• Title/Summary/Keyword: Mean Reduction Method

Search Result 553, Processing Time 0.029 seconds

Open Reduction of Proximal Interphalangeal Fracture-Dislocation through a Midlateral Incision Using Absorbable Suture Materials

  • Lee, Jae Jun;Park, Hyoung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.397-402
    • /
    • 2013
  • Background Fracture-dislocation of the proximal interphalangeal (PIP) joint is a relatively common injury. Various treatments for fracture-dislocation of the PIP joint have been reported. In the present study, we performed open reduction through a midlateral incision using absorbable sutures to reduce the small bone fragments and performed volar plate repair. Methods We treated nine patients with fracture-dislocation of the PIP joint with small fractured bone fragments too small for pinning or screw fixation. Patients with volar plate injury were treated with open reduction and volar plate repair at the periosteum of the middle phalangeal bone base by the modified Kessler method using absorbable sutures. All patients were placed in a dorsal aluminum extension block splint, which maintained the PIP joint in approximately 30 degrees of flexion to avoid excessive tension on the sutured volar plate. Results At a mean final follow-up of postoperative 9 months, all patients were evaluated radiographically and had adequate alignment of the PIP joint and reduction of the displaced bone fragments. Range of motion was improved and there were no complications. Conclusions This technique is an excellent alternative to the current method of treating patients with fracture-dislocations that include small fragments that are too small for pinning or screw fixation. It is a less invasive surgical method and enables stable reduction and early exercise without noticeable complications.

Ship Sewage Treatment Using Fixed Media Method (고정식 메디아법을 이용한 선박의 오폐수 처리)

  • Han, Sang-Hwa;Lee, Dea-Ho;Nyung, Bu-Nyung;Bae, Sang-Bum;Yoon, Jong-Mun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.13 no.2
    • /
    • pp.99-104
    • /
    • 2010
  • The purpose of this study is to develop Sewage Treatment Plant that treat sewage which occurred in ship using fixed media method and to consider applicable to the Pilot Scale device of the STP regulations in MLTM(Ministry of Land, Transport and Maritime Affairs) and MEPC(Marine Environment Protection Committee). In test results, pH geometric mean was 7.68, $BOD_5$(Biochemical Oxygen Demand) geometric mean was 7.28 mg/l, $COD_{cr}$(Chemical Oxygen Demand) geometric mean was 48.39 mg/l, TSS(Total Suspended Solid) geometric mean was 18.00/l, Residual chlorine geometric mean was 0.19 mg/l, and E. coli geometric mean was 1CFU/100 ml. In addition, about 97.4% of $BOD_5$ was reduced, the $COD_{cr}$ reduction averaged 96.4%and the TSS reduction averaged 97.6%. STP have been determined by the MLTM and MEPC regulation of the marine pollution prevention equipment for performance testing product.

CORRELATION OF CONDYLAR MOBILITY AND ARTHROTOMOGRAPHY IN PATIENTS WITH INTERNAL DERANGEMENTS OF THE TEMPOROMANDIBULAR JOINT (측두하악관절내장증에서 하악과두운동과 측두하악과절조영상의 상호관계)

  • Lee Eun-Sook;You Dong-Soo;Park Tae-Won;Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1994
  • Arthrography of the temporomandibular joint is a useful method of demonstrating the soft tissue abnormalities related to disc dysfunction. In this study, 19 asymptomatic joints, 31 joints with anterior disc displacement with reduction, 31 joints with anterior disc displacement without reduction which were classified by arthrotomography under fluoroscopy were evaluated to determine the linear measurement of anterior recess of inferior joint space and the relationship between the condylar anterior translation and the severity of the internal derangements. Their fluoroscopic images were also evaluated to describe the characteristics of condylar paths in internal derangements of the temporomandibular joints. The results were as follows; 1. The mean lengths of the anterior recess in asymptomaic group. reduction group. and non-reduction group were 8.7±1.6㎜. 11.2±1.7㎜, 12.8±1.7㎜ respectively. The length of the anterior recess was increased according to the severity of the internal derangements(P<0.05). 2. Linear measurements of anterior movement of condyle on maximum mouth opening were 13.1 ±4.2㎜, 15.9±4.1㎜, 5.0±3.7㎜ in asymptomatic group. reduction group, and non-reduction group respectively. Compared with asymptomatic group, reduction group showed hypermobolity of the condyle and non-reduction group showed hypomobility. 3. Condyles moved beyond the crest of articular eminence in 80% of reduction group and did not reach it in 70% of non-reduction group. 4. The condyle moved mainly superiorly in reduction group(66%) and horizontally in asymptomatic group(47%). There were no cases to move superiorly in non-reduction group.

  • PDF

The change of air lead concentrations in litharge making and smelting industries (일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화)

  • Choi, Jae-Wook;Kim, Nam-Soo;Cho, Kwang-Sung;Ham, Jung-O;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

Measurement of Optical Parameters of Biological Tissues by Using the Frequency-Domain Spectroscopy (주파수 영역 분광법을 이용한 생체의 광학계수 측정법 연구)

  • Jeon, K.J.;Yoon, G.;Kim, H.S.;Kim, W.K.;Yi, J.H.;Park, S.H.;Kim, U.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.379-382
    • /
    • 1997
  • A method for measuring optical properties of biological medium was investigated by using the frequency domain spectroscopy. When amplitude-modulated light with the frequency of several tens up to several hundred MHz propagates through a scattering medium, the phase lag and the amplitude reduction occur. The phase lag depends on the average of optical path lengths. The amplitude reduction with respect to the radial distance is influenced by the penetration depth. The mean of optical path length and penetration depth are related to optical coefficients. The phase lag and the amplitude reduction were measured based on the heterodyne detection method. The experimental data were fitted with the theoretical curves derived from diffusion theory and the absorption and scattering coefficients were calculated.

  • PDF

Nitrogen removal characteristics of pigment wastewater using PAC-A/O process (PAC-A/O 공정을 이용한 안료폐수의 질소 제거 특성)

  • Jeong, Jongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.32 no.1
    • /
    • pp.19-25
    • /
    • 2018
  • The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading $0.86kgBOD/m^3/day$, mean F/M ratio 0.072~0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3~8.7 and mean temperature $34.1{\sim}44.0^{\circ}C$. The ORP bending point knee was eventually appeared in the ORP -107 mV and $NO_3{^-}-N$ removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and $NO_3{^-}-N$ was 92.3~95.0% and 98.5~99.7%. Denitrification rate was calculated to be 1.581~1.791 mg $NO_3{^-}-N/gMLSS/hr$. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • v.22 no.1
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

An Iterative Weighted Mean Filter for Mixed Noise Reduction (복합 잡음 저감을 위한 반복 가중 평균 필터)

  • Lee, Jung-Moon
    • Journal of Digital Contents Society
    • /
    • v.18 no.1
    • /
    • pp.175-182
    • /
    • 2017
  • Noises are usually generated by various external causes and low quality devices in image data acquisition and recording as well as by channel interference in image transmission. Since these noise signals result in the loss of information, subsequent image processing is subject to the corruption of the original image. In general, image processing is performed in the mixed noise environment where common types of noise, known to be Gaussian and impulse, are present. This study proposes an iterative weighted mean filter for reducing mixed type of noise. Impulse noise pixels are first turned off in the input image, then $3{\times}3$ sliding window regions are processed by replacing center pixel with the result of weighted mean mask operation. This filtering processes are iterated until all the impulse noise pixels are replaced. Applied to images corrupted by Gaussian noise with ${\sigma}=10$ and different levels of impulse noise, the proposed filtering method improved the PSNR by up to 12.98 dB, 1.97 dB, 1.97 dB respectively, compared to SAWF, AWMF, MMF when impulse noise desities are less than 60%.

Effects of Sleep Pattern, Stress, Menstrual Attitude, and Behavior That Reduces Exposure to Endocrine Disrupting Chemicals on Premenstrual Syndrome in Adolescents

  • Kim, Hye Jin;Choi, So Young;Min, Haeyoung
    • Women's Health Nursing
    • /
    • v.25 no.4
    • /
    • pp.423-433
    • /
    • 2019
  • Purpose: The study aimed to examine the effects of sleep pattern, stress, and attitude towards menstruation, and behavior that causes a reduction in exposure to endocrine disrupting chemicals (EDCs) in the course of premenstrual syndrome (PMS) in female adolescents. Method: In total, 200 girls attending middle school in K city were recruited via convenience sampling between December 11 and 31, 2018, and 192 subjects were selected for the analysis. Data were analyzed using descriptive statistics, an independent t-test, ANOVA, Pearson's correlation coefficient, and multiple regression. Results: Overall, 9 (4.7%), 152 (79.2%), and 31 (16.1%) students had morning-, intermediate-, and evening-type sleep pattern, respectively. The mean scores for school-related stress were highest. Scores for stress regarding relationships with friends were the lowest. The mean score for attitudes toward menstruation was 72.33 out of 147. The mean score for behavior that led to a reduction in EDCs exposure was 56.57 out of 85. The mean scores for PMS severity were 25.30 and 38.39 out of 60. Analysis of factors affecting PMS revealed that severity of menstrual pain (β=.28), use of analgesics during menstruation (β=.17), family history of PMS (β=-.16), stress (β=.19), and behavior that reduces EDCs exposure (β=-.17) exerted significant effects on PMS. The explanatory power of these variables was 37%. Conclusion: The findings propose the necessity of a health intervention program including educational information, which can reduce PMS in adolescents, induce the behaviors which can decrease exposure to EDCs, and activities for managing the stress levels.

Energy efficient joint iterative SIC-MMSE MIMO detection (에너지 효율적 반복 SIC-MMSE MIMO 검출)

  • Ngayahala, F.C. Kamaha;Ahmed, Saleem;Kim, Sooyoung
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.1
    • /
    • pp.22-28
    • /
    • 2015
  • In this paper, we propose a new computationally efficient joint iterative multi-input multi-output (MIMO) detection scheme using a soft interference cancellation and minimum mean squared-error (SIC-MMSE) method. The critical computational burden of the SIC-MMSE scheme lies in the multiple inverse operations of the complex matrices. We find a new way which requires only a single matrix inversion by utilizing the Taylor series expansion of the matrix, and thus the computational complexity can be reduced. The computational complexity reduction increases as the number of antennas is increased. The simulation results show that our method produces almost the same performances as the conventional SIC-MMSE with reduced computational complexity.