• 제목/요약/키워드: Mass aerosol

검색결과 282건 처리시간 0.023초

1994년 6월 서울지역 시정장애의 측정 및 분석 (Measurement and Analysis of Visibility lmpairment during June, 1994 in Seoul)

  • 백남준;이종훈;김용표;문길주
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.407-419
    • /
    • 1996
  • Characteristics of visual air quality in Seoul have been investigated between June 13 and 21, 1994. Optical properties (extinction coefficient and particle scattering coefficient), meteorological parameters (relative humidity, temperature, wind speed, wind direction, and cloud cover), particle characteristics (mass size distribution, components) were measured and analyzed. During measurement periods, northwest wind with less than 2m/sec of wind speed deteriorates visibility. Effects of relative humidity are though to be not a direct factor which influence to visibility through the size change due to hygroscopic species in aerosol. During the smoggy period both the aerosol mass concentration and fine particle fraction of the size distribution are increased compared to the clear period. Sulfate, organic carbon, and elemental carbon in aerosol are the major species in determining the occurrence and severity of a smog in Seoul.

  • PDF

드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정 (Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone)

  • 김희상;박용희;김우영;은희람;안강호
    • 한국입자에어로졸학회지
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

Enhancement of Aerosol Concentration in Korea due to the Northeast Asian Forest Fire in May 2003

  • In, Hee-Jin;Kim, Yong-Pyo;Lee, Kwon-H.
    • Asian Journal of Atmospheric Environment
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Enhancement of aerosol optical thickness (AOT) and surface aerosol mass concentration in Korea for an active forest fire episode in Northeast Asia were estimated by Community Multi-scale Air Quality (CMAQ) model. MODIS/TERRA remote detects of fires in Northeast Asia for May 2003 gave a constraint for estimation of wildfire emissions with an NDVI distribution for recent five years. The simulated wildfire plumes and enhancement of AOT were evaluated and well resolved by comparing multiple satellite observations such as MODIS, TOMS, and others. Scatter plots of observed daily mean aerosol extinction coefficient versus $PM_{10}$ concentration in ground level in Korea showed distinctively different trends based on the ambient relative humidity.

흡습성 에어로졸의 거동에 미치는 수증기 응축의 영향 (The effect of steam condensation on the behavior of an hygroscopic aerosol)

  • 박재우
    • 한국분무공학회지
    • /
    • 제3권3호
    • /
    • pp.14-22
    • /
    • 1998
  • The growth by steam condensation of an hygroscopic aerosol is investigated using the condensation rate model which has been derived from the mass and heat transfer equations. The present model accounts for both the solute and Kelvin effects. When the hygroscopicity is considered, condensation can occur on hygroscopic seed particles even under subsaturated steam conditions. This study focuses on the effect of hygroscopicity on the evolution of the particle size distribution and decay of the total aerosol concentration. It is found that hygroscopicity causes the particle size distribution to rapidly move upward even in a very short time, resulting in substantially higher decay of the total aerosol concentration than the case without considering hygroscopicity.

  • PDF

Semiempirical model for wet scrubbing of bubble rising in liquid pool of sodium-cooled fast reactor

  • Pradeep, Arjun;Sharma, Anil Kumar
    • Nuclear Engineering and Technology
    • /
    • 제50권6호
    • /
    • pp.849-853
    • /
    • 2018
  • Mechanistic calculations for wet scrubbing of aerosol/vapor from gas bubble rising in liquid pool are essential to safety of sodium-cooled fast reactor. Hence, scrubbing of volatile fission product from mixed gas bubble rising in sodium pool is presented in this study. To understand this phenomenon, a theoretical model has been setup based on classical theories of aerosol/vapor removal from bubble rising through liquid pools. The model simulates pool scrubbing of sodium iodide aerosol and cesium vapor from a rising mixed gas bubble containing xenon as the inert species. The scrubbing of aerosol and vapor are modeled based on deposition mechanisms and Fick's law of diffusion, respectively. Studies were performed to determine the effect of various key parameters on wet scrubbing. It is observed that for higher vapor diffusion coefficient in gas bubble, the scrubbing efficiency is higher. For aerosols, the cut-off size above which the scrubbing efficiency becomes significant was also determined. The study evaluates the retention capability of liquid sodium used in sodium-cooled fast reactor for its safe operation.

Target Transformation Factor Analysis를 이용한 부산시 분진오염원의 양적 추정 (Quantitative Source Estimation of Particulate Matters in Pusan Area Using the Target Transformation Factor Analysis)

  • 김태오;김동술;나진균
    • 한국대기환경학회지
    • /
    • 제6권2호
    • /
    • pp.135-146
    • /
    • 1990
  • The purpose of the study was to identify sources of particulate matters statistically and to estimate the mass contribution quantitatively in the Pusan metropolitan area. Then, the study has used the TTFA (target transformation factor analysis) model, a receptor model, to apportion aerosol mass with the raw data of 106 ambient samples characterized by 24 heavy metal variables. The TTFA was extensively applied to generate source profiles and their aerosol mass contributions. Though a couple of sources were not identified, four to seven sources were able to be extracted at 3 different sites (Jang Rim-Dong, Kwang Bok-Dong, and Kwang An-Dong) in Pusan area and finally mass conributions could be calculated.

  • PDF

Fast Screening of Harmful Disinfectants in Household Products via Low-Temperature Plasma Ionization-Mass Spectrometry

  • Lee, Hyoung Jun;Kweon, Gi Ryang;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • 제8권2호
    • /
    • pp.44-47
    • /
    • 2017
  • Isothiazolinone derivatives are widely used in consumer products as disinfectants or preservatives, but there are growing concerns about their impact on human health. Therefore, rapid screening of these biocides is very important for proper control and regulation of potentially hazardous substances. To this end, low-temperature plasma (LTP) ionization mass spectrometry (MS) was investigated to demonstrate its potential for direct and selective analysis of isothiazolinones from sprayed aerosol samples. Benzisothiazolinone (BIT) was clearly identified from a commercial fabric deodorant using LTP ionization MS and MS/MS. LTP allowed selective ionization of BIT directly from the simply sprayed aerosol sample and illustrated its potential for fast screening without sample pre-treatments. Selective nature of LTP ionization, on the other hands, implicates use of LTP ionization MS as a general screening method for specific groups of hazardous chemicals in commercial products.

Application of Representative $PM_{2.5}$ Source Profiles for the Chemical Mass Balance Study in Seoul

  • Kang, Choong-Min;Kang, Byung-Wook;SunWoo, Young;Lee, Hak-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제24권E1호
    • /
    • pp.32-43
    • /
    • 2008
  • Source samples were collected to construct source profiles for 9 different source types, including soil, road dust, gasoline/diesel-powered vehicles, a municipal incinerator, industrial sources, agricultural/biomass burning, marine aerosol, and a coal-fired power plant. Seasonal profiles for 'Chinese aerosol', aerosols derived from the urban area of China, were reconstructed from seasonal $PM_{2.5}$ compositions reported in Beijing, China. Ambient $PM_{2.5}$ at a receptor site was also measured during each of the four seasons, from April 2001 to February 2002, in Seoul. The Chemical Mass Balance receptor model was applied to quantify source contributions during the study period using the estimated source profiles. Consequently, motor vehicle exhaust (33.0%), in particular 23.9% for diesel-powered vehicles, was the largest contributor affecting the $PM_{2.5}$ levels in Seoul, followed by agricultural/biomass burning (21.5%) and 'Chinese aerosol' (13.1%), indicating contributions from long-range transport. The largest contributors by season were: for spring, 'Chinese aerosol' (31.7%); for summer, motor vehicle exhaust (66.9%); and for fall and winter, agricultural/biomass burning (31.1% and 40.1%, respectively). These results show different seasonal patterns and sources affecting the $PM_{2.5}$ level in Seoul, than those previously reported for other cities in the world.

흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경 (Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;이기남
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

축산관련차량 이동에 따른 도로의 에어로졸 발생량 분석 (Aerosol Emission from Road by Livestock Transport Vehicle Movement)

  • 서일환;이인복;황현섭;배연정;배승종;문운경
    • 농촌계획
    • /
    • 제19권4호
    • /
    • pp.137-147
    • /
    • 2013
  • Most of livestock houses are concentrated in certain area with mass rearing system resulting in rapid spread of infectious diseases such as HPAI (highly pathogenic avian influenza). The livestock-related vehicles which frequently travel between farms could be a major factor for disease spread by means of transmission of airborne aerosol including pathogens. This study was focused on the quantitative measurement of aerosol concentration by field experiment while vehicles were passing through the road. The TSP (total suspended particle) and PM10 (particle matter) were measured using air sampler with teflon filter installed downward the road with consideration of weather forecast and the direction of road. And aerosol spectrometer and video recorders were also used to measure the real-time distribution of aerosol concentration by its size. The results showed that PM2.5 was not considerable for transmission of airborne aerosol from the livestock-related vehicle. The mass generated from the road during the vehicle movement was measured and calculated to 241.4 ${\mu}g/m^3$ by means of the difference between TSP and PM2.5. The dispersion distance was predicted by 79.6 m from the trend curve.