• Title/Summary/Keyword: Matching Ratio

Search Result 495, Processing Time 0.024 seconds

A Fast and Accurate Face Detection and Tracking Method by using Depth Information and color information (깊이정보와 컬러정보를 이용한 고속 고정밀 얼굴검출 및 추적 방법)

  • Kim, Woo-Youl;Seo, Young-Ho;Kim, Dong-Wook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1825-1838
    • /
    • 2012
  • This paper proposes a fast face detection and tracking method which uses depth images as well as RGB images. It consists of the face detection procedure and the face tracking procedure. The face detection method basically uses an existing method, Adaboost, but it reduces the size of the search area by using the depth information and skin color. The proposed face tracking method uses a template matching technique and incorporates an early-termination scheme to reduce the execution time further. The results from implementing and experimenting the proposed methods showed that the proposed face detection method takes only about 39% of the execution time of the existing method. The proposed tracking method takes only 2.48ms per frame. For the exactness, the proposed detection method and previous method showed a same detection ratio but in the error ratio, which is about 0.66%, the proposed method showed considerably improved performance. In all the cases except a special one, the tracking error ratio is as low as about 1%. Therefore, we expect the proposed face detection and tracking methods can be used individually or in combined for many applications that need fast execution and exact detection or tracking.

The variable power divider circuit to use the ring-hybrid coupler (링-하이브리드 커플러를 이용한 가변 전력 분배기 회로)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.253-259
    • /
    • 2016
  • This paper introduces a new variable power divider circuit with an arbitrary power division ratio ranging from $1:{\infty}$ to ${\infty}:1$. The proposed power divider circuit consists of one branch-line coupler to be a good input matching characteristic, two variable phase shifters with 90-degree phase variation to be connected two output paths of the branch-line coupler, and one ring-hybrid coupler to combine output signals of two variable phase shifter. The power division ratio between the two output ports of the proposed power divider can be easily controlled by the phase variation of the two phase shifter. The proposed power divider circuit fabricates on laminated RF-35 (h = 20 mil, er=3.5; Taconic) with a center frequency of 2 GHz. The power division ratio of the fabricated prototype varies from about 1:1000 to 5000000:1, with an input reflection characteristic(S11) of below -20 dB, an insertion loss of about -1.0 dB, and an isolation characteristic of below -17 dB between two output ports in the range 1.9-2.1 GHz.

Effect of night shift work on the reduction of glomerular filtration rate using data from Korea Medical Institute (2016-2020)

  • Beom Seok Ko;Sang Yop Shin;Ji Eun Hong;Sungbeom Kim;Jihhyeon Yi;Jeongbae Rhie
    • Annals of Occupational and Environmental Medicine
    • /
    • v.35
    • /
    • pp.22.1-22.9
    • /
    • 2023
  • Background: Shift work increases the risk of chronic diseases, including metabolic diseases. However, studies on the relationship between shift work and renal function are limited. The aim of this study was to investigate the association between shift work and a decreased glomerular filtration rate (GFR). Methods: Data were evaluated for 1,324,930 workers who visited the Korean Medical Institute from January 1, 2016 to December 31, 2020 and underwent a health checkup. Daytime workers were randomly extracted at a ratio of 1:4 after matching for age and sex. In total, 18,190 workers aged over 40 years were included in the analyses; these included 3,638 shift workers and 14,552 daytime workers. Participants were categorized into the shift work group when they underwent a specific health checkup for night shift work or indicated that they were shift workers in the questionnaire. The odds ratio was calculated using a conditional logistic regression to investigate the relevance of shift work for changes in GFR. Results: 35 workers in the shift group and 54 in the daytime group exhibited an estimated GFR (eGFR) value of < 60 mL/min/1.73m2 (p < 0.01). The difference in eGFR values between two checkups differed significantly depending on the type of work (p < 0.01); the difference in the shift work group (-9.64 mL/min/1.73 m2) was larger than that in the daytime work group (-7.45 mL/min/1.73 m2). The odds ratio for eGFR reduction to < 60 mL/min/1.73 m2 in the shift group versus the daytime group was 4.07 (95% confidence interval: 2.54-6.52), which was statistically significant. Conclusions: The results of this study suggest that eGFR decreases by a significantly larger value in shift workers than in daytime workers; thus, shift work could be a contributing factor for chronic kidney disease (CKD). Further prospective studies are necessary to validate this finding and identify measures to prevent CKD in shift workers.

A Neurobehavioral Performance Assessment in Lacunar Infarction Case-control Study (열공성 뇌경색 환자-대조군에서 신경행동검사의 수행 평가)

  • Kim, Ham-Gyum;Park, Sue-Kyung;Lee, Kun-Sei;Kim, Hyeoug-Su;Kim, Wha-Sun;Chang, Soung-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.36 no.3
    • /
    • pp.255-262
    • /
    • 2003
  • Objectives : We carried out tests for neurobehavior by using WHO-NCTB (neurobehavioral core test battery) and Perdue pegboard score test to identify differences between lacunar infarction cases and controls. Methods : Among the subjects who underwent MRI between February 2001 and March 2002 in a university hospital located in Seoul and who were diagnosed only as lacunar infarction without any intracranial disease, 46 patients were selected as cases (male: 21, female: 25). Controls were selected who had no cerebrovascular disease on MRI by matching age (5 years), gender, and education (2 years) in a ratio of 1:1 , Among WHO-NCTB, the following 5 tests and Perdue pegboard score test were used to categorize the study subjects: digit and symbol matching, simple reaction time, Benton visual retention, digit span, and Pursuit aiming test, Results : Among the above 6 tests of neurobehavior, lacunar infarction cases showed lower score than controls except for the simple reaction time test. As the controlling variables of multivariate analysis in the stepwise regression analysis, the followings were selected due to their significant association: age, education, BMI, gender, drinking, exercise, add systolic blood pressure. From multivariate regression analysis, there was significant difference (p<0.05) between lacunar infarction cases and controls in digit and symbol matching, Benton visual retention, digit span, pursuit aiming, and Perdue pegboard score test, but not in the score of simple reaction time test. Conclusions : We suggest that the above 5 tests for neurobehavior, with the exception of the simple reaction time test, might be used as the basis for recommendation of further treatment and other neurological tests by the earlier defection for neurological abnormality in lacunar infarction.

Markov chain-based mass estimation method for loose part monitoring system and its performance

  • Shin, Sung-Hwan;Park, Jin-Ho;Yoon, Doo-Byung;Han, Soon-Woo;Kang, To
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1555-1562
    • /
    • 2017
  • A loose part monitoring system is used to identify unexpected loose parts in a nuclear reactor vessel or steam generator. It is still necessary for the mass estimation of loose parts, one function of a loose part monitoring system, to develop a new method due to the high estimation error of conventional methods such as Hertz's impact theory and the frequency ratio method. The purpose of this study is to propose a mass estimation method using a Markov decision process and compare its performance with a method using an artificial neural network model proposed in a previous study. First, how to extract feature vectors using discrete cosine transform was explained. Second, Markov chains were designed with codebooks obtained from the feature vector. A 1/8-scaled mockup of the reactor vessel for OPR1000 was employed, and all used signals were obtained by impacting its surface with several solid spherical masses. Next, the performance of mass estimation by the proposed Markov model was compared with that of the artificial neural network model. Finally, it was investigated that the proposed Markov model had matching error below 20% in mass estimation. That was a similar performance to the method using an artificial neural network model and considerably improved in comparison with the conventional methods.

Costoclavicular brachial plexus block reduces hemidiaphragmatic paralysis more than supraclavicular brachial plexus block: retrospective, propensity score matched cohort study

  • Oh, Chahyun;Noh, Chan;Eom, Hongsik;Lee, Sangmin;Park, Seyeon;Lee, Sunyeul;Shin, Yong Sup;Ko, Youngkwon;Chung, Woosuk;Hong, Boohwi
    • The Korean Journal of Pain
    • /
    • v.33 no.2
    • /
    • pp.144-152
    • /
    • 2020
  • Background: Hemidiaphragmatic paralysis, a frequent complication of the brachial plexus block performed above the clavicle, is rarely associated with an infraclavicular approach. The costoclavicular brachial plexus block is emerging as a promising infraclavicular approach. However, it may increase the risk of hemidiaphragmatic paralysis because the proximity to the phrenic nerve is greater than in the classical infraclavicular approach. Methods: This retrospective analysis compared the incidence of hemidiaphragmatic paralysis in patients undergoing costoclavicular and supraclavicular brachial plexus blocks. Of 315 patients who underwent brachial plexus block performed by a single anesthesiologist, 118 underwent costoclavicular, and 197 underwent supraclavicular brachial plexus block. Propensity score matching selected 118 pairs of patients. The primary outcome was the incidence of hemidiaphragmatic paralysis, defined as a postoperative elevation of the hemidiaphragm > 20 mm. Factors affecting the incidence of hemidiaphragmatic paralysis were also evaluated. Results: Hemidiaphragmatic paralysis was observed in three patients (2.5%) who underwent costoclavicular and 47 (39.8%) who underwent supraclavicular brachial plexus blocks (P < 0.001; odds ratio, 0.04; 95% confidence interval, 0.01-0.13). Both the brachial plexus block approach and the injected volume of local anesthetic were significantly associated with hemidiaphragmatic paralysis. Conclusions: The incidence of hemidiaphragmatic paralysis is significantly lower with costoclavicular than with supraclavicular brachial plexus block.

Video Signature using Spatio-Temporal Information for Video Copy Detection (동영상 복사본 검출을 위한 시공간 정보를 이용한 동영상 서명 - 동심원 구획 기반 서술자를 이용한 동영상 복사본 검출 기술)

  • Cho, Ik-Hwan;Oh, Weon-Geun;Jeong, Dong-Seok
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.607-611
    • /
    • 2008
  • This paper proposes new video signature using spatio-temporal information for copy detection. The proposed video copy detection method is based on concentric circle partitioning method for each key frame. Firstly, key frames are extracted from whole video using temporal bilinear interpolation periodically and each frame is partitioned as a shape of concentric circle. For the partitioned sub-regions, 4 feature distributions of average intensity, its difference, symmetric difference and circular difference distributions are obtained by using the relation between the sub-regions. Finally these feature distributions are converted into binary signature by using simple hash function and merged together. For the proposed video signature, the similarity distance is calculated by simple Hamming distance so that its matching speed is very fast. From experiment results, the proposed method shows high detection success ratio of average 97.4% for various modifications. Therefore it is expected that the proposed method can be utilized for video copy detection widely.

  • PDF

Design and Fabrication of Wideband Probe for Efficient Near Field Measurement (근역장의 효율적 측정을 위한 광대역 프로브의 설계 및 제작)

  • Kim Joung-Myoun;Moon Jung-Ick;Yun Je-Hoon;Jeon Soon-Ik;Kim Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.9 s.112
    • /
    • pp.836-844
    • /
    • 2006
  • In this paper, we designed and fabricated the wideband probe with double ridged waveguide for Near-field Measurement. An exponential taper ridge in the rectangular waveguide was implemented for wideband impedance matching. It has wideband characteristics and its measured impedance bandwidth ratio is approximately 2.2:1 from 8.2 GHz to 18 GHz for $VSWR\leq2.2$. It maintains about the same radiation pattern over the entire bandwidth and has more than 4.5 dBi peak radiation gain. Our designed probe was applied to near-field measurement. A good agreement has been found between simulated and measured results.

A Design of Ultra Wide-Band Feedforward Amplifier Using Equal Group-Delayed Signal Canceller (동일 군속도 지연 신호 상쇄기를 이용한 광대역 Feedforward증폭기 설계)

  • Jeong Yong-Chae;Ahn Dal;Kim Hong-Gi;Kim Chul-Dong;Chang Ik-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.8 s.99
    • /
    • pp.825-834
    • /
    • 2005
  • In this paper, a new signal canceller that input signals are equally group-delayed and cancelled each other is proposed and feedforward linearizing power amplifier that adopt the proposed signal cancellers is fabricated. Although the conventional signal canceller can't matches the phase and the group delay time of input signals simultaneously, the proposed signal canceller matches those simultaneously. Simultaneous matching of the phase and the group delay time can makes wideband signal cancellation. The main signal cancellation loop of the fabricated feedforward amplifier with the proposed signal cancellers cancel input signal more than 26.3 dB and the intermodulation distortion signal cancellation loop cancel more than 15.2 dB for 200 MHz bandwidth. And the proposed feedforward power amplifier improves C/I ratio by 20.8 dB with two tones at 2,115 MHz, 2,165 MHz, respectively.

A Study on Design and Fabricate of a Intermediate Frequency Band SAW Filter (IF 대역 SAW 필터 설계 및 제작)

  • 유일현;권희두;정양희
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.10-15
    • /
    • 1999
  • We have studied a method to design and fabricate the Intermediate Frequency(IF) band pass filter with low shape factor which is used for CDMA base station on the 35°Y-cut X-propagation Quartz substrate. In order to fabricate a device of the low shape factor for the IF SAW filter on this substrate, we employed apodization weighted type interdigital transducer(IDT) as an input and withdrawal weighted type IDT as an output by using impulse modelling method. Also, using the Kaiser-Bessel window function, we have adopted 2200pairs and 1000pairs of input and oueut IDT respectively to minimize the effect of ripple. Furthermore, the width and the space of IDT finger are 3.6 ㎛ and 3.5 ㎛ respectively. Thus, we can have optimal results when the IDT thickness is 6000Å in consideration of the ratio of SAW's wavelength while it's aperture is 2mm for impedance matching. The fabricated SAW filter for CDMA had the property of almost 115.2MHz of a center frequency, less then 1.27MHz of bandwidth, less than 1.3 of shape factor, - l5dB of out band attenuation insertion loss and -45dB of rejection band.

  • PDF