• Title/Summary/Keyword: Mask Fitting

Search Result 29, Processing Time 0.033 seconds

Half-Mask Interface Prototype Design using Korean Face Anthropometric Data (한국인 안면부 인체 데이터를 이용한 마스크 계면 프로토타입 설계)

  • Song, Young-Woong;Yang, Won-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.87-92
    • /
    • 2010
  • The mask-face interface design should consider the face shape to improve the half mask respirator's fit ratio. This study tried to design the mask-face interface using recent Korean face data. By using the data of 1536 men's 3D face scanning (Size Korea data), head clay mock-up was made and mask-face interface line was extracted from this head mock-up. Using this interface line, the half-mask prototype was made. According to the quantitative fitting test, the proposed mask was found to be well fitted (average fit-ratio > 100). The proposed method had two advantages. 1) The method could use massive head-related anthropometric data like Size Korea data. 2) The qualitative fit test (observation) could be conducted very quickly by fitting the prototype to the head mock-up. However, this method also had several limitations. 1) The head clay mock-up could be different according to the mock-up maker. 2) The average values of the head-related anthropometric data were used to make the head mock-up. Small and large size head mock-ups should be made and tested.

Effects of Fit Factor and Visual Acuity of Eyeglasses Wearers when Wearing Particulate Filtering Facepiece Respirators (안경착용자 방진마스크 착용 시 밀착계수와 착용시력에 미치는 영향)

  • Eoh, Won Souk;Shin, Chang Sup
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.3
    • /
    • pp.105-115
    • /
    • 2020
  • This study compares the difference of fit factors (FF) and visual acuity according to masks and eyeglasses preferences for 54 participants. We the precautions and behaviors of discomfort when wearing masks of eyewear wearers. Contact lens discomfort and priority action of complaints was investigated Glasses fitting factors is Optical Center Height(OH), Vertex Distance(VD) and Pantoscopic Angle(PA). We measured those factors and expressed by the ratio of standard point and change point. Quantitative fit factor was measured by Portacount Pro+ 8038. Also, we selected to 6 exercises among 8 exercises OSHA QNFT (Quantitative Fit testing) protocol to measure the fit factors. The pass/ fail criterion of FF was set at 100. Visual acuity(VA) test chart is developed by Chunsuk Han was used, Descriptive statistics was performed. Descriptive statistics(SAS ver 9.2), it is used geometric means, Wilcoxon analysis(P=0.05) When wearing the mask preferentially, fit factor(FF) was high according to the step of glasses fitting parameter. on the other hand, when the glasses first choice, the visual acuity(VA) was high. there was no significant difference. In the case of fit factor (FF), mask first choice/ glasses first choice is OH (p=0.671/ p=0.332), VD (p=0.602/ p=0.571) and PA (p=0.549/ p=0.607). Visual acuity (VA), mask first choice/ glasses first choice is OH (p=0.753/ p=0.386), VD (p=0.815/ p=0.557) and PA (p=0.856/ p=0.562). The workers of workplace and office chose glasses but occupational health workers and students chose mask. In case of discomforts, it was suggested to remove the mask and tolerate discomforts. The main discomforts and usual action of lens were dryness, hyperemia, foreign body sensation, ophthalmodynia, decreased vision and glasses wearing. Therefore, it is necessary to develop a mask wearing method education program considering glasses fitting and develop a hybrid model that minimizes inconvenience when wearing glasses and a mask at the same time.

Correlation of Fit Factors for Respirators and Anthropometric Dimension (호흡기보호구의 밀착계수와 안면구조의 관계)

  • Han, Don-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.440-448
    • /
    • 1998
  • In many developed countries, for example, USA, respirator fit testing is required before entering specific work environment to ensure that the respirator worn satisfies a minimum of fit and that the user knows when the respirator fits properly. Unfortunately because we have not fit test regulation in Korea, a lot of workers wearing respirators may be potentially exposed to hazards. This study was conducted to evaluate the fitting performance for respirators and correlation fit factors with facial dimensions of wearers. 110 subjects (70 males, 40 females) were fit tested for three quarter masks, i.e., two domestic-made Mask 2, and Y and one foreign-made Mask T using PortaCount 8020. A facial dimension survey of the same subjects was conducted to develop a facial dimension grids fer correlation fit factors with facial dimension parameters. A facial dimension grid was developed on the basis of face length and lip length for quarter masks. The results obtained were as follows : 1 Fit factors of Mask T were much higher than those of Masks Z, and Y. 2. Males were fitted more properly than females. 3. Male in box 'f' of grid would be adequately fitted Mask Y and male in box 'b', 'e', 'f', 'h' of grid would be sufficiently fitted Mask T. Female in box 'h' of grid may have a good fitting performance for both Mask Y, and T. But subjects in all boxes of grid would be inadequately fitted Mask Z.

  • PDF

Automatic Brain Segmentation for 3D Visualization and Analysis of MR Image Sets (MR영상의 3차원 가시화 및 분석을 위한 뇌영역의 자동 분할)

  • Kim, Tae-Woo
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.2
    • /
    • pp.542-551
    • /
    • 2000
  • In this paper, a novel technique is presented for automatic brain region segmentation in single channel MR image data sets for 3D visualization and analysis. The method detects brain contours in 2D and 3D processing of four steps. The first and the second make a head mask and an initial brain mask by automatic thresholding using a curve fitting technique. The stage 3 reconstructs 3D volume of the initial brain mask by cubic interpolation and generates an intermediate brain mask using morphological operation and labeling of connected components. In the final step, the brain mask is refined by automatic thresholding using curve fitting. This algorithm is useful for fully automatic brain region segmentation of T1-weighted, T2-weighted, PD-weighted, SPGR MRI data sets without considering slice direction and covering a whole volume of a brain. In the experiments, the algorithm was applied to 20 sets of MR images and showed over 0.97 in comparison with manual drawing in similarity index.

  • PDF

Vehicle Classification by Road Lane Detection and Model Fitting Using a Surveillance Camera

  • Shin, Wook-Sun;Song, Doo-Heon;Lee, Chang-Hun
    • Journal of Information Processing Systems
    • /
    • v.2 no.1
    • /
    • pp.52-57
    • /
    • 2006
  • One of the important functions of an Intelligent Transportation System (ITS) is to classify vehicle types using a vision system. We propose a method using machine-learning algorithms for this classification problem with 3-D object model fitting. It is also necessary to detect road lanes from a fixed traffic surveillance camera in preparation for model fitting. We apply a background mask and line analysis algorithm based on statistical measures to Hough Transform (HT) in order to remove noise and false positive road lanes. The results show that this method is quite efficient in terms of quality.

A System for Recognizing Sunglasses and a Mask of an ATM User (현금 인출기 사용자의 선글라스 및 마스크 인식 시스템)

  • Lim, Dong-Ak;Ko, Jae-Pil
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.1
    • /
    • pp.34-43
    • /
    • 2008
  • This paper presents a system for recognizing sunglasses and a mask of an ATM (Automatic Teller Machine) user. The proposed system extracts firstly facial contour, then from this extraction results it estimates the regions of eyes and mouth. Finally, it recognizes sunglasses and a mouth using Histogram Indexing based on those regions. We adopt a face shape model to be able to extract facial contour and to estimate the regions of eyes and mouth when those regions are occluded by sunglasses and a mask. To improve the fitting accuracy of the shame model, we adopt 2-step face detection method and conduct fitting several times by varying the initial position of the model instance. To achieve a good performance of the face detection method based on a background model, we enable the system to automatically update the background model. In experiment, we present some experiments on setting parameters of the system with images taken from in our laboratory, and demonstrate the results of recognizing sunglasses and a mask.

  • PDF

Scattering Bar Optical Proximity Correction to Suppress Overlap Error and Side-lobe in Semiconductor Lithography Process (Overlap Margin 확보 및 Side-lobe 억제를 위한 Scattering Bar Optical Proximity Correction)

  • 이흥주
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.1
    • /
    • pp.22-26
    • /
    • 2003
  • Overlap Errors and side-lobes have been simultaneously solved by the rule-based correction using the rules extracted from test patterns. Lithography process parameters affecting attPSM lithography process have been determined by the fitting method to the real process data. The correction using scattering bars has been compared to the Cr shield method. The optimal insertion rule of the scattering bal's has made it possible to suppress the side-lobes and to enhance DOF at the same time. Therefore, in this paper, the solution to both side-lobe and overlap Error has been proposed using rule-based confection. Compared to the existing Cr shield method, the proposed rule-based correction with scattering bars can reduce the process complexity and time for mask production.

  • PDF

Analysis of 3D Facial Shapes of Female Adult to Improve Face Mask Fit

  • Choi, Jin;Do, Wol Hee
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.826-833
    • /
    • 2020
  • When it is necessary to wear masks for long periods, such as during the current COVID-19 pandemic, the essential function of masks to prevent contamination (or transmission to others) as well as comfortableness are important. For this study, we used three-dimensional (3D) facial measurements of adult women to compile basic face shape data for designing comfortable and effective masks. This study analyzed the 3D facial data of 127 subjects in their 20s to 30s of the 6th Size Korea. Factor analysis of the survey data produced seven factors that formed the composition of adult female faces. These factors combined to produce three facial types: square (long face and a large lower middle face), oval (smallest central and lower body in the middle), and triangle (short face with a small central and lower large nose). These types reflect that the facial types of adult women show the differences in the nose angle, nose length, bitragion-subnasal arc, bitragion-menton arc. Therefore, properly fitting masks for fine dust particle filtration require 3D customization of a mask's breathing apparatus to fit differently shaped central and lower face parts that interfere with mask fit.

Designing of standard sizing system for hygienic masks (의약외품 마스크의 표준 치수 규격 개발)

  • Oh, Seol Young;Suh, Dong Ae
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.4
    • /
    • pp.495-512
    • /
    • 2022
  • This study aims to design a new sizing system for hygienic masks to protect against COVID-19-related respiratory disorders. The product sizes were collected from 70 commercially available hygienic masks, and 18 head measurements were obtained from the three-dimensional (3D) scan data of 2,048 men and women aged 20 to 69 years from the 6th Size Korea Survey. The statistical analysis was performed using the IBM Statistical Package for the Social Sciences (SPSS) 28.0 program. The "bitragion-subnasale arc" and "menton-sellion length" were chosen as the key body dimensions for the hygienic mask sizing system. The linear regressions with 18 3D head measurements were analyzed, and it was determined that the key body dimensions were useful for statistically predicting other 3D head measurements related to hygienic masks. A new sizing system was proposed for two types of masks, "masks with a tight fit" and "masks with a loose fit," taking into account the existing Korean Industrial Standards (KS) and the shortcomings of the sizes of hygienic masks on the market. The sizing system for tight-fitting masks consisted of the key body dimensions, with their sizes indicated by a pair of numbers. The sizing system for loose-fitting masks consisted solely of the bitragion-subnasale arc, with their sizes denoted by letters such as S, M, and L (denoting small, medium, and large, respectively). Future studies should consider this mask sizing system for different age groups, such as children and adolescents.

Fit Testing for Domestic N95 Medical Masks (일개 국내산 의료용 N95 마스크의 밀착도 분석)

  • Seo, Hyekyung;Kang, Byoung-kab;Kwon, Young-il
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.124-133
    • /
    • 2020
  • Objectives: Mask fit is a crucial factor in preventing respiratory infections among healthcare workers. The current coronavirus(COVID-19) pandemic calls for the replacement of imported N95 medical masks with domestic N95 versions. In this study, we aimed to determine whether these masks provide proper protection. Methods: Thirty-five participants from three healthcare institutions donned four types of masks and Quantitative Fit Tests(Portacount, USA) were performed. The order of fit test for the four types of masks was randomized, and a three-minute washout period was applied between test times(2 min 29 sec) to reduce potential error stemming from physical exhaustion. Results: There were no significant differences in the Fit Factor for the four types of masks, and there were no gender differences. However, the Fit Factor significantly differed across the three healthcare institutions (p=0.007). With eight of the 35 participants passing, the pass rate with the criteria of 100 or higher was 21%. Conclusions: The mask used in this study was a new domestic N95 medical mask, and the participants were unfamiliar with how to wear it. They reported difficulties with mask fitting. In light of a previous finding that mask fit improved with frequently used masks, wearer preferred masks, or when masks that are regularly worn are used during fit training, the fact that participants were unfamiliar with the mask used in this study is a limitation that should not be overlooked.