• Title/Summary/Keyword: Maximum Electric Field

Search Result 322, Processing Time 0.031 seconds

Development of a Remote Controlled Weeder Driven by Solar Battery Power (태양전지를 이용한 원격조종 중경제초기 개발)

  • Kim, T.S.;Jang, I.J.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.2 s.121
    • /
    • pp.91-96
    • /
    • 2007
  • In this study, a prototype remote controlled weeder using solar module was developed and the evaluations of weeding, side walking and weeding performance were conducted to see if actual application was feasible in the paddy field. When traveling, the loss electric current was 8 to 15 A depending on operating and soil conditions. The average traveling speed was 0.25 m/s and the average slippage was 18%. When it side walked row by row, electric current consumption was 7 A on the average. When wheel rotors line went initially up and last down, electric current consumption was 12 to 15 A due to soil resistance. Electric current consumption when shifting wheel rotors line was less than 5 A due to no resistance. Field efficiency was 105 min/10a based on the test field. Operation was able to be done for 4.16 hours continually by 52 AH battery based on 300 W average maximum power consumption and 4.6 hours under sunny day considering solar module.

Analysis of Partial Discharge Inception Voltages for the Wrong Positioning Defects in the Joint of Distribution Power Cables

  • Kim, Jeong-Tae;Kim, Dong-Uk;Lee, Young-Jo;Koo, Ja-Yoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.977-982
    • /
    • 2012
  • In order to find out partial discharge (PD) phenomena in the cable joint due to the poor workmanship during the installation, the relationship between PD inception voltages and joint defects was investigated. For the purpose, in the joint of 22.9kV CNCV cables, electric fields were calculated for various semiconductive layer wrong positioning (WP) defects. And, PDIV were investigated through the experiments and compared with the results of electric field analysis. In all WP defect cases, the PD inception field calculated using measured PDIVs was similarly shown to be the average value of 1.84kV/mm. In addition, the calculated PDIV and the measured PDIV were almost equal, from the PDIV calculation using maximum electric fields and the measured PDIV for the normal case. Throughout this study, it is possible to analyze WP defects due to the poor workmanship and to establish better joint design for the distribution grade extruded cable system.

Measurements of Electric and Magnetic Fields in the Vicinity of Transmission Lines and Electric Appliances (송전선로 부근과 가전제품의 전자계 측정)

  • 김상범;조성배;이동일;신구용;김정부
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.687-697
    • /
    • 1998
  • In spite of increasing public concern about the human exposure to electric and magnetic fields(EMFs), there is little information about the EMF levels in the vicinity of power facilities and of home appliances. To provide such information, a nationwide survey for EMFs near overhead transmission lines has been conducted. The median values of the electric fields and magnetic fields of 153 transmission lines were 0.47 kV/m and 11.6 mG, respectively. The maximum values were 3.16 kV/m and 125 mG. These were low values in comparison with any EMF guidelines or standards of advanced contries. Measurements of the magnetic fields of typical home appliances and daily human exposure records have been also conducted. These magnetic field values were comparable to those of the transmission lines.

  • PDF

Transformation of Bacillus brevis P176-2 with Plasmid DNA by Electroporation (전기천공법에 의한 Bacillus brevis P176-2의 형질전환)

  • 채기수;엄경일
    • The Korean Journal of Food And Nutrition
    • /
    • v.5 no.2
    • /
    • pp.77-83
    • /
    • 1992
  • The optimum conditions and mechanisms for the plasmid-mediated genetic transformation of intact cells of Bacillus brevis Pl76-2, an extracellular protein producing bacterium by electroporation were investigated. It was found that pUB110 Plasmid DNA can be introduced into intact bacterial cells by electroporation. The frequency of transformation by this electroporation system depended upon the initial electric field strength, the capacity of the electric discharge capacitor, growth stage, number of successive pulses and composition of electroporation buffer. It was effective for transformation that cells were harvested, washed and resuspended with HSM [7M HEPES(PH 7.4), 272mM sucrose, 1 mM MgCl2] electroporation buffer when cell growth was attained to 1.2 at OD660. A maximum frequency of transformation of 2.40$\times$104 transformants per$\mu$g plasmid DNA was obtained by two succesive Pulses with an initial electric field strength of 12.5kV/cm and with a capacitance of 7.3uF.

  • PDF

Dielectric Recovery Characteristics between Poles of 800kV Model Interrupter -I. Effects or separation between Moving Main Contact and Moving Arcing Contact- (800kV 모델차단부의 극간 절연회복특성 -I. 가동주접점과 가동아크접점간 이격거리의 변화에 대한 영향분석-)

  • Shin, Y.J.;Park, K.Y.;Chang, K.C.;Song, K.D.;Jeong, J.K.;Song, W.P.;Kang, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.270-273
    • /
    • 1994
  • The capacitive current breaking capability as well as the short circuit current breaking capability is a very important factor in the performance of a circuit breaker. The dielectric recovery capability between poles should be considered in the desist of a circuit breaker because approximately two times of the maximum power system voltage might be applied between poles after the capacitive current be interrupted. The electric field and flow field analyses were utilized in the calculation of dielectric recovery characteristics between poles of 800kV model interrupter. The results show that the separation between moving main contact and moving arcing contact will affect to decrease significantly the electric field strength of a moving arcing contact and an insulation cover, to increase slightly the electric field strength of a fixed arcing contact and to decrease consequently the dielectric recovery capability between poles of the interrupter.

  • PDF

Electroporation and Viability Monitoring Chip for Lung Cancer Cells in Single Channel with Multiple Electric Field Zones (다수의 전기장 분포가 생성되는 단일 미세유로를 이용한 폐암세포 전기천공 및 활성도 분석칩)

  • Kim, Min-Ji;Kim, Tae-Yoon;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.901-905
    • /
    • 2012
  • We present an electroporation and viability monitoring chip for lung cancer cells in a single channel with multiple electric field zones. Previous electroporation chips utilized multiple microchannels or electrodes to form multiple electric fields, thus resulting in complex structures. However, the present chip can generate multiple electric fields in a single stepwise microchannel between a pair of electrodes, thus achieving the analysis of both cell electroporation and viability with a simple structure. We demonstrate that the electric field of 0.4 kV/cm results in a maximum percentage of $51.4{\pm}3.0%$ and $26.6{\pm}0.7%$ of viable and electroporated human lung cancer cells, H23 and A549, respectively. The present chip has potential for use in integrated cell chips for transfection studies.

Experimental study on the lightning impulse breakdown characteristics of air for the development of air-insulated high voltage apparatuses (고전압 전력기기 개발을 위한 기중 임펄스절연파괴특성에 관한 연구)

  • Kang, Hyoun-Gku;Kim, Joon-Yeon;Seok, Bok-Yeol;Kim, Dong-Hae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1473_1474
    • /
    • 2009
  • To develop electrically reliable high voltage apparatuses, the experimental study on the electrical breakdown field strength is needed, as well as theoretical approach. In this paper, lightning impulse breakdown characteristics considering utilization factors are investigated for the establishment of insulation design criteria of an high voltage apparatus. The utilization factors are represented as the ratio of mean electric field to maximum electric field. Dielectric experiments are performed by using five kinds of sphere-plane electrode systems made of stainless steel. As a result, it is found that dielectric characteristics are affected by not only gap length but also utilization factor of electrode systems. The results are expected to be applicable to the design of high voltage apparatuses.

  • PDF

Characteristics calculation on radio frequency power transfer in a planar inductively coupled plasma source (평면형 유도결합 플라즈마 장치에서의 RF 전력 전달 특성 계산)

  • 이정순;정태훈
    • Journal of the Korean Vacuum Society
    • /
    • v.8 no.3B
    • /
    • pp.368-375
    • /
    • 1999
  • The Maxwell equation and the transformer equivalent-circuit model are applied to a radio frequency planar inductively coupled plasma. The spatial distribution of the vector potential, the magnetic field, and the electric field are obtained analytically. As a result, the plasma current, the mutual inductance between the coil and the plasma, and the self inductance of plasma are found to increase with increasing skin depth. The spatial distribution of absorbed power has maximum where the antenna coil exists, and has a similar profile to that of the induced electric field. The power transfer efficiency is found to increase with increasing gas pressure before a saturation around p+ 20mTorr, while it shows an increase with the plasma density before a slight decrease around a density of $5\times10^{11}/\textrm{cm}^3$.

  • PDF

Penetrated Electric Fields and Resonant Frequencies inside Metallic Enclosure with Aperture Exited by an External Dipole Source (개구를 갖는 함체의 외부 다이폴 파원에 의한 침투전계와 공진 주파수 특성)

  • 황보승;김기채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.939-947
    • /
    • 2001
  • This paper presents the penetrated electric fields and resonant frequencies inside a metallic enclosure with aperture excited by an external dipole source. In the theoretical analysis, integral equations for the current distribution and electric field distributions on the aperture are solved by applying Galerkin\`s method of moments. The results show that the electric fields inside metallic enclosure is maximum at the near the aperture and resonant frequencies are the same as calculated of the enclosure without aperture. To verify the theoretical analysis the electric field inside enclosure and resonant frequencies are compared with the experimental results.

  • PDF

Design and test result of a superconducting double-spoke cavity

  • Jiang, Tiancai;Huang, Yulu;Zhang, Shengxue;Liu, Lubei;Xiong, Pingran;Li, Chunlong;Guo, Hao;Yue, Weiming;Zhang, Shenghu;He, Yuan
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.877-883
    • /
    • 2019
  • Superconducting multi-spoke cavities are outstanding alternative choice for acceleration of heavy ions in medium velocity regimes. Based on the scheme of China ADS, several researches on the superconducting double-spoke cavities were done and two prototype cavities have been developed. In this paper, the RF design, the mechanical design and fabrication considerations of the bare cavity will be described in detail. After Buffered Chemical Polishing and High Pressure Rinsing, one of the prototype cavities was installed into the Vertical Test Stand for high gradient RF testing at 4.2 K. The measurement results of the quality factor as a function of the accelerating field and the maximum surface field will be presented. An accelerating gradient of more than 15 MV/m is achieved during the test, with maximum surface electric field of 58 MV/m, and maximum surface magnetic field of 117 mT.