• Title/Summary/Keyword: Mass Estimation

Search Result 775, Processing Time 0.025 seconds

The monitoring of some heavy metals in oriental mineral medicines (광물성 생약 중 중금속의 모니터링)

  • Han, Eunjung;Chung, Jaeyeon;Park, Kyungsu;Kang, Inho;Kang, Sinjung;Kim, Yunje
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.480-486
    • /
    • 2008
  • This paper reports on the monitoring results of some heavy metals (Pb, Cd, As and Hg) in oriental mineral medicines. Levels of Pb, Cd and As were determined using the acid digestion method and ICP-MS. Hg levels were determined using the gold amalgamation method and Automatic mercury analyzer (AMA). The results indicated that, in the case of Pb, 25.81% (24 cases) of the samples were over MRL (5 mg/kg). Pb levels in Calamina, Pumex, and Cinnabaris exceeded MRL (5 mg/kg). In the case of Cd, 9.68% (17cases) of the samples were over MRL (0.3 mg/kg). Cd levels in Calamina, Pumex and Cinnabaris were exceeded MRL (0.3 mg/kg). In case of As, 24.73% (23 cases) of samples exceeded MRL (3 mg/kg). As levels in Calamina, Lithargyrum, Vermilionum, Cinnabaris and Chalcocitum exceeded MRL (3 mg/kg). In the case of Hg, it was shown that the 76.34% (78 cases) of the samples exceeded MRL (0.2 mg/kg). Hg levels in almost all the samples exceeded MRL (0.2 mg/kg). These results led us to recommend that the domestic commercial law to be legislated to ensure the quality estimation and safety of oriental mineral medicines.

Variations of Serving Sizes and Composition of Manufactured Milk and Soymilk Products and Implications for Dietary Assessment (시판되는 우유와 두유 제품의 제공량 및 성분의 다양성이 식이섭취조사에 미치는 영향)

  • Noh, Hwa-Young;Jang, Eun-Joo;Shim, Jae-Eun;Park, Min-Kyung;Paik, Hee-Young
    • Journal of the Korean Society of Food Culture
    • /
    • v.23 no.1
    • /
    • pp.33-40
    • /
    • 2008
  • Accuracy of dietary assessment depends on correct estimation of quantity as well as correct data on composition of the products. Milk and soymilk were considered quite homogeneous in items of package size and composition. One serving size of fluid milk and soymilk is considered 200 mL but there are products with different amounts on the market. This study was conducted to investigate variations of amounts and composition of fluid milk and soymilk products of one portion siz on Korean market. Twenty-nine milk products were purchased and categorized into 8 groups-regular, low-fat, skim, chocolate, strawberry-flavored, banana-flavored, and black soybean-added. Sixteen fluid soymilk products were purchased and categorized into 4 groups-regular, infant, black sesame or black soybean added and others. Actual volume of each product was measured by mass cylinder and compositions of major nutrients on the package were compared to the values in the most widely used nutrient DB in Korea. Amounts of milk specified on the package of purchased products were 182.3-318.5 ml, the largest being banana-flavored milk. Amounts of soy milk were 184.3-240.5 mL, the largest being regular soymilk. Measured amount of each products were close to the amount on the package (<5%). Contents of macronutrients on the package were different from the food composition table in several products. The amounts of calcium varied greatly among the products due to the popularity of adding calcium to milk and soymilk products recently. These variations in the amount and contents of major nutrients in milk and soymilk products can lead to considerable error to the results of dietary assessment unless the amount and the composition of each product are regularly updated in the food composition table whenever the new products are introduced in the market.

Comparative Investigation of Convective Heat Transfer Coefficients for Analyzing Compressed Hydrogen Fueling Process (압축 수소 충전 공정 해석을 위한 대류 열전달 계수 비교 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.123-133
    • /
    • 2023
  • Commercial hydrogen fuel cell vehicles are charged by compressing gaseous hydrogen to high pressure and storing it in a storage tank in the vehicle. This process causes the temperature of the gas to rise, to ensure the safety to storage tanks, the temperature is limited. Therefore, a heat transfer model is needed to explain this temperature rise. The heat transfer model includes the convective heat transfer phenomenon, and accurate estimation is required. In this study, the convective heat transfer coefficient in the hydrogen fueling process was calculated and compared using various correlation equations considering physical phenomena. The hydrogen fueling process was classified into the fueling line from the dispenser to the tank inlet and the storage tank in the vehicle, and the convective heat transfer coefficients were estimated according to process parameters such as mass flow rate, diameter, temperature and pressure. As a result, in the case of the inside of the filling line, the convective heat transfer coefficient was about 1000 times larger than that of the inside of the storage tank, and in the case of the outside of the filling line, the convective heat transfer coefficient was about 3 times larger than that of the outside of the storage tank. Finally, as a result of a comprehensive analysis of convective heat transfer coefficients in each process, it was found that outside the storage tank was lowest in the entire hydrogen fueling process, thus dominated the heat transfer phenomenon.

Biogeochemical Organic Carbon Cycles in the Intertidal Sandy Sediment of Nakdong Estuary (낙동강 하구 갯벌 사질 퇴적물에서 생지화학적 유기탄소순환)

  • Lee, Jae-Seong;Park, Mi-Ok;An, Soon-Mo;Kim, Seong-Gil;Kim, Seong-Soo;Jung, Rae-Hong;Park, Jong-Soo;Jin, Hyun-Gook
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.4
    • /
    • pp.349-358
    • /
    • 2007
  • In order to understand biogeochemical cycles of organic carbon in the permeable intertidal sandy sediments of the Nakdong estuary, we estimated the organic carbon production and consumption rates both in situ and in the laboratory. The Chl-a content of the sediment and the nutrient concentrations in below surface pore water in the sandy sediment were lower than in the muddy sediment. The sediment oxygen consumption rates were relatively high, especially when compared with rates reported from other coastal muddy sediments with higher organic carbon contents. This implied that both the organic carbon degradation and material transport in the sandy sediment were enhanced by advection-related process. The simple mass balance estimation of organic carbon fluxes showed that the major sources of carbon in the sediment would originate from benthic microalgae and detrital organic carbon derived from salt marsh. The daily natural biocatalzed filtration, extrapolated from filtration rates and the total area of the Nakdong estuary, was one order higher than the maximum capability of sewage plants in Busan metropolitan city. This implies that the sandy sediment contributes greatly to biogeochemical purification in the area, and is important for the re-distribution of materials in the coastal environment.

Analysis of Nutrient Cycling Structure of a Korean Beef Cattle Farm Combined with Cropping as Affected by Bedding Material Types (깔개물질의 종류에 따른 한우-경종 결합 농가의 양분순환 구조 분석)

  • Lim, Sang-Sun;Kwak, Jin-Hyeob;Park, Hyun-Jung;Lee, Sun-Il;Lee, Dong-Suk;Kim, Yong-Soon;Yun, Bong-Ki;Kim, Sun-Woo;Choi, Woo-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • In this study, we analyzed nutrient cycling structure of a small farm (cattle of 100 heads and arable lands of 2.5 ha) in Jeonnam province to investigate the effects of nutrients input by the addition of bedding materials (sawdust and rice hull) and nutrients loss before the application to the soils (the period during manure storage in the feedlot and composting process) on nutrient cycling structure. Sawdust and rice hull added as bedding materials increased N by 1.6% and 14.2% and $P_2O_5$ by 3.1% and 27.4%, respectively, relative to the amount of nutrients produced by excretion. This result suggests that the addition of nutrients via bedding materials should be considered for better estimation of nutrient balance. The most significant characteristics of the nutrient cycling structure was loss of mass and nutrients during the storage (21 days) and composting period (90 days). During this period, 78.4% of N and 9.5% of $P_2O_5$ was lost from sawdust compost; meanwhile, the percentages of loss for rice hull compost were 81.6% and 10.3%, respectively. A lower percentage of nutrients loss in sawdust compost than that in rice hull compost was attributed to the relatively slow decomposition rate of organic materials in the sawdust compost which has higher C/N ratio and lignin contents. Therefore, it was concluded that estimation of nutrient balance should be conducted based on nutrient contents in the final compost being applied to the lands rather than the amount of nutrients contained in the livestock excretion. In addition, the effects of bedding materials on nutrient losses should be also taken into account.

Estimation of Specific Leaf Area Index Using Direct Method by Leaf Litter in Gwangneung, Mt. Taewha and Mt. Gariwang (광릉숲, 태화산, 가리왕산 활엽수림에서 낙엽에 의한 수종별 엽면적지수 추정)

  • Kwon, Boram;Jeon, Jihyeon;Kim, Hyun Seok;Yi, Myong Jong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.1
    • /
    • pp.1-15
    • /
    • 2016
  • Annual litterfall production and leaf area index (LAI, $m^2/m^2$) were estimated using litter traps in Gwangneung, Mt. Taewha and Mt. Gariwang. Annual total litter fall production including branch, bark, others was the highest in Gwangneung($7497.3{\pm}326.5kg/ha/yr$), which had the highest basal area at late successional stage, and followed by Mt. Taewha($5929.1{\pm}225.8kg/ha/yr$) and Mt. Gariwang($3,210.1{\pm}220.1kg/ha/yr$). Mt. Gariwang had the lowest litterfall production due to high elevation and short growing season even with the higher stand density and basal area than Mt. Taewha. Similarly, LAI, which was calculated by multiplying the mass of leaf litter with specific leaf area, was the highest in Gwangneung($5.99{\pm}0.69$) and followed by Mt. Taewha($5.20{\pm}0.24$) and Mt. Gariwang($4.06{\pm}0.42$) and the upper canopy species had the highest leaf area index in every sites (Gwangneung : 4.72, Mt. Taewha : 3.08, Mt. Gariwang : 2.19). However, species specific LAI estimation based on the relationship between basal area and leaf area was limited due to upper canopy species non-proportionality of basal area with LAI. In addition, the comparison between direct and indirect LAI measurement showed the importance of canopy clumping, especially at high density. Our study emphasized the necessity of direct LAI measurement using litter fall traps especially at temperate deciduous forest with diverse species.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Estimation of Domestic Greenhouse Gas Emission of Refrigeration and Air Conditioning Sector adapting 2006 IPCC GL Tier 2b Method (국내 냉동 및 냉방부문 온실가스 배출량 산정 - 2006 IPCC GL Tier 2b 적용 -)

  • Shin, Myung-Hwan;Lyu, Young-Sook;Seo, Kyoung-Ae;Lee, Sue-Been;Lim, Cheolsoo;Lee, Sukjo
    • Journal of Climate Change Research
    • /
    • v.3 no.2
    • /
    • pp.117-128
    • /
    • 2012
  • The Government of South Korea has continued its effort to fixate virtuous circle of economic growth and climate change response to cope with international demands and pressure to commitment for greenhouse gas reduction effectively. Nationally, Korean Government has established "Enforcement of the Framework Act on Low carbon, Green Growth"(2010. 4. 13) to implement national mid-term GHG mitigation goal(30% reduction by 2020 compare to BAU), which established the foundation for phased GHG mitigation by setting up the sectoral and industrial goal, adopting GHG and Energy Target Management System. Also, follow-up measures are taken such as planning and control of mid-term and short-term mitigation target by detailed analysis of potential mitigation of sector and industry, building up the infrastructure for periodic and systematic analysis of target management. Likewise, it is required to establish more accurate, reliable and detailed sectoral GHG inventory for successfully establishment and implement the frame act. In comparison to the $CO_2$ emission, Especially fluorinated greenhouse gases (HFCs, PFCs, $SF_6$) are lacking research to build the greenhouse gas inventories to identify emissions sources and collection of the applicable collection activities data. In this study, with the refrigeration and air conditioning sector being used to fluorine refrigerant(HFCs) as the center, greenhouse gas emission estimation methodology for evaluating the feasibility of using this methodology look over and mobile air conditioning, fixed air conditioning, household refrigeration equipment, commercial refrigeration equipment for the greenhouse gas emissions were calculated. First look at in terms of methodology, refrigeration and air conditioning sector GHG emissions in developing country-specific emission factors and activity data of the industrial sector the construction of the DB is not enough, it's 2006 IPCC Guidelines Tier 2a (emission factor approach) rather than the Tier 2b (mass balance approach) deems appropriate, and each detail by process, sectoral activity data more accurate, if DB is built Tier 2a (emission factor approach) can be applied will also be judged. Refrigeration and air conditioning sector in 2009 due to the use of refrigerant greenhouse gas emissions ($CO_2eq.$) assessment results, portable air conditioner 1,974,646 ton to year, fixed-mount air conditioner 1,011,754 ton to year, household refrigeration unit 4,396 ton to year, commercial refrigeration equipment 1,263 ton to year was estimated to total 2,992,037 tons.

Estimation of the Required Number of Fan Coil Unit for Surplus Solar Energy Recovery of Greenhouse (온실의 잉여 태양에너지 회수용 FCU 소요대수 검토)

  • Yun, Sung-Wook;Choi, Man Kwon;Kim, Ha Neul;Kang, Donghyeon;Lee, Siyoung;Son, Jinkwan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.83-88
    • /
    • 2016
  • In this study, previously reported surplus solar energy-related study result and current status of fan coil unit (FCU) for cooling and heating installed in the current sites were briefly examined and then a method to determine the number of FCUs required to recover surplus solar energy was schematically proposed to provide basic data for researchers and technical engineers in this field. The maximum, mean, and minimum outside temperatures during the experiment period were about $28.2^{\circ}C$, $4.4^{\circ}C$, and $-11.5^{\circ}C$, respectively. The horizontal surface solar radiation level outside the greenhouse was in a range of $0.8-20.5MJ{\cdot}m^{-2}$ and mean and total solar radiation were $10.8MJ{\cdot}m^{-2}$ and $1,187.5MJ{\cdot}m^{-2}$. The mean temperature and relative humidity in the greenhouse during the daytime were in a range of 18.8-45.5 and 53.5-77.5%. The total surplus solar energy recovered from the greenhouse during the experiment period was approximately 6,613.4MJ, which could supplement about 6.7% of the total heating energy 98,600.2 MJ. In addition, the number of FCUs installed for heating varies case to case, although similar FCUs are used. Thus, it is necessary to study the installation height, orientation and installation distance as well as the appropriate number of FCUs from the efficient and economical viewpoints. The required numbers of FCUs for surplus solar energy recovery were 8.4-10.9units and 6.1-8.0units based on air mass and circular flow rate that passed through the FCUs. Considering calculation methods and the risks such as efficiency and use environments of FCUs, it was found that about nine units (one unit per $24m^3$ approximately) needed to be installed. The required number of FCUs for surplus solar energy recovery was around one unit per $24m^3$ approximately.

Development of Normalized Difference Blue-ice Index (NDBI) of Glaciers and Analysis of Its Variational Factors by using MODIS Images (MODIS 영상을 이용한 빙하의 정규청빙지수(NDBI) 개발 및 변화요인 분석)

  • Han, Hyangsun;Ji, Younghun;Kim, Yeonchun;Lee, Hoonyol
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.481-491
    • /
    • 2014
  • Blue-ice area is a glacial ice field in ice sheet, ice shelf and glaciers where snow ablation and sublimation is larger than snowfall. As the blue-ice area has large influences on the meteorite concentration mechanism and ice mass balance, it is required to quantify the concentration of blue-ice. We analyzed spectral reflectance characteristics of blue-ice, snow and cloud by using MODIS images obtained over blue-ice areas in McMurdo Dry Valleys, East Antarctica, from 2007 to 2012. We then developed Normalized Difference Blue-ice Index (NDBI) algorithm which quantifies the concentration of blue-ice. Snow and cloud have a high reflectance in visible and near-infrared (NIR) bands. Reflectance of blue-ice is high in blue band, while that lowers in the NIR band. NDBI is calculated by dividing the difference of reflectance in the blue and NIR bands by the sum of reflectances in the two bands so that NDBI = (Blue-NIR)/(Blue + NIR). NDBI calculated from the MODIS images showed that the blue-ice areas have values ranging from 0.2 to 0.5, depending on the exposure and concentration of blue-ice. It is obviously different from that of snow and cloud that has values less than 0.2 or rocks with negative values. The change of NDBI values in the blue-ice area has higher correlation with snow depth ($R^2=0.699$) than wind speed ($R^2=0.012$) or air temperature ($R^2=0.278$), all measured at a meteorological station installed in McMurdo Dry Valleys. As the snow depth increased, the NDBI value decreased, which suggests that snow depth can be estimated from NDBI values over blue-ice areas. The NDBI algorithm developed in this study will be useful for various polar research fields such as meteorite exploration, analysis of ice mass balance as well as the snow depth estimation.