• Title/Summary/Keyword: Measurement Table

Search Result 453, Processing Time 0.024 seconds

PRECISION IDENTIFICATION OF ACTUATOR DISTURBANCE PARAMETER BY FREQUENCY COMPENSATION (주파수 보정법에 의한 구동기 외란 파라미터 정밀 결정)

  • Lee Hyunho;Cheon Dong-Ik;Oh Hwa-Suk
    • Bulletin of the Korean Space Science Society
    • /
    • 2005.04a
    • /
    • pp.138-142
    • /
    • 2005
  • A reaction wheel, an actuator for satellite attitude control, produces disturbance torque and force as well as its axial control torque. The disturbances have an influence on the pointing stability of high precision satellites. The measurement of disturbances for such a satellite, therefore, is necessary. The wheel's rotation, however, causes the vibration of the table and its vibration induces measurement errors, especially large near the resonance frequency of the Measurement table. For the purpose of overcoming these defects, a calibration method using frequency compensation is suggested in this paper. Disturbance parameters are identified from data examined by frequency compensation. Measurement frequency range can be expanded far higher than the resonance frequency, since the degradation of data accuracy caused by its vibration is well alleviated even in the resonance area.

  • PDF

Measurement of Five DOF Motion Errors in the Ultra Precision Feed Tables (초정밀 이송테이블의 5 자유도 운동오차 측정)

  • Oh Yoon Jin;Park Chun Hong;Hwang Joo Ho;Lee Deug Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.135-141
    • /
    • 2005
  • Measurement of five DOF motion errors in a ultra precision feed table was attempted in this study. Yaw and pitch error were measured by using a laser interferometer and roll error was measured by using the reversal method. Linear motion errors in the vertical and horizontal directions were measured by using the sequential two point method. In this case, influence of angular motion errors was compensated by using the previously measured ones by the laser interferometer and the reversal method. The capacitive type sensors and an optical straight edge were used in the reversal method and the sequential two point method. Influence of thermal deformation on sensor jig was investgated and minimized by the periodic measurement according to the variation of room temperature. Deviation of gain between sensors was also compensated using the step response data. 5 DOF motion errors of a hydrostatic table driven by the linear motor werer tested using the measurement method. In the horizontal direction, measuring accuracies for the linear and angular motion were within ${\pm}0.02\;{\mu}m$ and ${\pm}0.04$ arcsec, respectively. In the vertical direction, they were within ${\pm}0.02{\mu}m$ and ${\pm}0.05$ arcsec. From these results, it was found that the introduced measurement method was very effective to measure 5 DOF motion errors of the ultra precision feed tables.

Calibration of index tables using electric comparators (전기 마이크로미터를 이용한 회전 눈금원판의 교정)

  • Nam, Ki-Chul;Woo, In-Hun;Kim, Jong-Su;Lim, Jae-Sun;Chung, Myung-Se
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.4
    • /
    • pp.36-42
    • /
    • 1987
  • Very accurate calibration is needed to index tables which are necessary for precision angle measurement. The repeatability of index table is less than 0.2 second, so that attentions should be paid to choosing devices to be used in the calibration of index tables. The auto- collimators have been used in the calibration of index tables, but the repeatability of auto- collimators is bad compared with that of index table. In place of autocollimators, we described a method which uses electric comparators which are possessed by most precision measurement laboratories. Electric comparators are set to measure small angle displacement without interrupting the rotation of index tables and the signals of two electric comparators are added to remove the run-out errors of the shafts of index tables. Two index tables have been calibrated simulataneously by this method and the measurement data have been analyzed by the least squares method. We compare the calibration results with those of methods using autocollimator and auto- matic autocollimator and are able to know that the data of electric comparator method lie between the data of autocollimator methods. The repeatability of measurement is less than 0.02 second. The electric comparator method is economical and capable of reducing the uncertainty of the measurement.

  • PDF

A study on roundness measurement errors according to measurement conditions (측정조건에 따른 진원도 측정오차에 대한 연구)

  • Jung, Hyun-Suk;Hong, Cheong-Min;Choi, Ji-Sun
    • Design & Manufacturing
    • /
    • v.13 no.4
    • /
    • pp.51-56
    • /
    • 2019
  • Due to industrial development, the importance of GD&T tolerance is growing day by day. Roundness measurement means the size deviated from the ideal circle. Roundness evaluation methods include LSCI, MZCI, MCCI, and MICI. Generally, A is used a lot at industrial evaluation. In this experiment, we studied the variations in table velocity, filter values, and detector angles, which can cause errors in roundness measurements. The measurement conditions were table speeds of 10, 30 and 60 mm/s, probe angles of 10, 20 and 30 degrees and frequency filter settings of 15, 150 and 500 upr and The number of experiments was measured 30 and the average value was chosen as a representative value. The hypothesis test showed that the p-value for the frequency filter was greater than 0.05, and the experiment rejected the null hypothesis and adopted the alternative hypothesis.

Compensation techniques for experimental errors in real-time hybrid simulation using shake tables

  • Nakata, Narutoshi;Stehman, Matthew
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1055-1079
    • /
    • 2014
  • Substructure shake table testing is a class of real-time hybrid simulation (RTHS). It combines shake table tests of substructures with real-time computational simulation of the remaining part of the structure to assess dynamic response of the entire structure. Unlike in the conventional hybrid simulation, substructure shake table testing imposes acceleration compatibilities at substructure boundaries. However, acceleration tracking of shake tables is extremely challenging, and it is not possible to produce perfect acceleration tracking without time delay. If responses of the experimental substructure have high correlation with ground accelerations, response errors are inevitably induced by the erroneous input acceleration. Feeding the erroneous responses into the RTHS procedure will deteriorate the simulation results. This study presents a set of techniques to enable reliable substructure shake table testing. The developed techniques include compensation techniques for errors induced by imperfect input acceleration of shake tables, model-based actuator delay compensation with state observer, and force correction to eliminate process and measurement noises. These techniques are experimentally investigated through RTHS using a uni-axial shake table and three-story steel frame structure at the Johns Hopkins University. The simulation results showed that substructure shake table testing with the developed compensation techniques provides an accurate and reliable means to simulate the dynamic responses of the entire structure under earthquake excitations.

A study on the Economic Impact of Measurement Standards on the Advancement of Korean Industry - with case study on measuring equipment industry - (측정표준의 국내 산업성장에 대한 기여도 분석 - 측정기기산업의 분석을 중심으로 -)

  • Ahn, Ung-Hwan;Park, Byoung-Sun;Cho, Youn-Sang
    • Journal of Korea Technology Innovation Society
    • /
    • v.10 no.2
    • /
    • pp.361-382
    • /
    • 2007
  • As the Korea's economy grows bigger and its industrial structure advances, demands of high quality product become increasing. And the technology becomes to be more important factor than labor power and capital. And, the development of technology plays the key role in promoting the competitiveness of a nation. Measurement means 'Measuring with instrument', dissemination of measurement standards related with dissemination and distribution of measuring instrument. Measurement technology has been known to be the main factor of economic growth and technological development. National measurement standards is one of these factors of measurement technology. Therefore, in order to enhance dissemination of measurement standards to industry, we have to define its economic impact. We analysed the economic impact of measurement standards in terms of its contribution to the product induction of industry and management results using I-O Table with the quantitative data. The results from this study show that the increasement of measurement standards dissemination is in complementary relation with the productivity of various industries, assembly manufacturing, in particularly.

  • PDF

Orientation Correction of a Cylinder for Surface-Profile Measurement (원통 축 방향의 표면거칠기 측정을 위한 시료의 자세 보정)

  • 조남규
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.5 no.4
    • /
    • pp.108-120
    • /
    • 1996
  • A new technique and theory are proposed which correct orientation of a cylinder to perform a reliable measurement of the surface profile. We analyze characteristics of machined surfaces, e.g., ground, lapped and turned surfaces. Based upon the results. the optimum correction technique is derived by the statistical method. To verify the techinques, measurements are carried out by using the contact stylus profilometer on a controllable table. The measurement shows that surface information of cylinders can be acquired with high accuracy.

  • PDF

Active Control of Vibration Isolation Table Using Air-spring (공기스프링을 이용한 방진테이블의 능동 제어)

  • An, Chae-Hun;Yim, Kwang-Hyeok;Jin, Kyong-Bok;Rim, Kyung-Hwa
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.565-571
    • /
    • 2007
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.