• 제목/요약/키워드: Material Measurements

검색결과 1,586건 처리시간 0.027초

140 keV 감마선 차폐 시 납 차폐체 두께에 따른 깊이별 선량 평가 (Shielding 140 keV Gamma Ray Evaluation of Dose by Depth According to Thickness of Lead Shield)

  • 김지영;이왕희;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.129-134
    • /
    • 2018
  • The present study made a phantom for gamma ray of 140 keV radiated from $^{99m}Tc$, examined shielding effect of lead by thickness of the shielding material, and measured surface dose and depth dose by body depth. The OSL Nano Dot dosimeter was inserted at 0, 3, 15, 40, 90, and 180 mm depths of the phantom, and when there was no shield, 0.2 mm lead shield, 0.5 mm lead shield, The depth dose was measured. Experimental results show that the total cumulative dose of dosimeters with depth is highest at 366.24 uSv without shield and lowest at 94.12 uSv with 0.5 mm lead shield. The shielding effect of 0.2 mm lead shielding was about 30.18% and the shielding effect of 0.5 mm lead shielding was 74.30%, when the total sum of the accumulated doses of radiation dosimeter was 100%. The phantom depth and depth dose measurements showed the highest values at 0 mm depth for all three experiments and the dose decreases as the depth increases. This study proved that the thicker a shielding material, the highest its shielding effect is against gamma ray of 140 keV. However, it was known that shielding material can't completely shield a body from gamma ray; it reached deep part of a human body. Aside from the International Commission on Radiation Units and Measurements (ICRU) recommending depth dose by 10 mm in thickness, a plan is necessary for employees working in department of nuclear medicine where they deal with gamma ray, which is highly penetrable, to measure depth dose by body depth, which can help them manage exposed dose properly.

희생양극을 이용한 태양광 리본의 부식 저감 (Corrosion mitigation of photovoltaic ribbon using a sacrificial anode)

  • 오원욱;천성일
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.681-686
    • /
    • 2017
  • 태양광 모듈에서 태양전지를 연결해주는 인터커넥터로 리본 솔더로 SnPbAg가 사용되고, 옥외 태양광 발전에 장기간 노출시 리본의 부식으로 인한 열화가 흔히 관찰된다. 이러한 부식현상으로 인하여 리본과 태양전지의 접합이 약해져 접촉저항이 증가하고, 또한 리본 자체의 직렬 저항이 증가하게 되어 태양전지의 전압 전류 곡선에서 충진률 손실로 출력이 저하된다. 본 논문에서는 리본의 부식을 완화시킬 수 있는 방법으로 희생양극법을 이용하여 순수 알루미늄 및 아연, 알루미늄, 아연 그리고 마그네슘의 합금을 이용한 5가지 희생양극 소재의 부식에 의한 열화 저감을 연구하였다. 전기화학적 방법으로 희생양극 소재의 개방회로 전위와 폐쇄회로 전위를 측정하였고, 포텐시오다이나믹 분극 곡선을 측정하고, 영저항전류계를 이용하여 리본과 소재간의 갈바닉 전류를 측정하였다. 또한, 아세트산과, NaCl에 리본과 희생양극 소재의 부착 전후의 침지시험과 4셀 미니모듈로 제작한 후 1500시간 고온고습 시험 전후 출력을 평가하였다. 그 결과 Al-3Mg와 Al-3Zn-1Mg의 희생양극 소재가 부식속도가 느리고, 출력저하를 저감시킬 뿐만 아니라 장기 안정성에도 효과적인 것으로 평가된다.

Dislocations as native nanostructures - electronic properties

  • Reiche, Manfred;Kittler, Martin;Uebensee, Hartmut;Pippel, Eckhard;Hopfe, Sigrid
    • Advances in nano research
    • /
    • 제2권1호
    • /
    • pp.1-14
    • /
    • 2014
  • Dislocations are basic crystal defects and represent one-dimensional native nanostructures embedded in a perfect crystalline matrix. Their structure is predefined by crystal symmetry. Two-dimensional, self-organized arrays of such nanostructures are realized reproducibly using specific preparation conditions (semiconductor wafer direct bonding). This technique allows separating dislocations up to a few hundred nanometers which enables electrical measurements of only a few, or, in the ideal case, of an individual dislocation. Electrical properties of dislocations in silicon were measured using MOSFETs as test structures. It is shown that an increase of the drain current results for nMOSFETs which is caused by a high concentration of electrons on dislocations in p-type material. The number of electrons on a dislocation is estimated from device simulations. This leads to the conclusion that metallic-like conduction exists along dislocations in this material caused by a one-dimensional carrier confinement. On the other hand, measurements of pMOSFETs prepared in n-type silicon proved the dominant transport of holes along dislocations. The experimentally measured increase of the drain current, however, is here not only caused by an higher hole concentration on these defects but also by an increasing hole mobility along dislocations. All the data proved for the first time the ambipolar behavior of dislocations in silicon. Dislocations in p-type Si form efficient one-dimensional channels for electrons, while dislocations in n-type material cause one-dimensional channels for holes.

폴리우레탄폼의 흡음율에 대한 첨가제의 영향 (The Effect of Additives on Sound Absorption Coefficient of Polyurethane Foam)

  • 박남국;김영철;박종래
    • 공업화학
    • /
    • 제8권2호
    • /
    • pp.197-203
    • /
    • 1997
  • 본 연구에서는 폴리우레탄폼 제조시 사용되는 첨가제가 폴리우레탄폼의 기계적 물성에 미치는 영향에 대하여 조사하였다. 실험에 사용된 수지는 KONIX FA-703 폴리에테르폴리올(80%)과, KONIX FA-733 폴리에테르폴리올(20%)에 촉매, 계면활성제, 가교제 등을 혼합하여 제조하였으며, 이 수지에 이소시아네이트(TDI-80, prepolymer M-200, pure MDI)를 당량비로 첨가하여 발포시킨 폼을 상온에서 72시간 경화시킨 후 물성측정에 사용하였다. 폴리우레탄폼의 기계적 물성은 밀도, 인장강도, 인열강도, 신장율, 흡음율 및 gel profile을 조사함으로써 측정하였고, 셀 크기에 대한 계면활성제의 영향은 주사전자현미경(SEM)을 사용하여 측정하였다. 흡음율은 셀의 크기와 직접적인 관련이 있었으며, 계면활성제(L-5309)의 사용량에 따른 인장강도, 인열강도 및 흡음율 등 기계적 물성은 1.0pphp 까지는 첨가량이 많아질수록 증가하는 경향을 보이다가 점차 감소하였다.

  • PDF

Antiaging effects of the mixture of Panax ginseng and Crataegus pinnatifida in human dermal fibroblasts and healthy human skin

  • Hwang, Eunson;Park, Sang-Yong;Yin, Chang Shik;Kim, Hee-Taek;Kim, Yong Min;Yi, Tae Hoo
    • Journal of Ginseng Research
    • /
    • 제41권1호
    • /
    • pp.69-77
    • /
    • 2017
  • Background: Human skin undergoes distinct changes throughout the aging process, based on both intrinsic and extrinsic factors. In a process called photoaging, UVB irradiation leads to upregulation of matrix metalloproteinase-1, which then causes collagen degradation and premature aging. Mixtures of medicinal plants have traditionally been used as drugs in oriental medicine. Based on the previously reported antioxidant properties of Panax ginseng Meyer and Crataegus pinnatifida, we hypothesized that the mixture of P. ginseng Meyer and C. pinnatifida (GC) would have protective effects against skin aging. Methods: Anti-aging activity was examined both in human dermal fibroblasts under UVB irradiation by using Western blot analysis and in healthy human skin by examining noninvasive measurements. Results: In vitro studies showed that GC improved procollagen type I expression and diminished matrix metalloproteinase-1 secretion. Based on noninvasive measurements, skin roughness values, including total roughness (R1), maximum roughness (R2), smoothness depth and average roughness (R3), and global photodamage scores were improved by GC application. Moreover, GC ameliorated the high values of smoothness depth (R4), which means that GC reduced loss of skin moisture. Conclusion: These results suggest that GC can prevent aging by inhibiting wrinkle formation and increasing moisture in the human skin.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Current status of disposal and measurement analysis of radioactive components in linear accelerators in Korea

  • Kwon, Na Hye;Shin, Dong Oh;Kim, Jinsung;Yoo, Jaeryong;Park, Min Seok;Kim, Kum Bae;Kim, Dong Wook;Choi, Sang Hyoun
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.507-513
    • /
    • 2022
  • When X-ray energy above 8 MV is used, photoneutrons are generated by the photonuclear reaction, which activates the components of linear accelerator (linac). Safely managing the radioactive material, when disposing linac or replacing components, is difficult, as the standards for the radioactive material management are not clear in Korea. We surveyed the management status of radioactive components occurred from medical linacs in Korea. And we also measured the activation of each part of the discarded Elekta linac using a survey meter and portable High Purity Germanium (HPGe) detector. We found that most medical institutions did not perform radiation measurements when disposing of radioactive components. The radioactive material was either stored within the institution or collected by the manufacturer. The surface dose rate measurements showed that the parts with high surface dose rates were target, primary collimator, and multileaf collimator (MLC). 60Co nuclide was detected in most parts, whereas for the target, 60Co and 184Re nuclides were detected. Results suggest that most institutions in Korea did not have the regulations for disposing radioactive waste from linac or the management procedures and standards were unclear. Further studies are underway to evaluate short-lived radionuclides and to lay the foundation for radioactive waste management from medical linacs.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

Characterization of Stiffness Coefficients of Silicon Versus Temperature using "Poisson's Rati" Measurements

  • Cho, Chun-Hyung;Cha, Ho-Young;Sung, Hyuk-Kee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권2호
    • /
    • pp.153-158
    • /
    • 2016
  • The elastic material constants, stiffness constants ($c_{11}$, $c_{12}$, and $c_{44}$), are three unique coefficients that establish the relation between stress and strain. Accurate knowledge of mechanical properties and the stiffness coefficients for silicon is required for design of Micro-Electro-Mechanical Systems (MEMS) devices for proper modeling of stress and strain in electronic packaging. In this work, the stiffness coefficients for silicon as a function of temperature from $-150^{\circ}C$ to $+25^{\circ}C$ have been extracted by using the experimental measurements of Poisson's ratio (${\nu}$) of silicon in several directions.

A Study of the Change of Hall Effect as a Function of the V/III Ratio in n-GaAs compound Semiconductors

  • Kim, In-Sung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권4호
    • /
    • pp.107-110
    • /
    • 2009
  • In this study, the Hall effect has been studied in n-GaAs samples characterized by V/IIl growth ratios of 25, 50 and 100 and prepared by metal organic chemical vapor deposition. For the Hall effect measurements, the grown samples were cut to a size of 1${\times}$1 cm. The measurements were carried out at room temperature, using Indium contact metal at the four corners of the samples. According to the experimental results, the Schottky effect was not ovservation. Also for the n-GaAs sample of V/Ill 100 ratio the electron drift velocity was very high.