element models were created. PATRAN program(DPA Co.,USA), a software for FEA, and SUN-SPARC2GX(SUN Co., USA), a workstation computer, were used. $1Kg/mm^2$ of static load was loaded individually on each three point of crown of implant prosthesis ; central fossa(load 1), mesial cusp tip(load 2), distal cusp tip(load 3), The displacements of X- and Y-axis and total displacement were measured at mesial and distal cusp tips, mesial and distal points between crown and IME, and implant apex. The von Mises stress was measured at mesial and distal points between crown and IME, mesial and distal points between IME and TIE, mesial and distal alveolar crest, the mesial and distal midpoints of implant, and implant apex. The difference in resultant values were compared and evaluated statistically using paired t-test. The results were as follows : 1. Under the load 1, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except total and Y-axis displacement at implant apex. And the differences in stress distributions with POM and titanium were varied. 2. Under the load 2, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except X-axis displacement at distal cusp tip. And the differences in stress distributions were varied. 3. Under the load 3, all the displacement of implant with titanium IME at 5 measuring points was larger than that of with POM IME except Y-axis displacement at mesial cusp tip. And the differences in stress distributions were varied. 4. For the displacement, there was significant difference statistically only in total displacement (P<0.1), but was no significant difference in X- and Y-axis displacement(P>0.1). For the stress, there was no significant difference among the compared values.

  • PDF

Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse (맥진 깊이 판단을 위한 실시간 압력 측정기)

  • Cho, Jong Ho;Kim, Dae Bok;Kim, Gi Wang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

Estimation of Vertical Interaction Force to the End of a Surgical Instrument by Measuring Reaction Force to the Trocar Support (트로카 고정부에 작용하는 반력을 측정하여 수술도구 말단의 수직방향 상호작용 힘을 추정하는 방법)

  • Kim, Suyong;Kim, Cheongjun;Lee, Doo Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.615-618
    • /
    • 2016
  • This paper proposes a method to estimate vertical interaction force to the end of the surgical instrument by measuring reaction force at the part supporting the trocar. Relation between the force to the trocar and the interaction force is derived using the beam theory. The vertical interaction force is modeled as a function of the reaction force to the trocar and the distance between the drape plate and the trocar. Experimental results show that error is induced by the asymmetric shape of the trocar tip because contact position between the instrument and the trocar tip is changed depending on the direction of the interaction force. The theoretical relation, therefore, is compensated and reduced. Average $L_2$ relative error of the estimated force in the x-direction and the y-direction is 5.81 % and 5.99 %, respectively.