• 제목/요약/키워드: Maximum discharge pressure

검색결과 140건 처리시간 0.023초

Ion Pump Design for Improved Pumping Speed at Low Pressure

  • Paolini, Chiara;Audi, Mauro;Denning, Mark
    • Applied Science and Convergence Technology
    • /
    • 제25권6호
    • /
    • pp.108-115
    • /
    • 2016
  • Even if ion pumps are widely and mostly used in ultra-high vacuum (UHV) conditions, virtually every existing ion pump has its maximum pumping speed around 1E-6 mbar (1E-4 Pa). Discharge intensity in the ion pump Penning cell is defined as the current divided by pressure (I/P). This quantity reflects the rate of cathode bombardment by ions, which underlies all of the various pumping mechanisms that occur in ion pumps (chemisorption on sputtered material, ion burial, etc.), and therefore is an indication of pumping speed. A study has been performed to evaluate the influence of magnetic fields and cell dimensions on the ion pump discharge intensity and consequently on the pumping speed at different pressures. As a result, a combination of parameters has been developed in order to design and build an ion pump with the pumping speed peak shifted towards lower pressures. Experimental results with several different test set-ups are presented and a prototype of a new 200 l/s ion pump with the maximum pumping speed in the 1E-8 mbar (1E-6 Pa) is described. A model of the system has also been developed to provide a framework for understanding the experimental observations.

대형 2행정 디젤기관용 모터구동 실린더 주유기의 성능에 미치는 퀼 어큐뮬레이터의 영향에 관한 연구 (A Study on Effect of Quill Accumulator upon Performance of Motor-driven Cylinder Lubricator in a Large Two-stroke Diesel Engine)

  • 배명환;옥현진;정화
    • 한국자동차공학회논문집
    • /
    • 제15권2호
    • /
    • pp.115-125
    • /
    • 2007
  • Minimizing the cylinder wear and the consumption rate of cylinder oil in a large two-stroke marine diesel engine is of great economic importance. In Korea, a motor-driven cylinder lubricator for a large two-stroke marine diesel engine manufactured by $W{\ddot{a}}rtsil{\ddot{a}}$ Switzerland Co., Ltd. was first developed by authors through the joint research of industry-university in 2002. The characteristic of the developed product is that can control automatically the oil feed rate to a load fluctuation by the motor drive and the offset cam. The performance of the product is not also inferior to the conventional one. For manufacturing the reliable and useful products, however, it is necessary to investigate further characteristics and improve the performance of a cylinder lubricator. In this study, the effect of quill with and without accumulator on maximum discharge pressure, delivery delay duration and oil feed rate relative to motor revolution speed using plunger stroke as a parameter is experimentally investigated by using the developed cylinder lubricator. It is found that the maximum discharge pressure with accumulator is higher than that of no accumulator as plunger stroke and motor revolution speed are elevated, and the delivery delay duration with accumulator is shorter than that of no accumulator as plunger stroke and motor revolution speed are increased. Also, oil feed rate with accumulator is less than that of no accumulator except for a plunger stroke of 2 mm as plunger stroke and motor revolution speed are raised.

방전여기 XeCl 엑시머레이저의 제작 및 동작특성 (Development and Operation Characteristics of XeCl Excimer Laser)

  • 진윤식;이홍식;김희제;노영수;김윤택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 정기총회 및 추계학술대회 논문집 학회본부
    • /
    • pp.268-271
    • /
    • 1993
  • Discharge pumped high power excimer laser is a very useful light source of ultraviolet region. In this paper. the design and operation characteristics of UV pre-ionized discharge pumped XeCl laser are discussed. Maximum output power of 890mJ at the efficiency of 1.4% was achieved with 35kV charging voltage, 3.4atm of total pressure and 10pps of pulse repetition rate. Optimum HCl pressure is considered to be between 2.5 and 3.5torr.

  • PDF

유동분위기에서 메탄올의 연소특성에 관한 연구 (A Study on the Combustion Characteristic of the Methanol Fuel in a Turbulence Mixture)

  • 이중순;이태원;정성식;하종률
    • 대한기계학회논문집
    • /
    • 제19권8호
    • /
    • pp.2022-2029
    • /
    • 1995
  • The experiment was performed by using the condenser discharge ignition device in a constant volume combustion chamber for high pressure, equivalent to the TDC of spark ignition engine, which makes the forced turbulent field possible. The conclusions obtained under various initial pressures, initial temperatures, and turbulent conditions of the methanol-air mixture are as follows : As initial pressure, initial temperature of the mixture, and the ignition energy increase, the inflammability limit expands, but the lean inflammability limit decreases as turbulence intensity increases. Combustion duration is shorter in the case of the lower initial pressure, the higher initial temperature, an equivalence ratio of 1.1-1.2, and even though turbulence intensity increases up to optimum value. Maximum combustion pressure increases in turbulent ambience under the same mixture condition, only in the case each optimum turbulence intensity exists under every condition. As the turbulence intensity increases .tau.$_{10}$ proportion increases while the .tau.$_{pr}$ proportion decreases....

공압 실린더 액츄에이터 위치제어 (Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors)

  • 권순홍;최원식;정성원;박종민;권순구;서정덕
    • 한국기계가공학회지
    • /
    • 제10권6호
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

불평등 전계에서 $SF_6/CF_4$ 혼합가스의 절연내력과 PD특성 (Breakdown Voltage and PD Characteristics of $SF_6/CF_4$ Mixtures in Nonuniform Field)

  • 황청호;성허경;허창수
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.635-640
    • /
    • 2008
  • New gas mixtures are now finding applications such as interrupting media for high-voltage circuit breakers. These mixtures consist of a high content of carbon tetrafluoride($CF_4$) added to sulfur hexafluoride($SF_6$). Nowdays $SF_6$ has been established for the use in gas insulated substations due to its high insulation withstand level and good arc quenching capability. At this paper Breakdown characteristics were investigated for $SF_6/CF_4$ mixtures when AC voltage and standard lightning impulse voltage(LI) was applied in a needle-plane electrodes. And partial discharge(PD) experiments were carried out in the test chamber which was made in needle-plane electrode. And ${\Phi}$-Q-N distribution of partial discharge signals was analyzed. The total pressure of the $SF_6/CF_4$ mixtures was varied within the range of 0.1-0.5 Mpa in the test chamber. The breakdown voltage in needle-plane electrode displayed N shape characteristics for increasing the content of $SF_6$ at positive impulse voltage and the PD inception voltage was increased slightly when pressure of $SF_6/CF_4$ Mixtures was increased. Maximum PD inception voltage is showed in 80% SF6/20%$CF_4$.

평면 배열 유전체 장벽 방전 플라즈마 발생기의 대기압에서의 레이다 단면적 감소 효과 (Radar Cross Section Reduction by Planar Array of Dielectric Barrier Discharge Plasma under Atmospheric Pressure)

  • 김유나;김상인;김두수;이용식;육종관
    • 한국전자파학회논문지
    • /
    • 제28권8호
    • /
    • pp.646-652
    • /
    • 2017
  • 큰 부피의 플라즈마를 발생시키기 위하여 플라즈마 층을 포함하는 유전체 장벽 방전 구조(dielectric barrier discharge)를 제안하고, 발생기 동작 유무에 따른 모노스태틱 레이다 단면적(mono-static radar cross section)을 측정함으로써 대기압 플라즈마가 전자기파에 미치는 영향을 분석하였다. 다수의 전극을 평면으로 평행 배열함으로써 플라즈마 층의 부피를 증가시켰으며, 전극 배열과 수직인 방향의 전기장을 포함하는 전자기파를 입사시킴으로써 발생기와의 원치 않는 커플링을 최소화 시켰다. 실험 결과, 모노스태틱 레이다 단면적을 2 GHz부터 25 GHz까지 측정하였을 때, K band에서 최대 8 dB까지 감소하는 것을 확인하였다. 또한, 고전압 발생기의 인가 전압을 최대 20 kV까지 변화시킴으로써 원하는 주파수에서 플라즈마로 인한 감소치를 유연하게 조절 가능함을 보였다.

에나멜층 제거를 위한 미니 $CO_2$레이저의 방전특성 (Discharge Characteristics of Mini $CO_2$ Laser for Eliminating Enamel Layer)

  • 문진규;김휘영;김동현;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1903-1904
    • /
    • 1997
  • This paper was dealt with the experiments of the traverse flow and excited CW $CO_2$ Laser. The discharge and laser output characteristics of CW $CO_2$ laser has been investigated. A stable resonator was adopted for the power extraction from the length of 0.9m discharge region with the gap length of 15mm. The maximum output power of about 100W was obtained at the first experiment with the total filling pressure of 30torr, $CO_2$ : $N_2$ : He = 1:3:16.

  • PDF

전산해석을 통한 고압열증기압축기 형상변수에 관한 강건 설계 (Robust Design for Shape Parameters of High Pressure Thermal Vapor Compressor by Numerical Analysis)

  • 박일석
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.931-937
    • /
    • 2008
  • A high motive pressure thermal vapor compressor(TVC) for a commercial multi-effect desalination(MED) plant is designed to have a high entraining performance and its robustness is also considered in the respect of operating stability at the abrupt change of the operating pressures like the motive and suction steam pressure which can be easily fluctuated by the external disturbance. The TVC having a good entraining performance of more than entrainment ratio 6.0 is designed through the iterative CFD analysis for the various primary nozzle diameter, mixing tube diameter and mixing tube length. And then for a couple of TVC having a similar entrainment ratio, the changes of the entrainment ratio are checked along the motive and suction pressure change. The system stability is diagnosed through the analyzing the changing pattern of the entrainment ratio.

Analysis of the Characteristics of an Aerospike Pintle Nozzle in terms of Stroke and Operating Pressure

  • Kim, Jeongjin
    • 항공우주시스템공학회지
    • /
    • 제14권4호
    • /
    • pp.1-9
    • /
    • 2020
  • The characteristics of an aerospike pintle nozzle system with excellent altitude compensation were analyzed using cold air testing. It was confirmed that reducing the stroke of the aerospike nozzle is effective in increasing the thrust. However, the results of additional numerical analysis indicated that the discharge coefficient factor was significantly lower at the maximum stroke. The Vena contracta due to the cowl reduction angle decreased the effective nozzle throat area at the maximum stroke and hindered expansion. Complementing the cowl design may thus increase the efficiency of a solid-propellant rocket engine that uses the aerospike pintle nozzle system.