• Title/Summary/Keyword: Maritime Channel

Search Result 385, Processing Time 0.022 seconds

The Change in Patterns and Conditions of Algal Blooms Resulting from Construction of Weirs in the Youngsan River: Long-term Data Analysis (보 건설에 따른 영산강의 조류 발생 및 환경 변화: 수질측정망 장기 자료 분석)

  • Shin, Yongsik;Yu, Haengsun;Lee, Hakyoung;Lee, Dahye;Park, Gunwoo
    • Korean Journal of Ecology and Environment
    • /
    • v.48 no.4
    • /
    • pp.238-252
    • /
    • 2015
  • The effect of weir construction (2009~2011) was investigated on algal bloom dynamics and surrounding conditions in the Youngsan River by analyzing the long-term (2001~2014) data provided by the Water Information System, Ministry of Environment. The data include chlorophyll a and water properties such as total suspended solids (TSS), ammonium ($NH_4{^+}$), nitrate ($NO_3{^-}$), orthophosphate ($PO{_4}^{3-}$), total nitrogen (TN), total phosphorus (TP) and DIN/DIP molar ratio collected from 12 stations along the channel of the river. Temporal variations were examined using data collected monthly from 2001~2014 and Box-Whisker plot was used to examine the difference in algal bloom dynamics between before (2006~2008) and after (2012~2014) the weir construction. Pearson's correlation analysis was also used to analyze the correlation of parameters. The results showed that TSS affecting water turbidity increased during the construction but decreased especially at the stations located in the upper and middle regions of the river after the construction. Ammonium concentrations increased whereas the concentrations of other nutrients decreased after the construction inducing an increase in N:P molar ratio. Chlorophyll a decreased suddenly during the construction but increased clearly after the construction at the stations where TSS decreased. This indicates that algal blooms can develop in the Youngsan River due to a decrease in turbidity that increases light penetration in water column although the concentrations of nutrients such as orthophosphate were reduced after the weir construction.

Development of a 4S Multiple Media Switching Server and an Information Exchange System (4S 다중매체 스위칭 서버와 육해상 정보교환 시스템 개발)

  • Mun, Seong-Mi;Jang, Won-Seok;Son, Joo Yong;Yang, Gyu-Sik
    • Journal of Navigation and Port Research
    • /
    • v.37 no.3
    • /
    • pp.275-281
    • /
    • 2013
  • Ship Standard Network was submitted as a common subject of e-navigation by 81th IMO MSC 2005. This agenda was given an official status with strategy planning of e-navigation for Ship Standard Network after approval of WG program of 81th MSC 2006. Nowadays approximately 400 heterogeneous navigation and communication equipments are working on ships at sea. Standardization of ship network is to support exchanging various data efficiently. Among them, 4S network is defined as a wireless communication network between ship to ship and ship to shore which provides unceasing communication channel ship to shore. It has been expected to trigger various services and applications based on 4S network. However, no technologies and products has been appeared at fields yet. but now there's not specific technologies and developing products. In this paper, We developed a 4S multiple media switching server and a ship-land information exchange system to overcome the heterogeneity and provide efficient communication environments.. The performance of the implemented system was verified by TTA(Telecommunications Technology Association) V&V(Verification and Validation).

Implementation of pressure monitoring system(PMS) for ship's engine performance analysis(SEPA) based on the web (웹기반 선박엔진 성능분석용 압력모니터링 시스템 구현)

  • Yang, Hyun-Suk;Kwon, Hyuk-Joo;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.929-935
    • /
    • 2014
  • This paper is study on the pressure monitoring system(PMS) for ship's engine performance analysis( SEPA) based on web, with high speed and accuracy. This system is composed of pressure sensor, monitoring module with multi channel A/D converter, TCP/IP and satellite internet communication system. Existing domestic products measure cylinder pressure when piston of first explosive cylinder reached TDC(the top dead center) point and then measure next cylinder pressure manually each angle divided by a constant rotating interval. But presented system monitors in the local and web computer, using pressure information transmitted from pressure sensor installed on each engine. In this system, it is possible to increase the accuracy of the engine performance analysis because not only each TDC points but cylinder pressures synchronized with the TDC points could be measured in real time, accurately. And therefore, it may be used in a various diagnosis of main engines, such as deviations of each cylinder maximum pressures(Pmax) and the TDC firing positions and combustion conditions.

Analysis of PRC regeneration algorithm performance in dynamic environment by using Multi-DGPS Signal (다중 DGPS 신호를 이용한 동적 환경에서의 PRC 재생성 알고리즘 성능분석)

  • Song Bok-Sub;Oh Kyung-Ryoon;Kim Jeong-Ho
    • The KIPS Transactions:PartA
    • /
    • v.13A no.4 s.101
    • /
    • pp.335-342
    • /
    • 2006
  • As PRC linear interpolation algorithm is applied after analysed and verified in this paper, the unknown location of a user can be identified by using PRC information of multi-DGPS reference station. The PRC information of each GPS satellite is not varying rapidly, which makes it possible to assume that PRC information of each GPS satellite varies linearly. So, the PRC regeneration algorithm with linear interpolation can be applied to improve the accuracy of finding a user's location by using the various PRC information obtained from multi-DGPS reference station. The desirable PRC is made by the linear combination with the known position of multi-DGPS reference station and PRC values of a satellite using signals from multi-DGPS reference station. The RTK-GPS result was used as the reference. To test the performance of the linearly interpolated PRC regeneration algorithm, multi-channel DGPS beacon receiver was built to get a user's position more exactly by using PRC data of maritime DGPS reference station in RTCM format. At the end of this paper, the result of the quantitative analysis of the developed navigation algorithm performance is presented.

Effect on the Wake Flow according to Various length of Rectangular Cylinder in a Parallel Arrangement (병렬구조를 가진 장방형 실린더의 길이가 후류 유동에 미치는 영향)

  • Choe, Sang-Bom;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.760-767
    • /
    • 2014
  • An experimental study is carried out to investigate the effect of jet stream in the gab of rectangular cylinders with different length in a parallel arrangement by using PIV method in a circulating water channel. The height(h) of the rectangular cylinder and the gap between the cylinder is 10mm, and the width(B) which is 300mm. The length of the model for flow direction was applied to 30mm, 60mm, 90mm & 120mm, The aspect ratio of a model on the basis of height(H=30mm) is 1, 2, 3 and 4. Reynolds number $Re=1.4{\times}10^4$, $Re=2.0{\times}10^4$, $Re=2.9{\times}10^4$ based on the height(H) of model for the distance of tidal distributions as of water depth have been applied during the whole experiments. The measurement area was set to 5H rear of the cylinder. As a result, Vortex size in the wake area were increased as velocity increased. and high aspect ratio increased through-flow velocity component in the near wake. Velocity deficit increased highly after near-wake area and low aspect ratio.

Design of Performance Monitoring System for eLoran Time Synchronization Service (eLoran 시각동기 성능 모니터링 시스템 설계)

  • Seo, Kiyeol;Son, Pyo-Woong;Han, Younghoon;Park, Sang-Hyun;Lee, Jong-Cheol
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.815-821
    • /
    • 2021
  • This study addresses on the design of performance monitoring system for the time synchronization service of the enhanced long-range navigation (eLoran) system, which has a representative ground-wave radio broadcast system capable of providing positioning, navigation, timing and data (PNT&D) services. The limitations of time-synchronized systems due to the signal vulnerabilities of the global navigation satellite system (GNSS) are explained, and the performance monitoring system for the eLoran timing service as a backup to the GNSS is proposed. The time synchronization service using eLoran system as well as system configurations and the user requirements in the differential Loran (dLoran) system are described to monitor the time synchronization performance. The results of the designed system are presented for long-term operation in the eLoran testbed environment. As the results of time performance monitoring, we were able to verify the time synchronization precision within 43.71 ns without corrections, 22.52 ns with corrections. Based on these results, the eLoran system can be utilized as a precise time synchronization source for GPS timing backup.

A Study on the Optimal Span Width in the Bridge Main Span of Incheon 2nd Bridge (1) Evaluation on the Optimal Main Span Width according to Traffic Volume and Ship Maneuverability (인천항 제2연륙교 주경간의 적정 교각폭 결정에 관한 연구 (1) 교통량 측면과 선박 조종성 측면에서의 소요 교각폭 산정)

  • Koo Ja-Yun;Kim Seok-Jae;Jang Eun-Kyu;Kim Se-Won
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.175-181
    • /
    • 2004
  • A construction project of Incheon 2nd bridge, which is connected between the Incheon Song-Do New Town and the Incheon International Airport in Young-Jong-Do, have been proposed by the private capital in 1999. But the optimal span width in the bridge main span have not been decided in spite of the three investigations into the feasibility of ship's safe transit in this planned bridge. In this paper, we study the optimal main span width according to the traffic volume in the future traffic and the ship maneuverability of maximum size aspect. The result cf this study, Incheon 2nd bridge main span design is required to design two-way traffic scheme and 1,000m span width, which will satisfy the safe transit from the viewpoint of the traffic volume in the future traffic and the ship maneuverability maximum size.

  • PDF

The Effect of Fluid Flow on Power Density in a Horizontal-flow Microbial Fuel Cell (수평 흐름형 미생물 연료전지에서 유체의 흐름 형태에 따른 전력수율 평가)

  • Lee, Chae-Young;Park, Su-Hee;Song, Young-Chae;Yoo, Kyu-Seon;Chung, Jae-Woo;Han, Sun-Kee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.21 no.1
    • /
    • pp.39-44
    • /
    • 2013
  • This study evaluated the effect of fluid flow on the power density in a horizontal-flow microbial fuel cell (MFC). The maximum power densities in four types of flow induced by different channel types in the anode chamber were investigated. The fluid flow at each channel was analyzed using tracer tests. Results of polarization curves showed that the maximum power densities of case 1, 2, 3 and 4 were 95.7, 129.1, 190.9 and 114.2 mW/m2, respectively. Case 3 with a set of guide walls where flow had an S type-like shape showed the highest power density. Based on the Morrill Dispersion Index (MDI) value of case 4, microbial activity would be enhanced since the reactor allows even distribution of substrate but the overflow occurrence would not guarantee stable performance. Therefore, case 3 could be an effective reactor type for MFC because of high electricity generation and stable performance.

A Congestion Control Scheme for transmittiing Connectionless Data Traffic in ATM Network (ATM망에서 비연결형 데이터 트래픽 전달을 위한 폭주 제어 방안)

  • Park, Chun-Kwan;Jeon, Byung-Chun;Kim, Young-Sun
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.42-51
    • /
    • 1998
  • This paper suggests a congestion control scheme for CL (ConnectionLess) overlay network using the feedback loops between CL user and CL server, between CL servers, and between end-to-end CL users, and the header translation table of CL server. The CL overlay network for CBDS(Connectionless Broadhand Data Service) defined by ITU-T((International Telecommunication Union-Telecommunication) consists of CL servers which route frames and links which connect between CL user and CL server or between CL servers. In the CL overlay network, two kinds of congestion, CL link congestion and CL server congestion, may occur. We considered the schemes to solve the congestion. link-by-link method[18] has used the ABR feedback loops of ATM layer between CL user and CL server or between CL servers, and the congestion table using header translation table of CL server. As in congestion of output virtual channel this method has an effect on all the traffic transmitting through the link, then it has an effect on the traffic that has not caused the congestion. As a result, the link utilization of output virtual channel that does not bring the congestion and outputs the traffic is decreased. To overcome this drawback of link-by-link, we proposed the hybrid method that are using the ABR feedback loops of link-by-link method, the feedback loop between CL users in end-to-end, the congestion table using and the header translation table. This scheme deals with teh congestion immediately by link-by-link loops and the header translation table, and then regulates the sending rate of CL user that causes the congestion by end-to-end loop.

  • PDF

Channel characteristics of multi-path power line using a contactless inductive coupling unit (비접촉식 유도성 결합기를 이용한 다중경로 전력선 채널 특성)

  • Kim, Hyun-Sik;Sohn, Kyung-Rak
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.799-804
    • /
    • 2016
  • Broadband powerline communication (BPLC) uses distribution lines as a medium for achieving effective bidirectional data communication along with electric current flow. As the material characteristics of power lines are not good at the communication channel, the development of power line communication (PLC) systems for internet, voice, and data services requires measurement-based models of the transfer characteristics of the network suitable for performance analysis by simulation. In this paper, an analytic model describing a complex transfer function is presented to obtain the attenuation and path parameters for a multipath power line model. The calculated results demonstrated frequency-selective fading in multipath channels and signal attenuation with frequency, and were in good agreement with the experimental results. Inductive coupling units are used as couplers for coupling the signal to the power line to avoid physical connections to the distribution line. The inductance of the ferrite core, which depends on the frequency, determines the cut-off frequency of the inductive coupler. Coupling loss can be minimized by increasing the number of windings around the coupler. Coupling efficiency was improved by more than 6 dB with three windings compared to the results obtained with one winding.