• Title/Summary/Keyword: Measurement development

Search Result 6,872, Processing Time 0.041 seconds

The Development of Hemodiafiltration Treatment Compliance Indicators and Discriminant Standards, Development of Hemodiafiltration Treatment Compliance Measurement - Convergent Form(HDFTCM-CF) : Focused on On-line Hemodiafiltration (혈액여과투석 환자의 치료이행 지표와 분류기준, 융합형 혈액여과투석 치료이행 측정도구 개발 : 온라인 혈액여과투석을 중심으로)

  • Hur, Jung
    • Journal of Digital Convergence
    • /
    • v.13 no.7
    • /
    • pp.269-282
    • /
    • 2015
  • This study is to define the hemodiafiltration treatment compliance indicators and discriminate standards for hemodiafiltration patients and development of hemodiafiltration treatment compliance measurement-convergent form. Date was collected from 300 on-line hemodiafiltration patients. To verify the hemodiafiltration treatment compliance indicators and discriminate standards, used construct validity and content validity by clinical professional group. Discriminant ability of 3 indicators-interdialysis weight gain rate(IWGR), serum phosphate level, rate of self change of total hemodiafiltration treatment time(SCR-HEFTT)- is 95.6%(wilks ramda=.256, p=.002). And hemodiafiltration treatment compliance measurement-convergent form has 91.7% discriminant accuracy. Hemodiafiltration treatment compliance is important that nurses can aware pre-stage of complication and give appropriate nursing intervention. Also this measurement can be used for foundation data of the nursing intervention development that prevent dialysis patient's complication.

Development of Sensible Brassiere for Middle Aged Women -Investigation of consumer's Needs and Evaluation of Commercial Brassiere for the Development of Subjective Measurement Scale and Screening of Design Parameters- (중년 여성의 감성 Brassiere 개발(제1보) -소비자 요구 분석을 기초로 한 제품 디자인 요소 추출-)

  • 김정화;이선영;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.5
    • /
    • pp.714-723
    • /
    • 2000
  • The purpose of this study is to develop functional and sensible brassiere for middle-aged women. As a methodology, engineering design process, especially, QFD(Quality Function Deployment) was adopted to translate consumer's needs into product design parameters. Wearing tests of commercial brassiere were performed for the development o subjective measurement scale. The environmental condition was controlled at 28$\pm$1$^{\circ}C$, 65$\pm$3%RH. As results, subjective measurement scale and dimension for the evaluation of sensible brassiere were extracted from factor analysis. Four factors were fitting, aesthetic property, pressure sensation, displacement of brassiere due to movement. Regression equations with the subjective evaluation descriptors were developed for the prediction of wearing comfort of brassiere. (R2=.82) The most critical design parameter was wire-related property and second one was stretchability of main material of brassiere. Also, wearing comfort of brassiere was affected by the interaction of initial stretchability of wing and support of strap.

  • PDF

A Study on Overall Measurement System Development of HEMU-400X (HEMU-400X 종합계측시스템 개발에 관한 연구)

  • Ryu, Sang-Hyun;Hong, Jun-Hee
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.484-488
    • /
    • 2011
  • Technologically advanced railway countries had a unique ability to design, test and evaluation systems for development of High-speed train system. To evaluate the performance of the train system in Korea for the development of advanced measurement technology and systems are needed. In this study, the Overall Measuring System(OMS) is going to be established to efficiently verify the performance, stability and reliability of the train system and the components, and verify of the maximum speed though an on-line test. OMS consist of vehicle measuring system, pantograph measuring system, video monitoring system and monitoring room was constructed for the overall measuring system and monitoring system. The results of this study were expected to contribute to technical improvement for evaluation of train system.

Self-Alignment/Navigation Performance Analysis in the Accelerometer Resonance State Generated by Dither Motion of Ring Laser Gyroscope in Laser Inertial Navigation System (레이저 관성항법장치에서 링레이저 자이로 디더 운동에 의한 가속도계 공진이 자체 정렬/항법 성능에 미치는 영향 분석)

  • Kim, Cheonjoong;Lim, Kyungah;Kim, Seonah
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.577-590
    • /
    • 2021
  • In this paper, we theoretically analyzed the self-alignment/navigation performance in the accelerometer resonance state generated by dither motion of ring laser gyroscope in LINS and verified it through simulation. As a result of analysis, it is confirmed that the amplitude of the accelerometer measurement amplified in the accelerometer resonance state is decreased in the process of sampling per the navigation calculation period and that frequency is changed by the aliasing effect too. It was also analysed that the attitude error in self-alignment is determined by the amplitude/frequency of the accelerometer measurement, the gain of the self-alignment loop, and the velocity and position error in the navigation is determined by the amplitude/frequency/phase error of the accelerometer measurement. This analysis and simulation results show that the self-alignment and navigation performance is not be degraded only when the amplification factor of the accelerometer measurement in the accelerometer resonance state is 3 or less

Development and Uncertainty Evaluation of New Piston (새로운 개념의 피스톤 푸루버 개발 및 불확도 평가)

  • Choi, Hae Man;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.354-359
    • /
    • 2002
  • The new piston prover was developed and the flow measurement uncertainty of this piston prover was evaluated according to ISO/IEC 17025. The laser interferometer was employed to measure accurately the testing time. Uncertainty was calculated with evaluation of various uncertainty factors affected in flow measurement. The expanded uncertainty(U) of the piston Over was $1.3{\times}10^{-3}$ (at the confidence level of $95\%$). This evaluation example will be useful in flow measurement uncertainty determination of other gas flow measurement system.

  • PDF

A Study on Technical Measures and their Application (기술척도 적용 연구)

  • Choi, Seok
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.3 no.2
    • /
    • pp.3-8
    • /
    • 2007
  • Technical Measures includes Measures of Effectiveness(MOEs), Key Performance Parameters(KPPs), Measures of Performance(MOPs) and/or Technical Performance Measures(TPMs). Technical measurement is the set of measurement activities used to provide supplier and/ or acquirer insight into progress in the definition and development of the technical solution, ongoing assessment of the associated risks and issues. This paper describes how technical measures can be applied, using the measurement process described in the previous study and shows the relationship between the various types of technical measures.

  • PDF

Development of robot work measurement by the unit motion model (단위 동작 모형에 따른 로봇 작업시간 측정법의 개발)

  • 권규식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.367-370
    • /
    • 1996
  • This study deals with the motion modeling by the unit motion of robots and the work measurement through classification of robot motions and standardization. The proposed approach is to scrutinize the Predetermined Time Standards(PTS) methods for measurement of manual tasks performed by people and the basic motions for accomplishing that tasks. And then, it constructs the unit motion models as subsets composed with the basic motions. It apply together with movements distance as a time variable, too. These results are used for the work measurements of robots by the unit motion models.

  • PDF

Development of automatic measurement system for dynamic respose time of pneumatic solenoid valve (공압밸브의 동적응답 특성측정 자동화 시스템 개발)

  • 강보식;김형의
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.974-978
    • /
    • 1991
  • Electro-pneumatic valve is an electro-mechanical device which converts electric signal into pneumatic flow mu or pressure. A measurement of dynamic response time is very important to evaluate valve performance. Dynamic response time of electro-pneumatic valve has a variation accordance with valve types, operating way and test standard. In this study, automatic measurement system of dynamic response time is composed based on test condition of dynamic response time test standard(CETOP, JIS). Also, in this study test pressure variation characteristics accordance with variation of solenoid excitation power, and we developed dynamic response measurement system enable to compare of and analyze these two characteristics.

  • PDF