• Title/Summary/Keyword: Measuring Organization

Search Result 273, Processing Time 0.022 seconds

A REVIEW OF NEUTRON SCATTERING CORRECTION FOR THE CALIBRATION OF NEUTRON SURVEY METERS USING THE SHADOW CONE METHOD

  • KIM, SANG IN;KIM, BONG HWAN;KIM, JANG LYUL;LEE, JUNG IL
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.939-944
    • /
    • 2015
  • The calibration methods of neutron-measuring devices such as the neutron survey meter have advantages and disadvantages. To compare the calibration factors obtained by the shadow cone method and semi-empirical method, 10 neutron survey meters of five different types were used in this study. This experiment was performed at the Korea Atomic Energy Research Institute (KAERI; Daejeon, South Korea), and the calibration neutron fields were constructed using a $^{252}Californium$ ($^{252}Cf$) neutron source, which was positioned in the center of the neutron irradiation room. The neutron spectra of the calibration neutron fields were measured by a europium-activated lithium iodide scintillator in combination with KAERI's Bonner sphere system. When the shadow cone method was used, 10 single moderator-based survey meters exhibited a smaller calibration factor by as much as 3.1-9.3% than that of the semi-empirical method. This finding indicates that neutron survey meters underestimated the scattered neutrons and attenuated neutrons (i.e., the total scatter corrections). This underestimation of the calibration factor was attributed to the fact that single moderator-based survey meters have an under-ambient dose equivalent response in the thermal or thermal-dominant neutron field. As a result, when the shadow cone method is used for a single moderator-based survey meter, an additional correction and the International Organization for Standardization standard 8529-2 for room-scattered neutrons should be considered.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

Game Theoretic Optimization of Investment Portfolio Considering the Performance of Information Security Countermeasure (정보보호 대책의 성능을 고려한 투자 포트폴리오의 게임 이론적 최적화)

  • Lee, Sang-Hoon;Kim, Tae-Sung
    • Journal of Intelligence and Information Systems
    • /
    • v.26 no.3
    • /
    • pp.37-50
    • /
    • 2020
  • Information security has become an important issue in the world. Various information and communication technologies, such as the Internet of Things, big data, cloud, and artificial intelligence, are developing, and the need for information security is increasing. Although the necessity of information security is expanding according to the development of information and communication technology, interest in information security investment is insufficient. In general, measuring the effect of information security investment is difficult, so appropriate investment is not being practice, and organizations are decreasing their information security investment. In addition, since the types and specification of information security measures are diverse, it is difficult to compare and evaluate the information security countermeasures objectively, and there is a lack of decision-making methods about information security investment. To develop the organization, policies and decisions related to information security are essential, and measuring the effect of information security investment is necessary. Therefore, this study proposes a method of constructing an investment portfolio for information security measures using game theory and derives an optimal defence probability. Using the two-person game model, the information security manager and the attacker are assumed to be the game players, and the information security countermeasures and information security threats are assumed as the strategy of the players, respectively. A zero-sum game that the sum of the players' payoffs is zero is assumed, and we derive a solution of a mixed strategy game in which a strategy is selected according to probability distribution among strategies. In the real world, there are various types of information security threats exist, so multiple information security measures should be considered to maintain the appropriate information security level of information systems. We assume that the defence ratio of the information security countermeasures is known, and we derive the optimal solution of the mixed strategy game using linear programming. The contributions of this study are as follows. First, we conduct analysis using real performance data of information security measures. Information security managers of organizations can use the methodology suggested in this study to make practical decisions when establishing investment portfolio for information security countermeasures. Second, the investment weight of information security countermeasures is derived. Since we derive the weight of each information security measure, not just whether or not information security measures have been invested, it is easy to construct an information security investment portfolio in a situation where investment decisions need to be made in consideration of a number of information security countermeasures. Finally, it is possible to find the optimal defence probability after constructing an investment portfolio of information security countermeasures. The information security managers of organizations can measure the specific investment effect by drawing out information security countermeasures that fit the organization's information security investment budget. Also, numerical examples are presented and computational results are analyzed. Based on the performance of various information security countermeasures: Firewall, IPS, and Antivirus, data related to information security measures are collected to construct a portfolio of information security countermeasures. The defence ratio of the information security countermeasures is created using a uniform distribution, and a coverage of performance is derived based on the report of each information security countermeasure. According to numerical examples that considered Firewall, IPS, and Antivirus as information security countermeasures, the investment weights of Firewall, IPS, and Antivirus are optimized to 60.74%, 39.26%, and 0%, respectively. The result shows that the defence probability of the organization is maximized to 83.87%. When the methodology and examples of this study are used in practice, information security managers can consider various types of information security measures, and the appropriate investment level of each measure can be reflected in the organization's budget.

Measuring the Seriousness of Adverse Drug Reactions : Comparisons between Korean Experts and WHO Working Group Members (의약품 부작용의 심각도 조사 비교분석)

  • Rhee, Jin-Nie;Park, Se-Young;Heo, Ji-Haeng;Park, Mi-Hae;Ha, Ji-Hye;Lee, Eui-Kyung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.3
    • /
    • pp.237-242
    • /
    • 2011
  • This study measures seriousness of adverse drug reactions (ADRs) among Korean physicians and pharmacists using two times surveys based on Delphi technique. Each participant scored 20 ADR terms on a scale of one to ten (10 being the most serious). We repeated the exercise for the 49 first survey respondents and 32 re-evaluated score. We compared the results of our survey with those of WHO CIOMS (Council for International Organization of Medical Sciences) working groups members conducted in 1995. The overall mean ADR seriousness score was 6.49 for Koreans and 5.12 for WHO CIOMS members, presenting Korean experts perceived more seriously for each ADR. Mean score changes for the same respondents showed similar trends regardless of access to the first survey results. There were no statistically significant score differences between the physicians and the pharmacists. The high consensus of seriousness for each ADR between the Korean experts and the WHO CIOMS members implies that the similar results are reproducible, suggesting the possibility of developing standardized tools for measuring the seriousness of individual ADRs in the future.

A Propensity of Formative Presentation by Line Drawing (라인드로잉에 의한 디자인 조형의 표현성향)

  • 우흥룡
    • Archives of design research
    • /
    • v.11 no.2
    • /
    • pp.95-103
    • /
    • 1998
  • During design thinking and developing, its idea into the real world, and we are under pattern recognition and gestalt principles of perceptual organization. Generally originality is a part of creativity which consists an integral factor of the designing. This is a study on the measure system for an ability of originality in design. It is reorganized that the OTLD(Originality Test of Line Drawing) is a measuring system for personal originality. In order to catch the development the thoughts, we presented 10 picture planes as stimuli (each picture plane contained 3-18 dots), recorded the tape displaying eye-mark trajectories and outputting the trajectories with EMR(Eye Mark Recorder), then found the process of visual sensation and perception. From the results of this study, we examined the relationships between connections and complexity of the objects on the picture plane, which could be transformed into some objective measuring parameters. We would suggest this OLTD as a measurement system for an ability of originality in design fields, but we couldn't find any reliability and validity for fine art fields.

  • PDF

A Study on the Applicability of the Conjoint Analylis for the Reference Evaluation (참고평가를 위한 Conjoint 분석법의 활용시도에 대한 연구)

  • Bae Soon Ja
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.15
    • /
    • pp.141-173
    • /
    • 1988
  • The focuses and methods in Library science have been changed abreast with the development af library facilities and with the expansion and diversification of its functions. One of current trends in Library science is focussed on the social functions of library: its relations to the public, effective service for the users. and efficieniencies of the management policies, and so. on. To. deal with these issues, we need to borrow methodology from other disciplines such as management, marketing, statistics, etc. This paper is mainly concerned with how we approach to the measurement af services and thus provide tentative standard for evaluating library services. To do. this work properly, we'd better consider the users' needs and expectations. But it is not an easy work since too many factors are involved in the study of the users' needs. Users' needs and expectations are so. varying that it is difficult to find out some general and objective data. That is the reason why although many scholars have urged time after time the necessity of library's effectiveness measurement, few studies demonstrated substantial method for measuring the effectiveness of service. In this paper I propose a device for measuring service: i. e, Conjoint Analysis. Conjoint Analysis, which has originally been developed and applied in marketing research, is used to measure the priorities and preferences of purchasers on the new item. So far as Conjoint Analysis, concerning users' physical and psychological necessities, can numeralize people's needs, it may also be applied to measure service provided by nonprofit organization like library. If this approach prove to be sucessful, I hope this study to make any contribution to the appropriate direction on improving library facilities based on the result from a concret reference evaluation.

  • PDF

Development of Safety Climate Measuring Software Tool (안전문화측정 전산화 프로그램 개발)

  • Baek, Jong-Bae;Ko, Jae-Wook
    • Journal of Energy Engineering
    • /
    • v.18 no.1
    • /
    • pp.63-68
    • /
    • 2009
  • The safety culture of an organization is very complex and hard to study, but it is possible to examine norms that make up the culture. This paper describes of a Process Safety Management (PSM) climate assessment tool developed in high risk industry such as chemical industries. The main purpose is to develop measuring software tool behaviors by examining their nature and strength and by analysing underlying factors that offer explanations for attitudinal differences. We reviewed the current techniques and literatures available to assess safety climate and culture, conducted focus group interviews and discussions. Based on the reviews and focus group, PSM climate assessment questionnaires and an online application program were developed. A pilot assessment was done at a chemical plant in Korea and the safety climate profile was completed. It was suggested to have a constant feedback from different sectors of industry to improve the application.

A Study in EMC Environment Measuring of Marine Ship (선박의 EMC 환경 측정에 관한 연구)

  • Kim, Dong-Seek;Cho, Hyung-Rae;Min, Kyeong-Sik
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.141-146
    • /
    • 2005
  • Recently, the accidents on the sea have arisen due to the increase of the nautical traffic and the digitization of equipments for marine. Therefore, IMO(International Maritime Organization) have provided the recommendation of EMI and EMS for radio communication and equipments of marine from SOLAS cobvention at July 1st 2002. In this paper, we measured EMC environment on the HANBADA, which is Korea Maritime University training ship, for basic EMC environment of a ship. The measuring point was Bridge and Engine Control Room of the ship, we measured the test point that was set at random. Measured Band is from 30 MHz to 2 GHz, polarization measurement is processed both vertical and horizontal polarizaion. We analysed the results in consideration of permissible criteria.

  • PDF

Development of a Web-Based Program for Cross-Calibration and Record Management of Radiation Measuring Equipment

  • Park, So Hyun;Lee, Rena;Kim, Kyubo;Ahn, Sohyun;Lim, Sangwook;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.30 no.2
    • /
    • pp.59-63
    • /
    • 2019
  • Purpose: To manage radiation measurement equipment, a web-based management program has been developed in this study. Materials and Methods: This program is based on a web service and Java Server Pages (JSP) and employs compatibility and accessibility. Results: The first step in the workflow has been designed to create accounts for each user or organization and to log in. The program consists of two parts: fields for listed instruments, and measurement information. The instruments for measuring radiation listed in this program are as follows: ionization chambers, survey meters, thermometers, barometers, electrometers, and phantoms. Instrument properties can be put in the recording fields and browsing for associated instruments can be performed. The main part of the program is the cross-calibration for each ion chamber. For instance, the ionization chamber to be used as a relative dosimeter can be registered by cross-calibration data with a reference chamber calibrated by an accredited laboratory. This program supports methods using the central axis transfer theory for cross-calibration for the ionization chambers. The reference and field ionization chambers were placed in a solid water phantom along the beam central axis at two different depths, and then the positions were switched. Each measured value was used for calculating the cross-calibration factor. Conclusions: Because many instruments are used and managed in radiation oncology departments, systematic, traceable recording is very important. The web-based program developed in this study is expected to be used effectively in the maintenance of radiation measurement instruments.