• Title/Summary/Keyword: Measurement Table

Search Result 453, Processing Time 0.027 seconds

A study on the determination of width on designing bodice and skirt pattern (보디스 및 스커트원형설계시 폭결정에 관한 연구)

  • 손희정;손희순
    • Proceedings of the ESK Conference
    • /
    • 1993.10a
    • /
    • pp.205-219
    • /
    • 1993
  • The purpose of this study was to determine maximal width of bodice and skirt pattern of 50 college girls for more scientific patternmaking development in clothing construction. The body measurements data of this study was calculated by SAS, means analysis, regression analysis and T-test were used. The results are as follows. 1. The results of analyzing the whole 85 items of the entire body measurements of model are in table 2. 2. It was suggested the whole average cross section of measurement parts by rohrer index as the result of gathering the each section. 3. Representative items were suggested as fundamental parts in determining the maximal width of bodice and skirt basic pattern by rohrer index. 4. The entire abbreviated calculation formula of bodice and xkirt pattern was suggested.

  • PDF

An Study on the Erosion Characteristics of Tube CN98 (CN98 포신의 마모특성 연구)

  • Kim, Jae-Kab
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.42-52
    • /
    • 2006
  • Tube erosion can be defined as a phenomenon for an increment of bore diameter, a declination of accuracy and utility of tube by firing. This study introduces the characteristics of tube life for the 155 mm K9 SHP Using a tube history book with bore measurement data and firing data of standard charge, this study analyzed the EFC vs Tube life and EFC with heat transfer effect formula as a consideration of continuous firing vs tube life. The results were compared with Firing Table(FT 155-K9-1) after the analysis. Also, this study suggests that CN98 tube can be rifled as 1000 EFC through the severe condition with continuous firing.

Standardization of the Recipe for the Large-scale Production of Salbob and Ogokbob (쌀밥, 오곡밥의 대량생산 표준레시피 개발)

  • Han, Kyung-Soo;Pyo, Seung-Hui
    • Korean journal of food and cookery science
    • /
    • v.24 no.5
    • /
    • pp.682-690
    • /
    • 2008
  • The principal objective of this study was to develop a standardized recipe for the large-scale production of Salbob and Ogokbob. The recipe was standardized as follows: we collected and recorded the amount of ingredients and production procedures currently being used by cooks in the contracted foodservice management company and hotel-based Korean restaurants. According to the food preferences of Koreans, we selected 2 kinds of rice; Salbob and Ogokbob. We developed a revised recipe and an evaluation form. We conducted a sensory evaluation with 30 panels, using a JAR (just-about-right) scale. We developed a standardized recipe for both kinds of rice. Yield, portion size, temperature, preparation time, equipment, cost, ingredients, weight of ingredients, method, and critical point were all components accounted for in the developed recipe. The factor method and the percentage method were proposed techniques for adjusting the recipe, and a direct measurement table for Salbob and Ogokbob was also devised.

A Non-contact Shape Measuring System Using an Artificial Neural Network

  • Jeong, Woo-tae;Lee, Myung-Chan;Koh, Duck-joon;Cho, Hyung-suck
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.399-404
    • /
    • 1996
  • We developed a non-contact shape measuring device using computer image processing technology. We present a method of calibrating a CCD video camera and a laser range finder which is the most important step toward making an accurate shape measuring system. An artificial neural network is used for the calibration. Our measurement system is composed of a semiconductor laser. a CCD video camera, a personal computer, and a linear motion table. We think that the developed system could be used for measuring the change in shape of the spent nuclear fuel rod before and after irradiation which is one of the most important tasks for developing a better nuclear fuel. A radiation shield is suggested for the possible utilization of the range finder in radioactive environment.

  • PDF

LOS Stabilization Controller Design of EOTS and Performance Prediction Using Disturbance Model (EOTS 시선안정화 제어기 설계와 외란모델을 이용한 성능예측)

  • Hongwon Kim;Solyi Han;Jungwoong Jang;Kibeom Song
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.72-82
    • /
    • 2023
  • The EOTS(Electro Optical Tracking System) must have stabilization performance to provide high-quality images under disturbance environment. In this paper, we present a controller that can minimize the LOS error and has a simple structure. Hence, to evaluate the performance of this controller, analysis in the frequency domain and LOS error measurement are performed. In order to measure the LOS error without a 'rate table' that requires a lot of facility investment, we propose a design method for disturbance model that considers the operating environment of the EOTS. Finally, the performance of the stabilization algorithm is evaluated by the proposed disturbance model.

Short Distance ASF Measurement by using 9930M Loran Signal (9930M Loran신호 이용 근거리 ASF 측정)

  • Yang, Sung-Hoon;Lee, Chang-Bok;Lee, Jong-Gu;Kim, Young-Jae;Lee, Sang-Jeong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.370-371
    • /
    • 2010
  • The Long Range Navigation (LORAN) had been mainly used world-wide until GPS (Global Positioning System) activation. In particular. it was essential junctionality for the ships to sail the oceans. However, according to the industry's developing, the current accuracy of Loran is insufficient for the utilization such as the harbour approach, the land navigation and the field of precise timing. Therefore it is necessary the study on the improvement of the positioning accuracy of Loran. The method of its improvement is to measure and compensate the propagation time delay, that is, additional secondary factor (ASF) between the transmitter and user's receiver. This study shows the technique for the absolute time delay measurement without a time of coincidence (TOC) table, and represents the ASF measurement result between Pohang transmitter station(9930M) and each measure points.

  • PDF

Estimation of Attributable Burden due to Premature Death from Smoking in Korea (우리 나라 흡연으로 인한 조기사망의 질병부담)

  • Ha, Beom-Man;Kang, Jong-Won;Chang, Hye-Chung;Yoon, Seok-Jun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.191-199
    • /
    • 2001
  • Objective : In this study, we focused on estimating the burden of premature death in Korea caused by smoking using the YLL(years of life lost due to premature death) measurement. Methods : First, we determined parameters: such as age-specific standard life expectancy, age on death, sex, and cause of death by analyzing the national death certificate data and life table collected during 1997. These were provided by the National Statistical Office. Secondly, we estimated the age group- specific years of life lost due to premature death by employing the standard expected years of life lost(SEYLL) measurement. Thirdly, the burden of premature death caused by smoking was estimated using the YLLs measurement which was developed by the global burden of disease study group. Fourthly, We calculated the risk related to smoking using the population attributable risk. Results : The following results were obtained in this study: 1) Premature death that is attributable to smoking in males could be prevented in 60.9%(513,582 person-year) by non-smoking. 2) The burden of premature death by smoking for female was prevented to 17.7%(513,582 person-year) by non-smoking. Conclusion : We found that the YLL method employed in this study was appropriate in quantifying the burden of premature death. This provides a rational basis for planning a national health policy regarding premature deaths caused by smoking and other related risk factors.

  • PDF

Precise Speed Control of Direct Drive PMSM for the Cogging Torque Measurement System (코깅토크 측정장치 직접구동용 영구자석 동기전동기의 정밀속도 제어)

  • Park, Cheol-Hoon;Son, Young-Su;Ham, Sang-Yong;Kim, Byung-In;Yun, Dong-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.79-86
    • /
    • 2009
  • Recently PMSM(Permanent magnet synchronous motor) are used for the various direct drive applications such as index table, telescope system and so on. Because the position/speed control performance of direct drive PMSM is directly affected by the torque ripple, there are lots of studies to reduce the cogging torque in the motor design stage. In order to verify the motor design, the reliable cogging torque measurement system is essentially required. The measured motor must be rotated in the constant speed under 1deg/sec so that the cogging torque profile is measured correctly. In this study, the cogging torque measurement system which uses the direct drive PMSM and the speed controller to rotate the measured motor in 0.1rpm(0.6deg/sec) has been developed. Simulink/xPC target was used for the controller and data acquisition system. Based on PI controller, DOB and AFC have been applied to eliminate the low frequency disturbances and the periodic speed ripple. The experimental results show the good performance of the speed regulation for the reference speed 0.1rpm and the reliable profile of the measured cogging torque by the developed speed controller.

Estimation of uncertainty for the determination of residual flubendazole in pork (돼지고기 중 플루벤다졸 잔류분석의 불확도 추정)

  • Kim, MeeKyung;Park, Su-Jeong;Lim, Chae-Mi;Cho, Byung-Hoon;Kwon, Hyun-Jeong;Kim, Dong-Gyu;Chung, Gab-Soo
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.2
    • /
    • pp.139-145
    • /
    • 2007
  • Measurement uncertainty could play an important role in the assessment of test results in laboratories and industries. We investigated measurement uncertainties possibly included in determination of flubendazole, a benzimidazole anthelmintic, in pork by HPLC. The concentration of flubendazole was 62.69 ng/g in a sample of pork. Uncertainty was estimated in the analytical procedure of flubendazole. A model equation was made for determination of flubendazole in pork. The four uncertainty components such as weight of sample, volume of sample, calibration curve, and recovery were selected to estimate measurement uncertainties. Standard uncertainty was calculated for each component and all the standard uncertainties were combined. The combined standard uncertainty was expanded to a sample population as an expanded uncertainty. The expanded uncertainty was calculated using k value on Student's t-table and effective degrees of freedom from Welch-Satterthwaite formula. The expanded uncertainty was calculated as 3.45 with the combined standard uncertainty, 1.584 6 and the k value, 2.18. The final expression can be ($62.69{\pm}3.45$) ng/g (confidence level 95%, k = 2.18). The uncertainty value might be estimated differently depending on the selection of the uncertainty components. It is difficult to estimate all the uncertainty factors. Therefore, it is better to take several big effecting components instead of many small effecting components.

Measurement of Liquid Oscillation in Tuned Liquid Dampers using a Laser Doppler Vibrometer (레이저진동계를 사용한 동조액체댐퍼의 액체 진동 측정)

  • Shin, Yoon-Soo;Min, Kyung-Won;Kim, Junhee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.513-519
    • /
    • 2016
  • In this study, dynamic vertical displacement of liquid in the tuned liquid column damper(TLCD) is measured by a laser Doppler vibrometer(LDV) to overcome limitations of existing sensors and to leverage noncontact sensing. Addressing advantages of noncontact measurements, operational principles of the LDV to measure velocity and displacement of a target object in motion is explained. The feasibility of application of the LDV to measurement of liquid motion in the TLCD is experimentally explored. A series of shake table tests with the TLCD are performed to determine requirements of application of the LDV. Based on the experimental results, it is proved that the LDV works under the condition of adding dye to the liquid by increasing the intensity of reflected laser and thus validity is verified by comparison with a conventional wave height meter.