• Title/Summary/Keyword: Mass measurement type

Search Result 156, Processing Time 0.025 seconds

Adiabatic Characteristics of Concrete Temperature with Economical Negative Temperature Coefficient Ceramics Sensor System (경제적인 NTC 세라믹스 온도센서 시스템을 이용한 콘크리트 수화열 계측에 관한 실험적 연구)

  • 김기수;김종우;전재홍;하재담;김태홍
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.391-396
    • /
    • 2001
  • In order to estimate thermal cracking in mass concrete and to decide the removal time of the forms outside the concrete structures in wintertime, temperature measurement is indispensible. Until now, the measurement system employs thermocouple type. In this paper, we introduce economical and accurate NTC(Negative Temperature Coefficient) ceramic type measurement system. In principle, NTC ceramic type sensor is very sensitive in the range -20~15$0^{\circ}C$. In this range, the signal change is so large that the sensor needs less amplification than thermocouple. Therefore, not only the sensor itself is inexpensive but also the system is too. In this experiments the temperature of the NTC system are identical to those of thermocouple. In conclusion, inexpensive NTC thermistor system is very adequate to the temperature measurement during concrete curing.

  • PDF

Boron Detection Technique in Silicon Thin Film Using Dynamic Time of Flight Secondary Ion Mass Spectrometry

  • Hossion, M. Abul;Arora, Brij M.
    • Mass Spectrometry Letters
    • /
    • v.12 no.1
    • /
    • pp.26-30
    • /
    • 2021
  • The impurity concentration is a crucial parameter for semiconductor thin films. Evaluating the impurity distribution in silicon thin film is another challenge. In this study, we have investigated the doping concentration of boron in silicon thin film using time of flight secondary ion mass spectrometry in dynamic mode of operation. Boron doped silicon film was grown on i) p-type silicon wafer and ii) borosilicate glass using hot wire chemical vapor deposition technique for possible applications in optoelectronic devices. Using well-tuned SIMS measurement recipe, we have detected the boron counts 101~104 along with the silicon matrix element. The secondary ion beam sputtering area, sputtering duration and mass analyser analysing duration were used as key variables for the tuning of the recipe. The quantitative analysis of counts to concentration conversion was done following standard relative sensitivity factor. The concentration of boron in silicon was determined 1017~1021 atoms/㎤. The technique will be useful for evaluating distributions of various dopants (arsenic, phosphorous, bismuth etc.) in silicon thin film efficiently.

Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type (Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교)

  • Kim, M.S.;Kwon, J.W.;Chung, M.C.;Lee, J.W.
    • Journal of ILASS-Korea
    • /
    • v.17 no.4
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

Characteristics of T-phase flow distribution and pressure drop in a horizontal T-type evaporator tube (수평 T형 증발관내 2상류의 유량분배 및 압력강하 특성)

  • 박종훈;조금남;조홍기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.658-668
    • /
    • 1999
  • The objective of the present study is to investigate the effect of experimental parameters on the hydrodynamic characteristics in a horizontal tee-type evaporator using R-22. The experimental apparatus consisted of an unheated tee-type test section, a liquid-vapor separator, a preheated, mass flow meters, a plate heat exchanger, pump, and other measurement devices. The experimental parameters were mass flux(500 and 600kg/$m^2$s), inlet quality(0.1~0.3) and separation ratio(0.3~0.7). Absolute pressure at the inlet of the test section was 0.652 MPa. The branch-to-inlet inner diameter ratio was 0.61. Pressure gradient at the branch section was larger than that at the run section at the same separation ratio. Pressure drop per unit length increased at the run section and decreased at the branch section as the separation ratio increased. Pressure drop predicted by the separated flow model agreed with experimental data within -35 to +16%. Generally, predicted values showed similar trend with the data. Mass flow ratio of vapor refrigerant was affected by the inlet quality more than the mass flux.

  • PDF

Micro-Fabrication and Thermal Characteristics of a Thermal Mass Air Flow Sensor for Real-time Applications (고응답 열식 질량공기유량센서의 제작 및 열거동 특성)

  • Park, Byung-Kyu;Lee, Joon-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.7
    • /
    • pp.542-548
    • /
    • 2008
  • A thermal mass air flow sensor (MAFS), which consists of a micro-heater and thermo-resistive sensors on the silicon-nitride ($Si_3N_4$) thin membrane structure, is micro-fabricated by MEMS processes. Two thermo-resistive temperature sensors are located at $100{\mu}m$ upstream and downstream from the micro-heater respectively. The thermal characteristics are measured to find the best measurement indicator. The micro-heater is operated under constant power condition, and four flow indicators are investigated. The normalized temperature indicator shows good physical meaning and is easy to use in practice. It is found that the configurations and heating power of thermal-resistive elements are the dominant factors to determine the range of the flow measurement in the MAFS with higher sensitivity and accuracy.

Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System (3실형 인버터 열펌프 시스템의 냉방성능 측정)

  • 정광진;최영돈;장효환;송재복;박윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

Measurement and Control of Swing Motion Using Image Sensor (이미지 센서를 이용한 크레인의 흔들림 계측 및 제어)

  • Kim, Y.B.;Kawai, H.;Choi, Y.W.;Lee, K.S.;Chae, G.H.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.103-108
    • /
    • 2007
  • In general, the swing motion of the crane is controlled and suppressed by activating the trolley motion. In many papers reported by us, we suggested a new type of anti-sway control system of the crane. In the proposed control system, a small auxiliary mass(moving-mass) is installed on the spreader and the swing motion is controlled by moving the auxiliary mass. The actuator reaction against the auxiliary mass applies inertial control forces to the container in order to reduce the swing motion in the desired manner. The measuring system is based on laser sensor or others. However it is not so useful in real world. Especially, in this paper, the image sensor is used to measures the motions of the spreader and the measured data are fed back to the controller in real time. The applied image processing technique is a kind of robust template matching method which is named Vector Code Correlation (VCC) and devised to consider the real environmental conditions. And the $H_{\infty}$ based control technique is applied to suppress swing motion of the crane. And the experimental result shows that the proposed measurement system based on image sensor and control system is useful and robust to disturbances.

  • PDF

Measurement of Mass Transfer Coefficients in a Benzene Adsorption Process (벤젠 흡착공정에서의 물질전달계수에 관한 연구)

  • Kwon, Jun-Ho;Choi, Moon-Kyu;Suh, Sung-Sup
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.47-52
    • /
    • 2008
  • Among various mass transfer models to express adsorption rates for any adsorption processes, the linear driving force (LDF) model is used most. The present investigation aims at finding whether this model may be applied to real adsorption process for separation and removal of benzene. Comparison of numerical simulation results calculated by the LDF model with experimental data allowed us to find the mass transfer coefficients that are most appropriate for a specific adsorption process. Various breakthrough curves were obtained from experiments performed at many different temperatures and pressures, which in turn produced suitable mass transfer coefficients. These dependencies of mass transfer coefficient on temperature and pressure were represented by an Arrhenius type- and a power law type empirical equation, respectively.

  • PDF

A Study on the Heat Release Rate of EPS Sandwich Panel Core (EPS 샌드위치 패널 심재의 열방출율에 관한 연구)

  • Park, Hyung-Ju;Cho, Myung-Ho
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.72-78
    • /
    • 2008
  • The mass loss rate and heat release rate of EPS sandwich panel cores were analysed using variable external irradiation level. The experimental materials were exposed to incident heat fluxes form 20 to 50 kW/$m^2$. For the measurement of mass loss rate and heat release rate, the size of specimen was $100mm{\times}100mm{\times}50mm$ and the samples were 3 different kinds. The combustion heat were carried out from the Oxygen bomb calorimeter and the mass loss rate and heat release rate were carried out from the Mass loss calorimeter according to ISO 5660-1. As the results of this study, the mass loss rate of Type A, B, and C were 2.7 g/$m^2s$, 2.8 g/$m^2s$, and 2.3 g/$m^2s$ and the heat release rate of Type A, B, and C were 58.23 kW/$m^2$, 47.19 kW/$m^2$, and 50.06 kW/$m^2$ respectively at the heat flux of 50 kW/$m^2$. In conclusion, when the heat release characteristics applied to a classification system of Canada, Type A and C can be classified grade C-3, and Type C can be classified grade C-2 from all data of this study.

Relationship between Characteristics of Five Types of Obese Woman based on Physical Tests and Fei-kao-liuren based on Oriental Medical Theory (여성(女性) 비만(肥滿) 유형별 검사특성과 비고육인(肥膏肉人)과의 관계)

  • Jin Seng-Hee;Choi Kyung-Mee;Park Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.27 no.2 s.66
    • /
    • pp.145-154
    • /
    • 2006
  • Objectives : Methods to evaluate obesity are growing to be important in studying links between health and disease. Physicians are using BMI (body mass index) to evaluate obesity, but they can't know how much fat the body has by using that method. Even though there are several assessments, there are different scales, so patients are diagnosed as obese, by some but not by others. These studies are limited in evaluating obesity; it is necessary to study based on new knowledge. According to Oriental Medical Theory, obese people are categorized into 3 types, Fei, Kao and Liu Ren. They have different pathology and body shapes than non-obese people. The relationship between Oriental Medical Theory and BMI and assessment of body fat is a fundamental need to easily approach and treat obesity. Methods : At 00 Oriental Medical Center, 145 female subjects who intended to lose weight were given physical tests and grouped into 5 types of obesity. The physical tests were height measurement, BMI, body composition (body fat mass and lean body mass), skin elasticity and physical strength tests. One-way analysis of variance was done to compare the means of physical tests between the five types of obese women. There was some relationship between characteristics of the five types based on physical tests and Fei, Kao and Liu Ren based on Oriental Medical Theory. Least significant difference (LSD) was used in multiple comparisons. Results : 1. According to the skin elasticity test, obesity type 5 placed between obesity types 3 and 4 and obesity types 1 and 2. Obesity types 3 and 4 were in the low skin elasticity result group; obesity types 1 and 2 were in the high ones (p<0.1).Based on Oriental Medical Theory, Fei Ren and Kao Ren can be distinguished by skin elasticity degree. This result should form the basis of obesity diagnosis. 2. According to Oriental Medical Theory, Fei Ren is smaller than others. Based on height measurement, obesity types 3 and 4 were significantly lower than other obesity types (p<0.1), so there is a relationship between Fei Ren and obesity types 3 & 4. 3. There were significant differences between obesity type 2 and obesity type 4 in the body fat mass result (p<0.1). This study did not have large enough a sample size to distinguish Liu Ren. Conclusions : Further clinical research is necessary to study measurement methods of body shape type and skin elasticity for distinguishing Fei Ren from Kao Ren. The diagnosis and treatment based on the relationship of these types should be studied further.

  • PDF