• Title/Summary/Keyword: Measurement Standard

Search Result 3,526, Processing Time 0.034 seconds

Analysis of Distance Measurement Accuracy in Aerial and Satellite Image Photogrammetry (항공사진측량과 위성영상측량에서 거리측정 정확도 연구)

  • Kim, Hyung-Moo;Tcha, Dek-Kie;Nam, Guon-Mo;Yang, Chul-Soo
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.253-255
    • /
    • 2010
  • Needs to study on distance measurement accuracy in aerial and satellite photogrammetry are rapidly increased. However, conventional studies show some confused definitions between measurement accuracy and measurement precision as well as standard deviation(STDEV) and root mean square error(RMSE or RMSD). So, Finite definitions of measurement accuracy and measurement precision as well as STDEV and RMSD are addressed in this paper. Experiment result show using correct definitions improve the distance measurement accuracy in aerial and satellite photogrammetry rapidly, but not the distance measurement accuracy in aerial and satellite photogrammetry.

  • PDF

System Construction and Data Development of National Standard Reference for Renewable Energy - Model-Based Standard Meteorological Year (신재생에너지 국가참조표준 시스템 구축 및 개발 - 모델 기반 표준기상년)

  • Boyoung Kim;Chang Ki Kim;Chang-yeol Yun;Hyun-goo Kim;Yong-heack Kang
    • New & Renewable Energy
    • /
    • v.20 no.1
    • /
    • pp.95-101
    • /
    • 2024
  • Since 1990, the Renewable Big Data Research Lab at the Korea Institute of Energy Technology has been observing solar radiation at 16 sites across South Korea. Serving as the National Reference Standard Data Center for Renewable Energy since 2012, it produces essential data for the sector. By 2020, it standardized meteorological year data from 22 sites. Despite user demand for data from approximately 260 sites, equivalent to South Korea's municipalities, this need exceeds the capability of measurement-based data. In response, our team developed a method to derive solar radiation data from satellite images, covering South Korea in 400,000 grids of 500 m × 500 m each. Utilizing satellite-derived data and ERA5-Land reanalysis data from the European Centre for Medium-Range Weather Forecasts (ECMWF), we produced standard meteorological year data for 1,000 sites. Our research also focused on data measurement traceability and uncertainty estimation, ensuring the reliability of our model data and the traceability of existing measurement-based data.

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hun;Lee, Chang-U
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.975-982
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed 'adequate'. The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within-part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimates are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

  • PDF

A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part (군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구)

  • Lee, Seung-Hoon;Lee, Chang-Woo
    • IE interfaces
    • /
    • v.18 no.4
    • /
    • pp.444-453
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed "adequate". The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimators are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

A Study on Bone Proportional Measurement of the Forearm (전완부의 골도분촌법에 관한 연구)

  • Min, Won-hong;Yang, Jae-Yoon;Yang, Gi-Young;Chae, Han;Lee, Byung-Ryul
    • Korean Journal of Acupuncture
    • /
    • v.35 no.4
    • /
    • pp.226-233
    • /
    • 2018
  • Objectives : The purpose of this study was to establish an accurate and effective method of locating acupoints of the forearm by studying bone proportional measurement. Methods : A total of 60 volunteers, 30 men and 30 women, participated in this study. 7 parts of the body were measured by a soft ruler or digital vernier calipers. The cun of the upper limb was calculated and analyzed. And the results were compared with the standard cun. Results : The bone proportional cun of the forearm based on height and femur was close to 11. It was different from the standard 12.5, 12 or 10. The cun of the forearm by thumb or finger width measurement was different from the standard too. Conclusions : We suggest that locating acupoints of the forearm needs to be done based on 11 cun. The confusion on locating acupoints of the forearm will be reduced by reflecting the result of the actual measurement.

A Study on the Reasonable Measurement Point of Root Collar Diameter of Landscape Trees in Korea (한국 조경수목 근원직경 측정의 합리적 위치 설정에 대한 연구)

  • Han, Yong-Hee;Kim, Hwa-Jeong;Kim, Do-Gyun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.59-70
    • /
    • 2021
  • This study was to investigate the measurement point of root collar diameter of landscape trees in Korea. It may contribute to avoiding disputes caused by the difference in measurement criteria of root collar diameter of landscape trees between tree growers and constructors. The difference between landscape trees' root collar diameter measurement point was 3.59cm from 6cm underground to the surface and 1.35cm from 0cm to 6cm above ground. The source root collar diameter measurement point difference was larger in the basement than in the ground. The standard deviation of the root collar diameter of the landscape tree was 0.64 from 6cm underground to the surface, and the difference in standard deviation from 0cm to 6cm above ground was 0.16. The difference by measurement point of the root collar diameter was larger in the basement than in the ground. It has been proposed to set the reasonable measurement point of the landscaping tree root collar diameter at the inflection point where the standard deviation of the tree trunk diameter is the smallest in line with the size change of the standard for each root collar diameter measurement point. By tree species, Cornus officinalis Siebold & Zucc. 18cm above the ground, Chionanthus retusus Lindl. & Paxton. 12cm above the ground, Zelkova serrata (Thunb.) Makino. 12cm above the ground, Celtis sinensis Pers. 12cm above the ground, Styrax japonicus Siebold & Zucc. 10 cm above the ground, Cornus officinalis Siebold & Zucc. 10cm above the ground, Acer palmatum Thunb. ex Murray. 6cm above the ground, Ilex rotunda Thunb. 6cm above the ground, Quercus myrsmaefolia Blume. 4cm above the ground, Lagerstroemia indica L. 2cm above the ground The above heights were shown as reasonable measurement points. The difference by landscape tree root collar diameter measurement site showed that the standard deviation was small throughout the tree species, and the reasonable average measurement point with a stable slope of the deviation was 12cm or more on average. It can be said that the reasonable measurement point of the root collar diameter of a landscape tree is set at an average of 12cm above the ground. However, recognizing 30cm, which is a familiar ruler(尺) in traditional practices, is quick, It was recommended to measure at the height of 30cm from the surface for a reasonable measurement point of the root collar diameter of a landscape tree, for the uniformity of measurement standards.

Studies on the Standardization of pH Measurement System (pH 측정 시스템의 표준화에 관한 연구)

  • Lee, Hwa Shim;Kim, Myung Soo;Kim, Jin Bok;Oh, Sang Hyup
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.4
    • /
    • pp.432-442
    • /
    • 1998
  • Since the definition of pH, $pH=-Ioga_H$ is based on a single ion activity, pH values can not be determined with measurement itself, but require an approximation method. They are derived from EMF measurement of a liquid junction free cell using hydrogen and Ag/AgCl electrodes. Primary standard materials with certified pH values can be obtained with this approximation method. Standard buffer solutions are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values can be obtained with this approximation method. Standard buffer solution are used to calibrate pH meters. Thus the accuracy of the pH values of standard buffer solutions limits the reliability of measured pH values of sample solutions. To certify the pH values, we have established the system for the primary standard measurement and certified the pH of buffer solutions in the range of 1.6∼12.5 pH unit within uncertainty of ${\pm}0.005$ pH unit.

  • PDF

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

Development of Gas Chromatography/Mass Spectrometry for the Determination of Essential Fatty Acids in Food Supplemental Oil Products

  • Ahn, Seonghee;Yim, Yoon-Hyung;Kim, Byungjoo
    • Mass Spectrometry Letters
    • /
    • v.4 no.4
    • /
    • pp.75-78
    • /
    • 2013
  • A gas chromatography/mass spectrometric (GC/MS) method was developed as a candidate reference method for the accurate determination of essential fatty acids (linoleic acid, ${\alpha}$- and ${\gamma}$-linolenic acids) in food supplemental oil products. Samples were spiked with three internal standards (stearic acid-$d_{35}$, $^{13}C_{18}$-linoleic acid, and $^{13}C_{18}$-${\alpha}$-linolenic acid). Samples were then subject to saponification, derivatization for methylation, and extraction by organic solvent. For GC/MS measurement, an Agilent HP-88 column, designed for the separation of fatty acid methyl esters, was selected after comparing with other columns as it provided better separation for target analytes. Target analytes and internal standards were detected by selected ion monitoring of molecular ions of their methyl ester forms. The GC/MS method was applied for the measurement of three botanical oils in NIST SRM 3274 (borage oil, evening primrose oil, and flax oil), and measurement results agreed with the certified values. Measurement results for target analytes which have corresponding isotope-labeled analogues as internal standard were calculated based on isotope dilution mass spectrometry (IDMS) approach, and compared with results calculated by using the other two internal standards. Results from the IDMS approach and the typical internal standard approach were in good agreement within their measurement uncertainties. It proves that the developed GC/MS method can provide similar metrological quality with IDMS methods for the measurement of fatty acids in natural oil samples if a proper fatty acid is used as an internal standard.

Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution (수경배양액 무기성분농도 측정장치 개발)

  • Heo, Jeong-Wook;Park, Kyeong-Hun;Hong, Seung-Gil;Lee, Jae-Su;Baek, Jeong-Hyun;Park, Jong-Taek;Lee, Seung-Kee
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.4
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.