• 제목/요약/키워드: Maximum detection range

검색결과 206건 처리시간 0.026초

매크로 벤딩 측정을 위한 금속 모세관 결합 광섬유 센서 (Fiber-optic macro-bending sensor aided by metal capillary)

  • 백승인;정윤찬;이병호
    • 한국광학회지
    • /
    • 제12권4호
    • /
    • pp.289-293
    • /
    • 2001
  • 금속 모세관을 이용하여 일반적인 단일모드 광섬유를 결합함으로써 매크로 벤딩(macro bending)을 측정할 수 있는 광섬유 센서를 제작하였다. 매크로 벤딩에 의한 곡률 반지름이 감소함에 따라 각도 정렬 오차가 증가하여 투과되는 빛의 에너지가 감소하게 되므로 매크로 벤딩을 측정할 수 있었다. 측정 범위는 곡률 반지름 20mm에서 85mm의 영역이었다. 사용한 광섬유 격자의 중심 파장은 각각 1543.3 nm, 1549.5nm이고 최대 벤딩 손실을 -11.19dB였다. 이 센서와 광섬유 브래그 격자를 이용하여 다중점 측정이 가능함을 보였다.

  • PDF

Highly Selective Derivative Spectrophotometry for Determination of Nickel Using 1-(2-Pyridylazo)-2-naphthol in Tween 80 Micellar Solutions

  • Eskandari, Habibollah
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권8호
    • /
    • pp.1137-1142
    • /
    • 2004
  • A spectrophotometric and first derivative spectrophotometric method was developed in aquatic Tween 80 micellar solutions for selective determination of nickel without using any pre-separation step. 1-(2-Pyridylazo)-2-naphthol (PAN), as a sensitive chromogenic complexing agent formed a red-colored Ni(II)-PAN complex in Tween 80 media with satisfactory solubility and stability. Conditions such as pH, PAN concentration, type and concentration of micellizing agent were optimized. Molar absorptivity of Ni-PAN complex was found $4.62\;{\times}\;10^4L\;cm^{?1}\;mol^{?1}$ at 569 nm, under the optimum condition. Calibration graphs were derived by zero, first and second derivative spectrophotometry at maximum wavelengths of 569, 578 and 571 nm with linear ranges of 30-1800, 20-2500 and 30-2000 ng $mL^{?1}$ , respectively. Precision as standard deviation as well as accuracy as recovery percent were in the range of 1-20 ng $mL^{?1}$, and 93.3-103.3%, respectively, for the entire of the linear ranges. Spectrophotometric detection limit was 3 ng $mL^{?1}$ and effects of diverse ions on the first derivative determination of nickel were studied to investigate selectivity of the method. Interferences of cobalt and copper on the nickel determination were prevented using o-phenanthroline as masking agent. The recommended procedures were applied to the various synthetic and stainless steel alloys, tea leaves and human hair, with satisfactory results.

Capillary Electrochromatography with Liquid Crystal Crown Ether Modified Hybrid Silica Monolith for Analysis of Imidacloprid and Carbendazim in Tomatoes

  • Wang, Mingming;Feng, Rui;Shen, Jing;Chen, Hao;Zeng, Zhaorui
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2224-2228
    • /
    • 2012
  • This study describes the ability of capillary electrochromatography (CEC) for the determination of imidacloprid and carbendazim in tomato samples. A novel liquid crystal crown ether modified hybrid silica monolithic column was synthesized, characterized and developed as separation column for the first time. Baseline separation of imidacloprid and carbendazim could be achieved using a mobile phase containing 90% (v/v) 20 mmol/L phosphate buffer (pH 7.0) and 10% (v/v) acetonitrile. The matrix matched calibration curves were linear with correlation coefficient $r^2$ > 0.9998 in the range of 0.20-10.00 mg/L. The limits of detection for imidacloprid and carbendazim were 0.061 and 0.15 mg/kg, respectively, which were below the maximum residue limits established by the European Union as well as Codex Alimentarius. Average recoveries for imidacloprid and carbendazim varied from 101.6-108.0% with relative standard deviations lower than 6.3%. This method was applied to the analysis of tomatoes collected from local markets.

Electrochemical Investigation of Acetaminophen with a Carbon Nano-tube Composite Film Electrode

  • Li, Chunya;Zhan, Guoqing;Yang, Qingdan;Lu, Jianjie
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권11호
    • /
    • pp.1854-1860
    • /
    • 2006
  • Electrochemical behaviors of acetaminophen at a muti-wall carbon nano-tube composite film modified glassy carbon electrode were investigated by cyclic voltammetry, linear sweep voltammetry and chronocoulometry. Compared with that obtained at the unmodified electrode, the peak currents were enhanced significantly, and the oxidation peak shifted towards more negative potential with the reduction peak shifted positively. The peak-to-peak separation turned narrow, and suggested that the reversibility was improved greatly. Experimental parameters, such as scan rate, pH and accumulation conditions were optimized. It was found that a maximum current response can be obtained at pH = 5.0 after accumulation at -0.50 V for 80 s. The oxidation peak current was found to be linearly related to acetaminophen concentration over the range of $5.0{\times}10^{-7}\;\sim\;1.0{\times}10^{-4}$ mol $L^{-1}$ with a detection limit of $5.0{\times}10^{-8} $mol $L^{-1}$. A convenient and sensitive electrochemical method was developed for the determination of acetaminophen in a commercial paracetamol oral solution. Its practical application demonstrated that it has good selectivity and high sensitivity.

경원소 적층 분석을 위한 탄성되튐-비행시간 측정시스템 (An ERD-TOF System for the Depth Profiling of Light Elements)

  • 김영석;우형주;김준곤;김덕경;최한우;홍완
    • 한국진공학회지
    • /
    • 제5권1호
    • /
    • pp.25-32
    • /
    • 1996
  • An ERD-TOF system is constructed for the nondestructive depth profiling of light elements in thin films in the range of several thousand angstroms. The particles, recoiled by 10 $MeV^{35}Cl$ projectiles, were detected by a Time-Of-Flight spectrometer composed of a MCP (Micro Channel Plate) and a SSB (Silicon Surface Barrier) detector. A two parameter data acquisition system composed of two PC's was constructed for registering simultaneous time and energy signals. A $Si_3N_4$/poly-Si/$SiO_2$/Si sample was anlayzed and the result is compared with RBS. The detection limit, maximum probable depth and depth resolution for light elements in silicon are about $4\times10^{14}atoms/\textrm{cm}^2$, 5, 000$\AA$ and 100$\AA$, respectively.

  • PDF

A Study on a Dual Electromagnetic Sensor System for Weld Seam Tracking of I-Butt Joints

  • Kim, J.-W.;Shin, J.-H.
    • International Journal of Korean Welding Society
    • /
    • 제2권2호
    • /
    • pp.51-56
    • /
    • 2002
  • The weld seam tracking system for arc welding process uses various kinds of sensors such as arc sensor, vision sensor, laser displacement sensor and so on. Among the variety of sensors available, electro-magnetic sensor is one of the most useful methods especially in sheet metal butt-joint arc welding, primarily because it is hardly affected by the intense arc light and fume generated during the welding process, and also by the surface condition of weldments. In this study, a dual-electromagnetic sensor, which utilizes the induced current variation in the sensing coil due to the eddy current variation of the metal near the sensor, was developed for arc welding of sheet metal I-butt joints. The dual-electromagnetic sensor thus detects the offset displacement of weld line from the center of sensor head even though there's no clearance in the joint. A set of design variables of the sensor was determined far the maximum sensing capability through the repeated experiments. Seam tracking is performed by correcting the position of sensor to the amount of offset displacement every sampling period. From the experimental results, the developed sensor showed the excellent capability of weld seam detection when the sensor to workpiece distance is near less than 5 ㎜, and it was revealed that the system has excellent seam tracking ability for the I-butt joint of sheet metal.

  • PDF

Europium(III)와 EDTA의 3차 복합체 형성에 의한 Levodopa의 분광분석적 정량 (Spectrofluorimetric Determination of Levodopa through Ternary Complex Formation with Europium(III) and Ethylenediaminetetraacetic Acid)

  • ;;김소연;조해진;이상학;김영호;김성홍
    • 응용화학
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 2011
  • A highly sensitive spectrofluorimetric method was developed for the determination of levodopa based on the formation of a ternary complex with Eu3+ in the presence of ethylenediaminetetraacetic acid. It was found that this complex manifests intense fluorescence at 591 and 613 nm with excitation at 372 nm and maximum intensity was obtained at 613 nm. Under the optimum conditions, the enhanced fluorescence intensity was proportional to the concentration of levodopa over the range of 3×10-9-2.5×10-7 mol L-1 with limit of detection (LOD) of 4.37×10-10 mol L-1. The method offers higher sensitivity and selectivity which could be effectively applied for the determination of levodopa in pharmaceutical and biological samples.

HG-ICP-AES를 이용한 Germanium 분석에 있어서 보조산에 대한 연구 (Investigation of Acids on the Germanium Analysis by HG-ICP-AES)

  • 임현의;이연희;김선태;김영상;김강진
    • 분석과학
    • /
    • 제14권1호
    • /
    • pp.34-43
    • /
    • 2001
  • 수소화물생성법-유도결합플라스마-원자방출분광법으로 게르마늄을 분석할 때 보조산으로 phosphoric acid의 사용은 nitric acid, hydrochloric acid, sulfuric acid, perchloric acid, boric acid, tartaric acid, malic acid, oxalic acid, acetic acid, tannic acid, citric acid의 사용보다 높은 수소화물 생성효율을 보였고, 같은 pH영역이라도 phosphate ion이 존재하는 buffer의 사용이 더 높은 생성효율을 보였다. 또한, 2.5M phosphoric acid를 이용한 결과, 시료용액 내에 잔류하는 산이나 공존원소의 영향이 감소하였다. 환원제와 안정제의 농도가 증가할수록 수소화물 생성효율은 증가되었으며, 최대방출세기를 나타내는 산의 세기는 높은 쪽으로 이동했고 농도영역은 넓어졌다. 인산 존재 하에서의 게르마늄의 검출한계는 $0.03{\mu}g/L$이었다.

  • PDF

Enhanced Production, Purification, and Partial Characterization of Lacticin BH5, a Kimchi Bacteriocin Produced by Lactococcus lactis BH5

  • Paik, Hyun-Dong;Hyun, Hyung-Hwan;Pyun, Yu-Ryang;Ahn, Cheol;Hur, Ji-Woon;Kim, Tae-Seok;Yeo, Ick-Hyun
    • 한국미생물생명공학회:학술대회논문집
    • /
    • 한국미생물생명공학회 2000년도 Proceedings of 2000 KSAM International Symposium and Spring Meeting
    • /
    • pp.53-60
    • /
    • 2000
  • Strain BH5 was isolated from naturally fermented Kimchi and identified as a bacteriocin producer, which has bactericidal activity against Micrococcus flavus ATCC 10240. Strain BH5 was identified tentatively as Lactococcus lactis by the API test and some characteristics. Lactococcus lactis BH5 showed a broad spectrum of activity against most of the non-pathogenic and pathogenic microorganisms tested by the modified deferred method. The activity of lacticin BH5, named tentatively as the bacteriocin produced by Lactococcus lactis BH5, was detected at the mid-log growth phase, reached its maximum during the early stationary phase, and decreased after the late stationary phase. Lacticin BH5 also showed a relatively broad spectrum of activity against non-pathogenic and pathogenic microorganisms as tested by the spot-on-lawn method. Its antimicrobial activity on sensitive indicator cells was completely disappeared by protease XIV or ${\alpha}$-chymotrypsin. The inhibitory activities of lacticin BH5 were detected during treatments up to 100$^{\circ}C$ for 30 min. Lacticin BH5 was very stable over a pH range of 2.0 to 9.0 and was stable with all the organic solvents examined. The cell concentration and bacteriocin production in strain BH5 were maximum when grown at 30$^{\circ}C$ in a modified MRS medium supplemented with 0.5% tryptone, 1.0% yeast extract, and 0.5% beef extract as nitrogen sources. It demonstrated a typical bactericidal mode of inhibition against Micrococcus flavus ATCC 10240. Lacticin BH5 was purified through ammonium sulfate precipitation, ethanol precipitation, and CM-Sepharose column chromatography. The apparent molecular mass of lacticin BH5 was estimated to be in the region of 3.7 kDa, by the direct detection of bactericidal activity after SDS-PAGE. Mutant strain NO141 which was isolated by nitrosoguanidine mutagenesis produced about 4 fold more bacteriocin than the wild type.

  • PDF

투명한 p형 반도체 CuAlO2 박막의 일산화질소 가스 감지 특성 (Nitrogen Monoxide Gas Sensing Characteristics of Transparent p-type Semiconductor CuAlO2 Thin Films)

  • 박수정;김효진;김도진
    • 한국재료학회지
    • /
    • 제23권9호
    • /
    • pp.477-482
    • /
    • 2013
  • We investigated the detection properties of nitrogen monoxide (NO) gas using transparent p-type $CuAlO_2$ thin film gas sensors. The $CuAlO_2$ film was fabricated on an indium tin oxide (ITO)/glass substrate by pulsed laser deposition (PLD), and then the transparent p-type $CuAlO_2$ active layer was formed by annealing. Structural and optical characterizations revealed that the transparent p-type $CuAlO_2$ layer with a thickness of around 200 nm had a non-crystalline structure, showing a quite flat surface and a high transparency above 65 % in the range of visible light. From the NO gas sensing measurements, it was found that the transparent p-type $CuAlO_2$ thin film gas sensors exhibited the maximum sensitivity to NO gas in dry air at an operating temperature of $180^{\circ}C$. We also found that these $CuAlO_2$ thin film gas sensors showed reversible and reliable electrical resistance-response to NO gas in the operating temperature range. These results indicate that the transparent p-type semiconductor $CuAlO_2$ thin films are very promising for application as sensing materials for gas sensors, in particular, various types of transparent p-n junction gas sensors. Also, these transparent p-type semiconductor $CuAlO_2$ thin films could be combined with an n-type oxide semiconductor to fabricate p-n heterojunction oxide semiconductor gas sensors.