• Title/Summary/Keyword: Measurement Control

Search Result 6,081, Processing Time 0.034 seconds

A Technique and software of analysis and control for measurement process

  • Zhao, Fengyu;Xu, Jichao;Bergman, Bo
    • International Journal of Quality Innovation
    • /
    • v.1 no.1
    • /
    • pp.97-105
    • /
    • 2000
  • In this paper, a two-section method for measuring is introduced and the variation sources of measurement process are analysed. Measuring is a special process in general process. Various variation source must be firstly decomposed so that the statistical distribution law of measuring process can be established, and then implement monitoring control of the measuring process. A special method to obtain the measuring variation is discussed, and a monitoring control technique for measuring process is studied based statistical distribution. Towards the end, we briefly introduce software design for the analysis and control of a measurement process.

  • PDF

A Comparative Study for Odor Control Regulations (악취관리제도의 국가간 비교연구)

  • 양성봉;김석만
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.79-87
    • /
    • 2000
  • This study analyzed the regulations concerning odor management or control in Korea, Japan, and developed countries such as USA and Germany. The Korean restriction standards and measurement methods for offensive odor substances are very similar to the Japanese standards and methods promulgated in 1976. Japan promulgated the odor control act and the specific measurement methods of the offensive odor substances in 1973. In Japan, currently, the local governments can establish their own odor restriction areas and proclaim their own standards suitable for their situations. Also, Japan has more strict regulations and more offensive odor substances to be monitored than Korea. The restriction standards of odor in German is quite similar to the permissible limits and standards of air pollutants at emission sources in Korea. Many states in USA are adopting their own restriction standards and measurement methods, e.q., the ambient air pollution standards, organic functionstest methods by dilation, and establishment and addition of air pollution control equipment at emission sources. Finally, this study analyzed the problems of the regulations, standards, and measurement methods concerning the Korean offensive odor management. Since the direct organic fuctions measurement(DOFMM) method is depending upon the personal sensitives of odor substances, the measurement odor value can be equivocal. That is, the odor measurement value by an examines can differ from that by the other examines. Also, there can be conflicts with the measured odor values depending upon the applied measurement methods, e.q., the DOFMM, the dilation method, and the instrumental analysis method.

  • PDF

The Economic Design of $\bar{x}$ -S Chart Considering Measurement Error (측정오차를 고려한 $\bar{x}$ -S 관리도의 경제적 설계)

  • 유영창;강창욱
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.23 no.61
    • /
    • pp.89-98
    • /
    • 2000
  • For statistical process control, the process data are collected by the measurement system. But, the measurement system may have instrument error or/and operator error. In the measured values of products, the total observed variance consists of process variance and variance due to error of measurement system. In this paper, we design more practical T-s control chart considering estimated measurement error The effects of measurement error on the expected total cost and design parameters are investigated.

  • PDF

An Output Feedback Controller for a Ball and Beam System under Measurement Noise of Feedback Sensor (센서에 측정에러가 있는 볼-빔 시스템의 출력 궤환 제어기)

  • Kim, Hyun-Do;Choi, Ho-Lim
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.10
    • /
    • pp.955-959
    • /
    • 2011
  • In this paper, we assume that an output sensor of a ball and beam system is coupled with AC measurement noise. We propose an output feedback controller for a ball and beam system under measurement noise of feedback sensor. Measurement noise makes feedback signals distorted, and results in performance degradation or even system failure. Therefore, we need to design a robust controller to accommodate the possible measurement noise in the feedback information. Our controller is equipped with a gain-scaling factor to minimize the effect of measurement noise in output feedback information. We give an analysis of the controlled system and illustrate the improved control performance via simulation and experiment for a ball and beam system.

Web-Based Remote Control & Measurement Systems (웹기반 원격 제어 및 계측 시스템 개발)

  • Jin, Gil-Ju;Lee, Myong-Il;Heo, Seok;Kwak, Moon-Kyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.836-841
    • /
    • 2002
  • This paper is concerned with the development of remote control and measurement systems system using the internet. Recently, various techniques are developed based on the advance of the internet environment. In this study, we developed the remote control and measurement system using the internet server programming technique, stepper motor control and the data acquistion programming techniques. Hence, we can perform measurement and control remotely. The feasibility of the system is validated using the experimental setup. A personal computer is equipped with the stepping motor controller which control the weight and the A/D board which measures the strain of the beam, server program was then installed on the PC and can be accessed through internet.

  • PDF

Process Control Based on the Incomplete Measurement Data Obtained from 100% Inspection (전수검사에서 얻어진 불완전한 측정 데이터를 사용한 공정관리)

  • Kwon, Hyuck-Moo
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.2
    • /
    • pp.84-92
    • /
    • 2004
  • A process control procedure is proposed when 100% inspection is performed in a process with excellent capability. Only the incomplete measurement data is assumed to be available, i.e. the specific measurement value of the quality characteristic is not available for each item but it can be determined to be smaller or larger than any prescribed value. In the suggested model, a signal limit is introduced to determine whether the process under study is in control or not. If the quality characteristic of an incoming item exceeds the upper signal or the lower signal limit, the process is determined to be stopped or not by comparing the number of consecutively accepted items with a predetermined threshold number. The procedure is designed based on the type I and II errors. The performance of the model is evaluated by the expected number of items produced under the in-control and out-of-control states until the process is stopped.

A Study on the Evaluation of Lighting Energy Consumption by Control Strategy of the Electric Lighting (전기조명 제어 전략에 따른 조명에너지 소비량 평가에 관한 연구)

  • Yun, Gyeong;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.119-125
    • /
    • 2012
  • The objective of this study is to evaluate the electric lighting energy consumption carried out by Daysim program. A comparison between the measurement and simulated exterior global horizontal illuminance shows differences about 10% and it is very similar to the measurement. The interior illuminance simulated by Daysim are 18.9% lower than the measurement and simulated lighting energy consumption is 10% lower than the measurement. Corrected annual lighting energy simulation results show that the best case is the combination of occupancy switch-off and dimming system with automatic controlled blinds (E-3). In case of no blinds, it occasionally derives the minimum lighting energy consumption but it causes the glare, so we need to be careful for choosing the control strategy. For the overcast sky, the lighting energy consumption is not changed significantly by control strategy while the lighting energy in the clear sky is changed noticeably. So we must know the right strategy for each case to control the electric lights and blinds.

Design of On-line Process Control with Variable Measurement Interval

  • Park, Changsoon
    • Journal of the Korean Statistical Society
    • /
    • v.29 no.3
    • /
    • pp.319-336
    • /
    • 2000
  • A mixed model with a white noise process and an IMA(0,1,1) process is considered as a process model. It is assumed that the process is a white noise in the absence of a special cause and the process changes to an IMA(0,1,1) due to a special cause. One useful scheme in measuring the process level is to use the variable measurement interval (VMI) between measurement times according to the value of the previous chart statistic. The advantage of the VMI scheme is to measure the process level infrequently when in control to save the measurement cost and to measure frequently when out of control to save the off-target cost. This paper considers the VMI scheme in order to detect changes in the process model from a white noise to an IMA(0,1,1). The VMI scheme is shown to be effective compared to the standard fixed measurement interval (FMI) scheme in both statistical and economic contexts.

  • PDF

A comparative study on the performance of pumping station by changing measurement methods and operational logic (빗물펌프장 계측방식과 운영 로직에 따른 거동 비교 연구)

  • Lee, Gunyoung;Beak, Hyunwook;Ryu, Jaena;Kim, Taehyoung;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.915-925
    • /
    • 2012
  • On-off control performance of target pumping station was experimented by changing measurement methods for storage level or inflow and operating logic for control system setting. Four scenarios with different measurement methods and operational logic were examined in the Matlab/Simulink environment. Controller's on-off control repetition that was frequent before has been reduced and more effective and stable system operation was found to be possible with the scenarios. Moreover, defensive operation enforced prevention of floods by changing measurement methods enabled economic operation that made an utmost use of storage volumes.