• Title/Summary/Keyword: Measurement results

Search Result 19,341, Processing Time 0.051 seconds

A Study on Exposure to radiation of the patient who visited an emergency room at a University Hospital (한 대학병원 응급실에 방문한 환자의 방사선 피폭에 관한 연구)

  • Ahn, Buyung-Ju;Lee, Sang-Bock;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.3
    • /
    • pp.23-34
    • /
    • 2007
  • To find how much radiation was exposed the patients who visit emergency room, a measurement study was made for radiation amount toward 200 patients selected randomly among visitors to an emergency room in a university hospital from March 16 to 31st, 2006. The results are as follows ; 1. Among the subjects 50 person(25.0%) were transferred from other hospitals, 24 persons(8.3) come after traffic accident, 50 persons for other accident and 76 persons for general medical care. 2. The average frequency of X-ray taking was calculated as 6.4 time per person among transferred patients, 14.5 times per person among patients with traffic accident and 2.6 times per person among general medical care. 3. The radiation exposure amount by kind of X-ray showed 28.9mGyfor general X-ray diagnosis, 84.2mGy for CT scanning and 1.02mGy for other special radiation study. 4. Average radiation exposure amount was calculated as 24.6mGy by transferred patients, 55.2mGy by patients with traffic accident, 17.1mGy by patients with other accidents and 17.0mGy by general patients. 5. Through the comparison of radiation exposure amount among to subject with maximum allowance threshold by International Commission on X-ray Radium Protection, transferred patients exceeded 6 times than allowance in whole body except extremities and joints, blood forming organ, reproductive system, vitreous body of eye, bone, thyroid gland, skin and etc, Patient suffered from traffic accidents were exposed 10 times more than allowance. In conclusion, the radiation exposure amount during X-rat diagnosis re too much and exceeded allowance standard by International Commission on X-ray Radium Protection. So further study and preventive measure to decrease radiation exposure by patients who visit emergency room.

  • PDF

Clinical Usefulness of Serum Uric Acid in Gastroenteritis Patients with lJehydration (급성장염으로 인한 탈수 환아에서 혈청 요산의 염상적 유용성)

  • Song, Jun Ho;Jang, Myung Wan;Yoo, Hwang Jae;Kim, Cheol Hong
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.9 no.1
    • /
    • pp.23-30
    • /
    • 2006
  • Purpose: The estimation of fluid deficit is crucial to the proper management of dehydrated children. Without well-documented serial weights on the same scale, the estimation of any given child's fluid deficit is imprecise and dependent largely on subjective clinical criteria. Despite the abundance of literature on clinical and laboratory evaluation of dehydration, few studies have focused on serum uric acid. So, we examined the usefulness of scrum uric acid in gastroenteritis patients with dehydration. Methods: Medical records of 90 gastroenteritis patients were retrospectively reviewed. By the body weight loss, we classified patients with mild, moderate, and severe dehydration groups. We studied the relevance of laboratory data (BUN, creatinine, serum bicarbonate, glucose, urine specific gravity, and uric acid) with dehydration. Results: 54 children (60%) were dehydrated mildly, 24 (26%) dehydrated and moderately, and 12 (14%) dehydrated severely. Statistically significant differences in BUN, creatinine, serum bicarbonate, glucose, and urine specific gravity could not be observed. But there was significant relationship between uric acid and the degree of dehydration. Data analysis suggested that the level of 7.0 mg/dL is the best cut-off value for predicting the development of moderate or severe dehydration. At this cut-off value, the sensitivity and specificity were 66.6% and 87.1%. Conclusion: Our study supports that the measurement of serum uric acid with traditional scale is useful for predicting the development of dehydration. But, in order 10 be used as the indicator for proper treatment at an earlier stage, further validation about serum uric acid is necessary.

  • PDF

The Effects of LBS Information Filtering on Users' Perceived Uncertainty and Information Search Behavior (위치기반 서비스를 통한 정보 필터링이 사용자의 불확실성과 정보탐색 행동에 미치는 영향)

  • Zhai, Xiaolin;Im, Il
    • Asia pacific journal of information systems
    • /
    • v.24 no.4
    • /
    • pp.493-513
    • /
    • 2014
  • With the development of related technologies, Location-Based Services (LBS) are growing fast and being used in many ways. Past LBS studies have focused on adoption of LBS because of the fact that LBS users have privacy concerns regarding revealing their location information. Meanwhile, the number of LBS users and revenues from LBS are growing rapidly because users can get some benefits by revealing their location information. Little research has been done on how LBS affects consumers' information search behavior in product purchase. The purpose of this paper is examining the effect of LBS information filtering on buyers' uncertainty and their information search behavior. When consumers purchase a product, they try to reduce uncertainty by searching information. Generally, there are two types of uncertainties - knowledge uncertainty and choice uncertainty. Knowledge uncertainty refers to the lack of information on what kinds of alternatives are available in the market and/or their important attributes. Therefore, consumers having knowledge uncertainty will have difficulties in identifying what alternatives exist in the market to fulfil their needs. Choice uncertainty refers to the lack of information about consumers' own preferences and which alternative will fit in their needs. Therefore, consumers with choice uncertainty have difficulties selecting best product among available alternatives.. According to economics of information theory, consumers narrow the scope of information search when knowledge uncertainty is high. It is because consumers' information search cost is high when their knowledge uncertainty is high. If people do not know available alternatives and their attributes, it takes time and cognitive efforts for them to acquire information about available alternatives. Therefore, they will reduce search breadth. For people with high knowledge uncertainty, the information about products and their attributes is new and of high value for them. Therefore, they will conduct searches more in-depth because they have incentive to acquire more information. When people have high choice uncertainty, people tend to search information about more alternatives. It is because increased search breadth will improve their chances to find better alternative for them. On the other hand, since human's cognitive capacity is limited, the increased search breadth (more alternatives) will reduce the depth of information search for each alternative. Consumers with high choice uncertainty will spend less time and effort for each alternative because considering more alternatives will increase their utility. LBS provides users with the capability to screen alternatives based on the distance from them, which reduces information search costs. Therefore, it is expected that LBS will help users consider more alternatives even when they have high knowledge uncertainty. LBS provides distance information, which helps users choose alternatives appropriate for them. Therefore, users will perceive lower choice uncertainty when they use LBS. In order to test the hypotheses, we selected 80 students and assigned them to one of the two experiment groups. One group was asked to use LBS to search surrounding restaurants and the other group was asked to not use LBS to search nearby restaurants. The experimental tasks and measures items were validated in a pilot experiment. The final measurement items are shown in Appendix A. Each subject was asked to read one of the two scenarios - with or without LBS - and use a smartphone application to pick a restaurant. All behaviors on smartphone were recorded using a recording application. Search breadth was measured by the number of restaurants clicked by each subject. Search depths was measured by two metrics - the average number of sub-level pages each subject visited and the average time spent on each restaurant. The hypotheses were tested using SPSS and PLS. The results show that knowledge uncertainty reduces search breadth (H1a). However, there was no significant correlation between knowledge uncertainty and search depth (H1b). Choice uncertainty significantly reduces search depth (H2b), but no significant relationship was found between choice uncertainty and search breadth (H2a). LBS information filtering significantly reduces the buyers' choice uncertainty (H4) and reduces the negative relationship between knowledge uncertainty and search breadth (H3). This research provides some important implications for service providers. Service providers should use different strategies based on their service properties. For those service providers who are not well-known to consumers (high knowledge uncertainty) should encourage their customers to use LBS. This is because LBS would increase buyers' consideration sets when the knowledge uncertainty is high. Therefore, less known services have chances to be included in consumers' consideration sets with LBS. On the other hand, LBS information filtering decrease choice uncertainty and the near service providers are more likely to be selected than without LBS. Hence, service providers should analyze geographically approximate competitors' strength and try to reduce the gap so that they can have chances to be included in the consideration set.

Determination of Representative Renal Depth for Accurate Attenuation Correction in Measurement of Glomerular Filtration Rate in Transplanted Kidney (이식 신의 사구체 여과율 측정에서 정확한 감쇄 보정을 위한 신장 깊이 대표값 설정)

  • Oh, Soon-Nam;Kim, Sung-Hoon;Rha, Sung-Eun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Lee, Sung-Young;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2002
  • Purpose: To measure reliable glomerular filtration rate by using the representative values of transplanted renal depths, which are measured with ultrasonography. Materials and Methods: We included 54 patients (26 men, 28 women), with having both renal scintigraphy and ultrasonography after renal transplantation. We measured GFR with Gates' method using the renal depth measured by ultrasonography, and median and mean ones in each patient. We compared GFR derived from ultrasonography-measured renal depth with GFR derived from median and mean renal depths. The correlation coefficients were obtained among GFR derived from ultrasonography-measured renal depths, median and mean renal depths under linear regression analysis. We determined whether GFR derived from median or mean renal depth could substitute GFR derived from ultrasonography-measured renal depth with Bland-Altman method. We analyze the expected errors of the GFR using representative renal depth in terms of age, sex, weight, height, creatinine value, and body surface. Results: The transplanted renal depths range from 3.20 cm to 5.96 cm. The mean value and standard deviation of renal depths measured by ultrasonography are $4.09{\pm}0.65cm$ in men, and $4.24{\pm}0.78cm$ in women. The median value of renal depths measured by ultrasonography is 4.36 cm in men and 4.14 cm in women. The GFR derived from median renal depth is more consistent with GFR derived from ultrasonography-measured renal depth than GFR derived from mean renal depth. Differences of GFR derived from median and ultrasonography-measured renal depth are not significantly different in the groups classified with creatinine value, age, sex, height, weight and body surface. Conclusion: When median value is adapted as a representative renal depth, we could obtain reliable GFR in transplanted kidney simply.

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

An Assessment of the Utility of Respiratory Synchronized Systems in the PET/CT Examination (PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가)

  • Seong, Yong-Jun;Yoon, Seok-Hwan;Hyun, Jun-Ho;Lee, Hong-jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.34-38
    • /
    • 2017
  • Purpose During PET/CT examinations, the movements of internal organs caused by respiration are captured in images during multiple breathing cycles, resulting in the increases in tumor size and effects on SUV. Respiratory synchronized systems were used to evaluate tumor sizes and SUV changes. Materials and Methods Biograph mCT 64 was used for the equipment, and RPM and Anzai systems were used for the respiratory synchronized systems. We used point source and micro-phantom for an experimentation. We were performed on 12 patients who had solid tumors discovered at the base of the lung or at the top of the liver from August through September 2016. The PET images of the exhalation-to-breathing state and the CT images of the post-exhalation suspension state were gained to evaluate changes in radioactivity concentration (KBq/mL), SUVmax, cylinder diameter (mm), and tumor diameter (cm) under the conventional Static, RPM, and Anzai methods. Results The result of measuring the radioactivity concentration of the point source was RPM 94% and Anzai 91% against Static, respectively. In the two cylinders of different radioactivity in the micro-phantom, the SUVmax increased to RPM 61% and 78%, and Anzai 58% and 77% against Static, whereas the cylinder diameters decreased by RPM -26% and -28%, and Anzai -28% and -26%, each respectively. Among the patients, the SUVmax increased from a minimum of RPM 8.2% to a maximum of 94.4% against Static, and from a minimum of Anzai 7.6% to a maximum of 68.3%, respectively. As for the tumor diameters, a minimum of RPM -7.6% to a maximum of -28.9% were achieved, while the Anzai fell by a minimum of -9.6% to a maximum of -27.7%, respectively. There was no significant difference discovered in the phantom study between the RPM and Anzai, yet there was a meaningful difference in the patients' tumors (P<0.05). Conclusion The respiratory synchronized systems of RPM and Anzai yielded no significant difference in the phantom study in which the respiration was executed at regular intervals. However, it was discovered that the patients had a meaningful difference for the irregular respiratory cycle and inter-system differences. Still, the respiratory synchronized systems would be useful for the accurate diagnosis and SUV measurement as the tumor decreased in size against the existing Static and the SUV increased.

  • PDF

Multicenter, Open-Labeled, Observational Clinical Trial to Investigate the Efficacy and Safety of Oral Administration of Megace Suspension in Patients with Head and Neck Cancer During Radiotherapy (방사선 치료 중인 두경부 종양 환자를 대상으로 메게이스 내복 현탁액 경구투여 후 유효성 및 안전성에 관한 다기관, 공개, 관측연구)

  • Kim, Se-Heon;Kim, Min-Sik;Kim, Young-Mo;Kim, Hyun-Su;Nam, Soon-Yuhl;Rho, Young-Soo;Park, Young-Hak;Baek, Chung-Hwan;Bong, Jung-Pyo;Lee, Kang-Dae;Lee, Yong-Seop;Jung, Kwang-Yoon;Chung, Sung-Min;Chung, Pil-Sang;Joo, Young-Hoon;Chu, Hyung-Ro;Choi, Eun-Chang;Tae, Kyung;Hong, Ki-Hwan
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.1
    • /
    • pp.57-63
    • /
    • 2008
  • Background and Purpose:Nausea, vomiting and weight loss are common problems that are encountered in the course of cancer patient treatment who are receiving radiotherapy. In this study, we are aiming to analyze the effect of megestrol acetate on quality of life of head and neck cancer patients receiving radiotherapy, resulting from improvement of weight loss, appetite and nutritional status via multicenter, open-labeled, observational clinical trial. Material and Methods:A total of 270 patients from 10 medical institutes who are receiving radiotherapy or who have completed radiotherapy within 3 months, between February 2007 and February 2008, were selected as candidates for the study. Megestrol acetate suspension(megace) was given to the subjectives once a week for 4 weeks with the amount of 20ml(megestrol 800mg). Measurement of weight and questionnaire surveys were carried out three times: at the start of the study, 4 weeks after the start of the medication, and 4 weeks after the end of the medication, respectively. Results:The group who has received megace had a total number of 199, and control group was 70. The group who have received megace showed mean weight loss of 1kg in 8 weeks, compared with the weight loss of 5.5kg in control group, which showed that the medication was effective in reducing the amount of weight loss(P=0.027). The group who received megace had a tendency to report a reduced rate of decrease in the score of appetite, nausea and vomiting, and QOL score, but it did not have statistical significance(P>0.05). Conclusion:Megestrol acetate have reduced the degree of weight loss significantly, and it has a tendency to reduce the rate of decrease in appetite, aggravation of nausea and vomiting, and quality of life.

Change of Texture of Back-pyun as affected by glutinous-rice (찹쌀첨가량에 따른 백편의 조직감 특성의 변화)

  • Lee, Yun-Kyung;Lee, Hyo-Gee
    • Korean journal of food and cookery science
    • /
    • v.2 no.2
    • /
    • pp.43-54
    • /
    • 1986
  • Back-pyun is a kind of rice cake made by steaming rice flour added sugar, water and salt and garnished with shredded chestnuts, dates, mushrooms and pinenuts. The Back-pyun has been widely used in Korean celebrations. This study aimed to compare and determine the effects on sensory characteristics and texture of Back-pyun 1) when the proportion of glutinous rice, added i.1 making Back-pyun, is 0%, 5%, 10%, 15%, 20%, 25% and 30% 2) then it reheated after storage for 0,24, 48 and 72 hours. Evaluation was conducted through sensory evaluation and objective evaluation. The results are as follows : 1. In sensory evaluation, color of Back-pyun turned yellow as the addition level of glutinous rice increased and then by reheating after storage for 24, 48 and 73 hours. Coarseness was not significantly different as the addition level of glutinous rice increased before storage. But Back-pyun reheated after storage for 24,48 and 72 hours were significantly different by the addition level of glutinous rice. Softness, dryness and crumblyness tended to decrease as the addition level of glutinous rice increased and by reheating after storage for 24, 48 and 72 hours. The most favorite tendency on the appearance was at the addition level of glutinous rice of 5%. Texture and overall preference were better at the addition level from 10% to 20% than any other levels. 2. Rheometer measurement indicated that compression force, gumminess ana chewiness tended to increase as the addition level of glutinous rice increased and decrease by the storage conditions. But work ratio and recovered height did not have much effect the addition level of glutinous rice and the storage conditions. Compression force of Back-pyun (not reheated) tended to increase by the storage time and the addition level of glutious rice. Especially it showed remakably increasing tendency during 24 hours storage (at $4^{\circ}C$) 3. Moisture content tended to increase by the addition level of glutinous rice and decrease by the storage time. But moisture content of Back-pyun reheated after storage for 24 hours stowed the increasing tendency. 4. Softness of Back-pyun had significant relationship with compression force and work ratio. Dryness and crumblyness had significant relationship with work ratio. Therefore compression force and work ratio represented the texture of Back-pyun.

  • PDF

Study on the Qualitative Discrimination of White, Red, and Black Ginseng Extract (백삼,홍삼과 흑삼 추출물의 정성적 구별법에 관한 연구)

  • Lee, Young-Sang;Im, Deok-Ho;Yang, Jin-Chul;Noh, Deok-Soo;Kim, Kwang-Il;Oh, Soo-Kyo;Choi, Kyo-Chan;Cha, Yun-Hwan
    • The Korean Journal of Food And Nutrition
    • /
    • v.24 no.1
    • /
    • pp.138-143
    • /
    • 2011
  • This study analyzed the maltol quality, composition ratio of fatty acids, and contents of phenolic compounds in white ginseng extracts(four types), red ginseng extracts(five types), black ginseng extracts(two types), and Chinese ginseng extracts(nine types). By examining patterns in these measurements, we determined the characteristic factors of the extracts and measured the possibility of qualitative analysis. In the analysis of maltol using TLC, white ginseng extracts were not detected while red and black ginseng extracts were detected, so the possibility of detection was considered as a characteristic factor for qualitative analysis. Regarding the composition of fatty acids, palmitic and linoleic acids were the main fatty acids in the ginseng extracts palmitic acid was high in white ginseng extracts while linoleic was low in red ginseng extracts. Regarding the ratio(Pal/Lin) of the two fatty acids, there was a large difference between white ginseng extracts(56.7~64.3%) and red ginseng extracts(32.0~38.5%), and these figures seemed to be characteristic factors for the analysis. For the phenolic compounds, extracts contained maltol, caffeic acid, syringic acid, p-coumaric acid, ferulic acid, and cinnamic acid. White ginseng extracts contained similar percentages of phenolic compounds while red ginseng extracts had high maltol content. According to the measurement results of the percentages of maltol and cinnamic acid, white ginseng extracts showed values below five, whereas red and black ginseng extracts showed 53~289, which was also a characteristic factor for qualitative analysis. Consequently, we found that we can differentiate between ginseng extracts using characteristic factors that we analyzed in an experiment on white ginseng extracts from China.

Anterior Cruciate Ligament Reconsruction Using Tibialis Tendon Allograft - A Short-Term Follow-Up Result - (동종 경골건을 이용한 전방 십자 인대 재건술 -단기 추시 결과-)

  • Woo, Jong-Ken;Ko, Sang-Hun;Lew, Sog-u;Park, Moon-Soo;Jung, Kwang-Hwan;Gwak, Chang-Youl;Lee, Chae-Chil;Cho, Sung-Do
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.89-93
    • /
    • 2004
  • Purpose: To evaluate the clinical stability and function after arthroscopic anterior cruciate ligament(ACL) reconstruction using fresh-frozen tibialis tendon allograft. Materials and Methods: Of the patients who underwent ACL reconstruction using tibialis tendon allograft from July 2002 to June 2003, thirty-one patients could be evaluated and the mean follow-up period was 19 months. Evaluations included were Lysholm knee score, 2000 International knee Documentation Committee (IKDC) subjective knee score, Lachman test, pivot shift test, KT-1000 arthrometer measurement and 2000 IKDC knee examination. Results: The mean Lysholm score was 88. Twenty-eight patients (90.3%) were good or exellent for the measured parameters. Twenty-seven patients(87.1%) was over 70 in IKDC subjective knee score. Thirty patients (96.8%) had 1+ firm end or negative Lachman test. 27 patients (87.1%) had a negative pivot shift. Thirty patients (96.8%) had less than 5mm difference of maximal manual difference by KT-1000 arthrometer. Twenty -nine patients (93.5%) were nearly normal or normal grade by 2000 IKDC knee examination. Complications were 1 case of failure and 1 case of infection. Conclusion: ACL reconstruction with the double-stranded fresh-frozen tibialis tendon allograft resulted in a reliable and predictable outcome after short-term follow-up.

  • PDF