• 제목/요약/키워드: Mass wall

검색결과 1,141건 처리시간 0.029초

흉벽의 간엽세포종(과오종)수술치험 1예 보고 (Chest Wall Hamartoma in Infancy A case report)

  • 조현민;김해균;문동석
    • Journal of Chest Surgery
    • /
    • 제29권10호
    • /
    • pp.1170-1172
    • /
    • 1996
  • 흉벽의 간엽세포종(과오종)은 아주 드문 질환이다. 생후 4개월된 여아로 흉벽에 종괴가 발견되었는데, 반복되는 상기도 감염을 주소로 내원하였다. 단순흉부촬영상 늑골침범과 함께 늑간이 넓어진 소견을 보였다. 흉부전삯화단층될영상 경계가 분명한 고형성 및 낭종성 흉막외 종괴가 관찰되었고 흉부책자 기공명 촬영상 고신호강도와 저 신호강도를 보이는 종괴가 보였다. 환아는 1995년 12월에 종괴를 포함하여 늑골의 일부까지 절제하였으며 thick Gortexpatch를 이용하여 흉벽재건술을 시행받았다. 병리조직학적으로 흉벽간엽세포종(과오종)으로 진단받았으며 수술후 경과는 좋았다.

  • PDF

Proteomic profiles and ultrastructure of regenerating protoplast of Bryopsis plumosa (Chlorophyta)

  • Klochkova, Tatyana A.;Kwak, Min Seok;Kim, Gwang Hoon
    • ALGAE
    • /
    • 제31권4호
    • /
    • pp.379-390
    • /
    • 2016
  • When a multinucleate cell of Bryopsis plumosa was collapsed by a physical wounding, the extruded protoplasm aggregated into numerous protoplasmic masses in sea water. A polysaccharide envelope which initially covered the protoplasmic mass was peeled off when a cell membrane developed on the surface of protoplast in 12 h after the wounding. Transmission electron microscopy showed that the protoplasmic mass began to form a continuous cell membrane at 6 h after the wounding. The newly generated cell membrane repeated collapse and rebuilding process several times until cell wall developed on the surface. Golgi bodies with numerous vesicles accumulated at the peripheral region of the rebuilding cell at 24 h after the wounding when the cell wall began to develop. Several layers of cell wall with distinctive electron density developed within 48-72 h after the wounding. Proteome profile changed dramatically at each stage of cell rebuilding process. Most proteins, which were up-regulated during the early stage of cell rebuilding disappeared or reduced significantly by 24-48 h. About 70-80% of protein spots detected at 48 h after the wounding were newly appeared ones. The expression pattern of 29 representative proteins was analyzed and the internal amino acid sequences were obtained using mass spectrometry. Our results showed that a massive shift of gene expression occurs during the cell-rebuilding process of B. plumosa.

수평원관 내 이산화탄소의 증발열전달 특성 연구 (A Study on the Characteristics of Evaporative Heat Transfer for Carbon Dioxide in a Horizontal Tube)

  • 조은석;윤석호;김민수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.104-107
    • /
    • 2000
  • Evaporative heat transfer characteristics of carbon dioxide has been investigated. Experiment has been carried out for seamless stainless steel tube with outer diameter of 9.55 mm and inner diameter of 7.75 mm. Direct heating method is used for supplying heat to the refrigerant was uniformly heated by electric current which was applied to the tube wall. The saturation temperature of refrigerant is calculated from the measured saturation pressure by using an equation of state. Inner wall temperature was calculated from measured outer wall temperature, accounting for heat generation in the tube and heat conduction through the tube wall. Mass Quality of refrigerant was calculated by considering energy balance in the preheater and the test section. Heat fluxes were set at 12, 16, 20, 23, and $27kW/m^2$, mass fluxes were controlled at 212, 318, 424, and $530 kg/m^2s$, and saturation temperature of refrigerant were adjusted at 0, 3.4, 6.7 and $10.5^{\circ}C$. From this study, heat transfer coefficients of carbon dioxide have been provided with respect to quality for several mass fluxes, heat fluxes. Finally, the experimental results in this study are compared with the correaltion by Gungor and Winterton(1987).

  • PDF

흉벽에 발생한 악성 임파종 [Non-Hodgkin`s lymphoma] 수술 치험 1예 (Malignant lymphoma [non-Hodgkin`s lymphoma] at left posterior chest wall)

  • 김송명
    • Journal of Chest Surgery
    • /
    • 제16권1호
    • /
    • pp.176-182
    • /
    • 1983
  • Malignant lymphoma in chest wall is a rare form of extranodal variety as occasionally localized tumor. The primary site is suggested from rib or soft tissue, but the incidence in rib is higher than soft tissue. The patient, a male, aged 32, noted a swelling and pain over the left lower posterior chest from 3 months prior to admission. Roentgenograms revealed bony destruction in left 9, & 19th ribs posteriorly and associated chest wall mass which was ill defined uncleared margination. Under diagnosis of malignant tumor, the operation was performed and the tumor mass resected widely with en bloc technique than the fascia lata was grafted at chest wall defect. The histology of specimen was disclosed as malignant lymphoma, non-Hodgkin`s diffuse lymphocytic poorly differentiated form. The radio-and chemotherapy were combined post-operatively and the complete remission is acquired.

  • PDF

경피적 폐생검술후 흉벽에 전이된 폐암;1례 보고 (Chest Wall Implantation of Lung Cancer after Percutaneous Fine Needle Aspiration - Report of one case -)

  • 원태희
    • Journal of Chest Surgery
    • /
    • 제25권7호
    • /
    • pp.707-710
    • /
    • 1992
  • Percutaneous needle aspiration has been widely used in the diagnosis of pulmonary lesions, because it is a fairly simple procedure with good diagnostic accuracy and low complication rate. Among its complications, the spread of malignant cells along the needle tract is rare but serious one. We report a case of chest wall implantation of lung cancer after the percutaneous fine needle aspiration biopsy. A 57-year-old man had undergone a right upper lobectomy for squamous cell carcinoma [T2N0M0] of the lung, 3 months after the operation, a growing mass, located far from the previous thoracotomy incision, developed on the right anterior chest wall where the diagnostic thin needle biopsy had been performed before the lobectomy. A wide excision of the chest wall mass was performed, and permanent histology showed squamous cell carcinoma as noted before.

  • PDF

사무소 건물을 위한 자연형 태양열 시스템의 응용 (Application of Passive Solar Systems for Office Buildings)

  • 박진서;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제30권4호
    • /
    • pp.22-28
    • /
    • 2010
  • This study analyzed the performance of passive solar system for office building. A unit model of the passive solar system was proposed in order to predict its performance under varying parameters and Seoul weather date. Steady state heat transfer equations were set up using a energy balanced equations and solved using a inverse matrix method. Numerical simulation program to analyze system was developed by using MATLAB. As the results, the passive solar system performance of office building was determined by the insolation and the outdoor air temperature. Also the passive solar system indicate 6.7~16.2% of annual average efficiency. In the comparison with other systems of the conventional wall, mass wall could reduce the heating loads of 7.1% and trombe wall could reduce heating loads of 11.5%. Through this study, performance of passive solar system for office building was verified by numerical method. Consequently, the passive solar system could operate an important role as the alternative for saving energy consumption of office building, and the additional studies should be made through the experimental method for the commercialization.

IMPROVEMENT OF CUPID CODE FOR SIMULATING FILMWISE STEAM CONDENSATION IN THE PRESENCE OF NONCONDENSABLE GASES

  • LEE, JEHEE;PARK, GOON-CHERL;CHO, HYOUNG KYU
    • Nuclear Engineering and Technology
    • /
    • 제47권5호
    • /
    • pp.567-578
    • /
    • 2015
  • In a nuclear reactor containment, wall condensation forms with noncondensable gases and their accumulation near the condensate film leads to a significant reduction in heat transfer. In the framework of nuclear reactor safety, the film condensation in the presence of noncondensable gases is of high relevance with regards to safety concerns as it is closely associated with peak pressure predictions for containment integrity and the performance of components installed for containment cooling in accident conditions. In the present study, CUPID code, which has been developed by KAERI for the analysis of transient two-phase flows in nuclear reactor components, is improved for simulating film condensation in the presence of noncondensable gases. In order to evaluate the condensate heat transfer accurately in a large system using the two-fluid model, a mass diffusion model, a liquid film model, and a wall film condensation model were implemented into CUPID. For the condensation simulation, a wall function approach with a heat/mass transfer analogy was applied in order to save computational time without considerable refinement for the boundary layer. This paper presents the implemented wall film condensation model, and then introduces the simulation result using the improved CUPID for a conceptual condensation problem in a large system.

Water transport through hydrophobic micro/nanoporous filtration membranes on different scales

  • Mian, Wang;Yongbin, Zhang
    • Membrane and Water Treatment
    • /
    • 제13권6호
    • /
    • pp.313-320
    • /
    • 2022
  • Theoretical calculation results are presented for the enhancement of the water mass flow rate through the hydrophobic micro/nano pores in the membrane respectively on the micrometer and nanometer scales. The water-pore wall interfacial slippage is considered. When the pore diameter is critically low (less than 1.82nm), the water flow in the nanopore is non-continuum and described by the nanoscale flow equation; Otherwise, the water flow is essentially multiscale consisting of both the adsorbed boundary layer flow and the intermediate continuum water flow, and it is described by the multiscale flow equation. For no wall slippage, the calculated water flow rate through the pore is very close to the classical hydrodynamic theory calculation if the pore diameter (d) is larger than 1.0nm, however it is considerably smaller than the conventional calculation if d is less than 1.0nm because of the non-continuum effect of the water film. When the driving power loss on the pore is larger than the critical value, the wall slippage occurs, and it results in the different scales of the enhancement of the water flow rate through the pore which are strongly dependent on both the pore diameter and the driving power loss on the pore. Both the pressure drop and the critical power loss on the pore for starting the wall slippage are also strongly dependent on the pore diameter.

욕조의 보온성능연구 (A Performance Equation of Bath Tubs)

  • 이병호;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

Sway Added Mass of a Rectangular Cylinder in a Restricted Water

  • Hwang, J.H.;Rhee, K.P.;Kang, C.K.
    • 대한조선학회지
    • /
    • 제19권1호
    • /
    • pp.3-14
    • /
    • 1982
  • In this paper, the sway added mass of a rectangular cylinder in a restricted water is considered by applying Hamilton's principle as the frequency tends to zero. The present method is an extension of Isshiki's method proposed in 1978. In the present method, it is assumed that the fluid velocity distribution in each subdomain of the fluid can be represented by higher order polynomials while Isshiki assumed linear velocity distribution. The fluid flow is assumed as a rotational motion in the present analysis. However, the results obtained from the present method show good agreement with Bai's numerical results for the case of large clearances between a canal wall and a cylinder. From Kelvin's minimum energy theorem, we can see that the value of sway added mass obtained from the present method approaches the upper bound. The approximate formula obtained in the present study takes a simple form which consists of the dimensions of the canal and the cylinder. The present formulae are derived for the cases of a rectangular cylinder swaying at the center of a narrow or wide canal relative to a cylinder, at off-center location in a canal, and in the restricted water with a single wall. From the results of numerical calculation, it is concluded that the sway added mass in restricted waters is more affected by water depth than clearance between a wall and a cylinder.

  • PDF