• Title/Summary/Keyword: Measurement sensor

Search Result 3,913, Processing Time 0.032 seconds

Structural Performance Tests of Down Scaled Composite Wind Turbine Blade using Embedded Fiber Bragg Grating Sensors

  • Kim, Sang-Woo;Kim, Eun-Ho;Rim, Mi-Sun;Shrestha, Pratik;Lee, In;Kwon, Il-Bum
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • In this study, the structural performance tests, i.e., static tests and dynamic tests of the composite wind turbine blade, were carried out by using the embedded fiber Bragg grating (FBG) sensors. The composite wind turbine blade used in the test is the 1/23 scale of the 750 kW composite blade. In static tests, the deflections along the blade were evaluated. Evaluations were carried out with simple beam theory and quadratic fitting method by using the embedded FBG sensors to predict the structural behavior with respect to the load. The deflections were compared to those obtained from the laser displacement sensor and electric strain gauges. They showed good agreement. Modal tests were performed to investigate the dynamic characteristics using the embedded FBG sensors. The natural frequencies obtained from the FBG sensors corresponding to the nine mode shapes of the blade were compared to those from the laser Doppler vibrometer. They were found to be consistent with each other. Therefore, it is concluded that the embedded FBG sensors have a great capability for measuring the structural performances of the composite wind turbine blade when structural performance tests are carried out.

Crystalline structure and electrical properties of PbSe thin films prepared using PLD method (PLD 법으로 제작한 PbSe 박막의 결정구조와 전기적 특성)

  • Park, Jong-Man;Lee, Hea-Yeon;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.476-480
    • /
    • 1999
  • PbSe thin films were grown using PLD method on the p-Si(100) substrate. To determine what crystalline structure of PbSe thin films have according to the growth temperature, the films were prepared under a substrate temperature changing between a room temperature and $400^{\circ}C$. As a result of analyzing XRD patterns of PbSe thin films prepared at various substrate temperatures and FWHM of PbSe(200) rocking curve, it was found that PbSe thin film obtained at the growth temperature of $200^{\circ}C$ was best crystallized. In addition, the surface morphology of PbSe thin film observed using AFM found itself having the most regularly arranged particles in case of growing the film at $200^{\circ}C$. The measurement of Hall effect indicated that PbSe thin films were n-type semiconductors and that current-voltage characteristic curve exhibit the typical p-n junction phenomenon. In addition, electric conductivity of PbSe thin films was found somewhat higher than that of general semiconductors.

  • PDF

Measurement of Traceability Error for Calibration Service Center Using Type S Thermocouples (S형 열전대를 이용한 교정검사기관의 소급성 오차측정)

  • Gam, Kee-Sool;Kim, Yong-Gyoo;Kim, Sun-Gon
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.43-50
    • /
    • 1995
  • We measured the traceability error for nine high temperature calibration service centers including KRISS through the round-robin test. In this test the type S thermocouple, which used as a calibration standard thermometer commonly, was accommodated as a test thermocouple. Intercomparison data of three institutions were coincident with KRISS's data within ${\pm}0.5^{\circ}C$, which was the calibration uncertainty of the type S thermocouple, but the remaining six institution's data were deviated from the assigned uncertainty level. Deviation of the intercomparison data increased gradually according to the increase of the test temperature. and the maximum difference was so large as about $2.0^{\circ}C$ at the highest test temperature, gold point. In this study we found the traceability error of high temperature calibration service center for a high temperature standard was within $2.0^{\circ}C$.

  • PDF

Enhancement of signal-to-noise ratio for uroflowmetric test regardless of urination situation (요속검사시 배뇨상황에 무관한 신호대잡음비 개선 기법)

  • Kim, Kyung-Ah;Choi, Seong-Su;Lee, Sang-Bong;Kim, Kyoung-Oak;Park, Kyung-Soon;Shin, Eun-Young;Kim, Wun-Jae;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.423-431
    • /
    • 2009
  • Standard uroflowmetry measures the urine weight using single load cell to evaluate the urinary flow rate. Impact noise should be introduced due to gravity when the urine stream falls down into the container upon the load cell. The present study placed three load cells on the three vertices of a regular triangle and the three signals were ensemble averaged to enhance the signal-to-noise ratio(SNR) regardless of how the urination was made. Simulated urination experiment was performed with three different urine collection methods. In all three methods, SNR of the averaged signal was much higher than each load cell signals. With no urine collection device, the present signal averaging technique resulted in SNR values higher by 10~15 dB than when dual funnels or upper funnel were used to guide the urine stream. Therefore, it was demonstrated that the three point measurement followed by with ensemble averaging could enable accurate uroflowmetric test without any specially made urine collection devices.

Geometric Calibration and Accuracy Evaluation of Smartphone Camera (스마트폰 카메라의 기하학적 검정과 정확도 평가)

  • Kim, Jin-Soo;Jin, Cheong-Gil;Lee, Seong-Kyu;Lee, Sun-Gu;Choi, Chul-Uong
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.3
    • /
    • pp.115-125
    • /
    • 2011
  • The smartphones which have been recently are embedded with high resolution quality camera, assisted GPS, accelerometer, gyroscope and various sensors including magnetometer sensor that could be directly used for measurement. This study aims to suggest the possible application of smartphone camera providing high resolution images in terms of photogrammetry by calibrating it and assessing its accuracy. First of all, prior to the accuracy assessment of smartphone camera, camera calibration was conducted to correct lens distortion of each camera and the accuracy of image coordinates and object coordinates calculated by bundle adjustment during this procedure was analyzed. Also regarding three-dimensional positioning, result analysis depending on considering lens distortion coefficients was conducted, and finally relative accuracy of smartphone camera on metric camera was assessed. The result showed that in terms of distortion correction of smartphone camera, also higher order symmetric radial lens distortion coefficients should be considered, and three dimensional position determined by smartphone images was a little difference from that by metric camera. Therefore it is expected that smartphone images have huge possibility to be used for photogrammetry.

X3D Based Web Visualization by Data Fusion of 3D Spatial Information and Video Sequence (3D 공간정보와 비디오 융합에 의한 X3D기반 웹 가시화)

  • Sohn, Hong-Gyoo;Kim, Seong-Sam;Yoo, Byoung-Hyun;Kim, Sang-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.4
    • /
    • pp.95-103
    • /
    • 2009
  • Global interests for construction of 3 dimensional spatial information has risen due to development of measurement sensors and data processing technologies. In spite of criticism for the violation of personal privacy, CCTV cameras equipped in outdoor public space of urban area are used as a fundamental sensor for traffic management, crime prevention or hazard monitoring. For safety guarantee in urban environment and disaster prevention, a surveillance system integrating pre-constructed 3 dimensional spatial information with CCTV data or video sequence is needed for monitoring and observing emergent situation interactively in real time. In this study, we proposed applicability of the prototype system for web visualization based on X3D, an international standard of real time web visualization, by integrating 3 dimensional spatial information with video sequence.

  • PDF

An Experimental Study on the Measurement of Flow Field in a Direct Diesel Engine Using a Single Cylinder Visualization Engine (가시화 엔진을 이용한 직분식 디젤엔진내의 유동장 측정에 관한 연구)

  • Han, Yong-Taek;Hwang, Kyu-Min;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.129-137
    • /
    • 2006
  • This paper studies the effects of the swirl for the variation of intake port configuration that is key parameters in the flow field of direct injection diesel engines. In-cylinder flow characteristics is known to have significant effects on air-fuel mixing, combustion, and emissions. To investigate the effects of the swirl flow, various rpm(250, 500, 750) and two different intake port were used. And to evaluate the swirl motion in the flow field visualization engine, steady state flow test was conducted. Helical port intake port and SCV(Swirl Control Valve) were selected as the design parameters to increase the swirl flow and parametric study was performed. In the case of non-SCV, intake flow rate and non-dimensional swirl ratio were higher than those of SCV for the swirl head type. So, we could strengthen the swirl in the flow field with the swirl head type and don't using SCV. From the results of steady state flow test, non-swirl head type has the most good advantage for intake flow rate, and also the flow rate could be increased by using the SCV slightly. The effects of the type of engine head on intake air flow capability are dominant with respect to the existence of the SCV. We could measure the qualitative grade of swirl by capturing the scattering signal of microballoon from ICCD camera in the visualization diesel engine.

Evaluation of Tractor PTO Severeness during Rotary Tillage Operation (로타리 경운작업 시 트랙터 PTO 가혹도 평가)

  • Kim, Yong-Joo;Chung, Sun-Ok;Choi, Chang-Hyun;Lee, Dae-Hyun
    • Journal of Biosystems Engineering
    • /
    • v.36 no.3
    • /
    • pp.163-170
    • /
    • 2011
  • Analysis of load on major parts of the tractor power drive line is critical for efficient and optimum design of a tractor. The purpose of this study was to evaluate severeness of the tractor PTO driving axle during rotary tillage operation. First, S-N (stress vs. number of cycle) curve of a PTO driving gear was obtained through the fatigue life test using a PTO dynamometer. Second, PTO severeness was evaluated during rotary tillage operation. Torque measurement system was constructed with strain-gauge sensors to measure torque of a PTO axle, an I/O interface to acquire the sensor signals, and an embedded system to calculate severeness. The severeness of PTO was analyzed using measured torque data during rotary tillage. In the PTO gear life fatigue test, breakage time and bending stress of the gear were measured by tooth widths and torque change during the fatigue life test. The S-N curve showed a good linear relationship between bending stress and number of cycle (life) with a coefficient of determination of 0.97. For PTO severenss evaluation, rotary tillage operations were conducted at two PTO rotational speeds (level-1, level-2) under different paddy and upland field sites with different soil conditions. Results of averaged relative severeness for PTO level-1 and PTO level-2 were 1.96 and 3.34, respectively, at paddy field sites, and they were 1.36 and 2.51, respectively, at upland field sites. The results showed that the PTO driving axle experienced more severe load during rotary tillage at paddy fields than at upland sites, and relative severeness was greater at the higher PTO rotational speed under all of the soil conditions.

Structure and Electrical Properties of PbTe Thin Film According To The Substrate Temperature (기판온도에 따른 PbTe 박막의 구조 및 전기적 물성)

  • Lee, Hea-Yeon;Choi, Byung-Chun;Jeong, Jung-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.184-188
    • /
    • 1999
  • PbTe thin films of high quality were deposited on HF-treated Si(100) substrates at various substrate temperature by pulsed laser deposition technique. XRD patterns showed that PbTe layers were well-crystallized to a cubic phase with (h00) preferred orientation with the substrate temperature up to $300^{\circ}C$. PbTe films could not form at substrate temperature above $400^{\circ}C$ because of reevaporation of the Pb. According to AFM image, the surface of films was composed of small granular crystals and flat matrix. According to the increase of substrate temperature, the grain size at film surface becomes larger. By Hall-effect measurement, the carrier concentration and Hall mobility of n-type PbTe films grown by $T_{sub}=300^{\circ}C$ were $3.68{\times}10^{18}cm^{-3}$ and $148\;cm^2/Vs$, respectively.

  • PDF

An Analysis System Using Big Data based Real Time Monitoring of Vital Sign: Focused on Measuring Baseball Defense Ability (빅데이터 기반의 실시간 생체 신호 모니터링을 이용한 분석시스템: 야구 수비능력 측정을 중심으로)

  • Oh, Young-Hwan
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.221-228
    • /
    • 2018
  • Big data is an important keyword in World's Fourth Industrial Revolution in public and private division including IoT(Internet of Things), AI(Artificial Intelligence) and Cloud system in the fields of science, technology, industry and society. Big data based on services are available in various fields such as transportation, weather, medical care, and marketing. In particular, in the field of sports, various types of bio-signals can be collected and managed by the appearance of a wearable device that can measure vital signs in training or rehabilitation for daily life rather than a hospital or a rehabilitation center. However, research on big data with vital signs from wearable devices for training and rehabilitation for baseball players have not yet been stimulated. Therefore, in this paper, we propose a system for baseball infield and outfield players, especially which can store and analyze the momentum measurement vital signals based on big data.