• 제목/요약/키워드: Maximum loading capacity

검색결과 259건 처리시간 0.024초

양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구 (A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT))

  • 최용규;서정혜;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

양방향말뚝재하시험의 재하용량 기준에 관한 연구 (A Study on the Loading Capacity Standard of Bi-directional Pile Load Test (BD PLT))

  • 최용규
    • 대한토목학회논문집
    • /
    • 제28권6C호
    • /
    • pp.379-388
    • /
    • 2008
  • 대형말뚝기초의 양방향 재하시험에서 재하용량 기준이 정확하게 규정되어 있지 않다. 그래서 양방향말뚝재하시험을 수행함에 있어 많은 혼란이 발생하고 있으며 재하용량에서 최대 2배까지의 차이가 나타나고 있다. 본 연구에서는 양방향 말뚝재하시험 기준들을 고찰하였으며, 국내에서 수행된 양방향 말뚝재하시험 사례들에 기초하여 최대등가시험하중, 재하하중 증가비, 재하용량 증가비 및 설계하중 충족비를 분석하였다. 양방향 말뚝재하시험 기준은 1방향 재하용량으로 정의되어야 하며, 1방향 재하용량은 설계하중의 2배 이상 이어야 한다는 것을 알 수 있었다.

고력볼트의 변형능력을 향상시킨 강구조 보-기둥 접합부의 제안 (A Proposal of Steel Structure Beam-to-Column Connection Appling High Strength Bolt Improved in Deformation Capacity)

  • 김승구;이승재;오상훈;강창훈
    • 한국공간구조학회:학술대회논문집
    • /
    • 한국공간구조학회 2006년도 춘계 학술발표회 논문집 제3권1호(통권3호)
    • /
    • pp.182-188
    • /
    • 2006
  • This study propose cutting body portion-high strength bolts to improve deformation capacity of High strength bolts, which are the mechanical fasteners used for End-plate connection. And, we report that loading test results of steel beam-to-column connection using high deformation capacity-high strength bolts in accordance with SAC2000 loading program. As a result, the initial stiffness and the maximum strength of the connection using high deformation capacity-high strength bolts, are approximately the same in comparison with those of the end-plate connection using the existing high strength bolts. But the deformation capacity of the connection is more than twice as much as those.

  • PDF

모래지반에 매입된 날개없는 석션앵커의 인발력에 대한 원심모형실험 (Centrifuge Model Tests on the Pullout Capacity of Embedded Suction Anchor without Flanges in Sand layer)

  • 김경오;김유석;고부현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.517-520
    • /
    • 2005
  • The embedded suction anchor(ESA) is and anchor that is driven by a suction pile. The cross-sectional shape of the ESA anchor is circle. Its diameter is the same as that of the suction pile that is used to drive it into the seafloor. For the installation, the anchor is attached to the tip of the suction pile and then driven as a unit with the pile by and applied suction pressure. Once the ESA anchor reaches the desired depth, the pile is retrieved by applying a positive pressure. Finally, only the ESA anchor remains in the soil layer. This paper presents the results of centrifuge model tests to investigate ESA pullout capacity. The main parameters that have effects on the pullout capacity of ESA may include g-level, embedded depth, direction of loading, and loading point. The results of tests show that the pullout loading capacities increase as the loading point shift toward the tip of the anchors for a given loading direction. They also indicate that the loading point associated with the maximum pullout loading capacity is located at approximately 67 percent of the anchor length from the top for the horizontal load.

  • PDF

모래지반에 근입된 석션파일의 인발저항력 및 변위거동 분석 (Analysis of Load Capacity and Deformation Behavior of Suction Pile Installed in Sand)

  • 김유석;장연수
    • 한국지반공학회논문집
    • /
    • 제27권11호
    • /
    • pp.27-37
    • /
    • 2011
  • 모래지반에서 석션파일의 최대인발저항력 산정을 위한 일련의 원심모형실험이 수행되었다. 최대인발저항력 산정을 위한 실험인자인 석션파일의 인발각과 인발작용점의 위치에 대하여 실험을 수행하였다. 인발작용점의 경우 75%에서 최대인발저항력이 관찰되었다. 모든 경사각에 대하여 전체파일 높이에서 50%에서 75%사이에 석션파일의 회전각이 변함을 알 수 있었다. 인발각이 증가함에 따라 최대 인발저항력 발생 시까지의 변위가 점점 작아짐을 알 수 있었다. 석션파일의 형상중심의 수직변위를 최대인발저항력이 작용한 시점에서 관찰한 결과 모두 지표 쪽으로 이동한 것을 알 수 있었다.

모래지반에서 반복수평하중을 받는 항타말뚝의 거동 (Behavior of Laterally Cyclic Loaded Piles Driven into Sand)

  • 백규호;박원우;김영준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 세계 도시지반공학 심포지엄
    • /
    • pp.913-922
    • /
    • 2009
  • Fourteen model pile load tests using a calibration chamber and instrumented model pile were preformed to investigate the variation of the behaviors of driven piles in sands with soil and lateral cyclic loading conditions. Results of the model tests showed that the first loading cycle generated more than 70% of the pile head rotation developed for 50 lateral loading cycles. Lateral cyclic loading also made an increase of the ultimate lateral load capacity of piles for $K_0$=0.4 and an decrease for $K_0$ higher than 0.4. Higher portion of the increase or decrease in the ultimate lateral load capacity by lateral cyclic loading was generated for the first loading cycle due to densification of loosening of the soil around the pile by lateral cyclic loading. It was also observed that a two-way cyclic loading caused higher ultimate lateral load capacity of driven piles than a one-way cyclic loading. When the pile was in the ultimate state, the maximum bending moment developed in the pile increased with increasing $K_0$ value of soil and was insensitive to the magnitude and number of lateral cyclic loading.

  • PDF

Capacity of a transmission tower under downburst wind loading

  • Mara, T.G.;Hong, H.P.;Lee, C.S.;Ho, T.C.E.
    • Wind and Structures
    • /
    • 제22권1호
    • /
    • pp.65-87
    • /
    • 2016
  • The wind velocity profile over the height of a structure in high intensity wind (HIW) events, such as downbursts, differs from that associated with atmospheric boundary layer (ABL) winds. Current design codes for lattice transmission structures contain only limited advice on the treatment of HIW effects, and structural design is carried out using wind load profiles and response factors derived for ABL winds. The present study assesses the load-deformation curve (capacity curve) of a transmission tower under modeled downburst wind loading, and compares it with that obtained for an ABL wind loading profile. The analysis considers nonlinear inelastic response under simulated downburst wind fields. The capacity curve is represented using the relationship between the base shear and the maximum tip displacement. The results indicate that the capacity curve remains relatively consistent between different downburst scenarios and an ABL loading profile. The use of the capacity curve avoids the difficulty associated with defining a reference wind speed and corresponding wind profile that are adequate and applicable for downburst and ABL winds, thereby allowing a direct comparison of response under synoptic and downburst events. Uncertainty propagation analysis is carried out to evaluate the tower capacity by considering the uncertainty in material properties and geometric variables. The results indicated the coefficient of variation of the tower capacity is small compared to those associated with extreme wind speeds.

모래지반에서 재하방법이 반복수평하중을 받는 말뚝의 거동에 미치는 영향 (Effects of Loading Method on the Behavior of Laterally Cyclic Loaded Piles in Sand)

  • 백규호;김영준;이승연
    • 한국지반공학회논문집
    • /
    • 제27권3호
    • /
    • pp.63-73
    • /
    • 2011
  • 반복수평하중을 받는 말뚝의 거동은 반복하중의 크기와 재하횟수 뿐만 아니라 반복하중의 재하방법(한방향 또는 양방향 재하)에도 영향을 받는다. 본 연구에서는 반복수평하중의 재하방법이 모래지반에 타입된 항타말뚝의 거동에 미치는 영향을 조사하기 위해서 가압토조를 이용한 모형말뚝재하시험을 수행하였다. 실험결과에 따르면 반복수평하중을 한방향으로 받는 말뚝의 누적 영구수평변위는 최초 재하방향과 같은 방향으로 발생하지만, 반복하중을 양방향으로 받는 말뚝의 영구수평변위는 최초 재하방향과 반대 방향으로 발생하였다. 그리고 이와 같은 반복하중의 재하방법에 따른 말뚝 영구수평변위의 변화로 인해 한방향 반복재하는 말뚝의 반복극한수평지지력을 감소시키고 양방향 반복 재하는 말뚝의 반복극한수평지지력을 증가시켰으며, 수평하중의 반복재하횟수가 많아질수록 하중의 재하방법에 따른 말뚝의 반복극한수평지지력 차이는 더욱 확대되었다. 또한 반복수평하중의 재하방법에 따른 말뚝 주변지반의 다짐도 차이로 인해 수평하중이 반복재하되는 동안 말뚝에 발생하는 최대 휨모멘트는 반복하중이 양방향보다 한방향으로 재하되는 경우에 더 크게 나타났다. 그러나 극한상태에서 말뚝에 발생한 최대 휨모멘트는 반복하중이 한방향보다 양방향으로 재하된 경우에 그리고 반복재하를 받은 경우보다 그렇지 않은 경우에 더 큰 것으로 조사되었다.

Nitrate reduction by iron supported bimetallic catalyst in low and high nitrogen regimes

  • Hamid, Shanawar;Lee, Woojin
    • Advances in environmental research
    • /
    • 제4권4호
    • /
    • pp.263-271
    • /
    • 2015
  • In this study, the effect of initial nitrate loading on nitrate removal and byproduct selectivity was evaluated in a continuous system. Nitrate removal decreased from 100% to 25% with the increase in nitrate loading from 10 to $300mg/L\;NO_3-N$. Ammonium selectivity decreased and nitrite selectivity increased, while nitrogen selectivity showed a peak shape in the same range of nitrate loading. The nitrate removal was enhanced at low catalyst to nitrate ratios and 100% nitrate removal was achieved at catalyst to nitrate ratio of ${\geq}33mg\;catalyst/mg\;NO_3-N$. Maximum nitrogen selectivity (47%) was observed at $66mg\;catalyst/mg\;NO_3-N$, showing that continuous Cu-Pd-NZVI system has a maximum removal capacity of 37 mg $NO_3{^-}-N/g_{catalyst}/h$. The results from this study emphasize that nitrate reduction in a bimetallic catalytic system could be sensitive to changes in optimized regimes.

Effect of Biofilter Operation Parameters on Dimethyl Disulfide Removal : Loading, Time, and Concentration

  • Arpacioglu, Bora C.;Kim, Jo-Chun;Allen, Eric R.;Kim, Seoung-Hyun
    • 한국환경과학회지
    • /
    • 제11권8호
    • /
    • pp.783-791
    • /
    • 2002
  • A laboratory-scale dual-column biofilter system was used to study the biofiltration of dimethyl disulfide(DMDS). The biofiltration of DMDS was found to depend on the pollutant loadings rather than the inlet concentrations. It was estimated that the pollutant was only inhibitory to the operation of the biofilters at DMDS concentrations greater than 5500 ppmv A residence time of 30 seconds(120 m$^3$/m$^2$/h volumetric loading) was determined as appropriate for efficient operation(>90%). The maximum elimination capacity for both compost mixtures under the current experimental conditions was found to range from 7.5 to 10 g-DMDS/m$^3$/h. A lower DMDS maximum elimination capacity was exhibited under acidified conditions.