• 제목/요약/키워드: Maximum axial load

검색결과 247건 처리시간 0.026초

하악 임플란트지지 오버덴춰에서 바 어태치먼트의 유지력이 임플란트의 축력에 미치는 영향 (EFFECTS OF OVERDENTURE RETENTION ON THE AXIAL LOAD OF IMPLANT IN THE MANDIBULAR IMPLANT-SUPPORTED OVERDENTURE)

  • 조혜원
    • 대한치과보철학회지
    • /
    • 제38권1호
    • /
    • pp.98-107
    • /
    • 2000
  • Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were placed around the abutment of implant future and the maximum axial loads on the mandibular implants supporting over dentures were registered in experimental model when the overdenture was removed. The overdenture attachments used in this study were Round bar Hader bar, Dolder bar with and with out spacer. The retention of bar attachment was measured using universal testing machine while being con-trolled by Activating set and Deactivator except in case of the Hader bar. Simultaneously strains were recorded with the strain smart program in strain P-6000 series (Measurement group, Raleigh, USA). The maximum axial load was calculated and compared with each other. The results were as follows: 1. The amount and the timing of the maximum axial loads were different between the right and left implant in all attachment systems. 2. The retention of bar attachment except Hader bar could be adjusted but the controllability was different among the attachment systems. 3. The more the axial load, the higher the retention with Hader bar and Dolder bar without spacer. but the tendency of increase was not shown with round bar and Dolder bar with spacer.

  • PDF

Maximum axial load level and minimum confinement for limited ductility design of high-strength concrete columns

  • Lam, J.Y.K.;Ho, J.C.M.;Kwan, A.K.H.
    • Computers and Concrete
    • /
    • 제6권5호
    • /
    • pp.357-376
    • /
    • 2009
  • In the design of concrete columns, it is important to provide some nominal flexural ductility even for structures not subjected to earthquake attack. Currently, the nominal flexural ductility is provided by imposing empirical deemed-to-satisfy rules, which limit the minimum size and maximum spacing of the confining reinforcement. However, these existing empirical rules have the major shortcoming that the actual level of flexural ductility provided is not consistent, being generally lower at higher concrete strength or higher axial load level. Hence, for high-strength concrete columns subjected to high axial loads, these existing rules are unsafe. Herein, the combined effects of concrete strength, axial load level, confining pressure and longitudinal steel ratio on the flexural ductility are evaluated using nonlinear moment-curvature analysis. Based on the numerical results, a new design method that provides a consistent level of nominal flexural ductility by imposing an upper limit to the axial load level or a lower limit to the confining pressure is developed. Lastly, two formulas and one design chart for direct evaluation of the maximum axial load level and minimum confining pressure are produced.

이동하중과 축하중이 작용하는 유연한 기초위에 지지된 무한보의 동특성 (Dynamic characteristics of flexibly supported infinite beam subjected to an axial force and a moving load)

  • 홍동균;김광식
    • 오토저널
    • /
    • 제4권3호
    • /
    • pp.56-68
    • /
    • 1982
  • This paper presents analytic solutions of defection and their resonance diagrams for a uniform beam of infinite length subjected to an constant axial force and moving transverse load simultaneously. Steady solutions are obtained by a time-independent coordinate moving with the load. The supporting foundation includes damping effects. The influences of the axial force, the damping coefficient and the load velocity on the beam response are studied. The limiting cases of no damping and critical damping are also investigate. The profiles of the deflection of the beam are shown graphically for several values of the load speed, the axial force and damping parameters. Form the results, following conclusions have been reached. 1. The critical velocity .THETA.cr decreases as the axial compressive force increases, but increases as the axial tensile force increase. 2. At the critical velocity .THETA.cr the deflection have a tendency to decrease as the axial tensile force increases and to increase gradually as the axial compressive force increases. 3. In case if relatively small dampings, the deflection increases suddenly as the velocity of the moving load approaches the critical velocity, and it reachs its maximum at the critical velocity, and it decreases and become greatly affected by the axial force as the velocity increases further. 4. in case of relatively large dampings, as the velocity increases the deflection decreases gradually and it is affected little by the axial load.

  • PDF

Long Range and High Axial Load Capacity Nanopositioner Using Single Piezoelectric Actuator and Translating Supports

  • Juluri, Bala Krishna;Lin, Wu;Lim, Lennie E N
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제8권4호
    • /
    • pp.3-9
    • /
    • 2007
  • Existing long range piezoelectric motors with friction based transmission mechanisms are limited by the axial load capacity. To overcome this problem, a new linear piezoelectric motor using one piezoelectric actuator combined with a novel stepping mechanism is reported in this paper. To obtain both long range and fine accuracy, dual positioning control strategy consisting of coarse positioning and fine positioning is used. Coarse positioning is used for long travel range by accumulating motion steps obtained by piezoelectric actuator. This is followed by fine positioning where required accuracy is obtained by fine motion displacement of piezoelectric actuator. This prototype is able to provide resolution of 20 nanometers and withstand a maximum axial load of 300N. At maximum load condition, the positioner can move forward to a travel distance of 5mm at a maximum speed of 0.4 mm/sec. This design of nanopositioner can be used in applications for ultra precision positioning and grinding operations where high axial force capacity is required.

Experimental study on fire performance of axially-restrained NSC and HSC columns

  • Wu, Bo;Li, Yi-Hai
    • Structural Engineering and Mechanics
    • /
    • 제32권5호
    • /
    • pp.635-648
    • /
    • 2009
  • This paper describes fire performance of eight axially restrained reinforced concrete (RC) columns under a combination of two different load ratios and two different axial restraint ratios. The eight RC columns were all concentrically loaded and subjected to ISO834 standard fire on all sides. Axial restraints were imposed at the top of the columns to simulate the restraining effect of the rest of the whole frame. The axial restraint was effective when the column was expanding as well as contracting. As the results of the experiments have shown, the stiffness of the axial restraint and load level play an important role in the fire behaviors of both HSC and NSC columns. It is found that (a) the maximum deformations during expanding phase were influenced mostly by load ratio and hardly by axial restraint ratio, (b) For a given load ratio, axial restraint ratio had a great impact on the development of axial deformation during contraction phase beyond the initial equilibrium state, (c) increasing the axial restraint increased the value of restraint force generated in both the NSC and HSC columns, and (d) the development of column axial force during the contracting and cooling phase followed nearly parallel trend for columns under the same load ratio.

축력과 휨 모멘트를 받는 RC 부재의 CFRP 시트 보강에 따른 성능 평가 (Evaluation of Performance of CFRP Sheet Reinforcement on RC Members Subjected to Axial Load and Flexural Moment)

  • 배찬영;이지형;김상우;김진섭
    • 대한토목학회논문집
    • /
    • 제43권5호
    • /
    • pp.567-576
    • /
    • 2023
  • 일반적으로 RC 보 부재는 휨 부재로서 휨 하중에 대해서만 고려하여 설계된다. 하지만, 실제 건축물에서는 부재 간의 연속성으로 인해 축력과 휨 하중을 동시에 받게 된다. 이로 인해 RC 보 부재의 휨 강도는 증가하지만, 변위는 감소하며, 균열은 주로 보의 중앙부에 집중되게 된다. 따라서 본 연구에서는 축력과 휨 하중을 동시에 받는 RC 보 부재에 탄소섬유시트를 이용한 보강에 따른 휨 성능을 실험적으로 평가하였다. 탄소섬유시트는 부재의 중앙부에 감싸 보강을 하였으며, 축력과 휨 하중을 부재에 가력하였다. 축력의 크기와 탄소섬유시트 보강에 따른 철근콘크리트 부재의 파괴 형태, 휨 강도, 처짐 및 연성을 분석하였다. 그 결과, 축력의 증가에 따라 최대 휨 강도의 상승이 발생하였지만, 연성은 최대 64%까지 감소하였다. 탄소섬유시트 보강을 통해 휨 강도는 최대 27% 증가하였으며, 휨에 의한 보의 최대 처짐은 8% 감소하였으며 연성은 최대 43% 증가하였다.

이축 변동하중하에서의 피로수명 예측기법에 관한 연구 (The Study on Fatigue Life Prediction under Biaxial Variable Load)

  • 오세종;이현우;전제춘
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.666-671
    • /
    • 1993
  • Fatigue life prediction under multi-axial variable load were performed for Aluminium 7075-T651 alloy using SAE Notched specimen & Torque tube shaft component specimen. When variable multiaxial load is applied to material, maximum damaged plane(critical plane) change. To clarify the situation, experiment is performed on two different changing load path. For multiaxial fatigue life prediction, miner rule is expanded to critical plane theory. Shear based parameter and Elliptical parameter give better correlation. This suggests that miner rule can be applicable on multi-axial variable load.

  • PDF

Seismic behavior of composite walls with encased steel truss

  • Wu, Yun-tian;Kang, Dao-yang;Su, Yi-ting;Yang, Yeong-bin
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.449-472
    • /
    • 2016
  • This paper studies the seismic behavior of reinforced concrete (RC) walls with encased cold-formed and thin-walled (CFTW) steel truss, which can be used as an alternative to the conventional RC walls or steel reinforced concrete (SRC) composite walls for high-rise buildings in high seismic regions. Seven one-fourth scaled RC wall specimens with encased CFTW steel truss were designed, manufactured and tested to failure under reversed cyclic lateral load and constant axial load. The test parameters were the axial load ratio, configuration and volumetric steel ratio of encased web brace. The behaviors of the test specimens, including damage formation, failure mode, hysteretic curves, stiffness degradation, ductility and energy dissipation, were examined. Test results indicate that the encased web braces can effectively improve the ductility and energy dissipation capacity of RC walls. The steel angles are more suitable to be used as the web brace than the latticed batten plates in enhancing the ductility and energy dissipation. Higher axial load ratio is beneficial to lateral load capacity, but can result in reduced ductility and energy dissipation capacity. A volumetric ratio about 0.25% of encased web brace is believed cost-effective in ensuring satisfactory seismic performance of RC walls. The axial load ratio should not exceed the maximum level, about 0.20 for the nominal value or about 0.50 for the design value. Numerical analyses were performed to predict the backbone curves of the specimens and calculation formula from the Chinese Code for Design of Composite Structures was used to predict the maximum lateral load capacity. The comparison shows good agreement between the test and predicted results.

철근이 부식된 철근콘크리트 기둥의 구조성능 평가에 대한 실험적 연구 (An Experimental Study on Evaluation of Structural Performance on Corroded Reinforced Concrete Columns)

  • 원종호;한남희;정란
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.711-717
    • /
    • 2000
  • This paper presents an experimental study on evaluation of structural performance on corroded reinforced concrete columns under only axial load, combined axial load and lateral load. This test was carried on the twenty-six reinforced concrete columns with $150\times150\times800$mm size subjected to combined axial load and lateral load. Effects of key variables such as the corrosion level, the number of hoop, the corrosion of hoop are studied in this program. The results of this study show that the capacity of column axial force was decreased as corrosion level was increased, especially, rapid development was shown after 10% corrosion level and the maximum moment capacity of column was shown at corrosion level 1.2%, while rapid decrease was shown after 4.3% corrosion level. Also we found that influence of corrosion was decreased to number of tie bar was increased.

  • PDF

벽식 구조체 적용을 위한 구조용단열패널 성능 평가 (Evaluation on Structural Performance of Structural Insulated Panels in Wall Application)

  • 나환선;이현주;이철희;황성욱;조혜진;최성모
    • 복합신소재구조학회 논문집
    • /
    • 제3권2호
    • /
    • pp.19-27
    • /
    • 2012
  • Structural insulated panels, which are structurally performed panels consisting of a plastic insulation bonded between two structural panel facings are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. By now, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to suggest fundamental reports such as racking resistance, axial capacity, transverse load capacity, and lintel load capacity for SIPs. Test results showed that maximum load was 44.3kN, allowable load was 14.7kN for racking resistance, and that maximum load was 137.6kN, allowable load was 37.4kN/m for axial compression capacity. For transverse load capacity, test results showed $10.3kN/m^2$ of maximum load, $3.4kN/m^2$ of allowable load. For lintel load capacity for SIPs dependent to lengths, allowable loads were 20.4kN for 600mm long lintel, 23.9kN for 1,200mm long lintel, 19.3kN for 1,800mm long lintel, and 2,400mm long lintel had 14.1kN of allowable load. In the near future, when the allowable load for wall application is established, SIPs is considered to substitute the existent post-and-lintel construction to bearing wall structure.